SnugFit ASA Extension

K251933 · Medacta International S.A. · MBI · Jul 1, 2025 · Orthopedic

Device Facts

Record IDK251933
Device NameSnugFit ASA Extension
ApplicantMedacta International S.A.
Product CodeMBI · Orthopedic
Decision DateJul 1, 2025
DecisionSESE
Submission TypeSpecial
Regulation21 CFR 888.3040
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The SnugFit All-Suture Anchor is intended for use in arthroscopic or open surgical approaches for fixation of soft tissue to bone in the hip and shoulder in the following procedures: • Hip: acetabular labral repair • Shoulder: glenoid labrum repair; rotator cuff repair, biceps tendon repair

Device Story

SnugFit ASA Extension consists of implantable all-suture anchors used for soft tissue-to-bone fixation in hip and shoulder surgeries. Device comprises UHMWPE and polyester sutures pre-loaded on a disposable stainless-steel driver with plastic handle. During surgery, surgeon deploys anchor into bone; braided suture structure expands to create fixation point; remaining suture secures soft tissue to bone. Used in OR by orthopedic surgeons. Provides mechanical fixation for labral and rotator cuff repairs. Benefits include stable soft tissue attachment to bone, facilitating healing. No software or electronic components.

Clinical Evidence

No clinical studies were conducted. Substantial equivalence is supported by non-clinical performance testing, including pull-out force assessment, biocompatibility, shelf-life evaluation, and pyrogenicity testing (LAL and USP <151>).

Technological Characteristics

Materials: UHMWPE and polyester sutures, stainless-steel driver shaft, plastic handle. Fixation: Mechanical expansion of braided suture anchor. Sterilization: Sterile. Connectivity: None. Software: None.

Indications for Use

Indicated for patients requiring soft tissue to bone fixation in the hip (acetabular labral repair) or shoulder (glenoid labrum repair, rotator cuff repair, biceps tendon repair) via arthroscopic or open surgical approaches.

Regulatory Classification

Identification

A smooth or threaded metallic bone fixation fastener is a device intended to be implanted that consists of a stiff wire segment or rod made of alloys, such as cobalt-chromium-molybdenum and stainless steel, and that may be smooth on the outside, fully or partially threaded, straight or U-shaped; and may be either blunt pointed, sharp pointed, or have a formed, slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a guide pin for insertion of other implants, or it may be implanted through the skin so that a pulling force (traction) may be applied to the skeletal system.

Predicate Devices

Submission Summary (Full Text)

{0} FDA U.S. FOOD &amp; DRUG ADMINISTRATION July 1, 2025 Medacta International S.A. % Christopher Lussier Senior Director, Quality and Regulatory Medacta USA 6386 Global Drive Suite 101 Memphis, Tennessee 38141 Re: K251933 Trade/Device Name: SnugFit ASA Extension Regulation Number: 21 CFR 888.3040 Regulation Name: Smooth Or Threaded Metallic Bone Fixation Fastener Regulatory Class: Class II Product Code: MBI Dated: June 24, 2025 Received: June 24, 2025 Dear Mr. Lussier: We have reviewed your section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (the Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database available at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. U.S. Food &amp; Drug Administration 10903 New Hampshire Avenue Silver Spring, MD 20993 www.fda.gov {1} K251933 - Christopher Lussier Page 2 Additional information about changes that may require a new premarket notification are provided in the FDA guidance documents entitled "Deciding When to Submit a 510(k) for a Change to an Existing Device" (https://www.fda.gov/media/99812/download) and "Deciding When to Submit a 510(k) for a Software Change to an Existing Device" (https://www.fda.gov/media/99785/download). Your device is also subject to, among other requirements, the Quality System (QS) regulation (21 CFR Part 820), which includes, but is not limited to, 21 CFR 820.30, Design controls; 21 CFR 820.90, Nonconforming product; and 21 CFR 820.100, Corrective and preventive action. Please note that regardless of whether a change requires premarket review, the QS regulation requires device manufacturers to review and approve changes to device design and production (21 CFR 820.30 and 21 CFR 820.70) and document changes and approvals in the device master record (21 CFR 820.181). Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR Part 803) for devices or postmarketing safety reporting (21 CFR Part 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reporting-combination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR Part 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR Parts 1000-1050. All medical devices, including Class I and unclassified devices and combination product device constituent parts are required to be in compliance with the final Unique Device Identification System rule ("UDI Rule"). The UDI Rule requires, among other things, that a device bear a unique device identifier (UDI) on its label and package (21 CFR 801.20(a)) unless an exception or alternative applies (21 CFR 801.20(b)) and that the dates on the device label be formatted in accordance with 21 CFR 801.18. The UDI Rule (21 CFR 830.300(a) and 830.320(b)) also requires that certain information be submitted to the Global Unique Device Identification Database (GUDID) (21 CFR Part 830 Subpart E). For additional information on these requirements, please see the UDI System webpage at https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/unique-device-identification-system-udi-system. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-devices/medical-device-safety/medical-device-reporting-mdr-how-report-medical-device-problems. For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory- {2} K251933 - Christopher Lussier Page 3 assistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100). Sincerely, CHRISTOPHER FERREIRA -S Christopher Ferreira, M.S. Assistant Director DHT6C: Division of Restorative, Repair, and Trauma Devices OHT6: Office of Orthopedic Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health Enclosure {3} SnugFit ASA Extension Page 9 of 34 | Indications for Use | | | | --- | --- | --- | | Please type in the marketing application/submission number, if it is known. This textbox will be left blank for original applications/submissions. | K251933 | ? | | Please provide the device trade name(s). | | ? | | SnugFit ASA Extension | | | | Please provide your Indications for Use below. | | ? | | The SnugFit All-Suture Anchor is intended for use in arthroscopic or open surgical approaches for fixation of soft tissue to bone in the hip and shoulder in the following procedures: • Hip: acetabular labral repair • Shoulder: glenoid labrum repair; rotator cuff repair, biceps tendon repair | | | | Please select the types of uses (select one or both, as applicable). | ☑ Prescription Use (Part 21 CFR 801 Subpart D) ☐ Over-The-Counter Use (21 CFR 801 Subpart C) | ? | {4} SnugFit ASA Extension Special 510(k) Medacta International SA # 510(k) Summary K251933 # I. Submitter Medacta International SA Strada Regina 6874 Castel San Pietro (CH) Switzerland Phone (+41) 91 696 60 60 Fax $(+41)$ 916966066 Contact Person: Stefano Baj, Regulatory and Compliance Director, Medacta International SA Applicant Correspondent: Chris Lussier, Senior Director, Quality and Regulatory, Medacta USA Date Prepared: June 24, 2025 # II. Device | Device Proprietary Name: | SnugFit ASA Extension | | --- | --- | | Common or Usual Name: | Soft Tissue Fixation Device | | Classification Name: | Fastener, Fixation, Non-degradable, Soft Tissue | | Primary Product Code | MBI | | Regulation Number: | 21 CFR 888.3040 | | Device Classification | II | # III. Predicate Device Substantial equivalence is claimed to the following predicate devices. Primary Predicate device: - SnugFit All-Suture Anchor extension, K230544, Medacta International SA Additional Predicate devices: - SnugFit All-Suture Anchor, K203485, Medacta International SA. # IV. Device Description The SnugFit ASA Extension is a Medacta suture anchors portfolio extension including implantable devices indicated for the treatment of hip and shoulder instability as well as shoulder rotator cuff repair and biceps tenodesis. Specifically, the purpose of this submission is to gain the clearance for: - SnugFit All-Suture Anchor - Size 1: 1 single loaded configuration (short and long), 3 double loaded configurations (short and long and two different color options each); and - SnugFit All-Suture Anchor - Size 2: 3 triple loaded configurations (short) and 1 double loaded configuration (short). {5} SnugFit ASA Extension Special 510(k) Medacta International SA The subject devices are entirely composed of sutures, made up of ultra-high molecular weight polyethylene (UHMWPE) and polyester (PET), which are specifically arranged and braided to create an anchoring point within the bone, after their deployment. The sutures themselves, are also used to secure soft tissues to a supporting structure, i.e. bone. The sterile, individually packaged, subject devices are composed of two parts: an all-suture anchor and a driver made of a stainless-steel shaft with an over-molded plastic handle. The all-suture anchor is provided pre-loaded on the specifically designed disposable driver. ## V. Indications for Use The SnugFit All-Suture Anchor is intended for use in arthroscopic or open surgical approaches for fixation of soft tissue to bone in the hip and shoulder in the following procedures: - Hip: acetabular labral repair - Shoulder: glenoid labrum repair; rotator cuff repair, biceps tendon repair ## VI. Comparison of Technological Characteristics The subject and the predicate devices (K230544, K203485) are substantially equivalent with respect to the following characteristics: - Indications for Use; - Sizes; - Deployment and fixation mechanism; - Driver design; - Materials; - Biocompatibility; - Device usage; - Packaging; - Shelf-life; and - Sterilization. The only difference between the subject and the predicate devices (K230544, K203485) is the type and number of preloaded sutures. ## Discussion The subject pre-loaded sutures have been designed to expand the portfolio providing surgeons with a broader selection of devices, but this difference has not any impact on safety and effectiveness since the subject devices functional mechanism is identical to the one of the predicate devices and no worst case is introduced with respect to pull-out force. The comparison of technological characteristics and performance data provided within the submission supports the substantial equivalence of the subject devices respect to the predicate devices. ## VII. Performance Data Based on the risk analysis, testing activities were conducted to written protocols. The following evaluations and rationales are provided in support of the substantial equivalence determination. {6} SnugFit ASA Extension Special 510(k) Medacta International SA # Non-Clinical Studies - PERFORMANCE TESTING - Substantial equivalence assessment - PYROGENICITY - Bacterial endotoxin test (LAL test) according to European Pharmacopoeia §2.6.14 (which is equivalent to USP chapter &lt;85&gt;) - Pyrogen test according to USP chapter &lt;151&gt; for pyrogenicity determination - The subject devices are not labeled as non-pyrogenic or pyrogen free. - BIOCOMPATIBILITY assessment - SHELF-LIFE evaluation # Clinical Studies: - No clinical studies were conducted. # VIII. Conclusion The information provided above supports that the subject devices are substantially equivalent to the predicate devices.
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...