The BD Intelliport™ System is an automated record keeping system that incorporates patient safety features that are aligned with hospital patient records and protocols. The system is comprised of an injection port and software that enables the identification, measurement, alerting and documentation of the administration of medications to patients. The BD Intelliport™ System allows the clinician to record anesthesia-related medication administration events during pre-procedure, intra-procedure and recovery phase. The system is indicated for use by healthcare professionals in a hospital or medical center setting with patients who are receiving manually administered bolus intravenous injections as part of their care to facilitate documentation of the medications. The BD Intelliport™ System is intended for patients with body weights >20 kg. Do not use the BD Intelliport™ System with blood, blood products, biologics, or chemotherapeutics.
Device Story
System integrates into IV lines to automate anesthesia medication record-keeping. Components include injection site (sensor/reader), gateway software, charger, and mount. Clinician attaches RFID-labeled syringe to sensor; reader identifies medication, measures bolus volume, and calculates dose weight. System provides visual/auditory alerts for allergies, expired meds, and antibiotic dosing. Data transmits wirelessly via gateway to hospital EMR. Used by clinicians in hospital settings (pre-procedure, intra-procedure, recovery). Benefits include reduced manual charting errors, improved documentation accuracy, and real-time safety alerts. System supports bolus volumes 0.5–30 mL at push speeds 10–400 mL/min.
Clinical Evidence
Bench testing only. No clinical data. Testing included bolus volume measurement accuracy, sensor/reader functionality, wireless connectivity, cybersecurity, biocompatibility (ISO 10993-1), electrical/mechanical safety (IEC 60601-1/2), and human factors summative usability studies. All predetermined acceptance criteria met.
Technological Characteristics
System components: Sensor (sterile, e-beam, single-use), Reader (reusable), Gateway (software), Charger, Mount. Sensing principle: transit time measurement for velocity/volume calculation. Connectivity: Wireless to hospital EMR via Gateway. Biocompatibility: ISO 10993-1. Electrical safety: IEC 60601-1, IEC 60601-2. Software: Embedded proprietary, enhanced documentation level.
Indications for Use
Indicated for patients >20 kg receiving manually administered bolus intravenous injections in hospital/medical center settings. Used by healthcare professionals to record anesthesia-related medication administration during pre-procedure, intra-procedure, and recovery phases. Contraindicated for use with blood, blood products, biologics, or chemotherapeutics.
Regulatory Classification
Identification
An infusion pump is a device used in a health care facility to pump fluids into a patient in a controlled manner. The device may use a piston pump, a roller pump, or a peristaltic pump and may be powered electrically or mechanically. The device may also operate using a constant force to propel the fluid through a narrow tube which determines the flow rate. The device may include means to detect a fault condition, such as air in, or blockage of, the infusion line and to activate an alarm.
{0}
FDA U.S. FOOD & DRUG ADMINISTRATION
June 20, 2025
Becton Dickinson
Tim Wade
Associate Director, Regulatory Affairs
1 Becton Drive
Franklin Lakes, New Jersey 07417
Re: K243062
Trade/Device Name: BD Intelliport System; BD Intelliport Reader (516230); BD Intelliport Sensor (516229); BD Intelliport Gateway (516232); BD Intelliport Mount (516233); BD Intelliport Charger (516231)
Regulation Number: 21 CFR 880.5725
Regulation Name: Infusion Pump
Regulatory Class: Class II
Product Code: PHC, FPA
Dated: May 23, 2025
Received: May 23, 2025
Dear Tim Wade:
We have reviewed your section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (the Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database available at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Additional information about changes that may require a new premarket notification are provided in the FDA guidance documents entitled "Deciding When to Submit a 510(k) for a Change to an Existing Device"
U.S. Food & Drug Administration
10903 New Hampshire Avenue
Silver Spring, MD 20993
www.fda.gov
{1}
K243062 - Tim Wade
Page 2
(https://www.fda.gov/media/99812/download) and "Deciding When to Submit a 510(k) for a Software Change to an Existing Device" (https://www.fda.gov/media/99785/download).
Your device is also subject to, among other requirements, the Quality System (QS) regulation (21 CFR Part 820), which includes, but is not limited to, 21 CFR 820.30, Design controls; 21 CFR 820.90, Nonconforming product; and 21 CFR 820.100, Corrective and preventive action. Please note that regardless of whether a change requires premarket review, the QS regulation requires device manufacturers to review and approve changes to device design and production (21 CFR 820.30 and 21 CFR 820.70) and document changes and approvals in the device master record (21 CFR 820.181).
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR Part 803) for devices or postmarketing safety reporting (21 CFR Part 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reporting-combination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR Part 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR Parts 1000-1050.
All medical devices, including Class I and unclassified devices and combination product device constituent parts are required to be in compliance with the final Unique Device Identification System rule ("UDI Rule"). The UDI Rule requires, among other things, that a device bear a unique device identifier (UDI) on its label and package (21 CFR 801.20(a)) unless an exception or alternative applies (21 CFR 801.20(b)) and that the dates on the device label be formatted in accordance with 21 CFR 801.18. The UDI Rule (21 CFR 830.300(a) and 830.320(b)) also requires that certain information be submitted to the Global Unique Device Identification Database (GUDID) (21 CFR Part 830 Subpart E). For additional information on these requirements, please see the UDI System webpage at https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/unique-device-identification-system-udi-system.
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-devices/medical-device-safety/medical-device-reporting-mdr-how-report-medical-device-problems.
For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).
{2}
K243062 - Tim Wade
Page 3
Sincerely,
Kyran R. Gibson -S
for
Shruti Mistry
Assistant Director
DHT3C: Division of Drug Delivery and General
Hospital Devices, and Human Factors
OHT3: Office of Gastrorenal, ObGyn,
General Hospital, and Urology Devices
Office of Product Evaluation and Quality
Center for Devices and Radiological Health
Enclosure
{3}
DEPARTMENT OF HEALTH AND HUMAN SERVICES
Food and Drug Administration
Indications for Use
Form Approved: OMB No. 0910-0120
Expiration Date: 07/31/2026
See PRA Statement below.
Submission Number (if known)
K243062
Device Name
BD Intelliport System;
BD Intelliport Reader (516230);
BD Intelliport Sensor (516229);
BD Intelliport Gateway (516232);
BD Intelliport Mount (516233);
BD Intelliport Charger (516231)
Indications for Use (Describe)
The BD Intelliport™ System is an automated record keeping system that incorporates patient safety features that are aligned with hospital patient records and protocols. The system is comprised of an injection port and software that enables the identification, measurement, alerting and documentation of the administration of medications to patients.
The BD Intelliport™ System allows the clinician to record anesthesia-related medication administration events during pre-procedure, intra-procedure and recovery phase. The system is indicated for use by healthcare professionals in a hospital or medical center setting with patients who are receiving manually administered bolus intravenous injections as part of their care to facilitate documentation of the medications.
The BD Intelliport™ System is intended for patients with body weights >20 kg.
Do not use the BD Intelliport™ System with blood, blood products, biologics, or chemotherapeutics.
Type of Use (Select one or both, as applicable)
☑ Prescription Use (Part 21 CFR 801 Subpart D)
☐ Over-The-Counter Use (21 CFR 801 Subpart C)
## CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
*DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
Department of Health and Human Services
Food and Drug Administration
Office of Chief Information Officer
Paperwork Reduction Act (PRA) Staff
PRAStaff@fda.hhs.gov
“An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number.”
{4}
Becton, Dickinson and Company
Franklin Lakes, New Jersey 07417
BD Intelliport™ System
Traditional 510(k) Premarket Notification
# BD Intelliport™ System
510(k) Summary
21 CFR 807.92
As required by the Safe Medical Devices Act of 1990, coded under Section 513, Part (I)(3)(A) of the Food, Drug and Cosmetic Act, a 510(k) summary upon which substantial equivalence determination is based is as follows:
## Submitter Information:
Becton Dickinson (BD)
One Becton Drive
Franklin Lakes, NJ USA 07417
Contact Person: Tim Wade, Associate Regulatory Affairs Director
Tel: 602.830.5330
## Date Prepared:
June 17, 2025
## Subject Device:
| Device Trade Name | BD Intelliport™ System |
| --- | --- |
| 510(k) Number | K243062 |
| Regulation Number | 21 CFR 880.5725
21 CFR 880.5440 |
| Classification Product codes: | PHC, FPA |
| Device Classification Name | Infusion Safety Management Software; Set, Administration, Intravascular |
| Review Panel | General Hospital |
## Predicate Device:
| Device Trade Name | BD Intelliport™ System |
| --- | --- |
| 510(k) Number | K182092 |
| Regulation Number | 21 CFR 880.5725
21 CFR 880.5440 |
| Classification Product codes: | PHC, FPA |
| Device Classification Name | Infusion Safety Management Software; Set, Administration, Intravascular |
| Review Panel | General Hospital |
Page 1 of 12
{5}
Becton, Dickinson and Company
Franklin Lakes, New Jersey 07417
BD Intelliport™ System
Traditional 510(k) Premarket Notification
## Device Description
BD Intelliport™ System integrates into an intravenous line and automatically captures information about the anesthesia medications administered to the patient. It wirelessly transmits anesthesia medication administration information to the patient’s Electronic Medical Record (EMR) via hospital server applications (Gateway software). The BD Intelliport™ System provides core technologies that enable key functions of the system:
- Medication Identification: Informs clinician of medication and concentration along with any informational notifications such as patient allergy and expired medication reminders. This occurs when syringes with the correct type of RFID encoded label are attached.
- Dose Measurement: Measures volume of drug administered to the patient through the system, then calculates dose weight.
- Automatic Charting: Wirelessly transmits measured doses to the EMR.
The following are the main system components:
- BD Intelliport™ Injection Site which is comprised of the following two components:
- BD Intelliport™ Sensor
- BD Intelliport™ Reader
- BD Intelliport™ Mount (optional accessory)
- BD Intelliport™ 2-Bay Charger (accessory)
- BD Intelliport™ Gateway
## Indications for Use:
The BD Intelliport™ System is an automated record keeping system that incorporates patient safety features that are aligned with hospital patient records and protocols. The system is comprised of an injection port and software that enables the identification, measurement, alerting and documentation of the administration of medications to patients.
The BD Intelliport™ System allows the clinician to record anesthesia-related medication administration events during pre-procedure, intra-procedure and recovery phase. The system is indicated for use by healthcare professionals in a hospital or medical center setting with patients who are receiving manually administered bolus intravenous injections as part of their care to facilitate documentation of the medications.
The BD Intelliport™ System is intended for patients with body weights >20 kg.
Do not use the BD Intelliport™ System with blood, blood products, biologics, or chemotherapeutics.
Page 2 of 12
{6}
Becton, Dickinson and Company
Franklin Lakes, New Jersey 07417
BD Intelliport™ System
Traditional 510(k) Premarket Notification
## Comparison to Predicate Device:
The subject BD Intelliport System has the following similarities to the predicate BD Intelliport System (K182092):
- Same intended use
- Same patient population and users
- Same fundamental scientific technology
- Same mechanism of action
- Same sterility assurance levels
- Similar materials
The subject and predicate devices have the following differences:
- Improved flow algorithm
- Modified indications for use
- Modifications to system components and design
- RFID reading capability
- Updated Cybersecurity profile
Page 3 of 12
{7}
Becton, Dickinson and Company
Franklin Lakes, New Jersey 07417
BD Intelliport™ System
Traditional 510(k) Premarket Notification
A detailed comparison of technological characteristics is provided in the table below:
| Attribute | Subject Device
(BD Intelliport System) | Predicate Device
(K182092– BD Intelliport System) | Significance to Substantial Equivalence |
| --- | --- | --- | --- |
| **Intended Use/ Indications for Use** | | | |
| Intended Use | The BD Intelliport System is intended to automate the record keeping of bolus intravenous injections. | The BD Intelliport system is intended to automate the record keeping of bolus intravenous injections. | Identical |
| Indications for Use | The BD Intelliport system is an automated record keeping system that incorporates patient safety features that are aligned with hospital patient records and protocols. The system is comprised of an injection port and software that enables the identification, measurement, alerting and documentation of the administration of medications to patients.
The BD Intelliport system allows the clinician to record anesthesia-related medication administration events during pre-procedure, intra-procedure, and recovery phase. The system is indicated for use by healthcare professionals in a hospital or medical center setting with patients who are receiving manually administered bolus intravenous injections as part of their care to facilitate documentation of the medications. | The BD Intelliport system is an automated record keeping system that incorporates patient safety features that are aligned with hospital patient records and protocols. The system is comprised of an injection port and software that enables the identification, measurement, alerting and documentation of the administration of medications to patients.
The BD Intelliport system allows the clinician to record anesthesia-related medication administration events during preop, intra-op, and PACU. The system is indicated for use by healthcare professionals in a hospital or medical center setting with patients who are receiving manually administered bolus intravenous injections as part of their care to facilitate documentation of the medications. | Different
The indications for use remain unchanged between the subject device and the predicate device except for the change from preop, intra-op, and PACU to pre-procedure, intra- procedure and recovery phase to clarify that the subject device can be used in different use environments, by qualified clinicians as substantiated by the human factors testing.
The removal of the contraindication "The BD Intelliport System is not intended for use with refrigerated medications (excluding cefazolin)" is appropriately substantiated by the verification and validation testing. |
Page 4 of 12
{8}
Becton, Dickinson and Company
Franklin Lakes, New Jersey 07417
BD Intelliport™ System
Traditional 510(k) Premarket Notification
| Attribute | Subject Device
(BD Intelliport System) | Predicate Device
(K182092– BD Intelliport System) | Significance to Substantial Equivalence |
| --- | --- | --- | --- |
| | The BD Intelliport™ system is intended for patients with body weights >20 kg.
Do not use the BD Intelliport™ System with blood, blood products, biologics, or chemotherapeutics. | The BD Intelliport™ system is intended for patients whose body weights are >20kg.
The BD Intelliport™ system is not intended for use with blood, blood products, biologics, or chemotherapeutics.
The BD Intelliport™ system is not intended for use with refrigerated medications (excluding cefazolin). | |
| Technology and Design | | | |
| Components | • Intelliport Injection Site which consists of:
• Intelliport Reader
• Intelliport Sensor
• Intelliport Gateway (software)
• Intelliport 2-Bay Charger (accessory)
• Intelliport Mount (optional accessory) | • Intelliport Injection Site which consists of:
• Intelliport Base
• Intelliport Sensor
• Intelliport Tablet
• Intelliport Radio
• Intelliport Gateway (software)
• Intelliport 5-Bay Charger (accessory) | Different
Modifications have been made to the subject device design to allow for improved user interaction.
Additional offering of optional mount accessory. |
| Syringe reading capability | RFID labeled drug syringes | 2D Barcode labeled drug syringes | Different
Both devices utilize electronically encoded medication syringes.
Differences have been qualified through verification testing. |
| Compatible Accessories | • 1 mL-30 mL luer lock syringes
• Intravenous (IV) administration tubing and IV extension sets and accessories having luer lock connectors. | • 1 mL-60 mL luer lock syringes
• Intravenous (IV) administration tubing and IV extension sets and accessories having luer lock connectors. | Different
The subject device has limited the size of luer lock syringes within the range of the predicate devices.
Differences have been qualified through verification and human factors testing. |
Page 5 of 12
{9}
Becton, Dickinson and Company
Franklin Lakes, New Jersey 07417
BD Intelliport™ System
Traditional 510(k) Premarket Notification
| Attribute | Subject Device
(BD Intelliport System) | Predicate Device
(K182092– BD Intelliport System) | Significance to Substantial
Equivalence |
| --- | --- | --- | --- |
| Flow Algorithm | Algorithm calculates velocity based on transit time, the speed of sound of the material and the fluid path length | Algorithm calculates velocity based on transit time, the speed of sound of the material and the fluid path length | Different
The fundamental design of the algorithm between the predicate and subject devices is the same.
The subject device calculations have been updated to allow for broader range of drugs, including refrigerated medications. This has been qualified through verification testing. |
| **Injection Site: Sensor** | | | |
| Physical/ Mechanical Specifications (Sensor) | Fluid Connection: 2 ports, BD Luer-Lok™ connector
Port: 3-way stopcock with integrated BD SmartSite™ needle free valve
Useful Life: >24hrs to 30 days
Sensor Dead Volume: ≤0.12 mL following injection.
Port Capacity: 120 Injections | Fluid Connection: 1 ports, BD Luer-Lok™ type fitting
Port: BD Q-Syte™ needle free valve
Useful Life: >24hrs to 30 days
Sensor Dead Volume: <0.3 mL
Port Capacity: 100 Injections | Different
Differences in tolerances and dimensions between the subject device and predicate device are made to accommodate improved design features.
Design verification and validation testing demonstrates that the subject device performs as intended. |
| **Injection Site: Reader** | | | |
| Function | Reader decodes drug information from sensor, displays information on screen, and communicates drug information to the gateway. Serves as user interface for clinician. | Tablet decodes drug information from sensor, displays information on screen, and communicates drug information to the gateway. Serves as user interface for clinician. | Identical
Although the tablet component has been changed to the reader their function is identical. |
Page 6 of 12
{10}
Becton, Dickinson and Company
Franklin Lakes, New Jersey 07417
BD Intelliport™ System
Traditional 510(k) Premarket Notification
| Attribute | Subject Device
(BD Intelliport System) | Predicate Device
(K182092– BD Intelliport System) | Significance to Substantial
Equivalence |
| --- | --- | --- | --- |
| Computing Platform
Operating Systems | Modified proprietary embedded software | Proprietary embedded software | Different
The updated operating systems have been qualified through software, cybersecurity and design verification activities. |
| Volume measurement accuracy | ± 10% (for volumes >1.0 mL)
± 0.2mL (for volumes 0.4 – 1.0 mL) | ± 10% (for volumes >1.0 mL)
± 0.2mL (for volumes 0.4 – 1.0 mL) | Identical |
| Volume Measurement Resolution | Uniform increments of 0.5 mL | Uniform increments of 0.5 mL | Identical |
| Volume Measurement Performance Window | Average Push Speed: 10ml/min to 400 ml/min
Volume Range: 0.5ml to 30ml | Average Push Speed: 10ml/min to 400 ml/min
Volume Range: 0.5ml to 60ml | Different
The subject device lowers the upper limit of the volume range from 60ml to 30ml. This change has been qualified through verification and human factors testing. |
| Notifications | Includes Drug Name and Concentration
Visual and auditory notification on the screen
Alerts for allergy, antibiotic dosing reminder, and expired medication alerts | Includes Drug Name and Concentration
Alerts for allergy and antibiotic dosing reminder
Visual and auditory notification on the screen | Different
Addition of expired medication alerts has been qualified through design verification and validation testing. |
| Dose History List | Contains doses sent to the EMR
Contains doses missing drug name and concentration
Contains doses flagged with a potential volume error message | Contains doses sent to the EMR
Contains doses missing drug name and concentration
Contains doses flagged with a potential volume error message | Identical |
Page 7 of 12
{11}
Becton, Dickinson and Company
Franklin Lakes, New Jersey 07417
BD Intelliport™ System
Traditional 510(k) Premarket Notification
| Attribute | Subject Device
(BD Intelliport System) | Predicate Device
(K182092– BD Intelliport System) | Significance to Substantial
Equivalence |
| --- | --- | --- | --- |
| Charger (Hardware) | | | |
| Specifications | Storage Capacity: 2 Readers
Input Voltage: 100-240 VAC, 50 – 60Hz
Output Voltage: 5V
Output Current: 3A | Storage Capacity: 5 Bases
Input Voltage: 100-240 VAC, 50 – 60 Hz
Output Voltage: 5V
Output Current: 4A | Different
The updated charger has been qualified as part of design verification activities. |
| Gateway (Software) | | | |
| EMR connectivity | Send/receive medication data to/from EMR | Send/receive medication data to/from EMR | Identical |
| Encoded drug table (EDT) | 306 drugs on ISDT (Intelliport System Drug Table) | 161 drugs on EDT (Encoded Drug Table) | Different
The subject device algorithm has been updated to allow for additional drugs to be qualified as part of design verification testing. |
| Provisioning | Semi-automated method to provision the device on network | Manual method to provision the device on network | Different
The subject device has been updated to provide a semi-automated way of connecting to Wifi to improve use of the system and has been qualified through software testing. |
| System | | | |
| Software Documentation Level | Enhanced documentation level | Major level of concern – Class C | Identical
The level of concern/documentation level is the same between the predicate and subject devices. |
Page 8 of 12
{12}
Becton, Dickinson and Company
Franklin Lakes, New Jersey 07417
BD Intelliport™ System
Traditional 510(k) Premarket Notification
| Attribute | Subject Device
(BD Intelliport System) | Predicate Device
(K182092– BD Intelliport System) | Significance to Substantial
Equivalence |
| --- | --- | --- | --- |
| Biocompatibility | Biocompatible per ISO 10993-1
Sensor: Externally communicating medical device with blood path, indirect patient contact. Prolonged contact (>24 hr to 30 days)
Reader: Direct contact with intact skin. Prolonged contact (>24 hours to 30 days)
Mount & Charger: No patient contact | Biocompatible per ISO 10993-1
Sensor: Externally communicating medical device with blood path, indirect patient contact. Prolonged contact (>24 hr to 30 days)
Base: Direct contact with intact skin. Prolonged contact (>24 hours to 30 days)
Charger: No patient contact | Identical
Both devices share common contact duration and type of intended tissue contact for the Injection system (reader and sensor).
The biological evaluation, conducted in accordance with ISO10993-1, demonstrated that the subject device (sensor and reader) is biocompatible for its intended use. |
| Electrical Safety & Electromagnetic Compatibility | Conformity to
IEC 60601-1
IEC 60601-2 | Conformity to
IEC 60601-1
IEC 60601-2 | Identical
The updated design of the subject device has been tested for electrical safety and electromagnetic compatibility. |
| Sterilization | Sensor: Sterile, Single Use, e-beam, SAL 10^{-6}
Reader: Non-sterile, Reusable
Mount: Non-sterile, Reusable
Charger: Non-sterile, Reusable | Sensor: Sterile, Single Use, Ethylene Oxide, SAL 10^{-6}
Base: Non-sterile, Reusable
Tablet: Non-sterile, Reusable
Charger: Non-sterile, Reusable | Different
Both devices have components delivered sterile or non-sterile and both are sterilized using FDA established methods. The sterility of the subject is supported by sterilization validation testing. |
Page 9 of 12
{13}
Becton, Dickinson and Company
Franklin Lakes, New Jersey 07417
BD Intelliport™ System
Traditional 510(k) Premarket Notification
# Performance Testing
To demonstrate substantial equivalence of the subject device to the predicate device, non-clinical testing was conducted. Using FDA Guidance, recognized consensus standards, and internal requirements the following tests were conducted on the subject device:
- Sensor Testing
- Bolus volume measurement accuracy
- Sensor barcode scan
- Sensor flow rate
- Sensor readiness
- Sensor detect
- Detachment force of sensor from reader
- Sensor tensile and leak testing
- Syringe attachment and detachment detection
- Smartvalve detection
- Sensor IV Port ISO 80369-7 Testing
- Smartsite™ 80369-7 Testing
- Particulate Testing per USP 788 & ISO 8536-4
- Reader Testing
- Cleaner compatibility
- Charging initiation
- Audio test
- User reader touchscreen interaction
- Decoding barcode symbology
- Sensor detect
- Reader Sensor Barcode Scan
- Smartvalve Detection
- Syringe attachment and detachment detection
- Reader syringe decoding coverage test
- Reader false read
- Decoding response time
- Wifi functionality
- Dose transmission time
- Bolus volume measurement under operating environmental conditions
- Battery charging test
- Mount Testing
- Positive indication upon injection site attachment
- Retention force of injection site to mount
- Usage life
Page 10 of 12
{14}
Becton, Dickinson and Company
Franklin Lakes, New Jersey 07417
BD Intelliport™ System
Traditional 510(k) Premarket Notification
- Charger Testing
- Charger stays in place during use
- One handed insertion and removal
- Charge bay keyed for installation
- Bay powered when reader installed
- Output current
- Operating temperature
- Cleaning chemical compatibility
- LED light indicator
- Reader screen visibility
- Verify charger does not scratch reader
- Dimensions/weight
- Surface temperature limits
- Reverse input polarity protection
- Wear resistance
- Drop test
- Power supply cord length
- Software validation & cybersecurity assessment
- Reprocessing/cleaning validation
- Electromagnetic Compatibility, Wireless, and Electrical, Mechanical, and Thermal (EMT) Safety Testing
- Biocompatibility
- Packaging Testing
## Human Factors Evaluation
A human factors evaluation, including formative and summative usability studies were conducted to assess critical tasks completed by intended device users while operating the device. Testing was conducted in accordance with FDA guidance “Applying Human Factors and usability Engineering to medical devices” (2016). The results of the studies and the analysis of residual risk, show that the use-related risks associated with the Intelliport™ System have been mitigated to acceptable levels and support that the subject device does not raise different questions of safety or effectiveness.
## Conclusion
The subject device, the BD Intelliport™ System, has met all predetermined acceptance criteria for the non-clinical and human factors testing conducted in accordance with relevant FDA guidance, recognized consensus standards, and internal requirements. The differences in
Page 11 of 12
{15}
Becton, Dickinson and Company
Franklin Lakes, New Jersey 07417
BD Intelliport™ System
Traditional 510(k) Premarket Notification
technological characteristics do not change the intended use of the device and the testing conducted supports the technology changes do not raise different questions of safety or effectiveness when compared to the predicate device. Therefore, the subject device is considered substantially equivalent to the predicate BD Intelliport™ System.
Page 12 of 12
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.