Flowable Restorative Material (KP-Flow LF, KP-Flow MF, KP-Flow HF)
K261695 · Guilin Kevin Peter Technology Co., Ltd. · EBF · Aug 31, 2026 · Dental
Device Facts
Record ID
K261695
Device Name
Flowable Restorative Material (KP-Flow LF, KP-Flow MF, KP-Flow HF)
Applicant
Guilin Kevin Peter Technology Co., Ltd.
Product Code
EBF · Dental
Decision Date
Aug 31, 2026
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 872.3690
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
This product can be used for direct restoration of anterior and posterior. Indications: - Direct Restoration of all cavity classes (I-V) - Base/liner under direct restorations - Repair of small defects in esthetic indirect restorations - Repair of resin and acrylic temporary materials - Pit and fissure sealant
Device Story
KP-Flow is a light-cured composite resin filling material; used for direct restoration of anterior and posterior teeth; available in various shades (dentin, tooth, enamel, transparent); packaged in syringes. Clinician applies material intra-orally; light-curing initiates polymerization; provides structural restoration of tooth cavities; repairs defects in indirect restorations or temporary materials; acts as pit and fissure sealant. Radiopaque properties allow visualization on dental radiographs. Benefits include esthetic restoration and structural repair of dental tissues.
Clinical Evidence
No clinical data. Substantial equivalence supported by in-vitro bench testing per ISO 4049:2019 and ISO 6874:2015, including sensitivity to ambient light, depth of cure, flexural strength/modulus, water sorption/solubility, shade stability, and radio-opacity. Biocompatibility verified per ISO 10993 series (cytotoxicity, sensitization, irritation, systemic toxicity, genotoxicity).
Technological Characteristics
Light-cured composite resin; contains BisEMA, BisGMA, UDMA, TEGDMA, barium silanized glass, zirconia/silica cluster filler, silica filler, pigments, photo-initiators, stabilizers. Filler loading: 53-69% wt; particle size 0.6-10 μm. Radiopaque. Syringe delivery. Complies with ISO 4049:2019, ISO 6874:2015, ISO 10993 series, and ISO 7405.
Indications for Use
Indicated for direct restoration of all cavity classes (I-V), base/liner under direct restorations, repair of small defects in esthetic indirect restorations, repair of resin and acrylic temporary materials, and pit and fissure sealant in patients requiring dental restorative procedures.
Regulatory Classification
Identification
Tooth shade resin material is a device composed of materials such as bisphenol-A glycidyl methacrylate (Bis-GMA) intended to restore carious lesions or structural defects in teeth.
{0}
**FDA** U.S. FOOD & DRUG
ADMINISTRATION
August 31, 2026
Guilin Kevin Peter Technology Co., Ltd.
Qian Zhang
RA Registration
North Side Of Linsu Rd., Lingui Town, Lingui Dist.
Guilin, Guangxi 541100
CHINA
Re: K261695
Trade/Device Name: Flowable Restorative Material (KP-Flow LF, KP-Flow MF, KP-Flow HF)
Regulation Number: 21 CFR 872.3690
Regulation Name: Tooth Shade Resin Material
Regulatory Class: Class II
Product Code: EBF, EBC
Dated: May 22, 2026
Received: May 22, 2026
Dear Qian Zhang:
We have reviewed your section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (the Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database available at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
U.S. Food & Drug Administration
10903 New Hampshire Avenue
Silver Spring, MD 20993
www.fda.gov
{1}
K261695 - Qian Zhang
Page 2
Additional information about changes that may require a new premarket notification are provided in the FDA guidance documents entitled "Deciding When to Submit a 510(k) for a Change to an Existing Device" (https://www.fda.gov/media/99812/download) and "Deciding When to Submit a 510(k) for a Software Change to an Existing Device" (https://www.fda.gov/media/99785/download).
Your device is also subject to, among other requirements, the Quality Management System Regulation (QMSR) (21 CFR Part 820), which includes, but is not limited to, ISO 13485 clause 7.3 (Design controls), ISO 13485 clause 8.3 (Nonconforming product), ISO 13485 clause 8.5.2 (Corrective action), and ISO 13485 clause 8.5.3 (Preventative action). Please note that regardless of whether a change requires premarket review, the QMSR requires device manufacturers to review and approve changes to device design and production (ISO 13485 clause 7.3 and ISO 13485 clause 7.5) and document changes and approvals in the Medical Device File (ISO 13485 clause 4.2.3).
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR Part 803) for devices or postmarketing safety reporting (21 CFR Part 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reporting-combination-products); good manufacturing practice requirements as set forth in the Quality Management System Regulation (QMSR) (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR Part 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR Parts 1000-1050.
All medical devices, including Class I and unclassified devices and combination product device constituent parts are required to be in compliance with the final Unique Device Identification System rule ("UDI Rule"). The UDI Rule requires, among other things, that a device bear a unique device identifier (UDI) on its label and package (21 CFR 801.20(a)) unless an exception or alternative applies (21 CFR 801.20(b)) and that the dates on the device label be formatted in accordance with 21 CFR 801.18. The UDI Rule (21 CFR 830.300(a) and 830.320(b)) also requires that certain information be submitted to the Global Unique Device Identification Database (GUDID) (21 CFR Part 830 Subpart E). For additional information on these requirements, please see the UDI System webpage at https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/unique-device-identification-system-udi-system.
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-devices/medical-device-safety/medical-device-reporting-mdr-how-report-medical-device-problems.
For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-
{2}
K261695 - Qian Zhang
Page 3
assistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).
Sincerely,
# MICHAEL E. ADJODHA -S
Michael E. Adjodha, MChE, RAC, CQIA
Assistant Director
DHT1B: Division of Dental and
ENT Devices
OHT1: Office of Ophthalmic, Anesthesia,
Respiratory, ENT, and Dental Devices
Office of Product Evaluation and Quality
Center for Devices and Radiological Health
Enclosure
{3}
DEPARTMENT OF HEALTH AND HUMAN SERVICES
Food and Drug Administration
# Indications for Use
Form Approved: OMB No. 0910-0120
Expiration Date: 06/30/2023
See PRA Statement below.
510(k) Number (if known)
K261695
Device Name
Flowable Restorative Material (KP-Flow LF, KP-Flow MF, KP-Flow HF)
Indications for Use (Describe)
Intended purpose: This product can be used for direct restoration of anterior and posterior.
Indications:
- Direct Restoration of all cavity classes (I-V)
- Base/liner under direct restorations
- Repair of small defects in esthetic indirect restorations
- Repair of resin and acrylic temporary materials
- Pit and fissure sealant
Type of Use (Select one or both, as applicable)
☑
Prescription Use (Part 21 CFR 801 Subpart D)
☐
Over-The-Counter Use (21 CFR 801 Subpart C)
# CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
# *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
Department of Health and Human Services
Food and Drug Administration
Office of Chief Information Officer
Paperwork Reduction Act (PRA) Staff
PRAStaff@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
FORM FDA 3881 (6/20)
Page 1 of 1
PSC Publishing Services (301) 443-6740
EF
{4}
K261695
[LOGO]
桂林凯文彼德科技有限公司
Guilin Kevin Peter Technology Co., Ltd.
# 510(k) Summary
This summary of 510(k) substantial equivalence is being submitted in accordance with requirements of 21 CFR 807.92.
## 1 Submitter's Information
Name: Guilin Kevin Peter Technology Co., Ltd.
Address: North Side of Linsu Rd, Lingui Town, Lingui Dist., Guilin, Guangxi, 541100, P. R. China
Tel: +86-773-2352685
Contact: Zhang Qian
## Designated Submission Correspondent
Mrs. Zhang Qian
Guilin Kevin Peter Technology Co., Ltd.
Address: North Side of Linsu Rd, Lingui Town, Lingui Dist., Guilin, Guangxi, 541100, P. R. China
Tel: +86-773-2352685
Email: rcd05@kvpeter.com
Date of Preparation: Sep.25,2024
## 2 Device Information
Trade Name: KP-Flow Flowable Restorative Material
Device Name: Flowable Restorative Material
Common Name: Tooth Shade Resin Material
Classification Name: Material, Tooth Shade, Resin
Model: KP-Flow LF, KP-Flow MF, KP-Flow HF
## 3 Classification
Production code: EBF
Regulation number: 21 CFR 872.3690
Classification: Class II
Panel: Dental
## 4 Identification of Predicate Device
1 of page 7
{5}
[LOGO]
桂林凯文彼德科技有限公司
Guilin Kevin Peter Technology Co., Ltd.
Predicate Device:
510(k) Number: K221695
Device Name: Filtek™ Supreme Flowable Restorative
Manufacturer: 3M COMPANY ESPE Dental Products
### 5 Indication for Use Statement
Intended purpose: This product can be used for direct restoration of anterior and posterior.
Indications:
- Direct Restoration of all cavity classes (I-V)
- Base/liner under direct restorations
- Repair of small defects in esthetic indirect restorations
- Repair of resin and acrylic temporary materials
- Pit and fissure sealant
### 6 Device Description
KP-Flow Flowable Restorative Material is a kind of composite resin filling material that can be cured by visible light for the filling and restoration of anterior teeth and posterior teeth.
The product is available in a variety of colors, such as dentin color, tooth color, enamel color, transparent color and other colors. All shades are radiopaque. It is a class 2 product whose use requires the energy to be applied intra-orally. It is packaged in syringes.
### 7 Summary of Non-Clinical Testing
Non clinical tests were conducted to verify that the proposed device met all design specifications as was Substantially Equivalent (SE) to the predicate device. The test results demonstrated that the proposed device complies with the FDA-Recognized Standard ISO 4049:2019 Dentistry - Polymer-based restorative materials and FDA guidance “Guidance for Industry and FDA Staff Dental Composite Resin Devices-Premarket Notification [510(k)]Submissions Document, issued on October 26, 2005”.
2 of page 7
{6}
hp
桂林凯文彼德科技有限公司
Guilin Kevin Peter Technology Co., Ltd.
In-vitro bench tests were performed on the KP-Flow Flowable Restorative Material including the items listed in the table below. The test results indicated that the KP-Flow Flowable Restorative Material meets the pass criteria and supports substantial equivalence when compared to the predicate device on physical properties.
| Items | Acceptable criteria | Conclusion |
| --- | --- | --- |
| ISO 4049: 2019 5.2.7 Sensitivity to ambient light, Class 2 materials | The material shall remain physically homogeneous. | Meet the criteria per ISO 4049 |
| ISO 4049: 2019 5.2.8 Depth of cure, Class 2 materials ISO 6874:2015 , 4.2.3 Depth of cure, Class 2 Sealant | All restorative materials: ≥1.5 mm | Meet the criteria per ISO 4049 , ISO 6874 |
| ISO 4049: 2019 5.2.9 Flexural strength and Flexural Modulus | The flexural strength shall be equal to or greater than 50 MPa | Meet the criteria per ISO 4049 |
| ISO 4049: 2019 5.2.10 Water sorption and solubility | 1) The water sorption shall be ≤40μg/mm32) The solubility shall be shall be ≤7.5μg/mm3 | Meet the criteria per ISO 4049 |
| ISO 4049: 2019 5.3 Shade of restorative materials | When the material is assessed in accordance with 7.13 and ISO 7491, the shade of the set material shall closely match that of the manufacturer's shade guide. The set material shall be evenly pigmented when viewed without magnification | Meet the criteria per ISO 4049 |
3 of page 7
{7}
桂林凯文彼德科技有限公司
Guilin Kevin Peter Technology Co., Ltd.
| ISO 4049: 2019 5.4 Colour stability after irradiation and water sorption | The set material shall be evenly pigmented when viewed without magnification | Meet the criteria per ISO 4049 |
| --- | --- | --- |
| ISO 4049: 2019 Radio-opacity | The radio-opacity shall be equal to or greater than that of the same thickness of aluminium (1 mm of material) | Meet the criteria per ISO 4049 |
| FDA guidance Elastic modulus | The test results of the subject device's elastic modulus showed no significant difference from those of the predicate device | Meet the requirements of FDA guidance |
| FDA guidance Surface hardness | The test results of the subject device's surface hardness showed no significant difference from those of the predicate device | Meet the requirements of FDA guidance |
| FDA guidance Compressive strength | The test results of the subject device's compressive strength showed no significant difference from those of the predicate device | Meet the requirements of FDA guidance |
### Biocompatibility Testing:
Biocompatibility tests were performed fully following the ISO 10993-1 and ISO 7405 standards.
The test items include:
4 of page 7
{8}
K
桂林凯文彼德科技有限公司
Guilin Kevin Peter Technology Co., Ltd.
- In Vitro Cytotoxicity Test - ISO 10993-5:2009 Biological evaluation of medical devices - Part 5: Tests for in vitro cytotoxicity
- Sensitization - ISO 10993-10:2021 Biological evaluation of medical devices - Part 10: Tests for irritation and skin sensitization
- Intracutaneous Reactivity Test - ISO 10993-23:2021 Biological evaluation of medical devices - Part 10: Tests for irritation and skin sensitization
- Acute systemic Toxicity Test - ISO 10993-11:2017 Biological evaluation of medical devices - Part 11: Tests for systemic toxicity
- Subchronic systemic Toxicity Test - ISO 10993-11:2017 Biological evaluation of medical devices - Part 11: Tests for systemic toxicity
- Bacterial Reverse Mutation Test - ISO 10993-3:2014 Biological evaluation of medical devices - Part 3: Tests for genotoxicity, carcinogenicity and reproductive toxicity.
- Mouse Lymphoma Cells(TK) Gene Mutation Test- ISO 10993-3:2014 Biological evaluation of medical devices - Part 3: Tests for genotoxicity, carcinogenicity and reproductive toxicity.
- In vitro Mammalian Chromosome Aberration Test - ISO 10993-3:2014 Biological evaluation of medical devices - Part 3: Tests for genotoxicity, carcinogenicity and reproductive toxicity.
## 8 Summary of Clinical Testing
Clinical testing was not required for this submission.
## 9 Technological Characteristics and Substantial Equivalence
The following table shows similarities and differences of use, design, and material between our device and the predicate devices.
Table 1 General Device Characteristics Comparison Table
| Item | Subject device | Predicate deviceK 221695 |
| --- | --- | --- |
| Product Name | KP-Flow Flowable Restorative Material | FiltekTM Supreme Flowable Restorative |
| Product Code | EBF | EBF |
5 of page 7
{9}
hp
桂林凯文彼德科技有限公司
Guilin Kevin Peter Technology Co., Ltd.
| Regulation No. | 21 CFR 872.3690 | 21 CFR 872.3690 |
| --- | --- | --- |
| Class | II | II |
| Intended Use | Indications for Use:Direct restoration of all cavity classes (I-V)Base/liner under direct restorationsRepair of small defects in esthetic indirect restorationsRepair of resin and acrylic temporary materialsPit and fissure sealant | Indications for Use:Direct Restoration of all cavity classes (I-V)Base/liner under direct restorationsRepair of small defects in esthetic indirect restorationsRepair of resin and acrylic temporary materialsPit and fissure sealant. |
| Prescription Use | Yes | Yes |
| Composition of Materials | BisEMA, BisGMA, UDMA, TEGDMA, barium silanized glass, zirconia/silica cluster filler, silica filler, pigments, photo-initiators and stabilizers.KP-Flow LF: The inorganic filler loading is about 65%, particle size is between 0.6μm and 10 μm.KP-Flow MF: The inorganic filler loading is about 69% by wt for the Bulk Fill shades and 63.5% by wt for all other shades.The particle size of inorganic fillers is between 0.6μm and 10 μm.KP-Flow HF: The inorganic filler loading is about 53%, particle size is between 0.6μm and 10 μm. | BisGMA, TEGDMA and Procrylat resins. The fillers are a combination of ytterbiumn trifluoride filler with a range of particles sizes from 0.1 to 5.0 microns, a non-agglomerated/non-aggregated surface modified 20nm silica filler, a non-agglomerated/non-aggregated surface modified 75nm silica filler, and a surface modified aggregated zirconia/silica cluster filler (comprised of 20 nm silica and 4 to 11 nm zirconia particles). The aggregate has an average cluster particle size of 0.6 to 10 microns. The inorganic filler loading is approximately 65% by weight (46% by volume). |
6 of page 7
{10}
桂林凯文彼德科技有限公司
Guilin Kevin Peter Technology Co., Ltd.
| Curing method | Light cure | Light cure |
| --- | --- | --- |
| Delivery form | Syringe | Capsules and Syringes. |
| Physical Properties | The subject device and the predicate device have substantially equivalent physical properties including compressive strength, flexural strength, Diametral Tensile Strength, Flexural Modulus, depth of cure, surface hardness, radio-opacity, water sorption and solubility as they all meet the criteria per ISO 4049 and FDA guidance “Guidance for Industry and FDA Staff Dental Composite Resin Devices-Premarket Notification[510(k)] Submissions Document issued on October 26,2005”. | |
| FDA-Recognized Standards | ISO 4049, ISO 6874, ISO 7405, ISO 10993-1, ISO 10993-3, ISO 10993-5, ISO 10993-10, ISO 10993-23 | ISO 4049, ISO 6874, ISO 7405, ISO 10993-1, ISO 10993-3,ISO 10993-5, ISO 10993-10, ISO 10993-23 |
The subject device has same intended use, incorporates the same fundamental technology, and has same indications for use as the predicate device,both products are intended for direct anterior and posterior restorations.
The technological characteristics of the subject device are very similar to those of the predicate device, Physical property comparison data support substantial equivalence of the subject device when compared to the predicate device.
# 10 Conclusion
The conclusions drawn from the comparison and analysis above demonstrate that the differences between the subject device and the predicat device are insignificant in terms of substantial equivalence. The subject device is substantially equivalent to the predicate device.
7 of page 7
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.