← Product Code [FPA](/productcode/FPA) · K961928

# BIOMEDIX I.V. EXTENSION LINE W/ STOPCOCK MODEL B50-102/B51-102 (K961928)

_Biomedix, Inc. · FPA · Sep 16, 1996 · General Hospital · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K961928

## Device Facts

- **Applicant:** Biomedix, Inc.
- **Product Code:** [FPA](/productcode/FPA.md)
- **Decision Date:** Sep 16, 1996
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 880.5440
- **Device Class:** Class 2
- **Review Panel:** General Hospital
- **Attributes:** Therapeutic

## Indications for Use

This product would be used by Nurses and Paramedics in prehospital, emergency room and field situations.

## Device Story

I.V. Extension with Stopcock facilitates intravenous fluid/drug administration; provides extra length between I.V. supply and patient; includes four-way stopcock for fluid source selection; features slip-type clamp to prevent backflow/dilution. Used by nurses and paramedics in prehospital, emergency room, and field settings. Available in two models: standard needle-type injection site or blunt cannula (needleless) injection site. Device connects to primary I.V. set to allow direct injection at patient catheter site.

## Clinical Evidence

No clinical data. Bench testing only.

## Technological Characteristics

I.V. extension line assembly with four-way stopcock. Features include threaded and/or slip luer connections, 3.75 mL capacity, and 0.114" I.D. tubing. Available with needle-type or blunt cannula (needleless) injection sites. Includes slip-type tubing clamp. Construction utilizes commercially available components similar to existing I.V. sets.

## Regulatory Identification

An intravascular administration set is a device used to administer fluids from a container to a patient's vascular system through a needle or catheter inserted into a vein. The device may include the needle or catheter, tubing, a flow regulator, a drip chamber, an infusion line filter, an I.V. set stopcock, fluid delivery tubing, connectors between parts of the set, a side tube with a cap to serve as an injection site, and a hollow spike to penetrate and connect the tubing to an I.V. bag or other infusion fluid container.

## Special Controls

*Classification.* Class II (special controls). The special control for pharmacy compounding systems within this classification is the FDA guidance document entitled “Class II Special Controls Guidance Document: Pharmacy Compounding Systems; Final Guidance for Industry and FDA Reviewers.” Pharmacy compounding systems classified within the intravascular administration set are exempt from the premarket notification procedures in subpart E of this part and subject to the limitations in § 880.9.

## Predicate Devices

- Baxter PHARMASEAL K52 NOVEX Three-Way Stopcock with Extension Tube (K52)
- Medex Extension Set
- McGaw G0719 I.V. Extension Set
- McGaw G0726 I.V. Extension Set
- McGaw G0716 I.V. Extension Set

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}

BIOMEDIX
quality medical products
K961928
SEP 16 1996

TO: Food and Drug Administration
Center for Devices and Radiological Health (HFZ-401)
9200 Corporate Blvd.
Rockville, MD 20850

FROM: Daniel J. Dyar, President

DATE: May 17, 1996 (Revised June 11, 1996)

SUBJECT: 510 K Summary

TRADE NAME: I.V. Extension with Stopcock.

COMMON NAME: I.V. Extension

CLASSIFICATION NAME: [ 880.5440 ] Intravascular Administration Set

SUBSTANTIALLY
EQUIVALENT TO:

Biomedix, Inc. claims substantial equivalence regarding this design of the I.V. Extension Line Assembly with Stopcock as follows:

Products currently on the market include:

Baxter PHARMASEAL K52 NOVEX Three-Way Stopcock with Extension Tube.
( Sterile, For Single Use Only, Capacity 2.3 mL, Length 50.8 cm. Blue Protector covers Male Adapter. )

Medex Extension Set - 12" Extension with "Y" Injection Site.

McGaw - G0719 I.V. Extension Set, Female and Needle Adapter, Vol. 3 mL., Length 21"
G0726 I.V. Extension Set with (2) Injection Sites, Vol. 6 mL., Length 33"
G0716 I.V. Extension Set with (2) Injection Sites with check valve and
flashtube., Vol. 6 mL., Length 34"
PAGE 15

45 South Main Street P.O. Box 231 Spencer, Indiana 47460 800-627-2765 812-829-9667 FAX: 812-829-9650

{1}

510 K SUMMARY ( CONTINUED )

DESIGN COMPARISONS:

|  COMPONENT | BIOMEDIX | BAXTER K52 | MEDEX EXTENSION SET  |
| --- | --- | --- | --- |
|  Stopcock | All 3 ports include both threaded and / or slip luer connections. | ( 1 ) Port has removeable needle injection site. ( 2 ) remaining ports have slip luer conn. only. | ( 1 ) Y - Port for Sharps Devices.  |
|  Capacity | 3.75 ml. | 2.3 ml. | N/A  |
|  Tubing | .114 +/- .002" I.D. | .088-.090" I.D. | N/A  |
|  Connections | Choice of Needle or Blunt Cannula Y-Site with Male Slip Luer Connector. | Male Slip Luer Connector Only. | Male Slip Luer Connector Only.  |

The Biomedix design allows injection of solutions directly at the Patient I.V. Catheter. A slip-type clamp on the tubing portion of the I.V. Extension Line allows the line to be shut-off preventing backflow and/or dilution of administered fluids away from the patient.

DESCRIPTION:

The I.V. Extension Line Assembly with Stopcock is attached to the Primary I.V. to facilitate two advantages. One, is to add extra length between the I.V. Supply and the Patient. A second, is to provide additional supply ports for the administration of alternate solutions and special drugs that are administered intravenously. A four-way stopcock offers selection of the fluid types and sources. Biomedix is offering two models, one with a standard Needle-Type Injection Site at the Outlet and a second with a Blunt Cannula (Needleless) Type Injection Site at the outlet.

INTENDED USE:

This product would be used by Nurses and Paramedics in prehospital, emergency room and field situations.

PAGE 16

{2}

510 K SUMMARY ( CONTINUED )

## SUMMARY OF DEVICE COMPARISONS:

Basic construction of both Biomedix and Competitive Products of this type are of commercially available components. Biomedix already employs a process and construction similar to this in their existing Selec-3 Primary I.V. Set.

Sincerely,

![img-0.jpeg](img-0.jpeg)

Daniel J. Dyar
President Biomedix, Inc.

PAGE 16a

---

**Source:** [https://fda-staging.innolitics.com/device/K961928](https://fda-staging.innolitics.com/device/K961928)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).