K222054 · Denti.Ai Technology, Inc. · LLZ · Nov 22, 2022 · Radiology
Device Facts
Record ID
K222054
Device Name
Denti.AI Auto-Chart
Applicant
Denti.Ai Technology, Inc.
Product Code
LLZ · Radiology
Decision Date
Nov 22, 2022
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 892.2050
Device Class
Class 2
Attributes
AI/ML, Software as a Medical Device, Real-World Evidence
Real-World Evidence
Submission
Device
Sponsor
RWD Sources
RWE Use Summary
Key Tags
K222054 · Nov 22, 2022
Denti.AI Auto-Chart
Denti.Ai Technology, Inc.
Retrospective dental X-ray images from multiple US dental clinics
The device performance was validated using a retrospective dataset of 336 clinical X-ray images to assess the accuracy of dental structure detection, numbering, and restorative finding identification.
Adult patients (≥22 years old); Sample Size: 336 images (1 image per patient); Number of Sites: Multiple dental clinics across the US
Not applicable for this study
Sensitivity and PPV of teeth detection, classification accuracy of teeth numbering, restorative findings identification, and manual charting reduction rate.
Standalone study: 336 images (1 image per patient) from multiple dental clinics across the US.
2 (dental hygienists) + 1 (dentist)
Indications for Use
Denti.AI Auto-Chart is a Medical Image Management and Processing System (MIMPS) device aimed to assist dental professionals (Users), comprising general dentists, dental specialists, and dental hygienists, in detecting dental structures and producing dental charting data based on the interpretation of intraoral and extraoral 2D X-Ray images. Denti.AI Auto-Chart is intended to assist in: Detecting natural dental structures: teeth and missing teeth . Detecting dental structures added through past restorative treatment: implants, crowns, pontics, endodonic treatment, fillings . Choosing treatment options . Producing dental charts based on image analysis results as well as conditions added manually or produced by integrated CAD devices The device is aimed to be used with images from the adult population only (≥22 years old and do not have remaining primary teeth). The device is not intended as a replacement for a complete clinician's review or clinical judgment that considers other relevant information from the image or patient history.
Device Story
Cloud-based software; inputs 2D intraoral/extraoral X-ray images (JPEG, TIFF, PNG, BMP, DICOM). Uses AI-based algorithms to detect/number teeth and identify restorative treatments (implants, crowns, fillings, etc.). Produces automated dental charts to assist clinicians in treatment planning. Operated by dental professionals in clinical settings; output used as decision-support tool; clinician retains final judgment. Reduces manual charting operations by >70%. Benefits patient through efficient, standardized dental record-keeping.
Clinical Evidence
Bench testing only; no clinical data. Study used 336 images from multiple US clinics. Primary endpoints included sensitivity and PPV for teeth detection (97.4%, 99.6%), teeth numbering accuracy (85.9%), and restorative finding identification (88.5% sensitivity, 98.3% specificity). Manual charting reduction rate was 71.2%. Stratified analysis showed consistent performance across age, gender, and sensor types.
Technological Characteristics
Software-only device; cloud-based platform. Uses AI-based algorithms for image analysis. Supports standard image formats (DICOM, JPEG, TIFF, PNG, BMP). No patient-contacting components; no electrical emissions. Software classified as Moderate Level of Concern.
Indications for Use
Indicated for adult patients (≥22 years old, no primary teeth) to assist dental professionals (dentists, specialists, hygienists) in detecting dental structures (teeth, missing teeth, implants, crowns, pontics, endodontic treatments, fillings) and generating dental charts from 2D intraoral/extraoral X-rays.
Regulatory Classification
Identification
A medical image management and processing system is a device that provides one or more capabilities relating to the review and digital processing of medical images for the purposes of interpretation by a trained practitioner of disease detection, diagnosis, or patient management. The software components may provide advanced or complex image processing functions for image manipulation, enhancement, or quantification that are intended for use in the interpretation and analysis of medical images. Advanced image manipulation functions may include image segmentation, multimodality image registration, or 3D visualization. Complex quantitative functions may include semi-automated measurements or time-series measurements.
Special Controls
*Classification.* Class II (special controls; voluntary standards—Digital Imaging and Communications in Medicine (DICOM) Std., Joint Photographic Experts Group (JPEG) Std., Society of Motion Picture and Television Engineers (SMPTE) Test Pattern).
{0}------------------------------------------------
November 22, 2022
Image /page/0/Picture/1 description: The image shows the logos of the Department of Health and Human Services and the Food and Drug Administration (FDA). The Department of Health and Human Services logo is on the left, and the FDA logo is on the right. The FDA logo includes the letters "FDA" in a blue square, followed by the words "U.S. FOOD & DRUG ADMINISTRATION" in blue text.
Denti.AI Technology Inc. % Donna-Bea Tillman Senior Consultant Biologics Consulting 1555 King Street ALEXANDRIA, VA 22314
Re: K222054
Trade/Device Name: Denti.AI Auto-Chart Regulation Number: 21 CFR 892.2050 Regulation Name: Medical Image Management And Processing System Regulatory Class: Class II Product Code: LLZ Dated: October 25, 2022 Received: October 25, 2022
Dear Donna-Bea Tillman:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database located at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal
{1}------------------------------------------------
statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803) for devices or postmarketing safety reporting (21 CFR 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reportingcombination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-device-safety/medical-device-reportingmdr-how-report-medical-device-problems.
For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medicaldevices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-device-advice-comprehensive-regulatoryassistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).
Sincerely,
Lu Jiang 2022.11.22
18:06:58 -05'00'
Lu Jiang, Ph.D. Assistant Director Diagnostic X-Ray Systems Team DHT8B: Division of Radiological Imaging Devices and Electronic Products OHT8: Office of Radiological Health Office of Product Evaluation and Quality Center for Devices and Radiological Health
{2}------------------------------------------------
### Indications for Use
510(k) Number (if known) K222054
Device Name Denti.AI Auto-Chart
Indications for Use (Describe)
Denti. Al Auto-Chart is a Medical Image Management and Processing System (MIMPS) device aimed to assist dental professionals (Users), comprising general dental specialists, and dental hygienists, in detecting dental structures and producing dental charting data based on the interpretation of intraoral and extraoral 2D X-Ray images.
Denti.AI Auto-Chart is intended to assist in:
· Detecting natural dental structures: teeth and missing teeth
· Detecting dental structures added through past restment: implants, crowns, pontics, endodonic treatment, fillings
· Choosing treatment options
• Producing dental charts based on image analysis results as well as conditions added manually or produced by integrated CAD devices
The device is aimed to be used with images from the adult population only (≥22 years old and do not have remaining primary teeth). The device is not intended as a replacement for a complete clinical judgment that considers other relevant information from the image or patient history.
Type of Use (Select one or both, as applicable)
| Prescription Use (Part 21 CFR 801 Subpart D) | <span style="font-family: DejaVu Sans, sans-serif">✖</span> |
|----------------------------------------------|-------------------------------------------------------------|
| Over-The-Counter Use (21 CFR 801 Subpart C) | <span>☐</span> |
### CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
{3}------------------------------------------------
In accordance with 21 CFR 807.87(h) and 21 CFR 807.92 the 510(k) Summary for the Denti.AI Auto-Chart is provided below.
#### 1. SUBMITTER
| Applicant: | Denti.AI Technology Inc.<br>99 Yorkville Ave, Suite 214<br>Toronto, Ontario, Canada M5R3K5 |
|--------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Contact/Submission<br>Correspondent: | Donna-Bea Tillman, Ph.D.<br>Biologics Consulting Group<br>1555 King Street, Suite 300<br>Alexandria, VA 22314<br>(410) 531-6542<br>dtillman@biologicsconsulting.com |
| Date Prepared: | October 24, 2022 |
#### 2. DEVICE
| Device Trade Name: | Dent.AI Auto-Chart |
|---------------------|-------------------------------------------------------------------|
| Device Common Name: | Image Processing System |
| Classification Name | 21 CFR 892.2050 Medical Image Management and<br>Processing System |
| Regulatory Class: | II |
| Product Code: | LLZ |
#### 3. PREDICATE DEVICE
Predicate Device: Ewoosoft EzOrtho V1.3 (K220003)
#### DEVICE DESCRIPTION 4.
Denti.AI Auto-Chart is a Medical Image Management and Processing System (MIMPS) device aimed to assist dental professionals in detecting dental structures and producing dental charting data based on the interpretation of 2D X-Ray images. The device is intended to assist dental professionals in detecting teeth and missing teeth, numbering teeth, and detecting dental structures added through past restorative treatment, including implants, crowns, pontics, endodontic treatment, and fillings.
{4}------------------------------------------------
#### INTENDED USE/INDICATIONS FOR USE 5.
Denti.AI Auto-Chart is a Medical Image Management and Processing System (MIMPS) device aimed to assist dental professionals (Users), comprising general dentists, dental specialists, and dental hygienists, in detecting dental structures and producing dental charting data based on the interpretation of intraoral and extraoral 2D X-Ray images.
Denti.AI Auto-Chart is intended to assist in:
- Detecting natural dental structures: teeth and missing teeth .
- . Detecting dental structures added through past restorative treatment: implants, crowns, pontics, endodontic treatment, fillings
- . Choosing treatment options
- . Producing dental charts based on image analysis results as well as conditions added manually or produced by integrated CAD devices
The device is aimed to be used with images from the adult population only (≥22 years old and do not have remaining primary teeth). The device is not intended as a replacement for a complete clinician's review or clinical judgment that considers other relevant information from the image or patient history.
#### SUBSTANTIAL EQUIVALENCE 6.
## Comparison of Indications
Both the subject Denti.AI Auto-Chart and the predicate Ewoosoft EzOrtho are intended for use to create dental charts to track patient information and treatments. Both devices are intended for use by trained dental practitioners who are responsible for making the final clinical decisions. The devices differ in the type of dental treatment (general dentistry for Auto-Chart and orthodontics for EzOrtho), but this does not change the fundamental purpose of the devices which is to create patient records.
## Technological Comparisons
Table 1 compares the key technological feature of the subject devices to the predicate device Ewoosoft EzOrtho V1.3 (K220003).
| | Denti-AI Auto-Chart<br>(Proposed Device) | Ewoosoft EzOrtho V1.3 (K220003)<br>(Predicate Device) |
|------------------------------|-------------------------------------------------------------------|----------------------------------------------------------------|
| 510(k) Number | TBD | K220003 |
| Applicant | Denti.AI Technology Inc. | Ewoosoft Co., Ltd. |
| Classification<br>Regulation | CFR 892.2050 Medical Image<br>Management and Processing<br>System | CFR 892.2050 Medical Image<br>Management and Processing System |
#### Technological Comparison Table 1:
{5}------------------------------------------------
| | Denti-AI Auto-Chart<br>(Proposed Device) | Ewoosoft EzOrtho V1.3 (K220003)<br>(Predicate Device) |
|-----------------------------------|-------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Product Code | LLZ | LLZ |
| Prescription Use | Yes | Yes |
| Intended Users | Dental professionals | Licensed practitioners or dentists |
| Patient Population | Adult patients receiving general<br>dental care | Patients receiving orthodontic care |
| Platform | Cloud-based | IBM-compatible PC or PC network |
| Imaging Modality | 2-D intraoral or extraoral X-rays | Digital camera or radiological<br>imaging device |
| Supported File<br>formats | jpeg, jpg, tiff, tif, png, bmp,<br>DICOM | bmp, jpg, png, tif, DICOM |
| Detection Features | Detecting and numbering teeth<br>Detecting and identifying past<br>restorative treatments | Detecting anatomical landmarks |
| Image<br>manipulation<br>features | Invert, brightness, contrast,<br>sharpen, rotate, flip, annotations,<br>zoom in/out, magnifier | Grayscale, invert, emboss, brightness,<br>contrast, gamma, sharpen, median,<br>despeckle, hue, saturation, equalize<br>flip, mirror, masking, rotate,<br>annotation, cephalometric tracing,<br>implant simulations |
| Technology | AI-based algorithms for the<br>detection of natural dental<br>structures and structures added<br>through past restorative treatment | AI-based algorithms for detection of<br>various anatomical landmarks |
#### 7. PERFORMANCE DATA
### Biocompatibility Testing
There are no direct or indirect patient-contacting components of the subject device. Therefore, patient contact information is not needed for this device.
### Electrical safety and electromagnetic compatibility (EMC)
Not applicable. The subject device is a software-only device. It contains no electric components, generates no electrical emissions, and uses no electrical energy of any type.
## Software Verification and Validation Testing
Software verification and validation testing were conducted and documentation was provided as recommended by FDA's Guidance for Industry and FDA Staff, "Guidance for the Content of
{6}------------------------------------------------
Premarket Submissions for Software Contained in Medical Devices." The software for this device was considered as a Moderate Level of Concern a malfunction of, or a latent design flaw in, the Software Device lead to an erroneous diagnosis or a delay in delivery of appropriate medical care that would likely lead to Minor Injury. Verification of the software was conducted to ensure that the product works as designed. Validation was conducted to check the design and performance of the product.
## Bench Testing
Denti. AI completed the standalone study according to the protocol to demonstrate the safety and effectiveness of the Denti.AI Auto-Chart device for its indications for use.
### Dataset
The testing dataset used in the study consisted of the 336 images (1 image per patient) taken from the multiple dental clinics across the US. The patient population was roughly uniformly distributed by age and gender. The following distribution of imaging modalities and sensor manufacturers were present in the testing dataset:
Image distribution by Modality
Image /page/6/Figure/7 description: The image is a pie chart that shows the image distribution by modality. The three modalities are periapical, bitewing, and pan. Periapical is 35.4%, bitewing is 45.5%, and pan is 19.0%.
{7}------------------------------------------------
Image /page/7/Figure/2 description: This image is a pie chart showing the market share of different dental imaging companies. Dexis has the largest market share at 31.3%, followed by Gendex at 19.0% and Kavo at 12.2%. Air Techniques has 9.5%, Carestream has 8.0%, and Duerr has 7.7%. Vatech has 4.5%, while Acteon and Sirona each have 2.1%. Soredex and Palodex each have 1.8%.
Image distribution by Sensor Manufacturer
### Reference Standard
The ground truth annotations (GT) were used as the reference standard when measuring the device performance. The GT was established with the help of two experienced dental hygienists with an experienced dentist reviewing cases of disagreement.
### Study Results
The primary tests and the metrics are listed in the table below:
- "Sensitivity (teeth in the field of view)" of Teeth Detection shows the percentage of ● actual positive teeth (teeth annotated in the GT) in the image field of view that are successfully found by the device
- "PPV" of Teeth Detection shows the percentage of teeth found by the device that are actual positive teeth
- "Overall classification accuracy" of Teeth Numbering shows the percentage of detected teeth that are correctly numbered by the device according to the standard dental notation
- "Sensitivity averaged across all restoration types" of Restorative Findings Identification shows the percentage of actual positive teeth (teeth showing the restorative finding in the GT with the matching restoration type) that are successfully classified by the device as positive
- . "Specificity averaged across all restoration types" of Restorative Findings Identification shows the percentage of actual negative teeth (teeth that do NOT show the restorative finding in the GT with the matching restoration type) that are successfully classified by the device as negative
- "Classification accuracy averaged across all findings" of Binding Dental Findings to ● Teeth shows the percentage of findings that are associated with the correct tooth
{8}------------------------------------------------
- . "Classification accuracy averaged across all types" of Classifying Filling By Type shows the percentage of teeth with detected fillings that are correctly classified by the filling type
- . " Classification accuracy averaged across all surfaces" of Classifying Filling By Surface shows the percentage of teeth with detected fillings that are correctly classified by affected surfaces
- . "Classification accuracy" of Classifying Crowns by Type shows the percentage of teeth with detected crowns that are correctly classified by the crown type
- . "Manual charting reduction rate" of the Summary Performance shows the percentage of reduction in the number of manual operations when pre-filling the charting data with Denti.AI Auto-Chart compared to entering all the charting records manually
| Test ID | Test Name | Metric | Value | 95% Confidence Interval |
|---------|----------------------------------------|---------------------------------------------------------|-------|-------------------------|
| 1 | Teeth Detection | Sensitivity (teeth in the field of<br>view) | 97.4% | (96.6%, 98.2%) |
| | | PPV | 99.6% | (99.3%, 99.9%) |
| 2 | Teeth Numbering | Overall classification accuracy | 85.9% | (82.6%, 88.9%) |
| 3 | Restorative Findings<br>Identification | Sensitivity averaged across all<br>restoration types | 88.5% | (86.1%, 90.6%) |
| | | Specificity averaged across all<br>restoration types | 98.3% | (97.8%, 98.7%) |
| 4 | Binding Dental Findings to<br>Teeth | Classification accuracy averaged<br>across all findings | 98.3% | (97.5%, 99.0%) |
| 5 | Classifying Filling By<br>Type | Classification accuracy averaged<br>across all types | 98.0% | (96.9%, 98.9%) |
| 6 | Classifying Filling By<br>Surface | Classification accuracy averaged<br>across all surfaces | 88.9% | (87.0%, 90.7%) |
| 7 | Classifying Crowns by<br>Type | Classification accuracy | 94.8% | (92.2%, 97.1%) |
| 8 | Summary Performance | Manual charting reduction rate | 71.2% | (68.2%, 74.1%) |
### Conclusions
All conducted tests produced results that exceeded predefined acceptance criteria. The Summary Performance "Manual charting reduction rate" metric shows that the number of manual operations is reduced by over 70% when using Denti.AI Auto-Chart for initial dental chart pre-filling compared to the fully manual entry of the same dental charting information.
Stratified analysis by patient gender and age demonstrated that there is no significant difference in any of the reported endpoints. Stratified analysis by sensors demonstrated the overall high level of generalizability: no sensor is a clear outlier. Stratified analysis by modality demonstrated differences in two main endpoints:
- Classification accuracy of teeth numbering is higher on extraoral images. This difference can be explained by the fact that extraoral images show a full mouth picture, whereas intraoral images show only a segment of the jaw, sometimes as few as 3-4 teeth. Numbering teeth on intraoral images is naturally more challenging than on panoramic images
{9}------------------------------------------------
- . Restorative Findings Identification sensitivity metric is higher on intraoral images. The main difference is in detecting crowns and fillings, whereas the performance in detecting implants and endodontic treatments is close for each modality. The difference can be explained by the fact that intraoral images have a much higher spatial resolution compared to panoramic images While having some natural tradeoffs in terms of producing charting data, both modalities demonstrated close estimates of Summary Performance metrics ("Manual charting reduction rate")
# Animal Testing
Not applicable. Animal studies are not necessary to establish the substantial equivalence of this device.
# Clinical Data
Not applicable. Clinical studies are not necessary to establish the substantial equivalence of this device.
#### CONCLUSION 8.
The predicate device and subject device have the same intended use, as they are both intended for use to create dental charts to track patient information and treatments. Both devices are intended for use by trained dental practitioners who are responsible for making the final clinical decisions. Although there are technical differences, as discussed above, these differences in technological characteristics do not raise different questions of safety and effectiveness. The predefined Acceptance Criteria established for the stand-alone study are based on the current state of dental practice and are appropriate to demonstrate that Auto-Chart performs in accordance with specifications and will meet user needs and intended uses.
Based on the detailed comparison between the predicate devices and the subject devices, the software verification testing and performance testing, the Denti.AI Auto-Chart can be found substantially equivalent to the predicate device.
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.