← Product Code [KMF](/productcode/KMF) · K961452

# LYOFOAM EXTRA 'A' STERILE ADHESIVE WOUND DRESSING (K961452)

_Acme United Corp. · KMF · May 31, 1996 · General Hospital · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K961452

## Device Facts

- **Applicant:** Acme United Corp.
- **Product Code:** [KMF](/productcode/KMF.md)
- **Decision Date:** May 31, 1996
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 880.5090
- **Device Class:** Class 1
- **Review Panel:** General Hospital
- **Attributes:** Therapeutic

## Indications for Use

The Lyofoam® Extra "A" Sterile Adhesive Wound Dressing is intended for the treatment of moderately to heavily exuding wounds while the Modified Lyofoam® Wound Dressing would be used to treat lightly to moderately exuding, wounds. Lyofoam® Extra "A" provides a waterproof barrier for the wound which is moisture vapor permeable and helps to prevent bacterial contamination of the wound.

## Device Story

Lyofoam® Extra "A" is a sterile, adhesive, polyurethane foam island dressing; combines extra-absorbent foam pad with adhesive border. Device functions as a waterproof, moisture vapor permeable barrier to prevent bacterial contamination; absorbs excess wound fluid. Used in clinical or home settings for wound management. Healthcare providers apply dressing over wound; adhesive border secures device in place. Benefits include enhanced fluid management for heavily exuding wounds and protection against external contaminants.

## Clinical Evidence

No clinical data. Performance and safety data rely on previously submitted files K952565 and K895764.

## Technological Characteristics

Polyurethane foam island dressing; adhesive border; waterproof and moisture vapor permeable; sterilized via gamma radiation (SAL 10⁻⁶); packaged in paper/foil peel pouch.

## Regulatory Identification

A liquid bandage is a sterile device that is a liquid, semiliquid, or powder and liquid combination used to cover an opening in the skin or as a dressing for burns. The device is also used as a topical skin protectant.

## Predicate Devices

- Modified Lyofoam® Wound Dressing ([K895764](/device/K895764.md))
- Lyofoam® Extra Absorbent Wound Dressing ([K952565](/device/K952565.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}

Page 12
K961452
Page 1 of 3

Acme United Corporation

MAY 31 1996

510(K) SUMMARY

Submitter's Name: Acme United Corporation
75 Kings Highway Cutoff
Fairfield, CT 06430

Contact Person: Thomas E. Flynn, Director of Regulatory
Affairs and Quality Assurance

Telephone Number: 203-332-7330
Fax Number: 203-576-0007
Date of Submission:

"This summary of 510(K) safety and effectiveness information
is being submitted in accordance with the requirements of SMDA
1990 and 21 CFR 807.92."

The assigned 510(K) number is:

Proprietary Name of Device: Lyofoam® Extra "A" Sterile Adhesive
Wound Dressing
Common/Usual Name: Extra absorbent, polyurethane foam
island dressing.
Classification Name: Dressing, Class I
Product Claiming
Equivalence To: Modified Lyofoam® Wound Dressing and
Lyofoam® Extra Absorbent Wound
Dressing
Description of Device: Lyofoam® Extra "A", Extra Absorbent,
Non-Adherent Polyurethane Foam
Dressing with adhesive boarder.

)

Medical Products Division • 75 Kings Highway Cutoff, Fairfield, Connecticut 06430 • Phone (203) 332-7330

{1}

Page 13
K961452
Page 2 of 3

# Acme United Corporation

Intended Use, Comparison To Predicate Device:

The Lyofoam® Extra "A" Sterile Adhesive Wound Dressing is a combination of the Lyofoam® Extra product and the Modified Lyofoam® Dressing Product (Lyofoam® "A"). The main difference between them is that Lyofoam® Extra Foam Dressing is used in place of the regular Lyofoam® for the wound dressing pad segment of this product. The third layer of thin foam is extended beyond the wound pad and has a adhesive coating which is used to hold the product in place over the wound.

The inner absorbent layer of Lyofoam® Extra Wound Dressing Pad holds more excess wound fluid than the Modified Lyofoam® Wound Dressing Pad which is made from regular Lyofoam®. The Lyofoam® Extra "A" Sterile Adhesive Wound Dressing is intended for the treatment of moderately to heavily exuding wounds while the Modified Lyofoam® Wound Dressing would be used to treat lightly to moderately exuding, wounds. Lyofoam® Extra "A" provides a waterproof barrier for the wound which is moisture vapor permeable and helps to prevent bacterial contamination of the wound.

Medical Products Division • 75 Kings Highway Cutoff, Fairfield, Connecticut 06430 • Phone (203) 332-7330

{2}

Page 14
K961452
Page 3 of 3

Acme United Corporation

Performance data for this product can be found in the Lyofoam® Extra 510(K) File K952565.

Safety:
Safety test data can be found in both the Lyofoam® Extra 510(K) file K952565 and Modified Lyofoam® Dressing file; K895764. All safety data is summarized in those files and indicates product is safe for use.

Sterility and Packaging:
Lyofoam® Extra "A" Sterile Adhesive Wound Dressing is packaged in a paper/foil peel pouch and is sterilized using gamma radiation and has a SAL 10⁻⁶.

Medical Products Division • 75 Kings Highway Cutoff, Fairfield, Connecticut 06430 • Phone (203) 332-7330

---

**Source:** [https://fda-staging.innolitics.com/device/K961452](https://fda-staging.innolitics.com/device/K961452)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
