VASO-SAFE ARTERIAL EMBOLECTOMY CATHETE

K961716 · Ideas For Medicine, Inc. · DXE · Sep 19, 1996 · Cardiovascular

Device Facts

Record IDK961716
Device NameVASO-SAFE ARTERIAL EMBOLECTOMY CATHETE
ApplicantIdeas For Medicine, Inc.
Product CodeDXE · Cardiovascular
Decision DateSep 19, 1996
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 870.5150
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The catheters are intended for use in the removal of arterial emboli and thrombi during embolectomy and thrombectomy.

Device Story

Single lumen nylon tube with distal natural latex balloon and proximal stopcock; packaged with syringe. Available in 5 French sizes and 3 lengths. Operated by physicians in clinical settings. Procedure: catheter advanced beyond clot with balloon deflated; balloon inflated with sterile solution; catheter withdrawn to extract embolism. Benefits: mechanical removal of arterial obstructions.

Clinical Evidence

Bench testing only; materials certified to USP Class VI requirements.

Technological Characteristics

Single lumen nylon tube; natural latex balloon; proximal stopcock. Materials meet USP Class VI standards; suture meets USP grade. Sterile and non-pyrogenic. Mechanical operation via manual inflation/withdrawal.

Indications for Use

Indicated for patients requiring removal of arterial emboli and thrombi during embolectomy and thrombectomy procedures.

Regulatory Classification

Identification

An embolectomy catheter is a balloon-tipped catheter that is used to remove thromboemboli, i.e., blood clots which have migrated in blood vessels from one site in the vascular tree to another.

Predicate Devices

Submission Summary (Full Text)

{0} K961716 Ideas for Medicine, Inc. Vaso-Safe Arterial Embolectomy Catheter 510(k) Notification # SAFETY and EFFECTIVENESS SUMMARY **PROPRIETARY NAME:** SEP 19 1996 Vaso-Safe Arterial Embolectomy Catheter **COMMON USUAL NAME:** Embolectomy Catheter **CLASSIFICATION:** Class II **CLASSIFICATION NUMBER:** 74 DXE **DEVICE DESCRIPTION:** The Vaso-Safe Arterial Embolectomy Catheter is a single lumen nylon tube with a natural latex balloon attached to a distal end and a stopcock affixed to the proximal end. It will be packaged with a syringe. The catheter will be available in 5 french sizes and 3 lengths. The catheters are intended for use in the removal of arterial emboli and thrombi during embolectomy and thrombectomy. The catheter, with the balloon deflated, is advanced into the vessel beyond the clot. The balloon is inflated with sterile solution. The catheter is withdrawn pulling the embolism with it, thus removing it from the artery. The materials used on the Vaso-Safe Arterial Embolectomy Catheters have been used for years on other models of Ideas for Medicine, Inc. catheters except the suture, which has been certified to USP grade. Other catheter materials have been certified to meet the requirements of USP Class VI tests. Every lot is supplied sterile and non-pyrogenic. **SUBSTANTIAL EQUIVALENCE:** The intended use of these devices is to remove arterial emboli and thrombi. This use is identical to the Fogarty Embolectomy Catheter. The Robicsek Angiography Embolectomy Catheters are for arterial emboli and thrombi removal but provide the ability to irrigate concurrent with removal. 6
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...