← Product Code [QEW](/productcode/QEW) · K231022

# Pounce™ Thrombectomy System (K231022)

_Surmodics,Inc. · QEW · Jun 12, 2023 · Cardiovascular · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K231022

## Device Facts

- **Applicant:** Surmodics,Inc.
- **Product Code:** [QEW](/productcode/QEW.md)
- **Decision Date:** Jun 12, 2023
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 870.5150
- **Device Class:** Class 2
- **Review Panel:** Cardiovascular
- **Attributes:** Therapeutic

## Indications for Use

The Pounce Thrombectomy System is intended for the non-surgical removal of thrombi and emboli from the peripheral arterial vasculature. The Pounce LP Thrombectomy System is indicated for use in vessels ranging from 2 mm in diameter.

## Device Story

Percutaneous catheter system for mechanical thrombus removal in peripheral arterial vasculature; used by physicians in clinical settings. System components: delivery catheter, basket wire with two self-expanding baskets, funnel catheter, cleaning tools. Physician delivers basket wire to thrombus site via delivery catheter; baskets capture thrombus; funnel catheter collects and retrieves thrombus. Radiopaque markers on basket struts and catheter tip provide fluoroscopic visualization. System introduced through guide sheath. Benefits include non-surgical thrombus removal, potentially restoring blood flow in peripheral arteries.

## Clinical Evidence

No clinical data. Substantial equivalence supported by bench testing, including dimensional, radial force, tensile strength, kink, leak, fatigue, simulated use, radiopacity, and biocompatibility testing.

## Technological Characteristics

Percutaneous catheter system; includes delivery catheter, basket wire with self-expanding baskets, and funnel catheter. Features radiopaque markers for fluoroscopic guidance. Components are flexible; includes integrated handle with slider button for funnel deployment. Biocompatible materials used. Sterilized device.

## Regulatory Identification

An embolectomy catheter is a balloon-tipped catheter that is used to remove thromboemboli, i.e., blood clots which have migrated in blood vessels from one site in the vascular tree to another.

## Predicate Devices

- Pounce™ Thrombectomy System ([K220501](/device/K220501.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

Image /page/0/Picture/0 description: The image shows the logo of the U.S. Food & Drug Administration (FDA). The logo consists of two parts: a symbol on the left and the FDA acronym with the full name of the agency on the right. The symbol on the left is a stylized representation of a human figure, while the FDA acronym is in blue, followed by the full name of the agency, "U.S. Food & Drug Administration," in a smaller font size.

June 12, 2023

Surmodics Inc. Holly Ramirez Senior Staff Regulatory Affairs Specialist 7905 Golden Triangle Drive Suite 190 Eden Prairie, Minnesota 55344

Re: K231022

Trade/Device Name: Pounce™ Thrombectomy System Regulation Number: 21 CFR 870.5150 Regulation Name: Embolectomy Catheter Regulatory Class: Class II Product Code: QEW Dated: April 10, 2023 Received: April 10, 2023

Dear Holly Ramirez:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database located at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's

{1}------------------------------------------------

requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803) for devices or postmarketing safety reporting (21 CFR 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reportingcombination-products); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-device-safety/medical-device-reportingmdr-how-report-medical-device-problems.

For comprehensive regulatory information about mediation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medicaldevices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-device-advice-comprehensive-regulatoryassistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).

Sincerely,

Ariel G. Ash- Digitally signed by
shakoor -S Ariel G. Ash-shakoor -S
Date: 2023.06.12
17:03:14 -04'00'

For

Gregory O'Connell Assistant Director DHT2C: Division of Coronary and Peripheral Intervention Devices OHT2: Office of Cardiovascular Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health

Enclosure

{2}------------------------------------------------

# Indications for Use

510(k) Number (if known) K231022

Device Name Pounce™ Thrombectomy System

#### Indications for Use (Describe)

The Pounce Thrombectomy System is intended for the non-surgical removal of thrombi and emboli from the peripheral arterial vasculature.

The Pounce LP Thrombectomy System is indicated for use in vessels ranging from 2 mm in diameter.

Type of Use (Select one or both, as applicable)

| <span> <span style="font-size: 14px;">☑</span> Prescription Use (Part 21 CFR 801 Subpart D)   </span> |
|-------------------------------------------------------------------------------------------------------|
| <span> <span style="font-size: 14px;">☐</span> Over-The-Counter Use (21 CFR 801 Subpart C)   </span>  |

### CONTINUE ON A SEPARATE PAGE IF NEEDED.

This section applies only to requirements of the Paperwork Reduction Act of 1995.

#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*

The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:

> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov

"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."

{3}------------------------------------------------

Image /page/3/Picture/0 description: The image contains the word "SURMODICS" in a bold, sans-serif font. To the left of the word is a stylized logo. The logo is a geometric shape with two overlapping sections, one in a darker blue and the other in a lighter teal color.

# 510(k) Summary

Date Prepared: 10 April 2023

### Submitters Name/Contact Person

## 510K Submitter and Contact for Routine Correspondence

Holly Ramirez Senior Staff Regulatory Affairs Specialist 7905 Golden Triangle Dr. Ste. 190 Eden Prairie, MN 88344 Phone (952)-500-7545 Email: hramirez@surmodics.com

## 510k Submitter Establishment Registration Number

3014687026

| General Information        |                                       |
|----------------------------|---------------------------------------|
| Trade Name:                | Pounce™ LP Thrombectomy System        |
| Common / Usual Name:       | Thrombectomy Catheter                 |
| Classification Name        | Embolectomy Catheter                  |
| Regulation/Product Code    | 21 CFR 870.5150                       |
| Device Panel               | Cardiovascular                        |
| Regulatory Classification: | Class II                              |
| Product Code:              | QEW                                   |
| Predicate Device:          | Pounce™ Thrombectomy System (K220501) |

{4}------------------------------------------------

Image /page/4/Picture/0 description: The image shows the logo for Surmodics. The logo consists of a stylized blue and green icon to the left of the company name, "SURMODICS," which is written in a simple, sans-serif font. The icon appears to be an abstract representation of folded or layered shapes, with the blue color dominating and a touch of green at the bottom. The overall design is clean and modern.

# Device Description

The Surmodics Pounce™ Thrombectomy System is a percutaneous catheter system designed to facilitate mechanical thrombus removal in the peripheral arterial vasculature. The system is comprised of three separate components: a Delivery Catheter, a Basket Wire, the Funnel Catheter, and cleaning tool accessories. The system contains radiopaque components to conduct the procedure and is intended to be introduced through appropriately sized guide sheath.

The Delivery Catheter is flexible and designed to deliver the Basket Wire to the location of the thrombus. Incorporated in the catheter is a radiopaque marker band located at the distal tip.

The Basket Wire is comprised of two distal self-expanding baskets mounted a core wire for capturing thrombus. The distal capture baskets have integral radiopaque markers mounted on the struts of the basket for basket visibility under fluoroscopy.

The Funnel Catheter is used for thrombus collection and retrieval in conjunction with the Basket Wire. The Funnel Catheter is comprised of an inner funnel catheter and an outer delivery catheter. The two catheters work together to allow unsheathing of the funnel using the slider button on the integrated handle.

#### Indication for Use

The Pounce™ Thrombectomy System is intended for the non-surgical removal of thrombi and emboli from the peripheral arterial vasculature.

The Pounce LP Thrombectomy System is indicated for use in vessels ranging from 2 mm to 4 mm in diameter.

### Comparison of Technological Characteristics

The Pounce LP Thrombectomy System is substantially equivalent to the previous Pounce Thrombectomy System (K220501) in design, intended use, principles of use, biocompatibility, sterility, and labeling. Changes to the predicate device that have led to the submission of this new 510(k) are to extend the product line to include the use in vessels ranging from 2 mm. The smaller basket wire and catheter size has been verified through performance bench and biocompatibility testing and determined to be substantially equivalent.

{5}------------------------------------------------

Image /page/5/Picture/0 description: The image shows the logo for Surmodics. The logo consists of a blue and green abstract shape on the left, followed by the word "SURMODICS" in a dark gray sans-serif font. The abstract shape appears to be a stylized ribbon or folded paper design, with the blue portion on top and the green portion underneath.

# Performance Bench Testing

Results of design verification and biocompatibility testing demonstrates that the technological and material differences identified do not raise new questions of safety or effectiveness compared to the predicate device. The Pounce LP Thrombectomy System has been evaluated through the following tests:

- -Dimensional
- Radial Force -
- -Tensile Strength
- -Kink
- -Air and Liquid Leak
- Basket Wire Fatigue -
- -Atraumatic Surfaces
- -Simulated Use
- Removal Force -
- -Radiopacity
- -Luer Compatibility
- Ancillary Device Compatibility -
- Torque Strength -
- -Rated Burst Pressure
- -Coating Integrity
- Packaging/Distribution -
- -Biocompatibility

# Clinical Studies and Testing

No clinical studies were required for the Pounce Thrombectomy System.

# Conclusion

Based on the device description, materials, technological characteristics, and accompanying performance and biocompatibility data it can be concluded that the device modifications made to the Pounce LP Thrombectomy System are substantially equivalent to the predicate device and the device will continue to function per its intended use.

---

**Source:** [https://fda-staging.innolitics.com/device/K231022](https://fda-staging.innolitics.com/device/K231022)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
