K220464 · Tigon Medical · MBI · Mar 22, 2023 · Orthopedic
Device Facts
Record ID
K220464
Device Name
Tigon Medical Gryphon Anchor Line
Applicant
Tigon Medical
Product Code
MBI · Orthopedic
Decision Date
Mar 22, 2023
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 888.3040
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The Tigon Medical Gryphon Anchor Line is made up of four families of soft tissue fixation devices: Tomahawk Anchor, Dual Anchor, Eye-Deal Anchor, and Tenodesis Anchors. The entirety of the gryphon anchor line is intended for use for the reattachment of soft tissue to bone for the following indications: Shoulder: Capsular stabilization (Bankart repair, Anterior shoulder instability, SLAP lesion repairs, Capsular shift or capsulolabral reconstructions), Acromioclavicular separation repairs, Deltoid repairs, Rotator cuff repairs, Bicep tenodesis. Elbow, Wrist, and Hand: Biceps tendon reattachment, Ulnar or radial collateral ligament reconstruction, Lateral epicondylitis repair; Knee: Extra-capsular repairs (Medial collateral ligament, Lateral collateral ligament, Posterior oblique ligament), Patellar realignment and tendon repairs (Vastus medialis obliquus advancement), Iliotibial band tenodesis; Foot and Ankle: Hallux valgus repairs, Medial or Lateral instability repairs/reconstructions, Achilles tendon repairs/ reconstructions, Midfoot reconstructions, Metatarsal ligament/tendon repairs/reconstructions, Bunionectomy In addition to these indications, the Tenodesis Anchors, a sub family of the gryphon anchor line will also be indicated for: Foot and Ankle: Flexor hallucis longus for Achilles tendon reconstructions, tendon transfers in the foot and Ankle Knee: ACL Repair Hand/Wrist: Carpometacarpal joint arthroplasty, carpal ligament reconstructions and repairs, tendon transfer in hand/wrist
Device Story
Gryphon Anchor Line comprises four soft tissue fixation anchor families (Tomahawk, Dual, Eye-Deal, Tenodesis); used for reattaching soft tissue to bone. Anchors are inserted into pre-drilled pilot holes using stainless steel inserters; fixation achieved via interference or screw-in mechanisms. Devices are used in orthopedic surgical settings by physicians. Output is the mechanical fixation of soft tissue to bone, facilitating healing and stabilization. Benefits include restored joint stability and tendon function. Anchors are provided sterile; some inserters are reusable and sterilized on-site.
Clinical Evidence
Bench testing only. Testing included axial pullout strength (per ASTM F543), cyclic loading fatigue testing, and insertion performance. Biocompatibility evaluated per ISO 10993-1. Sterilization, endotoxin, and shelf-life testing performed.
Technological Characteristics
Materials: VESTAKEEP i4R PEEK (ASTM F2026) or Ti6Al4V ELI (ASTM F136). Dimensions: 3.75mm x 6mm to 10.5mm x 23mm. Fixation: Interference or screw-in. Inserters: Stainless steel (ASTM F899). Sterilization: Sterile (SAL 10^-6).
Indications for Use
Indicated for reattachment of soft tissue to bone in shoulder, elbow, wrist, hand, knee, and foot/ankle procedures. Specific indications include capsular stabilization, rotator cuff repair, bicep tenodesis, ligament reconstruction, tendon repair, and bunionectomy. Tenodesis sub-family additionally indicated for ACL repair, FHL for Achilles reconstruction, and CMC joint arthroplasty.
Regulatory Classification
Identification
A smooth or threaded metallic bone fixation fastener is a device intended to be implanted that consists of a stiff wire segment or rod made of alloys, such as cobalt-chromium-molybdenum and stainless steel, and that may be smooth on the outside, fully or partially threaded, straight or U-shaped; and may be either blunt pointed, sharp pointed, or have a formed, slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a guide pin for insertion of other implants, or it may be implanted through the skin so that a pulling force (traction) may be applied to the skeletal system.
{0}------------------------------------------------
March 22, 2023
Image /page/0/Picture/1 description: The image shows the logos of the Department of Health & Human Services and the Food and Drug Administration (FDA). The Department of Health & Human Services logo is on the left, and the FDA logo is on the right. The FDA logo includes the letters "FDA" in a blue square, followed by the words "U.S. FOOD & DRUG ADMINISTRATION" in blue text. The logos are simple and professional, and they are likely used to identify the organizations on official documents and websites.
Tigon Medical Jeremy Clark President 303 Najoles Rd Millersville, Maryland 21108
Re: K220464
Trade/Device Name: Tomahawk Anchors, Dual Anchors, Eye-Deal Anchors, Tenodesis Anchors Regulation Number: 21 CFR 888.3040 Regulation Name: Smooth Or Threaded Metallic Bone Fixation Fastener Regulatory Class: Class II Product Code: MBI Dated: February 24, 2023 Received: February 28, 2023
Dear Mr. Clark:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database located at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803) for
{1}------------------------------------------------
devices or postmarketing safety reporting (21 CFR 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reportingcombination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-device-safety/medical-device-reportingmdr-how-report-medical-device-problems.
For comprehensive regulatory information about mediation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medicaldevices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-device-advice-comprehensive-regulatoryassistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).
Sincerely.
# Sara S. Thompson -S
For
Laurence D. Coyne, Ph.D. Director DHT6C: Division of Restorative, Repair and Trauma Devices OHT6: Office of Orthopedic Devices Office of Product Evaluation and Ouality Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
### Indications for Use
510(k) Number (if known) K220464
Device Name Tigon Medical Gryphon Anchor Line
#### Indications for Use (Describe)
The Tigon Medical Gryphon Anchor Line is made up of four families of soft tissue fixation devices: Tomahawk Anchor, Dual Anchor, Eye-Deal Anchor, and Tenodesis Anchors. The gryphon anchor line is intended for use for the reattachment of soft tissue to bone for the following indications:
Shoulder: Capsular stabilization (Bankart repar, Anterior shoulder instability, SLAP lesion repairs, Capsular shift or capsulolabral reconstructions), Acromioclavicular separation repairs, Rotator cuff repairs, Bicep tenodesis.
Elbow, Wrist, and Hand: Biceps tendon reattachment, Ulnar or radial collateral ligament reconstruction, Lateral epicondylitis repair;
Knee: Extra-capsular repairs (Medial collateral ligament, Lateral ligament, Posterior oblique ligament), Patellar realignment and tendon repairs (Vastus medialis obliquus advancement), Iliotibial band tenodesis;
Foot and Ankle: Hallux valgus repairs, Medial or Lateral instability repairs/reconstructions, Achilles tendon repairs/ reconstructions, Midfoot reconstructions, Metatarsal ligament/tendon repairs/reconstructions, Bunionectomy
In addition to these indications, the Tenodes, a sub family of the gryphon anchor line will also be indicated for:
Foot and Ankle: Flexor hallucis longus for Achilles tendon reconstructions, tendon transfers in the foot and Ankle
Knee: ACL Repair
Hand Wrist: Carpometacarpal joint arthroplasty, carpal ligament reconstructions and repairs, tendon transfer in hand/wrist
| Type of Use (Select one or both, as applicable) | |
|--------------------------------------------------------------------------------|-------------------------------------------------------------------------------|
| <div> <span>☑</span> Prescription Use (Part 21 CFR 801 Subpart D) </div> | <div> <span>☐</span> Over-The-Counter Use (21 CFR 801 Subpart C) </div> |
#### CONTINUE ON A SEPARATE PAGE IF NEEDED.
{3}------------------------------------------------
This section applies only to requirements of the Paperwork Reduction Act of 1995.
#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
{4}------------------------------------------------
Image /page/4/Picture/2 description: The image shows the logo for Tigon Medical. The logo features a stylized tiger eye on the left, with the words "TIGON MEDICAL" in bold, sans-serif font to the right of the eye. The eye is black and white with an orange iris.
### Submitter Information
| Applicant: | Tigon Medical |
|---------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Submission Number: | K220464 |
| Contact Person: | Jeremy Clark<br>Management Representative<br>Tigon Medical<br>303 Najoles Rd.<br>Millersville, MD 21108<br>(410) 544-2833 |
| Date Prepared: | 03/22/2023 |
| Name of Device: | Tigon Medical Gryphon Anchor Line |
| Common Name: | Fastener, Fixation, Nondegradable, soft tissue |
| Classification Name | 21 CFR 888.3040: Smooth or threaded metallic bone fixation<br>fastener. |
| Product Code/Panel: | MBI |
| Predicate Devices: | Tigon Medical Tissue Anchors (K182507)<br>Reference: Tigon Medical Button System (K211049)<br>Reference: Arthrex Tenodesis Family (K051726)<br>Reference: Smith and Nephew Bioraptor (K151105) |
Page | 1 of 10
{5}------------------------------------------------
Image /page/5/Picture/2 description: The image contains the logo for Tigon Medical. The logo features a stylized tiger eye on the left, with the words "TIGON MEDICAL" in bold, sans-serif font to the right of the eye. The eye is primarily black with an orange iris.
#### Intended Use:
The Tigon Medical Gryphon Anchor Line is made up of four families of soft tissue fixation devices: Tomahawk Anchor, Dual Anchor, Eye-Deal Anchor, and Tenodesis Anchors. The entirety of the gryphon anchor line is intended for use for the reattachment of soft tissue to bone for the following indications:
Shoulder: Capsular stabilization (Bankart repair, Anterior shoulder instability, SLAP lesion repairs, Capsular shift or capsulolabral reconstructions), Acromioclavicular separation repairs, Deltoid repairs, Rotator cuff repairs, Bicep tenodesis.
Elbow, Wrist, and Hand: Biceps tendon reattachment, Ulnar or radial collateral ligament reconstruction, Lateral epicondylitis repair;
Knee: Extra-capsular repairs (Medial collateral ligament, Lateral collateral ligament, Posterior oblique ligament), Patellar realignment and tendon repairs (Vastus medialis obliquus advancement), Iliotibial band tenodesis;
Foot and Ankle: Hallux valgus repairs, Medial or Lateral instability repairs/reconstructions, Achilles tendon repairs/ reconstructions, Midfoot reconstructions, Metatarsal ligament/tendon repairs/reconstructions, Bunionectomy
In addition to these indications, the Tenodesis Anchors, a sub family of the gryphon anchor line will also be indicated for:
Foot and Ankle: Flexor hallucis longus for Achilles tendon reconstructions, tendon transfers in the foot and Ankle
Knee: ACL Repair
Hand/Wrist: Carpometacarpal joint arthroplasty, carpal ligament reconstructions and repairs, tendon transfer in hand/wrist
{6}------------------------------------------------
Image /page/6/Picture/2 description: The image shows the logo for Tigon Medical. The logo features a stylized tiger eye on the left, with the words "TIGON MEDICAL" in bold, black letters to the right of the eye. The eye is orange and black, and the text is in a sans-serif font.
#### Device Description Summary:
The Tigon Medical Gryphon Anchor Line consists of four sub-families of suture anchors: Tomahawk anchors, Dual anchors, Tenodesis anchors, and Eye-Deal anchors. It consists of a range of anchors sizes between 3.75 mm diameter and 6 mm length to 10.5 mm diameter and 23 mm length. The Tomahawk Anchors, Dual Anchors, and Tenodesis anchors are made from VESTAKEEP® i4R PEEK per ASTM F2026 while the Eye-Deal Anchors are made from Ti6Al4V ELI per ASTM F136.
The anchors are available with many configurations of sutures and suture tapes or without suture. All the anchors in this system may be loaded with a combination of USP #2 suture cables and/or tape equivalent while the Dual Anchors and Tenodesis anchors may be loaded with a combination of USP 2 and USP 5 suture cables and/or tape equivalent.
All anchors are inserted with stainless steel inserters per ASTM F899. The shafts that are used with the Tomahawk anchors may be reprocessed and will be available sterile packed and attached to the anchor and suture.
#### Substantial Equivalence Summary:
The Tigon Medical Gryphon anchor line is made of four sub-families: Tomahawk Anchors, Dual Anchors, Eye-Deal Anchors, and Tenodesis Anchors. All four sub-families are substantially equivalent to the predicate devices as the features and intended use are the same. The indications for use differ between the Tenodesis anchors and the rest of the product family made up by the other Gryphon anchor sub-families. Those additional indications for use are found in the reference device: K051726 (Arthrex Tenodesis Family). Anchor fixation has been shown to be a biomechanically sound method of soft tissue to bone fixation. Mechanical testing has been done, including cyclical loading and tensile strength which demonstrated the proposed products met the acceptance criteria for the proposed indications.
{7}------------------------------------------------
Image /page/7/Picture/2 description: The image shows the logo for Tigon Medical. The logo features a stylized tiger eye on the left, with the words "TIGON MEDICAL" in bold, sans-serif font to the right of the eye. The eye is orange with black stripes, and the text is black.
| Characteristics | Tigon Medical Gryphon<br>Anchor Line | Tigon Medical Tissue<br>Anchors | Substantial Equivalence |
|------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Product Codes | MBI | MBI | Yes |
| 510(k) Number | K220464 | K121018 | Yes |
| Indications | The Tigon Medical<br>Gryphon Anchor Line is<br>made up of four families<br>of soft tissue fixation<br>devices: Tomahawk<br>Anchor, Dual Anchor,<br>Eye-Deal Anchor, and<br>Tenodesis Anchors. The<br>entirety of the gryphon<br>anchor line is intended<br>for use for the<br>reattachment of soft<br>tissue to bone for the<br>following indications:<br>Shoulder: Capsular<br>stabilization (Bankart<br>repair, Anterior shoulder<br>instability, SLAP lesion<br>repairs, Capsular shift or<br>capsulolabral<br>reconstructions),<br>Acromioclavicular<br>separation repairs,<br>Deltoid repairs, Rotator<br>cuff repairs, Bicep<br>tenodesis. | The Tigon Medical Tissue<br>Anchor System is intended<br>for use for the<br>reattachment of soft tissue<br>to bone for the following<br>indications:<br>Shoulder: Capsular<br>stabilization (Bankart repair,<br>Anterior shoulder instability,<br>SLAP lesion repairs,<br>Capsular shift or<br>capsulolabral<br>reconstructions),<br>Acromnioclavicular<br>separation repairs, Deltoid<br>repairs, Rotator cuff repairs,<br>Bicep<br>tenodesis;<br>Elbow, Wrist, and Hand:<br>Biceps tendon<br>reattachment, Ulnar or<br>radial collateral ligament<br>reconstruction, Lateral<br>epicondylitis repair;<br>Knee: Extra-capsular repairs<br>(Medial collateral ligament,<br>Lateral collateral ligament,<br>Posterior oblique ligament), | Yes, when also considering<br>the referenced devices.<br>The Arthrex tenodesis<br>family (K051726) have the<br>same added indications as<br>the tenodesis anchors, a<br>sub family in the Tigon<br>Medical Gryphon Anchor<br>line.<br>(In addition to these<br>indications, the Tenodesis<br>Anchors, a sub family of<br>the gryphon anchor line<br>will also be indicated for:<br>Foot and Ankle: Flexor<br>hallucis longus for Achilles<br>tendon reconstructions,<br>tendon transfers in the foot<br>and Ankle<br>Knee: ACL Repair<br>Hand/Wrist:<br>Carpometacarpal joint<br>arthroplasty, carpal |
| Characteristics | Tigon Medical Gryphon<br>Anchor Line | Tigon Medical Tissue<br>Anchors | Substantial Equivalence |
| | Elbow, Wrist, and Hand:<br>Biceps tendon<br>reattachment, Ulnar or<br>radial collateral ligament<br>reconstruction, Lateral<br>epicondylitis repair; | Patellar realignment and<br>tendon repairs (Vastus<br>medialis obliquous<br>advancement), Illiotibial<br>band tenodesis; | ligament reconstructions<br>and repairs, tendon<br>transfer in hand/wrist) |
| | Knee: Extra-capsular<br>repairs (Medial collateral<br>ligament, Lateral<br>collateral ligament,<br>Posterior oblique<br>ligament), Patellar<br>realignment and tendon<br>repairs (Vastus medialis<br>obliquus advancement),<br>Iliotibial band tenodesis; | Foot and Ankle: Hallux<br>valgus repairs, Medial or<br>Lateral instability<br>repairs/reconstructions,<br>Achilles tendon repairs/<br>reconstructions, Midfoot<br>reconstructions, Metatarsal<br>ligament/tendon<br>repairs/reconstructions,<br>Bunionectomy | |
| | Foot and Ankle: Hallux<br>valgus repairs, Medial or<br>Lateral instability<br>repairs/reconstructions,<br>Achilles tendon repairs/<br>reconstructions, Midfoot<br>reconstructions,<br>Metatarsal<br>ligament/tendon | | |
| Characteristics | Tigon Medical Gryphon<br>Anchor Line | Tigon Medical Tissue<br>Anchors | Substantial Equivalence |
| | repairs/reconstructions,<br>Bunionectomy | | |
| | In addition to these<br>indications, the Tenodesis<br>Anchors, a sub family of<br>the gryphon anchor line<br>will also be indicated for: | | |
| | Foot and Ankle: Flexor<br>hallucis longus for Achilles<br>tendon reconstructions,<br>tendon transfers in the<br>foot and Ankle | | |
| | Knee: ACL Repair | | |
| | Hand/Wrist:<br>Carpometacarpal joint<br>arthroplasty, carpal<br>ligament reconstructions<br>and repairs, tendon<br>transfer in hand/wrist | | |
| Sizes | The Tigon Medical<br>Gryphon Anchor Line is<br>made up of a range of<br>sizes. | The Tigon Medical Tissue<br>anchors is made up of a<br>range of sizes. | Yes, when also considering<br>the referenced devices.<br>The tenodesis anchors<br>have a larger size range |
| Characteristics | Tigon Medical Gryphon<br>Anchor Line | Tigon Medical Tissue<br>Anchors | Substantial Equivalence |
| | | | than the Tigon Medical<br>Tissue Anchors, but this<br>range is identical to the<br>range of the referenced<br>Arthrex Tenodesis Family<br>anchors (K051726) |
| Mechanical<br>Strength | The worst case implant in<br>the Tigon Medical<br>Gryphon Anchor Line has<br>a mechanical strength of<br>262.3 N | The worst-case implant in<br>the Tigon Medical Tissue<br>Anchor line has a<br>mechanical strength of<br>143.6 N | Yes |
| Fatigue Testing | Up to 500 cycles were<br>done from unloaded<br>(5N) to loaded(60N)<br>condition until failure. | Up to 500 cycles were<br>done from unloaded (5N)<br>to loaded(60N) condition<br>until failure. | Yes |
| Material | PEEK per ASTM F2026 or<br>Ti-6AL-4V ELI Titanium per<br>ASTM F-136 | PEEK Per ASTM F2026 | Yes<br>For Titanium see reference<br>device Tigon Medical<br>Button System made from<br>TI6Al4V ELI Per ASTM F136.<br>(K211049) |
| Method of<br>fixation | Interference or screw in | Push in, or screw in | Yes, when also considering<br>the referenced devices.<br>The tenodesis anchors<br>have an identical method<br>of fixation (interference) as<br>the referenced Arthrex |
| Characteristics | Tigon Medical Gryphon<br>Anchor Line | Tigon Medical Tissue<br>Anchors | Substantial Equivalence |
| | | | Tenodesis Family anchors<br>(K051726) |
| Inserter | Multi-piece (2 or 3)<br>reusable inserter.<br>Anchors may come<br>preloaded with suture on<br>an inserter shaft or be<br>loaded on an inserter at<br>time of surgery. | Multi-piece (2) reusable<br>inserter.<br>Anchors may come<br>preloaded with suture and will<br>be loaded on the inserter<br>at the time of surgery | Yes |
| Drills/Awls | Anchors will be inserted<br>into pilot holes<br>appropriate for their size | Anchors are inserted into<br>pilot holes appropriate to<br>their size. | Yes |
| Cannulas | Drill Guide | Drill Guide | Yes |
| Supplied | All Implants: Sterile to<br>assure an SAL of 10-6<br>One inserter type: Sterile<br>to assure a Sterile to<br>assure an SAL of 10-6<br>All other inserters: Non<br>Sterile, to be sterilized on<br>site in tray | All Implants: Sterile to assure<br>an SAL of 10-6<br>All other inserters: Non<br>Sterile, to be sterilized on<br>site in tray | Yes |
{8}------------------------------------------------
Image /page/8/Picture/2 description: The image contains the logo for Tigon Medical. The logo features a stylized tiger eye on the left, with the words "TIGON MEDICAL" in bold, sans-serif font to the right of the eye. The eye is orange and black, while the text is black.
{9}------------------------------------------------
Image /page/9/Picture/2 description: The image shows the logo for Tigon Medical. The logo features a stylized tiger eye on the left, with the words "TIGON MEDICAL" in bold, sans-serif font to the right of the eye. The eye is orange and black, and the text is black.
{10}------------------------------------------------
Image /page/10/Picture/2 description: The image contains the logo for Tigon Medical. The logo features a stylized tiger eye on the left, with the words "TIGON MEDICAL" in bold, sans-serif font to the right of the eye. The word "TIGON" is in a larger font size than the word "MEDICAL."
{11}------------------------------------------------
Image /page/11/Picture/2 description: The image contains the logo for Tigon Medical. The logo features a stylized tiger eye on the left, with the words "TIGON MEDICAL" in bold, sans-serif font to the right of the eye. The eye is primarily black with an orange iris.
{12}------------------------------------------------
Image /page/12/Picture/2 description: The image shows the logo for Tigon Medical. The logo features a stylized tiger eye on the left, with the words "TIGON MEDICAL" in bold, sans-serif font to the right of the eye. The eye is black with an orange iris.
#### Non-Clinical Testing Summary:
Tigon Medical substantiates that the product is as safe, as effective, and performs as well as or better than the legally marketed predicate.
Tests performed:
Axial Pullout Strength: The device was found to be substantially equivalent to the predicate for maximum pullout strength per ASTM F543.
Fatigue Testing: The device was found to be substantially equivalent to the predicate for cyclic loading fatigue testing.
Insertion Performance Testing: The device was found to be substantially equivalent to the predicate product.
Sterilization Validation activities including EO Residual Testing, Sterility Testing, and Bioburden Testing.
Endotoxin testing has been conducted and will be continuously monitored on a lot-bylot basis.
Accelerated Shelf-Life Testing and Packaging Performance/integrity testing has been conducted and real-time shelf-life testing is on-going.
#### Biocompatibility Summary:
The device in its final finished form has been evaluated for biocompatibility according to ISO 10993-1.
{13}------------------------------------------------
Image /page/13/Picture/2 description: The image shows the logo for Tigon Medical. The logo features a stylized tiger eye on the left, with the words "TIGON MEDICAL" in bold, sans-serif font to the right of the eye. The eye is orange and black, and the text is black.
#### Device Comparison Discussion:
Substantial equivalence between the Tigon Medical Gryphon Anchor Line and the Tigon Medical Tissue Anchors can be demonstrated according to the FDA's Guidelines for Substantial Equivalence Decision Making Process, for at least the following reasons:
- . The Tigon Medical Gryphon Anchor Line is compared to the Tigon Medical Tissue Anchors
- . The Tigon Medical Gryphon Anchor Line has equivalent intended use and indications as the Tigon Medical Tissue Anchor
- . Major technological characteristics are substantially equivalent between the Tigon Medical Gryphon Anchor Line and the Tigon Medical Tissue Anchor
- including, but not limited to: ●
- Substantially equivalent materials* o
- Substantially equivalent size range** O
- O Substantially equivalent method of fixation
- Substantially equivalent mechanical strength O
*The Eye-Deal anchor is titanium which is identical to that of the reference device: Tigon Medical Button System (K211049)
**The Tenodesis Anchors exceed the size range of the Tigon Medical Tissue Anchor, but is substantially equivalent to that of the Arthrex Tenodesis Family anchors (K051726). The indications for use of the Tenodesis anchors match that of the Arthrex Tenodesis Family anchors (K051726)
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.