ePM Series Patient Monitor (ePM 10/ePM 10A/ePM 10C/Guardian plus/ ePM 12/ePM 12A/ePM 12C / ePM 15/ePM 15A/ePM 15C /ePM 10M/ ePM 10MA/ ePM 10MC/ePM 12M/ ePM 12MA/ ePM 12MC/ePM 15M/ ePM 15MA/ ePM 15MC)

K260098 · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · MHX · May 20, 2026 · Cardiovascular

Device Facts

Record IDK260098
Device NameePM Series Patient Monitor (ePM 10/ePM 10A/ePM 10C/Guardian plus/ ePM 12/ePM 12A/ePM 12C / ePM 15/ePM 15A/ePM 15C /ePM 10M/ ePM 10MA/ ePM 10MC/ePM 12M/ ePM 12MA/ ePM 12MC/ePM 15M/ ePM 15MA/ ePM 15MC)
ApplicantShenzhen Mindray Bio-Medical Electronics Co., Ltd.
Product CodeMHX · Cardiovascular
Decision DateMay 20, 2026
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 870.1025
Device ClassClass 2
AttributesPediatric

Indications for Use

The ePM 10/ePM 10A/ePM 10C/Guardian plus/ ePM 12/ePM 12A/ePM 12C / ePM 15/ePM 15A/ePM 15C /ePM 10M/ ePM 10MA/ ePM 10MC/ePM 12M/ ePM 12MA/ ePM 12MC/ePM 15M/ ePM 15MA/ ePM 15MC patient monitors are intended for monitoring, displaying, reviewing, storing, alarming, and transferring of multiple physiological parameters including ECG (3-lead, 5-lead, 6-lead or 12-lead selectable, Arrhythmia Detection, ST Segment Analysis, QT Analysis, and Heart Rate (HR)), Respiration Rate (Resp), Temperature (Temp), Pulse Oxygen Saturation (SpO2), Pulse Rate (PR), Non- invasive Blood Pressure (NIBP), Invasive Blood Pressure (IBP), Pulmonary Artery Wedge Pressure (PAWP), Cardiac Output (C.O.), Carbon Dioxide (CO2), Oxygen (O2) and Anesthetic Gas (AG), Bispectral Index (BIS), Neuromuscular Transmission Monitoring (NMT). The system also provides an interpretation of resting 12-lead ECG. All the parameters can be monitored on single adult, pediatric, and neonatal patients except for the following: • NMT, the PAWP monitoring is intended for adult and pediatric patients only; • BIS monitoring is only intended for patients aged 4 years and above; • C.O. monitoring is intended for adult and pediatric patients. The monitors are to be used in healthcare facilities by clinical professionals or under their guidance. They should only be used by persons who have received adequate training in their use. The ePM 10/10A/10C/ Guardian plus/ ePM 12/ePM 12A/ePM 12C / ePM 15/ePM 15A/ePM 15C /ePM 10M/ ePM 10MA/ ePM 10MC/ePM 12M/ ePM 12MA/ ePM 12MC/ePM 15M/ ePM 15MA/ ePM 15MC monitors are not intended for helicopter transport, hospital ambulance, or home use.

Device Story

ePM Series Patient Monitors are multi-parameter bedside systems for clinical environments. They acquire physiological signals (ECG, SpO2, NIBP, IBP, CO2, etc.) via integrated or external modules. The device processes these signals to display waveforms, calculate parameters (e.g., HR, ST-segment, QT, cardiac output), and trigger alarms. It supports 12-lead ECG interpretation and integrates with third-party devices via RS-232. Clinicians use the touchscreen interface to review data and manage patient monitoring. The system aids clinical decision-making by providing real-time vital sign monitoring and automated analysis, facilitating timely intervention. It is intended for use in healthcare facilities by trained professionals.

Clinical Evidence

No clinical data provided. Substantial equivalence is supported by bench testing, including electrical safety (IEC 60601-1), EMC (IEC 60601-1-2), and performance testing against recognized consensus standards for each monitored parameter (e.g., ECG, SpO2, NIBP, IBP, CO2, temperature, and alarm systems).

Technological Characteristics

Multi-parameter patient monitor; modular design (internal/external modules); touchscreen display (10.1"-15.6"); connectivity via wireless (2.4G/5G) and RS-232; power via AC or Li-ion batteries. Software-based signal processing for ECG (arrhythmia/ST/QT/12-lead interpretation), NIBP (oscillometric), SpO2, and hemodynamic calculations. Complies with IEC 60601-1, IEC 60601-1-2, and parameter-specific standards (e.g., ISO 80601-2-61, IEC 60601-2-27).

Indications for Use

Indicated for monitoring physiological parameters (ECG, Resp, Temp, SpO2, PR, NIBP, IBP, PAWP, C.O., CO2, O2, AG, BIS, NMT) and resting 12-lead ECG interpretation in adult, pediatric, and neonatal patients. Contraindications: NMT/PAWP (neonates), BIS (patients <4 years), C.O. (neonates). For use in healthcare facilities by trained clinical professionals.

Regulatory Classification

Identification

The arrhythmia detector and alarm device monitors an electrocardiogram and is designed to produce a visible or audible signal or alarm when atrial or ventricular arrhythmia, such as premature contraction or ventricular fibrillation, occurs.

Special Controls

*Classification.* Class II (special controls). The guidance document entitled “Class II Special Controls Guidance Document: Arrhythmia Detector and Alarm” will serve as the special control. See § 870.1 for the availability of this guidance document.

Predicate Devices

Submission Summary (Full Text)

{0} ![LOGO](FDA U.S. FOOD & DRUG ADMINISTRATION) May 20, 2026 Shenzhen Mindray Bio-Medical Electronics Co., Ltd. Li Lei Technical Regulation Manager Mindray Bldg., Keji 12th Rd. S. Hi-Tech Industrial Park, Nanshan Shenzhen, Guangdong 518057 China Re: K260098 Trade/Device Name: ePM Series Patient Monitor (ePM 10/ePM 10A/ePM 10C/Guardian plus/ ePM 12/ePM 12A/ePM 12C / ePM 15/ePM 15A/ePM 15C /ePM 10M/ ePM 10MA/ ePM 10MC/ePM 12M/ ePM 12MA/ ePM 12MC/ePM 15M/ ePM 15MA/ ePM 15MC) Regulation Number: 21 CFR 870.1025 Regulation Name: Arrhythmia Detector And Alarm (Including ST-Segment Measurement And Alarm) Regulatory Class: Class II Product Code: MHX, DSI, MLD, DRT, DXN, DSK, FLL, DQA, DPZ, CCK, DXG, DSJ, CBQ, CBS, CBR, CCL, KOI, OLW, OLT, OMC, ORT, GXY Dated: April 22, 2026 Received: April 22, 2026 Dear Li Lei: We have reviewed your section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (the Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database available at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of U.S. Food & Drug Administration 10903 New Hampshire Avenue Silver Spring, MD 20993 www.fda.gov {1} K260098 - Li Lei Page 2 Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Additional information about changes that may require a new premarket notification are provided in the FDA guidance documents entitled 'Deciding When to Submit a 510(k) for a Change to an Existing Device' (https://www.fda.gov/media/99812/download) and 'Deciding When to Submit a 510(k) for a Software Change to an Existing Device' (https://www.fda.gov/media/99785/download). Your device is also subject to, among other requirements, the Quality Management System Regulation (QMSR) (21 CFR Part 820), which includes, but is not limited to, ISO 13485 clause 7.3 (Design controls), ISO 13484 clause 8.3 (Nonconforming product), and ISO 13485 clause 8.5 (Corrective and preventative action). Please note that regardless of whether a change requires premarket review, the QMSR requires device manufacturers to review and approve changes to device design and production (ISO 13485 clause 7.3 and 21 CFR 820.70) and document changes and approvals in the device master record (21 CFR 820.181). Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR Part 803) for devices or postmarketing safety reporting (21 CFR Part 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reporting-combination-products); good manufacturing practice requirements as set forth in the Quality Management System Regulation (QMSR) (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR Part 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR Parts 1000-1050. All medical devices, including Class I and unclassified devices and combination product device constituent parts are required to be in compliance with the final Unique Device Identification System rule ('UDI Rule'). The UDI Rule requires, among other things, that a device bear a unique device identifier (UDI) on its label and package (21 CFR 801.20(a)) unless an exception or alternative applies (21 CFR 801.20(b)) and that the dates on the device label be formatted in accordance with 21 CFR 801.18. The UDI Rule (21 CFR 830.300(a) and 830.320(b)) also requires that certain information be submitted to the Global Unique Device Identification Database (GUDID) (21 CFR Part 830 Subpart E). For additional information on these requirements, please see the UDI System webpage at https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/unique-device-identification-system-udi-system. Also, please note the regulation entitled, 'Misbranding by reference to premarket notification' (21 CFR 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-devices/medical-device-safety/medical-device-reporting-mdr-how-report-medical-device-problems. For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the {2} K260098 - Li Lei Page 3 Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100). Sincerely, **JENNIFER W. SHIH -S** Jennifer Kozen Assistant Director Division of Cardiac Electrophysiology, Diagnostics, and Monitoring Devices Office of Cardiovascular Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health Enclosure {3} # Indications for Use | Please type in the marketing application/submission number, if it is known. This textbox will be left blank for original applications/submissions. | K260098 | ? | | --- | --- | --- | | Please provide the device trade name(s). | | ? | | ePM Series Patient Monitor (ePM 10/ePM 10A/ePM 10C/Guardian plus/ ePM 12/ePM 12A/ePM 12C / ePM 15/ePM 15A/ePM 15C /ePM 10M/ ePM 10MA/ ePM 10MC/ePM 12M/ ePM 12MA/ ePM 12MC/ePM 15M/ ePM 15MA/ ePM 15MC) | | | | Please provide your Indications for Use below. | | ? | | The ePM 10/ePM 10A/ePM 10C/Guardian plus/ ePM 12/ePM 12A/ePM 12C / ePM 15/ePM 15A/ePM 15C / ePM 10M/ ePM 10MA/ ePM 10MC/ePM 12M/ ePM 12MA/ ePM 12MC/ePM 15M/ ePM 15MA/ ePM 15MC patient monitors are intended for monitoring, displaying, reviewing, storing, alarming, and transferring of multiple physiological parameters including ECG (3-lead, 5-lead, 6-lead or 12-lead selectable, Arrhythmia Detection, ST Segment Analysis, QT Analysis, and Heart Rate (HR)), Respiration Rate (Resp), Temperature (Temp), Pulse Oxygen Saturation (SpO2), Pulse Rate (PR), Non- invasive Blood Pressure (NIBP), Invasive Blood Pressure (IBP), Pulmonary Artery Wedge Pressure (PAWP), Cardiac Output (C.O.), Carbon Dioxide (CO2), Oxygen (O2) and Anesthetic Gas (AG), Bispectral Index (BIS), Neuromuscular Transmission Monitoring (NMT). The system also provides an interpretation of resting 12-lead ECG. | | | | All the parameters can be monitored on single adult, pediatric, and neonatal patients except for the following: | | | | • NMT, the PAWP monitoring is intended for adult and pediatric patients only; • BIS monitoring is only intended for patients aged 4 years and above; • C.O. monitoring is intended for adult and pediatric patients. | | | | The monitors are to be used in healthcare facilities by clinical professionals or under their guidance. They should only be used by persons who have received adequate training in their use. The ePM 10/10A/10C/ Guardian plus/ ePM 12/ePM 12A/ePM 12C / ePM 15/ePM 15A/ePM 15C /ePM 10M/ ePM 10MA/ ePM 10MC/ePM 12M/ ePM 12MA/ ePM 12MC/ePM 15M/ ePM 15MA/ ePM 15MC monitors are not intended for helicopter transport, hospital ambulance, or home use. | | | | Please select the types of uses (select one or both, as applicable). | ☑ Prescription Use (21 CFR 801 Subpart D) ☐ Over-The-Counter Use (21 CFR 801 Subpart C) | ? | {4} 510(k) Summary Shenzhen Mindray Bio-Medical Electronics K260098 # **1. SUBMITTER INFORMATION** Applicant: SHENZHEN MINDRAY BIO-MEDICAL ELECTRONICS CO., LTD. Contact: Li Lei Phone: +86 755 81885953 Email: lilei.js@mindray.com Address: Mindray Building, Keji 12th Road South Hi-tech Industrial Park, Nanshan Shenzhen Guangdong 518057, China # **2. CORRESPONDENT INFORMATION** Contact: Li Lei Title: Manager, Technical Regulations Department Firm: Shenzhen Mindray Bio-Medical Electronics Co., Ltd. Phone: +86 755 81885953 Email: lilei.js@mindray.com # **3. DATE PREPARED: APRIL 14, 2026** # **4. DEVICE INFORMATION** Device Name: ePM Series Patient Monitor Common Name: Patient Monitor Regulation Number: 21 CFR 870.1025 Regulation Name: Arrhythmia detector and alarm (including ST-segment measurement and alarm) Product Code: MHX Regulatory Class: 2 **Table 1: Secondary Product Codes** | Regulation Number/Class | Product Code | Regulation description | Device Common Name | | --- | --- | --- | --- | | 870.1025, II | DSI | Arrhythmia detector and alarm (including ST-segment measurement and alarm) | Detector and alarm, arrhythmia | Page 1 of 8 {5} 510(k) Summary Shenzhen Mindray Bio-Medical Electronics K260098 | Regulation Number/Class | Product Code | Regulation description | Device Common Name | | --- | --- | --- | --- | | 870.1025, II | MLD | Arrhythmia detector and alarm (including ST-segment measurement and alarm) | Monitor, st segment with alarm | | 870.2300, II | DRT | Cardiac Monitor (including cardiotachometer and rate alarm) | Monitor, cardiac (incl. cardiotachometer & rate alarm) | | 870.1130, II | DXN | Noninvasive blood pressure measurement system | System, measurement, blood-pressure, non-invasive | | 870.1110, II | DSK | Blood pressure computer | Computer, blood-pressure | | 880.2910, II | FLL | Clinical electronic thermometer | Thermometer, electronic, clinical | | 870.2700, II | DQA | Oximeter | Oximeter | | 870.2710, II | DPZ | Ear oximeter | Oximeter, ear | | 868.1400, II | CCK | Carbon dioxide gas analyzer | Analyzer, gas, carbon-dioxide, gaseous-phase | | 870.1435, II | DXG | Single-function, preprogrammed diagnostic computer | Computer, diagnostic, pre-programmed, single-function | | 870.1100, II | DSJ | Blood pressure alarm | Alarm, blood-pressure | | 868.1500, II | CBQ | Enflurane gas analyzer | Analyzer, gas, enflurane, gaseous-phase (anesthetic concentration) | | 868.1620, II | CBS | Halothane gas analyzer | Analyzer, gas, halothane, gaseous-phase (anesthetic conc.) | | 868.1700, II | CBR | Nitrous oxide gas analyzer | Analyzer, gas, nitrous-oxide, gaseous phase (anesthetic conc.) | | 868.1720, II | CCL | Oxygen gas analyzer | Analyzer, gas, oxygen, gaseous-phase | | 868.2775, II | KOI | Electrical peripheral nerve stimulator. | Stimulator, nerve, peripheral, electric | | 882.1400, II | OLW | Electroencephalograph. | Index-generating electroencephalograph software | | 882.1400, II | OLT | Electroencephalograph | Non-normalizing quantitative electroencephalograph software | Page 2 of 8 {6} 510(k) Summary Shenzhen Mindray Bio-Medical Electronics K260098 | Regulation Number/Class | Product Code | Regulation description | Device Common Name | | --- | --- | --- | --- | | 882.1400, II | OMC | Electroencephalograph. | Reduced- montage standard electroencephalograph | | 882.1400, II | ORT | Electroencephalograph | Burst suppression detection software for electroencephalograph | | 882.1320, II | GXY | Cutaneous electrode. | Electrode, cutaneous | ## 5. PREDICATE DEVICE INFORMATION Primary Predicate Device Name: ePM Series Patient Monitor 510(k) Number: K200015 Manufacturer: Shenzhen Mindray Bio-Medical Electronics Co., Ltd. ## 6. DEVICE DESCRIPTION The subject devices are the ePM Series Patient Monitors family, which consists of the 19 monitors identified in Table 2. **Table 2 Overview of ePM-series monitors** | ePM-Series Patient Monitor Model | Description | | --- | --- | | ePM 10M/10MA/10MC ePM 12M/12MA/12MC ePM 15M/15MA/15MC | ePM 10M / 10MA / 10MC / 12M / 12MA / 12MC / 15M / 15MA / 15MC consist of the main unit, internal modules, external modules, input devices, output devices, an internal rack, a Satellite Module Rack. | | ePM 10/10A/10C/Guardian plus ePM 12/12A/12C ePM 15/15A/15C | ePM 10/10A/10C/Guardian plus/12/12A/12C/15/15A/15C consist of the main unit, internal modules, input devices, and output devices. | The differences between the ePM 10M/10MA/10MC, ePM 12M/12MA/12MC, and ePM 15M/15MA/15MC include the display size and resolution, the configuration of built-in CO2 module, the number of batteries, and the AC-power module. The differences between the xxM/xxMA/xxMC models include the base, rear cover color and the work mode. The differences between the ePM 10/10A/10C/Guardian plus, ePM 12/12A/12C and ePM 15/15A/15C consist of the display size and the number of batteries. The differences between the xx/xxA/xxC/Guardian plus models include the base, rear cover color and the work mode. All the other hardware and software is the same. Page 3 of 8 {7} 510(k) Summary Shenzhen Mindray Bio-Medical Electronics K260098 ## 7. INDICATIONS FOR USE The indications for use statement for the ePM Series Patient Monitors is provided below. The ePM 10/ePM 10A/ePM 10C/Guardian plus/ ePM 12/ePM 12A/ePM 12C / ePM 15/ePM 15A/ePM 15C /ePM 10M/ ePM 10MA/ ePM 10MC/ePM 12M/ ePM 12MA/ ePM 12MC/ePM 15M/ ePM 15MA/ ePM 15MC patient monitors are intended for monitoring, displaying, reviewing, storing, alarming, and transferring of multiple physiological parameters including ECG (3-lead, 5-lead, 6-lead or 12-lead selectable, Arrhythmia Detection, ST Segment Analysis, QT Analysis, and Heart Rate (HR)), Respiration Rate (Resp), Temperature (Temp), Pulse Oxygen Saturation (SpO2), Pulse Rate (PR), Non- invasive Blood Pressure (NIBP), Invasive Blood Pressure (IBP), Pulmonary Artery Wedge Pressure (PAWP), Cardiac Output (C.O.), Carbon Dioxide (CO2), Oxygen (O2) and Anesthetic Gas (AG), Bispectral Index (BIS), Neuromuscular Transmission Monitoring (NMT). The system also provides an interpretation of resting 12-lead ECG. All the parameters can be monitored on single adult, pediatric, and neonatal patients except for the following: - NMT, the PAWP monitoring is intended for adult and pediatric patients only; - BIS monitoring is only intended for patients aged 4 years and above; - C.O. monitoring is intended for adult and pediatric patients. The monitors are to be used in healthcare facilities by clinical professionals or under their guidance. They should only be used by persons who have received adequate training in their use. The ePM 10/10A/10C/ /Guardian plus/ ePM 12/ePM 12A/ePM 12C / ePM 15/ePM 15A/ePM 15C /ePM 10M/ ePM 10MA/ ePM 10MC/ePM 12M/ ePM 12MA/ ePM 12MC/ePM 15M/ ePM 15MA/ ePM 15MC monitors are not intended for helicopter transport, hospital ambulance, or home use. ## 8. COMPARISON OF INTENDED USE AND TECHNOLOGICAL CHARACTERISTICS WITH THE PREDICATE DEVICE Table 3 provides a comparison of the technological features of system compared to the predicate system in K200015. Page 4 of 8 {8} 510(k) Summary Shurzhen Mindray Bio-Medical Electronics K260098 Table 3: Device Comparison Table | Feature | cPM 10 | cPM 12 | cPM 15 | cPM 10M | cPM 12M | cPM 15M | cPM 10 / 10A / 10C / Guardian plus | cPM 12 / 12A / 12C | cPM 15 / 15A / 15C | cPM 10M / 10MA / 10MC | cPM 12M / 12MA / 12MC | cPM 15M / 15MA / 15MC | | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | | Cleared in K200035 | | | | | | | Subject Device | | | | | | | Base and rear cover action | Dock blue | | | | | | cPM 10 Guardian plus: Dock blue cPM 10A/10C: Medium blue-grey | cPM 12: Dock blue cPM 12A/12C: Medium blue-grey | cPM 15: Dock blue cPM 15A/15C: Medium blue-grey | cPM 10M: Dock blue cPM 10MA / 10MC: Medium blue-grey | cPM 12M: Dock blue cPM 12MA/12MC: Medium blue-grey | cPM 15M: Dock blue cPM 15MA/15MC: Medium blue-grey | | Work Mode | Support standby mode, privacy mode, night mode and intubation mode. | | | Support CPB mode, standby mode, privacy mode, night mode and intubation mode. | | | cPM 10/10A: Guardian plus support standby mode, privacy mode, night mode and intubation mode.cPM 10C supports standby mode, night mode and intubation mode, and optional privacy mode. | cPM 12/12A support standby mode, privacy mode, night mode and intubation mode.cPM 12C supports standby mode, night mode and intubation mode, and optional privacy mode. | cPM 15/15A support standby mode, privacy mode, night mode and intubation mode.cPM 15C supports standby mode, night mode and intubation mode, and optional privacy mode. | cPM 10M/10MA support CPB mode, standby mode, privacy mode, night mode and intubation mode.cPM 10MC supports CPB mode, standby mode, night mode and intubation mode, and optional privacy mode. | cPM 12M/12MA support CPB mode, standby mode, privacy mode, night mode and intubation mode.cPM 12MC supports CPB mode, standby mode, night mode and intubation mode, and optional privacy mode. | cPM 15M/15MA support CPB mode, standby mode, privacy mode, night mode and intubation mode.cPM 15MC supports CPB mode, standby mode, night mode and intubation mode, and optional privacy mode. | | Primary Display | 10.1" | 12.1" | 15.6" | 10.1" | 12.1" | 15.6" | 10.1" | 12.1" | 15.6" | 10.1" | 12.1" | 15.6" | | Display and touch screen resolution | 1280*800 pixels | 1280*800 pixels | 1360*700 pixels | 1280*800 pixels | 1280*800 pixels | 1360*700 pixels | 1280*800 pixels | 1280*800 pixels | 1360*700 pixels | 1280*800 pixels | 1280*800 pixels | 1360*700 pixels | | Secondary display | Mirrored displayVGA display output | | | | | | Mirrored displayTMDS display output | | | | | | | Wristless module | Supports Land Wireless Module:2.4G/5G module for connecting to a network wirelessly to construct a monitoring network with a central monitoring system (CMS). | | | | | | Supports Silas Wireless Module:2.4G/5G module for connecting to a network wirelessly to construct a monitoring network with a central monitoring system (CMS). | | | | | | | Internal Module rack | Not supported | Not supported | Not supported | Supported page pin-based and infrared-based communication | Supported page pin-based and infrared-based communication | Supported page pin-based and infrared-based communication | Not supported | Not supported | Not supported | Supported page pin-based communication | Supported page pin-based communication | Supported page pin-based communication | | Satellite Module Rack | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported | Supported | Supported | Supported | | Main-Control Hardware Platform | AM315x, BBR3 (standard configuration: 512 MB, full configuration: 1 GB) | | | | | | AM62X, 1GB DDR4 | | | | | | | Power supply | One rechargeable Lithium ion battery or 40W AC power supply | One or two rechargeable Lithium ion batteries or 40W AC power supply | One rechargeable Lithium ion battery or 40W AC power supply | One or two rechargeable Lithium ion batteries or 40W AC power supply | One or two rechargeable Lithium ion batteries or 40W AC power supply | One rechargeable Lithium ion battery or 40W AC power supply | One or two rechargeable Lithium ion batteries or 40W AC power supply | One rechargeable Lithium ion battery or 40W AC power supply | One rechargeable Lithium ion battery or 40W AC power supply | One or two rechargeable Lithium ion batteries or 40W AC power supply | One or two rechargeable Lithium ion batteries or 40W AC power supply | One or two rechargeable Lithium ion batteries or 40W AC power supply | | External battery box | Not supported | Supported | Not supported | Not supported | Supported | Not supported | Not supported | Supported | Not supported | Not supported | Supported | Not supported | | Battery | Chargeable Lithium-Ion, 10.8VDC, 5600 mAh. Chargeable Lithium-Ion, 10.95 VDC, 4500 mAh. Chargeable Lithium-Ion, 10.95 VDC, 2600 mAh. | | | | | | Chargeable Lithium-Ion, 10.8VDC, 5600 mAh. Chargeable Lithium-Ion, 10.95 VDC, 5200 mAh. Chargeable Lithium-Ion, 10.95 VDC, 2600 mAh. | | | | | | | Data storage | Embedded Multi Media Card (eMMC): Two 4GB eMMC or one 5GB eMMC. | | | | | | Embedded Multi Media Card (eMMC): One 8 GB eMMC. | | | | | | | Data Recorder | Supports a built-in thermal recorder. | | | | | | Supports a built-in thermal recorder. | | | | | | | Device Integration | Use the RS-232 interface to integrate 3rd party devices. Allow parameter values, waveforms and alarms from 3rd party devices to be displayed, stored and printed. | | | | | | Use the RS-232 interface to integrate 3rd party devices. Allow parameter values, waveforms and alarms from 3rd party devices to be displayed, stored and printed. | | | | | | | Speaker | Provides audible alarm tones (45 to 85 dB), key tones, QRS tones, support PITCH TONE and multilevel tone modulation. | | | | | | Provides audible alarm tones (45 to 85 dB), key tones, QRS tones, support PITCH TONE and multilevel tone modulation. | | | | | | | Alarm System | Supports alarm volume escalation. The alarm lamp will light eyes, yellow, or red depending on the alarm type. Supports ISO, mode 1, and mode 2 auditory alarm signals. | | | | | | Supports alarm volume escalation. The alarm lamp will light eyes, yellow, or red depending on the alarm type. Supports ISO, mode 1, mode 2 and ISO auditory alarm signals. | | | | | | | ECG | Use the multi-parameter module integrated on the main control board to measure the ECG signal and support 3-lead, 5-lead, 6-lead or 12-lead selectable, arrhythmia detection, ST segment analysis, QT analysis, an interpretation of resting 12-lead ECG, 3-point Auto detection, Dual Channel Pace detection, adjustable QRS threshold, Multi-lead ECG synchronization analysis and heart rate (HR). Supports intelligent arrhythmia alarm. HR Measurement range: 15–350bpm (neonate, pediatric), 15–300bpm (adult). Accuracy: +1 bpm or +1%, whichever is greater. ST Measurement range: -2.8mV~+2.8mV; Accuracy: -0.8mV~+0.8mV; Accuracy: +0.02mV or +10%, whichever is greater, other range: not specified. QT Measurement range: 200–800m; Accuracy: +30ms. Supports two-channel ECG analysis algorithm. | | | | | | Use the multi-parameter module integrated on the main control board to measure the ECG signal and support 3-lead, 5-lead, 6-lead or 12-lead selectable, arrhythmia detection, ST segment analysis, QT analysis, an interpretation of resting 12-lead ECG, 3-point Auto detection, Dual Channel Pace detection, adjustable QRS threshold, Multi-lead ECG synchronization analysis and heart rate (HR). Supports intelligent arrhythmia alarm. HR Measurement range: 15–350bpm (neonate, pediatric), 15–300bpm (adult). Accuracy: +1 bpm or +1%, whichever is greater. ST Measurement range: -2.8mV~+2.8mV; Accuracy: -0.8mV~+0.8mV; Accuracy: +0.02mV or +10%, whichever is greater, other range: not specified. QT Measurement range: 200–800m; Accuracy: +30ms. Supports two-channel ECG analysis algorithm. | | | | | | Page 5 of 8 {9} 510(k) Summary Shenzhen Mindray Bio-Medical Electronics K260098 | Feature | ePM 10 | ePM 12 | ePM 15 | ePM 10M | ePM 12M | ePM 15M | ePM 10 / 10A / 10C / Guardian plus | ePM 12 / 12A / 12C | ePM 15 / 15A / 15C | ePM 10M / 10MA / 10MC | ePM 12M / 12MA / 12MC | ePM 15M / 15MA / 15MC | | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | | Cleaved to K200015 | | | | | | | | | | | | | | Respiration rate (Reap) | Uses the multi-parameter module integrated on the main control board to measure the respiration waveforms and respiratory rate through trans-thoracic impedance method.Masseterment range: Adult: 0 to 120 rpm, Pediatric, neonate: 0 to 150 rpm. Accuracy: 7 to 150 rpm, <2 rpm or <2%, whichever is greater/0 to 6 rpm. Not specified. | | | | | | Uses the multi-parameter module integrated on the main control board to measure the respiration waveforms and respiratory rate through trans-thoracic impedance method.Masseterment range: Adult: 0 to 120 rpm, Pediatric, neonate: 0 to 150 rpm. Accuracy: 7 to 150 rpm, <2 rpm or <2%, whichever is greater/0 to 6 rpm. Not specified. | | | | | | | Temperature (Temp) | Uses the multi-parameter module integrated on the main control board to measure temperature using the thermal resistance method.Masseterment range: 0 to 50°C (12 to 122°F). Accuracy: <0.1°C or <0.2°F (without probe). | | | | | | Uses the multi-parameter module integrated on the main control board to measure temperature using the thermal resistance method.Masseterment range: 0 to 50°C (12 to 122°F). Accuracy: <0.1°C or <0.2°F (without probe). | | | | | | | Pulse oxygen saturation (SpO2) | Uses the built-in multi-parameter module integrated on the main control board or built-in third part SpO2 Module installed on the main control board to measure Pulse oxygen saturation. ePM series patient monitors are compatible with the following 3 types of modules to measure oxygen saturation.Bull-in Mindray SpO2 module is integrated on the main control board.Masseterment range: 0-100%.Accuracy: 70%-100%; <2%ABS (Adult/Pediatric), 70%-100%; <3%ABS (Neonate), 0-69%; not specified.Bull-in Maxima SpO2 module is installed on the main control board.Masseterment range: 1-100%.Accuracy:wilhoot motion 70%-100%; <2%ABS (Adult/Pediatric), 70%-100%; <3%ABS (Neonate), 1-69%; not specified.With motion 70%-100%; <3%ABS, 1-69%; not specified.Nellcor SpO2 module is installed on the main control board.Masseterment range: 0-100%.Accuracy: 70%-100%; <2%ABS (Adult/Pediatric), 70%-100%; <3%ABS (Neonate), 0-69%; not specified. | | | | | | The external SpO2 module can be used as ePM 10M/10MA/10MC/12M/12MA/12MC/15M/15MA/15MC.The built-in SpO2 module can be used as ePM 10/10A/10C/Guardian plus 12/12A/12C/15/15A/15C/10M/10MA/10MC/12M/12MA/12MC/15M/15MA/15MC.Uses the built-in multi-parameter module integrated on the main control board . built-in third part SpO2 Module installed on the main control board or external SpO2 module to measure Pulse oxygen saturation . ePM series patient monitors are compatible with the following 3 types of modules to measure oxygen saturation.Bull-in Mindray SpO2 module is integrated on the main control board.Masseterment range: 0-100%.Accuracy: 70%-100%; <2%ABS (Adult/Pediatric), 70%-100%; <3%ABS (Neonate), 0-69%; not specified.Bull-in Maxima SpO2 module (MSX2040) is installed on the main control board.Masseterment range: 1-100%.Accuracy:wilhoot motion 70%-100%; <2%ABS (Adult/Pediatric), 70%-100%; <3%ABS (Neonate), 1-69%; not specified.With motion 70%-100%; <3%ABS, 1-69%; not specified.Nellcor SpO2 module is installed on the main control board.Masseterment range: 0-100%.Accuracy: 70%-100%; <2%ABS (Adult/Pediatric), 70%-100%; <3%ABS (Neonate), 0-69%; not specified. | | | | | | | Pulse rate (PR) | Pulse rate may be obtained from the SpO2 measurement or the IBP measurement.Masseterment range:20-250rpm (Mindray SpO2), 25-240rpm (Maxima SpO2), 20-300rpm (Nellcor SpO2), 25-350rpm (IBP).Accuracy:<3 bpm (Mindray SpO2), <3 bpm without motion, <5 bpm with motion (Maxima), 20-250rpm, <3 bpm, 251-300rpm, not specified (Nellcor SpO2), <1 bpm or <1%, whichever is greater (IBP). | | | | | | Pulse rate may be obtained from the SpO2 measurement or the IBP measurement.Masseterment range:20-250rpm (Mindray SpO2), 25-240rpm (Maxima SpO2) (MSX2040), 20-300rpm (Nellcor SpO2), 25-350rpm (IBP).Accuracy:<3 bpm (Mindray SpO2), <3 bpm without motion, <5 bpm with motion (Maxima), 20-250rpm, <3 bpm, 251-300rpm, not specified (Nellcor SpO2), <1 bpm or <1%, whichever is greater (IBP). | | | | | | | Non-invasive blood pressure (NIBP) | Uses the multi-parameter module integrated on the main control board to measure NIBP. It uses the oscillometric method for measuring non-invasive blood pressure (NIBP).Measurement range:Synistic, 25-290mmHg (Adult), 25-240mmHg (Pediatric), 25-140mmHg (Neonate).Diastolic: 10-250mmHg (Adult), 10-200mmHg (Pediatric), 10-115mmHg (Neonate).Mean: 15-260mmHg (Adult), 15-215mmHg (Pediatric), 15-125mmHg (Neonate). PR: 30-300rpm.Accuracy:NIBP: Max mean error: <5mmHg; Max standard deviation: 5mmHg. PR: <3 bpm or <3%, whichever is greater. | | | | | | Uses the multi-parameter module integrated on the main control board to measure NIBP. It uses the oscillometric method (deflation/masseerment method and deflation measurement method) for measuring non-invasive blood pressure (NIBP).Measurement range:Synistic, 25-290mmHg (Adult), 25-240mmHg (Pediatric), 25-140mmHg (Neonate).Diastolic: 10-250mmHg (Adult), 10-200mmHg (Pediatric), 10-115mmHg (Neonate).Mean: 15-260mmHg (Adult), 15-215mmHg (Pediatric), 15-125mmHg (Neonate). PR: 30-300rpm.Accuracy:NIBP: Max mean error: <5mmHg; Max standard deviation: 5mmHg. PR: <3 bpm or <3%, whichever is greater.Derived value of Pediatric Initial Pressure for NIBP Module: 120 mmHg.The NIBP measurement interval can be set. The options include manual, sequence, 24h, 12h, 8h, -4h, 3h, 2h, 1.5h, 1h, 10min, 20min, 15min, 10min, 5min, 2min, 2.5min, 2 min, 1min | | | | | | | Invasive blood pressure (IBP) | Uses the multi-parameter module integrated on the main control board or the external IBP Module (only used in ePM 10M/12M/15M) to measure invasive blood pressure. The monitor can monitor up to 6 invasive blood pressures and displays systolic, diastolic and mean pressures and a waveform for each pressure. Support Pulse Pressure Variation (PPV) and Pulmonary Artery Wedge Pressure (PAWP)/function.Masseterment range: -50-300mmHg.Accuracy of module: <2% or <1mmHg, whichever is greater.This measurement can be used for adults, pediatrics and neonates except that PAWP is not for neonates. | | | | | | Uses the multi-parameter module integrated on the main control board or the external IBP Module (only used in ePM 10M/12M/15M) to measure invasive blood pressure. The monitor can monitor up to 6 invasive blood pressures and displays systolic, diastolic and mean pressures and a waveform for each pressure. Support Pulse Pressure Variation (PPV) and Pulmonary Artery Wedge Pressure (PAWP)/function, Systolic Pressure Variation (SPV), 3rd abdominal pressure (3AP) and abdominal perfusion pressure(APP).Measurement range: -50-300mmHg.Accuracy of module: <2% or <1mmHg, whichever is greater.This measurement can be used for adults, pediatrics and neonates except that PAWP is not for neonates. | | | | | | | Cardiac output (C.O.) | The built-in cardiac output (C.O.) module or external cardiac output (C.O.) (only can be used in ePM 10M/12M/15M) module measures cardiac output and other hemodynamic parameters using the right heart (ratio) thermodilution method. The temperature change is displayed as a curve in the C.O. split screen, and the monitor calculates the C.O. value from this curve. The monitor can store up to 6 measurements.Masseterment range:C.O.: 0.1-20 L/min.TR: 23-43°C, TE: 0-27°C.Accuracy:C.O.: <5% or <0.1L/min, whichever is greater.TR:TE: <0.1°C (without sensor).This measurement can be used for adults. | | | | | | The built-in cardiac output (C.O.) module or external cardiac output (C.O.) (only can be used in ePM 10M/10MA/10MC/12M/12MA/12MC/15M/15MA/15MC) module measures cardiac output and other hemodynamic parameters using the right heart (ratio) thermodilution method. The temperature change is displayed as a curve in the C.O. split screen, and the monitor calculates the C.O. value from this curve. The monitor can store up to 6 measurements.Masseterment range:C.O.: 0.1-20 L/min.TR: 23-43°C, TE: 0-27°C.Accuracy:C.O.: <5% or <0.1L/min, whichever is greater.TR:TE: <0.1°C (without sensor).This measurement can be used for adults and pediatrics. | | | | | | Page 4 of 8 {10} 510(k) Summary Shenzhen Mindray Bio-Medical Electronics K260098 # 9. SUMMARY OF NON-CLINICAL PERFORMANCE TESTING # Biocompatibility Testing Not applicable. The ePM Patient Monitor Series is not patient contacting. # Electrical Safety The following electrical safety testing was conducted: - IEC 60601-1:2005+AMD1:2012+AMD2:2020, Medical electrical equipment - Part 1: General requirements for basic safety and essential performance - ANSI C63.27-2021, American National Standard for Evaluation of Wireless Coexistence - AAMI TIR69:2017 (R2020), Risk management of radio-frequency wireless coexistence for medical devices and systems # Electromagnetic Compatibility (EMC) The following electromagnetic compatibility testing was conducted: - IEC 60601-1-2 Ed. 4.1 en:2020, Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests - IEC/TR 60601-4-2 Edition 1.0 2016-05 Medical electrical equipment - Part 4-2: Guidance and interpretation - Electromagnetic immunity: performance of medical electrical equipment and medical electrical systems # Software Software verification and validation testing was conducted and documentation was provided as recommended by FDA's Guidance for Industry and FDA Staff, "Guidance for the Content of Premarket Submissions for Software Contained in Medical Devices." Verification of the ePM Series Patient Monitors was conducted to ensure that the product works as designed. Validation was conducted to check the design and performance of the product. # Performance Testing The following performance testing was completed: - IEC 60601-1-8 Edition 2.2 2020-07 CONSOLIDATED VERSION Medical electrical equipment – Part 1-8: General requirements for basic safety and essential performance – Collateral standard: General requirements, tests and guidance for alarm systems in medical electrical equipment and medical electrical systems. - IEC 60601-2-25 Edition 2.0 2011-10Medical electrical equipment - Part 2: Particular requirements for the basic safety and essential performance of electrocardiographs Page 7 of 8 {11} 510(k) Summary Shenzhen Mindray Bio-Medical Electronics K260098 - • IEC 60601-2-27 Edition 3.0 2011-03 Medical electrical equipment - Part 2: Particular Requirements for the Safety, Including Essential Performance of Electrocardiographic Monitoring Equipment - • IEC 80601-2-30: Edition 2.0 2018-03 Medical electrical equipment - Part 2: Particular requirements for the basic safety and essential performance of automated non-invasive sphygmomanometers - • IEC 60601-2-34 Edition 3.0 2011-05 Medical electrical equipment – Part 2-34: Particular requirements for the basic safety and essential performance of invasive blood pressure monitoring equipment - • EN IEC 80601-2-49:2019 Medical electrical equipment Part 2-49: Particular requirements for the basic safety and essential performance of multifunction patient monitors - • ISO 80601-2-55 Second edition 2018-02 [Including AMD1:2023] Medical electrical equipment - Part 2: Particular requirements for the basic safety and essential performance of respiratory gas monitors [Including Amendment 1 (2023)] - • ISO 80601-2-56 Second edition 2017-03 [Including AMD1:2018] Medical electrical equipment — Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement [Including: Amendment 1 (2018)] - • ISO 80601-2-61 Second edition 2017-12 (Corrected version 2018-02) Medical electrical equipment – Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment - • IEC 60601-2-10 Edition 2.2 2023-01 CONSOLIDATED VERSION Medical electrical equipment - Part 2: Particular requirements for the basic safety and essential performance of nerve and muscle stimulators - • IEC 80601-2-26:2019 Medical electrical equipment - Part 2-26: Particular requirements for the basic safety and essential performance of electroencephalographs ## 10. CONCLUSION The results of the performance testing described above demonstrate that the subject device ePM Series Patient Monitor Series is substantially equivalent to the predicate device. Page 8 of 8
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...