K954848 · Meadox Medicals, Div. Boston Scientific Corp. · MAL · Feb 1, 1996 · Cardiovascular
Device Facts
Record ID
K954848
Device Name
HEMASHIELD MICROVEL VELOUR KNITTED VASCULAR GRAFT
Applicant
Meadox Medicals, Div. Boston Scientific Corp.
Product Code
MAL · Cardiovascular
Decision Date
Feb 1, 1996
Decision
ST
Submission Type
Traditional
Regulation
21 CFR 870.3450
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
For use in the replacement or repair of arteries affected with aneurysmal or occlusive disease, which is substantially equivalent to the currently marketed devices.
Device Story
HEMASHIELD® cardiovascular grafts consist of knitted or woven polyester fabric impregnated with bovine collagen. These grafts are surgically implanted by vascular surgeons to replace or repair diseased arteries (aneurysmal or occlusive). The collagen impregnation serves to reduce porosity and improve handling characteristics. The device functions as a permanent prosthetic conduit for blood flow. The current submission addresses modifications to the manufacturing process of the collagen component. The device is used in clinical settings (OR) by surgeons; it provides a structural replacement for damaged arterial segments, restoring blood flow and potentially preventing rupture or ischemia.
Clinical Evidence
Bench testing only. No clinical data provided. Testing included burst strength, tensile strength, suture pull-out, wall thickness, longitudinal stretch, needle penetration, crush resistance, flexural rigidity, water permeability, collagen bonding strength, shrinkage temperature, glycerol content, collagen content, and scanning electron microscopy. All results were equivalent to the predicate devices.
Technological Characteristics
Materials: Polyester fabric impregnated with bovine collagen. Form factor: Knitted or woven vascular grafts. Biocompatibility: Tested per ISO 9000 standards. Manufacturing: Modified collagen application process. No software or electronic components.
Indications for Use
Indicated for patients requiring arterial replacement or repair due to aneurysmal or occlusive disease.
Regulatory Classification
Identification
A vascular graft prosthesis is an implanted device intended to repair, replace, or bypass sections of native or artificial vessels, excluding coronary or cerebral vasculature, and to provide vascular access. It is commonly constructed of materials such as polyethylene terephthalate and polytetrafluoroethylene, and it may be coated with a biological coating, such as albumin or collagen, or a synthetic coating, such as silicone. The graft structure itself is not made of materials of animal origin, including human umbilical cords.
Special Controls
*Classification.* Class II (special controls). The special control for this device is the FDA guidance document entitled “Guidance Document for Vascular Prostheses 510(k) Submissions.”
{0}
CONFIDENTIAL
# 510(K) SUMMARY OF SAFETY AND EFFECTIVENESS
## K954848
**Owner:**
Meadox Medicals, Inc.
112 Bauer Drive
Oakland, NJ 07436
(201) 337-6126
Fax # (201) 337-5797
FEB - 1 1996
**Contact Person:**
Carolyn Tauber
Senior Regulatory Affairs Specialist
**Submission Date:**
**Device Name:**
HEMASHIELD® CARDIOVASCULAR GRAFTS:
HEMASHIELD® MICROVEL® Double Velour Knitted Vascular Grafts
HEMASHIELD® Woven Double Velour Vascular Grafts
**Predicate Devices:**
HEMASHIELD® CARDIOVASCULAR GRAFTS:
HEMASHIELD® Knitted MICROVEL® Double Velour Vascular Grafts
(PMA #P840029, approved April 26, 1989)
HEMASHIELD® Woven Double Velour Vascular Grafts
(PMA #P840029/S5, approved May 11, 1993)
**Description of Device:**
The HEMASHIELD® CARDIOVASCULAR GRAFTS are knitted and woven polyester grafts, impregnated with bovine collagen.
**Intended Uses:**
For use in the replacement or repair of arteries affected with aneurysmal or occlusive disease, which is substantially equivalent to the currently marketed devices.
071
RG1014
{1}
CONFIDENTIAL
## Substantial Equivalence:
The proposed HEMASHIELD® MICROVEL® Double Velour Knitted and HEMASHIELD® Woven Double Velour Vascular Grafts have identical design, components, materials, intended use, and labeling to the currently marketed devices with PMA approval. The only difference between the proposed and the currently marketed devices is there are some modifications in the manufacturing process for the collagen component of the proposed devices. Testing has been performed which demonstrates that in spite of these modifications in the collagen manufacturing process, the proposed devices are substantially equivalent to the currently marketed PMA approved devices.
## Product Testing:
The following testing has been conducted on HEMASHIELD® MICROVEL® Double Velour Knitted and HEMASHIELD® Woven Double Velour Vascular Grafts to demonstrate the equivalency in safety and efficacy of these devices to their currently marketed PMA approved devices.
- Burst Strength - equivalent to marketed product
- Tensile Strength - equivalent to marketed product
- Suture Pull Out - equivalent to marketed product
- Wall Thickness - equivalent to marketed product
- Longitudinal Stretch - equivalent to marketed product
- Needle Penetration - equivalent to marketed product
- Crush Resistance - equivalent to marketed product
- Flexural Rigidity - equivalent to marketed product
- Integral Water Permeability - equivalent to marketed product
- Integral Water Permeability under load - equivalent to marketed product
- Strength of Collagen Bonding - equivalent to marketed product
- Shrinkage Temperature - equivalent to marketed product
- Glycerol Content - equivalent to marketed product
- Collagen Content - equivalent to marketed product
- Scanning Electron Micrographs - equivalent to marketed product
## Biocompatibility Testing:
Testing performed in accordance with ISO 9000 Standards indicates that the HEMASHIELD® Woven Double Velour and HEMASHIELD® MICROVEL® Double Velour Knitted Vascular Grafts with modifications in the manufacturing process for the collagen component are safe for their intended use and substantially equivalent in biocompatibility to the currently marketed PMA approved devices.
072
RG1014
{2}
DEPARTMENT OF HEALTH & HUMAN SERVICES
Public Health Service
Food and Drug Administration
9200 Corporate Boulevard
Rockville MD 20850
FEB - 1 1996
Ms. Carolyn Tauber
Senior Regulatory Affairs Specialist
Meadox Medicals, Inc.
112 Bauer Drive
Oakland, New Jersey 07436
Re: K954848
HEMASHIELD® MICROVEL® Double Velour Knitted and
HEMASHIELD® Woven Double Velour Vascular Grafts
Regulatory Class: II (two)
Product Code: 74MAL
Dated: October 20, 1995
Received: October 23, 1995
Dear Ms. Tauber:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments. You may, therefore, market the device, subject to the general controls provisions of the Federal Food, Drug, and Cosmetic Act (act). The general controls provisions of the act include requirements for registration, listing of devices, good manufacturing practices, and labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval) it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Good Manufacturing Practice for Medical Devices: General (GMP) regulation (21 CFR Part 820) and that, through periodic GMP inspections, FDA will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, the Food and Drug Administration (FDA) may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under section 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulation.
Under Section 522(a) of the act, manufacturers of certain types of devices identified by the Act or designated by FDA are required to conduct postmarket surveillance studies. FDA has
{3}
Page 2 - Ms. Carolyn Tauber
identified under Section 522(a)(1)(A) the device cleared for marketing by this letter as requiring postmarket surveillance.
Within thirty (30) days of first introduction or delivery for introduction of this device into interstate commerce you are required to submit to FDA certification of the date of introduction into interstate commerce, a detailed protocol which describes the postmarket surveillance study, and a detailed profile of the study's principal investigator that clearly establishes the qualifications and experience of the individual to conduct the proposed study. For your information, general guidance on preparing a protocol for a postmarket surveillance study is attached.
Submit five (5) copies to:
Center for Devices and Radiological Health
Postmarket Surveillance Studies Document Center
Suite 405 (HFE-544)
1801 Rockville Pike
Rockville, Maryland 20852
Within sixty (60) days of receipt of your protocol, FDA will either approve or disapprove it and notify you of the Agency's action in writing. You should not begin your postmarket surveillance study of this device until the protocol has been approved. Data generated under an unapproved protocol may not satisfy your obligation under section 522. Please note that you must continue to collect and report data needed to maintain compliance with Medical Device Reporting regulations (21 CFR 803).
Failure to certify accurately the date of initial introduction of your device into interstate commerce, to submit timely an acceptable protocol, or to undertake and complete and FDA approved postmarket surveillance study consistent with the protocol will be considered violations of section 522. In accordance with the Medical Device Amendments of 1992, failure of a manufacturer to meet its obligations under section 522 is a prohibited act under section 301(q)(1)(C) of the Act (21 U.S.C. 331 (q)(1)(C). Further, under section 502(t)(3) of the act (21 U.S.C. 352(t)(3)), a device is misbranded if there is a failure or refusal to comply with any requirement under section 522 of the act. Violations of sections 301 or 502 may lead to regulatory actions including seizure of your product, injunction, prosecution, or civil money penalties.
If you have questions specifically concerning postmarket surveillance study requirements, contact the Postmarket Surveillance Studies Branch at (301) 594-0639.
{4}
Page 3 - Ms. Carolyn Tauber
In addition, on August 16, 1993, the Final Rule for Device Tracking was published in the *Federal Register*, pages 43442-43455 (copy enclosed). Be advised that under Section 519(e) of the Act as amended by the Safe Medical Devices Act of 1990, FDA has identified the above device as a device which requires tracking. Because the device is subject to tracking, you are required to adopt a method of tracking that follows the devices through the distribution chain and then identifies and follows the patients who receive them. The specific requirement of the regulation are found in 21 CFR 821 as described in the August 16, 1993 *Federal Register* beginning on page 43447.
This letter immediately will allow you to begin marketing your device as described in your 510(k) premarket notification. An FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and permits your device to proceed to the market, but does not mean that FDA *approves* your device. Therefore, you may not promote or in any way represent your device or its labeling as being *approved* by FDA. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809 for *in vitro* diagnostic devices), promotion, or advertising, please contact the Office of Compliance, Promotion and Advertising Policy Staff (HFZ-302) at (301) 594-4639. Other general information on your responsibilities under the act may be obtained from the Division of Small Manufacturers Assistance at its toll free number (800) 638-2041 or at (301) 443-6597.
Sincerely yours,
*Thomas J. Callahan, Ph.D.*
Acting Director
Division of Cardiovascular, Respiratory and Neurological Devices
Office of Device Evaluation
Center for Devices and Radiological Health
Enclosures
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.