FINESSE LOW-FUSING PORCELAIN SYSTEM AUXILIARY PRODUCTS

K961291 · Dentsply Intl. · EIH · May 28, 1996 · Dental

Device Facts

Record IDK961291
Device NameFINESSE LOW-FUSING PORCELAIN SYSTEM AUXILIARY PRODUCTS
ApplicantDentsply Intl.
Product CodeEIH · Dental
Decision DateMay 28, 1996
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 872.6660
Device ClassClass 2

Indications for Use

The FINESSE™ LOW-FUSING PORCELAIN SYSTEM AUXILIARY PRODUCTS are for use with the Finesse™ Low-Fusing Porcelain System in conjunction with non-precious or noble or high noble alloys when used for conventional porcelain-fused-to-metal crowns, bridges or dental prostheses.

Device Story

Auxiliary dental porcelain products; mixtures of frits, opacifiers, and pigments; used with Finesse Low-Fusing Porcelain System. Components include opaque modifiers, opaque correction, dentin correction, stains, and glaze porcelains. Applied by dental technicians in laboratory settings to create varied fusion temperatures, translucencies, and colors for dental prostheses. Enhances aesthetic and functional properties of porcelain-fused-to-metal restorations.

Clinical Evidence

Bench testing only; physical properties meet ISO standards; toxicity testing based on predicate device data.

Technological Characteristics

Mixtures of silicate frits, opacifiers, and pigments. Includes opaque modifiers, opaque correction, dentin correction, stains, and glaze porcelains. Physical properties conform to ISO standards.

Indications for Use

Indicated for use in dental laboratories for the fabrication of porcelain-fused-to-metal crowns, bridges, and dental prostheses using non-precious, noble, or high noble alloys.

Regulatory Classification

Identification

Porcelain powder for clinical use is a device consisting of a mixture of kaolin, felspar, quartz, or other substances intended for use in the production of artificial teeth in fixed or removable dentures, of jacket crowns, facings, and veneers. The device is used in prosthetic dentistry by heating the powder mixture to a high temperature in an oven to produce a hard prosthesis with a glass-like finish.

Predicate Devices

Submission Summary (Full Text)

{0} 510(k) SUMMARY K961291 DENTSPLY MAY 28 1996 NAME & ADDRESS: DENTSPLY International 570 West College Avenue P.O. Box 872 York, PA 17405-0872 (717) 845-7511 Fax (717) 854-2343 P. J. Lehn Telefax (717) 849-4343 CONTACT: P. Jeffery Lehn DATE PREPARED: April 2, 1996 TRADE OR PROPRIETARY NAME: FINESSE™ LOW-FUSING PORCELAIN SYSTEM AUXILIARY PRODUCTS CLASSIFICATION NAME: Porcelain Powder for Clinical Use 872.6660 PREDICATE DEVICE: Finesse™ Low-Fusing Porcelain System K954761 DEVICE DESCRIPTION: The FINESSE™ LOW-FUSING PORCELAIN SYSTEM AUXILIARY PRODUCTS contain mixtures of frits, opacifiers and pigments in varied quantities to create an assortment of materials with a variety of fusion temperatures, translucencies and colors. They contain the same silicate frits and opacifiers, and some of the same pigments used in K954761. Additional pigments used are also used in predicate medical devices. The physical properties for FINESSE™ LOW-FUSING PORCELAIN SYSTEM AUXILIARY PRODUCTS meet the appropriate ISO Standards. INTENDED USE: The FINESSE™ LOW-FUSING PORCELAIN SYSTEM AUXILIARY PRODUCTS are for use with the Finesse™ Low-Fusing Porcelain System in conjunction with non-precious or noble or high noble alloys when used for conventional porcelain-fused-to-metal crowns, bridges or dental prostheses. TECHNOLOGICAL CHARACTERISTICS: The FINESSE™ LOW-FUSING PORCELAIN SYSTEM AUXILIARY PRODUCTS consist of opaque modifiers, opaque correction, dentin correction and stains, and glaze porcelains. These porcelains are substantially equivalent to Finesse Low-Fusing Porcelains (K954761). All of the components in the FINESSE™ LOW-FUSING PORCELAIN SYSTEM AUXILIARY PRODUCTS have been used in predicate medical devices. We believe that the prior use of the FINESSE LOW-FUSING PORCELAIN SYSTEM AUXILIARY PRODUCTS components in predicate devices, the performance data, and the results of toxicity testing on the predicate device, support the safety and effectiveness of FINESSE LOW-FUSING PORCELAIN SYSTEM AUXILIARY PRODUCTS for the intended uses. 000037
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...