KODAK DIGITAL SCIENCE(KDS) MEDICAL IMAGE AND INFORMATION LIBRARY

K960981 · Kodak Health Imaging Systems, Inc. · LMB · Jun 7, 1996 · Radiology

Device Facts

Record IDK960981
Device NameKODAK DIGITAL SCIENCE(KDS) MEDICAL IMAGE AND INFORMATION LIBRARY
ApplicantKodak Health Imaging Systems, Inc.
Product CodeLMB · Radiology
Decision DateJun 7, 1996
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 892.2010
Device ClassClass 1

Indications for Use

The KODAK DIGITAL SCIENCE (KDS) Medical Image and Information Library is a DICOM conformant archival product designed for use within a Picture Archiving and Communication System (PACS). The system utilizes a prefetching algorithm to facilitate fast access to previous imagery.

Device Story

KDS Medical Image and Information Library (MIIL) functions as a DICOM-conformant image storage, distribution, and library system within a PACS environment. System components include a Sun SPARC host CPU, magnetic RAID cache, and KODAK DIGITAL SCIENCE ADL 150 writeable CD jukebox. Hierarchical storage library software manages RAID and CD subsystems as a single filesystem. Device inputs include medical images via DICOM; system uses prefetching algorithm to optimize retrieval speed for previous imagery. Output consists of stored/retrieved medical images for clinical review. Operated by radiology staff/technicians in clinical settings. Facilitates efficient image management and access to historical patient data to support clinical decision-making.

Clinical Evidence

No clinical data provided; bench testing only.

Technological Characteristics

System architecture: Sun SPARC station 5 or 20 host CPU, Sun SPARC storage Array RAID subsystem, KODAK DIGITAL SCIENCE ADL 150 writeable CD jukebox. Interface: SCSI. Media: 5.25" CD-Recordable. Power: 100-240 VAC, 50/60 Hz. Connectivity: DICOM conformant, HIS/RIS interface. Software: Proprietary hierarchical storage library management.

Indications for Use

Indicated for use within a Picture Archiving and Communication System (PACS) for the archival, storage, and retrieval of medical images.

Regulatory Classification

Identification

A medical image storage device is a hardware device that provides electronic storage and retrieval functions for medical images. Examples include electronic hardware devices employing magnetic and optical discs, magnetic tapes, and digital memory.

Predicate Devices

Submission Summary (Full Text)

{0} KODAK DIGITAL SCIENCE Premarket Notification K960981 510(k) SUMMARY OF SAFETY AND EFFECTIVENESS JUN - 7 1996 I. DATE PREPARED: March 4, 1996 II. SUBMITTER: Eastman Kodak Company Health Imaging Division Medical Imaging Systems 18325 Waterview Parkway Dallas, Texas 75252-8026 III. CONTACT PERSON: Stan E. Tillman Director, Regulatory Affairs (214) 454-1642 IV. DEVICE NAME: Trade Name - KODAK DIGITAL SCIENCE (KDS) Medical Image and Information Library (MIIL) Common Name - Image Storage, Distribution, and Library V. DEVICE CLASSIFICATION FDA has classified the predicate device as Regulatory Class II under 21 CFR 892.1750. VI. PREDICATE DEVICE Vortech (Kodak) Image Archive and Retrieval System--K915094 {1} KODAK DIGITAL SCIENCE Premarket Notification # VII. DESCRIPTION OF DEVICE The system consists of three main components: 1) the host CPU (a Sun SPARC station 5 or 20) with pre-installed proprietary software, 2) the magnetic cache (a Sun SPARC storage Array RAID subsystem), and 3) a KODAK DIGITAL SCIENCE ADL 150 writeable CD jukebox. The RAID subsystem and the CD jukebox are managed by a hierarchical storage library that presents these two subsystems to the system software running on the host CPU as a single, very large filesystem. The power supply Provides power to operate the unit from a line voltage for 100, 120, 220, or 240 VAC, 50/60 Hz. # VIII. INDICATIONS FOR USE The KODAK DIGITAL SCIENCE (KDS) Medical Image and Information Library is a DICOM conformant archival product designed for use within a Picture Archiving and Communication System (PACS). The system utilizes a prefetching algorithm to facilitate fast access to previous imagery. # V. COMPARISON OF FEATURES SIDE-BY-SIDE COMPARISON TABLE | Item | Description | Price | | --- | --- | --- | | K-number | This 510(k) | K915094 | | Range of Storage | 8GB to 216GB | 37GB to 1.4TB | | Type of Interface | SCSI | SCSI | | Type of Media | 5.25" CD-Recordable | 12" WORM Platters | | DICOM Conformant | Yes, Native | No | | HIS/RIS Interface | Yes | No | | Host Platform | Sun | Sun | | Jukebox, Maximum | Yes, 150-CD | Yes, 140-Platters | | Compression | Yes, lossless 2:1 | Yes, lossless 2:1 | | Database Structure | Distributed | Distributed | 3/96
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...