Copioumed AAMI 3 Surgical Gown

K251860 · Copioumed International, Inc. · FYA · Feb 26, 2026 · General, Plastic Surgery

Device Facts

Record IDK251860
Device NameCopioumed AAMI 3 Surgical Gown
ApplicantCopioumed International, Inc.
Product CodeFYA · General, Plastic Surgery
Decision DateFeb 26, 2026
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 878.4040
Device ClassClass 2

Indications for Use

Copioumed AAMI 3 Surgical Gown is intended to be worn by operating room personnel during surgical procedures to protect both surgical patient and the operating room personnel from the transfer of microorganisms, body fluids, and particulate materials. The gown is single-use, disposable, and provided sterile, and is classified as AAMI Level 3.

Device Story

Surgical gown; single-use; disposable; sterile. Constructed from SMS (polypropylene laminated with polyethylene). Provides AAMI Level 3 barrier protection. Used by operating room personnel during surgical procedures. Protects patient and personnel from microorganisms, body fluids, and particulates. Features adjustable neck with Velcro closure; knit cuffs. Available in standard and high-performance models. Bench testing confirms liquid barrier performance, tensile strength, tear resistance, and biocompatibility.

Clinical Evidence

Bench testing only. Performance validated via AATCC 42 (water resistance), AATCC 127 (hydrostatic pressure), ANSI/AAMI PB70:2012 (liquid barrier), NWSP 080.8.R0 (alcohol repellency), ASTM D3776 (weight), ASTM D5034 (tensile), ASTM D5587 (tear), 16 CFR 1610 (flammability), ISO 9073-10 (linting), and ASTM D1683 (seam strength). Biocompatibility confirmed per ISO 10993-5 (cytotoxicity), ISO 10993-23 (irritation), and ISO 10993-10 (sensitization). Sterility validated per ISO 11737-1 and EO residuals per ISO 10993-7.

Technological Characteristics

Materials: Polypropylene laminated with polyethylene (SMS nonwoven). Barrier: AAMI Level 3 per ANSI/AAMI PB70:2012. Sterilization: Ethylene Oxide (EO). Physical: Knit cuffs, Velcro neck closure. Standards: ASTM D3776, ASTM D5034, ASTM D5587, AATCC 42, AATCC 127, ISO 10993 series.

Indications for Use

Indicated for operating room personnel during surgical procedures to protect patient and personnel from transfer of microorganisms, body fluids, and particulate materials.

Regulatory Classification

Identification

Surgical apparel are devices that are intended to be worn by operating room personnel during surgical procedures to protect both the surgical patient and the operating room personnel from transfer of microorganisms, body fluids, and particulate material. Examples include surgical caps, hoods, masks, gowns, operating room shoes and shoe covers, and isolation masks and gowns. Surgical suits and dresses, commonly known as scrub suits, are excluded.

Special Controls

*Classification.* (1) Class II (special controls) for surgical gowns and surgical masks. A surgical N95 respirator or N95 filtering facepiece respirator is not exempt if it is intended to prevent specific diseases or infections, or it is labeled or otherwise represented as filtering surgical smoke or plumes, filtering specific amounts of viruses or bacteria, reducing the amount of and/or killing viruses, bacteria, or fungi, or affecting allergenicity, or it contains coating technologies unrelated to filtration (e.g., to reduce and or kill microorganisms). Surgical N95 respirators and N95 filtering facepiece respirators are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 878.9, and the following conditions for exemption:(i) The user contacting components of the device must be demonstrated to be biocompatible. (ii) Analysis and nonclinical testing must: (A) Characterize flammability and be demonstrated to be appropriate for the intended environment of use; and (B) Demonstrate the ability of the device to resist penetration by fluids, such as blood and body fluids, at a velocity consistent with the intended use of the device. (iii) NIOSH approved under its regulation. (2) Class I (general controls) for surgical apparel other than surgical gowns and surgical masks. The class I device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 878.9.

Predicate Devices

Submission Summary (Full Text)

{0} FDA U.S. FOOD &amp; DRUG ADMINISTRATION February 26, 2026 Copioumed International, Inc. % Ming-Yie Jan Principal Consultant Ruscert Technology Co., Ltd. 8f., # 187, Lequn 2nd Rd., Zhongshan Dist. Taipei City, 10462 Taiwan Re: K251860 Trade/Device Name: Copioumed AAMI 3 Surgical Gown Regulation Number: 21 CFR 878.4040 Regulation Name: Surgical Apparel Regulatory Class: Class II Product Code: FYA Dated: January 26, 2026 Received: January 26, 2026 Dear Ming-Yie Jan: We have reviewed your section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (the Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database available at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Additional information about changes that may require a new premarket notification are provided in the FDA guidance documents entitled "Deciding When to Submit a 510(k) for a Change to an Existing Device" U.S. Food &amp; Drug Administration 10903 New Hampshire Avenue Silver Spring, MD 20993 www.fda.gov {1} K251860 - Ming-Yie Jan Page 2 (https://www.fda.gov/media/99812/download) and "Deciding When to Submit a 510(k) for a Software Change to an Existing Device" (https://www.fda.gov/media/99785/download). Your device is also subject to, among other requirements, the Quality Management System Regulation (QMSR) (21 CFR Part 820), which includes, but is not limited to, ISO 13485 clause 7.3 (Design controls), ISO 13484 clause 8.3 (Nonconforming product), and ISO 13485 clause 8.5 (Corrective and preventative action). Please note that regardless of whether a change requires premarket review, the QMSR requires device manufacturers to review and approve changes to device design and production (ISO 13485 clause 7.3 and 21 CFR 820.70) and document changes and approvals in the Medical Device File (21 CFR 820.181). Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR Part 803) for devices or postmarketing safety reporting (21 CFR Part 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reporting-combination-products); good manufacturing practice requirements as set forth in the Quality Management System Regulation (QMSR) (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR Part 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR Parts 1000-1050. All medical devices, including Class I and unclassified devices and combination product device constituent parts are required to be in compliance with the final Unique Device Identification System rule ("UDI Rule"). The UDI Rule requires, among other things, that a device bear a unique device identifier (UDI) on its label and package (21 CFR 801.20(a)) unless an exception or alternative applies (21 CFR 801.20(b)) and that the dates on the device label be formatted in accordance with 21 CFR 801.18. The UDI Rule (21 CFR 830.300(a) and 830.320(b)) also requires that certain information be submitted to the Global Unique Device Identification Database (GUDID) (21 CFR Part 830 Subpart E). For additional information on these requirements, please see the UDI System webpage at https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/unique-device-identification-system-udi-system. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-devices/medical-device-safety/medical-device-reporting-mdr-how-report-medical-device-problems. For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100). {2} K251860 - Ming-Yie Jan Page 3 Sincerely, ALLAN GUAN -S For Bifeng Qian, M.D., Ph.D. Assistant Director DHT4C: Division of Infection Control Devices OHT4: Office of Surgical and Infection Control Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health Enclosure {3} FORM FDA 3881 (8/23) Page 1 of 1 PSC Publishing Services (301) 443-6740 EF | DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration Indications for Use | Form Approved: OMB No. 0910-0120 Expiration Date: 07/31/2026 See PRA Statement below. | | --- | --- | | 510(k) Number (if known) K251860 | | | Device Name Copioumed AAMI 3 Surgical Gown | | | Indications for Use (Describe) Copioumed AAMI 3 Surgical Gown is intended to be worn by operating room personnel during surgical procedures to protect both surgical patient and the operating room personnel from the transfer of microorganisms, body fluids, and particulate materials. The gown is single-use, disposable, and provided sterile, and is classified as AAMI Level 3. | | | Type of Use (Select one or both, as applicable) ☐ Prescription Use (Part 21 CFR 801 Subpart D) ☑ Over-The-Counter Use (21 CFR 801 Subpart C) | | | CONTINUE ON A SEPARATE PAGE IF NEEDED. | | | This section applies only to requirements of the Paperwork Reduction Act of 1995. *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.* | | | The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov | | | "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number." | | {4} 新萬盟有限公司 COPIOUMED INTERNATIONAL INC. 台北市復興北路 1號 16樓之 4 16F-4, NO.1, FUXING N.RD., SONGSHAN DIST., TAIPEI CITY 105, TAIWAN (R.O.C.) TEL:886-2-2772-1815 FAX:886-2-2711-9232 # 510(k) SUMMARY This 510 (K) summary is being submitted in accordance with requirements of Title 21,CFR Section 807.92. A. 510(k) NUMBER K251860 B. DATE PREPARED February 17th, 2026 C. SUBMITTER COPIOUMED INTERNATIONAL INC. 16F-4, No.1, Fuxing N. Rd., Songshan Dist., Taipei City 105, Taiwan (R.O.C.) FEI Number: 9681151 Tel: +886 22772 1815 D. CONTACT PERSON Primary Contact Title: Chairman of the Board Name: James Liu Tel: +886 928 644 966 E-mail: james.liu@gcv.com.tw Official Correspondent Title: Principal Consultant Name: Ming-Yie Jan Tel: +886 2 8785 8989 E-mail: FDA.sub@ruscert.net E. DEVICE Proprietary Name: Copioumed AAMI 3 Surgical Gown Product Code: FYA Regulation Number: 21 CFR 878.4040 Regulation Name: Surgical Apparel Device Class: Class II Review Panel: General Hospital F. INDICATION(S) FOR USE Copioumed AAMI 3 Surgical Gown is intended to be worn by operating room personnel during surgical procedures to protect both surgical patient and the operating room personnel from the transfer of microorganisms, body fluids, and particulate materials. The gown is single-use, disposable, and provided sterile, and is classified as AAMI Level 3. Page 1 of 13 pages {5} Page 2 of 13 pages G. PRIMARY PREDICTATE DEVICE Proprietary Name: Cardinal Health™ Non-Reinforced Surgical Gown Product Code: FYA Regulation Number: 21 CFR 878.4040 Regulation Name: Surgical Apparel 510(k) Number: K170762 510(k) Submitter: Cardinal Health 200, LLC Device Class: Class II Review Panel: General Hospital H. DEVICE DESCRIPTION Copioumed AAMI 3 Surgical Gown provides protection with the materials of SMS. Copioumed AAMI 3 Surgical Gown has comfort and breathability and for a better fit on the user. The neck design of Copioumed Surgical Gown is adjustable and closes with a Velcro. Copioumed Surgical Gown is available in several sizes and lengths with two models (standard performance and high standard). I. COMPARISON OF CHARACTERISTICS WITH THE PREDICTATE DEVICES {6} B. Substantial Equivalence Comparison Table-Basic Information | Element of Comparison | Proposed Device: Copioumed AAMI 3 Surgical Gown K251860 | Predicate Device: Cardinal HealthTM Non-Reinforced Surgical Gown K170762 | Comparisons | | --- | --- | --- | --- | | Product Code | FYA | FYA | N/A | | Intended Use/Indications for Use | Copioumed AAMI 3 Surgical Gown is intended to be worn by operating room personnel during surgical procedures to protect both surgical patient and the operating room personnel from the transfer of microorganisms, body fluids, and particulate materials. The gown is single-use, disposable, and provided sterile, and is classified as AAMI Level 3. | The Cardinal HealthTM Non-Reinforced Surgical Gowns are intended to be worn by operating room personnel during surgical procedures to protect the surgical patient and operating room personnel from the transfer of microorganisms, body fluids and particulate material. In addition, this surgical gown meets the requirements of AAMI Level 3 barrier protection for a surgical gown per ANSI/AAMI PB70:2012 Liquid barrier performance and classification of protective apparel and drapes intended for use in health care facilities. The Cardinal HealthTM Non-Reinforced Surgical Gowns are single use, disposable medical devices, provided sterile and non-sterile. | Similar | | Materials | Polypropylene Gown laminated with polyethylene | Polyolefin (Polypropylene) SMS nonwoven | Same | | Use | Single Use; Disposable | Single Use; Disposable | Same | {7} | Element of Comparison | Proposed Device: Copioumed AAMI 3 Surgical Gown | Predicate Device: Cardinal Health™ Non-Reinforced Surgical Gown K170762 | Comparisons | | --- | --- | --- | --- | | Design Features | Knit cuff and Velcro in Standard Knit cuff and Velcro in High Performance | Neck Closure: Hook and Loop Belt Ties Knit Cuffs Transfer Tab | Similar | | Sterility | Sterile | Sterile and non-sterile | For sterile products: Same | | Sterilization Modality | Ethylene Oxide (EO) | Ethylene Oxide (EO) | Same | | Contact Durations | Surface, Intact, < 24 hours | Surface, Intact, < 24 hours | Same | | Color | light blue | Dark blue | Different | | Size | Standard: Size M, L, XL, XXL High Performance: M, L, XL, XXL | L, XL,2XL,3XL | Different | Page 4 of 13 pages {8} C. Substantial Equivalence Comparison Table-Predicate Device-Properties | Element of Comparison | Proposed Device: Copioumed AAMI 3 Surgical Gown | Predicate Device1: Cardinal HealthTM Non-Reinforced Surgical Gown K170762 | | | Comparisons | | --- | --- | --- | --- | --- | --- | | Basis weight (oz/yd2) ASTM D3776 | 40G±4G | Test Results (3 Lots) | | Specification | Similar2 | | | | Mean (min/max) | | | | | | | Sleeve | Body | | | | | | Unit4= oz/yd4 | | | | | | | Mean = 1.32 | Mean = 1.32 | Target Mean= 1.30 | | | | | Ind Min = 1.28 | Ind Min = 1.28 | Mean Min = 1.20 | | | | | Ind Max = 1.36 | Ind Max = 1.36 | Ind Min = 1.07 | | | Grab tensile, MD* (lbs) ASTM D5034 | MD≥55N | Test Results (3 Lots) | | Specification | Similar2 | | | | Mean (min/max) | | | | | | | Sleeve | Body | | | | | | Unit = lbs | | | | | | | Mean = 21.57 | Mean = 21.57 | N/A | | | | | Ind Min = 18.60 | Ind Min = 18.60 | | | | | | Ind Max = 23.60 | Ind Max = 23.60 | | | {9} | Element of Comparison | Proposed Device: Copioumed AAMI 3 Surgical Gown | Predicate Device1: Cardinal HealthTM Non-Reinforced Surgical Gown K170762 | | | Comparisons | | --- | --- | --- | --- | --- | --- | | Grab tensile, CD* (lbs) ASTM D5034 | CD≥40N | Test Results (3 Lots) | | Specification | Similar2 | | | | Mean (min/max) | | | | | | | Sleeve | Body | | | | | | Unit = lbs | | | | | | | Mean = 13.60 | Mean = 13.60 | Target Mean = 15.00 | | | | | Ind Min = 11.20 | Ind Min = 11.20 | Mean Min = 11.00 | | | | | Ind Max = 16.0 | Ind Max = 16.0 | Ind Min = 9.50 | | | Trap Tear, MD* (lbs) ASTM D5587-15 Highest Peak | MD≥10N | Test Results (3 Lots) | | Specification | Similar3 | | | | Mean (min/max) | | | | | | | Sleeve | Body | | | | | | Unit = lbs | | | | | | | Mean = 3.47 | Mean = 3.47 | Target Mean = 4.00 | | | | | Ind Min = 2.73 | Ind Min = 2.73 | Mean Min = 2.40 | | | | | Ind Max = 4.00 | Ind Max = 4.00 | Ind Min = 2.00 | | {10} | Element of Comparison | Proposed Device: Copioumed AAMI 3 Surgical Gown | Predicate Device1: Cardinal HealthTM Non-Reinforced Surgical Gown K170762 | | | | Comparisons | | --- | --- | --- | --- | --- | --- | --- | | Trap Tear, CD* (lbs) ASTM D5587-15Highest Peak | CD≥10N | Test Results (3 Lots) | | Specification | | Similar2 | | | | Mean (min/max) | | | | | | | | Sleeve | Body | | | | | | | Unit = lbs | | | | | | | | Mean = 5.63 | Mean = 5.63 | N/A | | | | | | Ind Min = 4.67 | Ind Min = 4.67 | | | | | | | Ind Max = 7.90 | Ind Max = 7.90 | | | | | | | | | | | | | Flammability (sec) CPSC, Part 1610 | Class I | Class I | | | | Same | | Alcohol Repellency (rating) NWSP 080.8.R0 (15) | >6 | Test Results (3 Lots) | | Specification | | Similar3 | | | | Mean (min/max) | | | | | | | | Sleeve | Body | | | | | | | Mean = 9 | Mean = 9 | Target Mean = 7 | | | | | | Ind Min = 8 | Ind Min = 8 | Mean Min = 6 | | | | | | Ind Max = 9 | Ind Max = 9 | Ind Min = 5 | | | | | | | | | | | | Hydrostatic Head (cm) AATCC-127 | ≥50cm | Test Results (3 Lots) | | Specification | | Similar2 | | | | Mean (min/max) | | | | | | | | Sleeve | Body | | | | {11} | Element of Comparison | Proposed Device: Copioumed AAMI 3 Surgical Gown | Predicate Device1: Cardinal HealthTM Non-Reinforced Surgical Gown K170762 | | | Comparisons | | --- | --- | --- | --- | --- | --- | | | | Unit = cm | | | | | | | Mean = 89.90 | Mean = 89.90 | Target Mean = 70 | | | | | Ind Min = 73.95 | Ind Min = 73.95 | Mean Min = 60 | | | | | Ind Max = 100.98 | Ind Max = 100.98 | Ind Min = 53 | | | | | | | | | | Water Impact (g) AATCC-42 | ≤1.0g | Test Results (3 Lots) | | Specification | Similar2 | | | | Mean (min/max) | | | | | | | Sleeve | Body | | | | | | Unit = g | | | | | | | Mean = 0.10 | Mean = 0.10 | Target Mean = 0.10 | | | | | Ind Min = 0.07 | Ind Min = 0.07 | Mean Max = 0.30 | | | | | Ind Max = 0.13 | Ind Max = 0.13 | Ind Max = 1.0 | | {12} | lint generation | Standard Performance: log10 ≈ 3.5–3.6 High Performance log10 ≈ 3.2–3.3 | No available data | Different4 | | --- | --- | --- | --- | | Seam strength | ≥30N | No available data | Different5 | | Performance per AAMI PB70:2012 | AAMI Level 3 | AAMI Level 3 | Same | | Contact Durations | Surface, Intact, < 24 hours | Surface, Intact, < 24 hours | Same | | Biocompatibility | Under the test conditions, | Under the conditions of each study, the Cardinal HealthTM non-reinforced | Same | {13} | Element of Comparison | Proposed Device: Copioumed AAMI 3 Surgical Gown | Predicate Device^{1}: Cardinal Health^{TM} Non-Reinforced Surgical Gown K170762 | Comparisons | | --- | --- | --- | --- | | | the subject device was shown to be noncytotoxic, non-irritating and non-sensitizing per ISO 10993-5, ISO 10993-23 & ISO 10993-10. | Surgical gown is non-cytotoxic, non-irritating, and non-sensitizing per ISO 10993-1. | | Note 1: Individual Maximum (Ind. Max.): specification allows only one value at this level. Individual minimum (Ind. Min.): specification allows only one value at this level. The mean performance of the proposed device was compared to the mean specification values. Note 2: The proposed device and predicate device passed the same criteria listed in the standard. Note 3: We only compared the value of proposed device to the mean value of predicate device for the property. The proposed device and predicate device passed the same criteria listed in the standard. Note 4: No publicly available lint generation data were identified for the predicate device. Lint generation testing was performed as supplementary characterization of the proposed device. This parameter is not required under AAMI PB70. Note 5: No publicly available seam strength data were identified for the predicate device. Seam strength testing was performed as physical property characterization of the proposed device. Page 10 of 13 {14} J. SUMMARY OF NON-CLINICAL DATA The following performance data were provided to demonstrate the safety and effectiveness: | No. | Standards | Purpose | Acceptance | Results | | --- | --- | --- | --- | --- | | 1. | AATCC 42 | Water Resistance | ≤1.0G | Pass | | 2. | AATCC 127 | Hydrostatic Pressure | ≥50CM H2O | Pass | | 3. | ANSI/AAMI PB70:2012 AAMI Level 3 | Liquid Barrier Performance | Blotter weight gain ≤ 1.0 g Hydrostatic resistance ≥ 50 cm | Pass | | 4. | NWSP 080.8.R0 | Alcohol Repellency (rating) | >6 | Pass | | 5. | ASTM D3776/D3776M-17 | Weight of Woven Fabric | 40G±4G | Pass | | 6. | ASTM D5034-9 2017 | Grab Tensile, Peak Stretch, and Peak Energy - Nonwovens | MD≥55N CD≥40N | Pass | | 7. | ISO 10993-7:2008 | EO Sterilization Residuals Test | EtO < 4mg ECH < 9 mg | Pass | | 8. | ASTM D5587-15 (2019) | Standard Test Method for Tearing Strength of Fabrics by the Trapezoid Procedure | MD≥10N CD≥10N | Pass | | 10. | 16 CFR 1610 | Standard for the Flammability for Clothing Textiles | Class 1 | Pass | | 11. | ISO 9073-10:2003 | Lint and other particles generation in the dry state | Standard Performance: log10 ≈ 3.5–3.6 High Performance log10 ≈ 3.2–3.3 | Pass | | 12 | ASTM D1683 | Seam strength | ≥30N | Pass | {15} | 13. | ISO 10993-5:2009 | Cytotoxicity | The viability should be ≥ 70% of the blank. And the 50% extract of the test sample should have at least the same or a higher viability than the 100% extract. | Pass | | --- | --- | --- | --- | --- | | 14. | ISO 10993 23:2021 | Intracutaneous Irritation Test | Non-irritating | Pass | | 15. | ISO 10993-10:2010 | Maximization Test | Non-sensitizing | Pass | | 16. | EN ISO 11737-1 (2018/A1:2021) | Sterilization of health care products - Microbiological methods - Part 1: Determination of a population of microorganisms on products | ≤300 CFU/100cm2 | Pass | K. The Conclusion drawn from the Non-Clinical tests demonstrates that the subject device Copioumed AAMI 3 Surgical Gown is as safe, as effective, and performs as well as or better than the legally marketed predicate device.
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...