← Product Code [KPS](/productcode/KPS) · K213731

# EFAI CARDIOSUITE SPECT Myocardial Perfusion Agile Workflows (K213731)

_Ever Fortune.Ai, Co., Ltd. · KPS · May 31, 2022 · Radiology · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K213731

## Device Facts

- **Applicant:** Ever Fortune.Ai, Co., Ltd.
- **Product Code:** [KPS](/productcode/KPS.md)
- **Decision Date:** May 31, 2022
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 892.1200
- **Device Class:** Class 2
- **Review Panel:** Radiology
- **Attributes:** Software as a Medical Device

## Indications for Use

EFAI CARDIOSUITE SPECT MYOCARDIAL PERFUSION AGILE WORKFLOWS is an image processing software that provides analysis on DICOM images acquired from GE Medical Systems Nuclear Quantitative Perfusion SPECT software to support appropriately trained healthcare professionals in the evaluation and assessment of myocardial perfusions. It provides the following functionality: - Segmentation of the Bull's Eye images from the original DICOM - Analysis of the Bull's Eye images to help assess perfusion - Custom settings to generate text reports The results of this processing may be used to aid in evaluating and assessing myocardial perfusions. The system is an adjunct tool for GE Medical Systems Nuclear Quantitative Perfusion SPECT software.

## Device Story

EFAI CARDIOSUITE SPECT Myocardial Perfusion Agile Workflows is a web-based image processing software; operates as an adjunct to GE Medical Systems Nuclear Quantitative Perfusion SPECT software. Input: DICOM Bull's Eye images from GE workstations. Processing: segments Bull's Eye images; performs quantitative analysis of 17 myocardial segments under rest and stress conditions using a color-coded threshold scale (red=normal, blue=severe perfusion). Output: quantitative evaluation results; customizable text reports. Used by nuclear radiologists in clinical settings to aid in assessing myocardial perfusion and documenting patient conditions. Benefits: improves workflow efficiency by automating image review, quantification, and report generation.

## Clinical Evidence

No clinical data. Substantial equivalence demonstrated via non-clinical performance testing, including software verification and validation per IEC 62304 and usability engineering per IEC 62366-1/2.

## Technological Characteristics

Software-as-a-Medical-Device (SaMD); web-based interface; processes DICOM SPECT images; 17-segment myocardial model; color-threshold-based quantitative analysis; generates HTML/PDF/Word reports. Standards: IEC 62304 (software lifecycle), IEC 62366-1/2 (usability).

## Regulatory Identification

An emission computed tomography system is a device intended to detect the location and distribution of gamma ray- and positron-emitting radionuclides in the body and produce cross-sectional images through computer reconstruction of the data. This generic type of device may include signal analysis and display equipment, patient and equipment supports, radionuclide anatomical markers, component parts, and accessories.

## Predicate Devices

- AutoQUANT® Plus ([K040326](/device/K040326.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

Image /page/0/Picture/0 description: The image contains the logo of the U.S. Food and Drug Administration (FDA). The logo consists of two parts: the Department of Health & Human Services logo on the left and the FDA logo on the right. The FDA logo is in blue and includes the letters "FDA" followed by the words "U.S. FOOD & DRUG ADMINISTRATION" in a stacked format.

Ever Fortune.AI Co., Ltd. % Cheng Ming-Fong Chairman 8F., No. 573, Sec. 2, Taiwan Blvd., West Dist. Taichung City, 403020 TAIWAN

### Re: K213731

Trade/Device Name: EFAI CARDIOSUITE SPECT Myocardial Perfusion Agile Workflows Regulation Number: 21 CFR 892.1200 Regulation Name: Emission computed tomography system Regulatory Class: Class II Product Code: KPS, LLZ Dated: March 18, 2022 Received: April 4, 2022

Dear Cheng Ming-Fong:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database located at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803) for

{1}------------------------------------------------

devices or postmarketing safety reporting (21 CFR 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reportingcombination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-device-safety/medical-device-reportingmdr-how-report-medical-device-problems.

For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medicaldevices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-device-advice-comprehensive-regulatoryassistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).

Sincerely.

for

Michael D. O'Hara, Ph.D. Deputy Director DHT 8C: Division of Radiological Imaging and Radiation Therapy Devices OHT8: Office of Radiological Health Office of Product Evaluation and Quality Center for Devices and Radiological Health

Enclosure

{2}------------------------------------------------

### DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration

### Indications for Use

510(k) Number (if known) K213731

Device Name

### EFAI CARDIOSUITE SPECT MYOCARDIAL PERFUSION AGILE WORKFLOWS

Indications for Use (Describe)

EFAI CARDIOSUITE SPECT MYOCARDIAL PERFUSION AGILE WORKFLOWS is an image processing software that

provides analysis on DICOM images acquired from GE Medical Systems Nuclear Quantitative Perfusion SPECT software to

support appropriately trained healthcare professionals in the evaluation and assessment of myocardial perfusions.

It provides the following functionality:

- Segmentation of the Bull's Eye images from the original DICOM
- Analysis of the Bull's Eye images to help assess perfusion
- Custom settings to generate text reports

The results of this processing may be used to aid in evaluating and assessing myocardial perfusions.

The system is an adjunct tool for GE Medical Systems Nuclear Quantitative Perfusion SPECT software.

| Type of Use ( <i>Select one or both, as applicable</i> )                                                                                    |                                                  |                                             |
|---------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------|---------------------------------------------|
| <table><tr><td>[X] Prescription Use (Part 21 CFR 801 Subpart D)</td><td>   Over-The-Counter Use (21 CFR 801 Subpart C)   </td></tr></table> | [X] Prescription Use (Part 21 CFR 801 Subpart D) | Over-The-Counter Use (21 CFR 801 Subpart C) |
| [X] Prescription Use (Part 21 CFR 801 Subpart D)                                                                                            | Over-The-Counter Use (21 CFR 801 Subpart C)      |                                             |

CONTINUE ON A SEPARATE PAGE IF NEEDED.

This section applies only to requirements of the Paperwork Reduction Act of 1995.

***DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.***

### The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:

Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov

IlAn agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."

{3}------------------------------------------------

Image /page/3/Picture/0 description: The image contains a logo for a company called "EVER FORTUNE.AI". The logo consists of a stylized human figure with a circular head and outstretched arms, colored in a gradient of light blue and green. Above the figure's head is a green sphere with a network pattern on it. To the right of the figure is the company name, "EVER FORTUNE.AI", also in light blue and green.

# 510(k) Summary

## K213731

The following information is provided in accordance with 21 CFR 807.92 for the Premarket 510(k) Summary:

#### I. Submitter

| Company:                  | EverFortune.AI Co., Ltd.                                   |  |
|---------------------------|------------------------------------------------------------|--|
|                           | 8 F., No. 573, Sec. 2, Taiwan Blvd.,                       |  |
|                           | West Dist., Taichung City 403020, Taiwan                   |  |
|                           | Phone: (886)-4-2322-6363                                   |  |
|                           | Fax: (886)-4-2322-9797                                     |  |
|                           | ra99@everfortuneai.com.tw                                  |  |
| Correspondence Person:    | Ming-Fong, Chen (Chairman)                                 |  |
|                           | ra99@everfortuneai.com.tw                                  |  |
| Applicant Person:         | Jenna Hsiao (RA)                                           |  |
|                           | ra05@everfortuneai.com.tw                                  |  |
| Date Prepared:            | May 18th, 2022                                             |  |
| II.<br>Name of the Device |                                                            |  |
| Name of Device:           | EFAI CARDIOSUITE SPECT Myocardial Perfusion Agile Workflow |  |
| Common Name:              | EFAI SPECT Workflows                                       |  |
| Classification Name:      | Emission Computed Tomography System                        |  |
| Review Panel              | Radiology                                                  |  |
| Proposed Classification:  | Device Class: II                                           |  |

#### Predicate Device III.

AutoQUANT® Plus manufactured by ADAC LABORATORIES under K040326 This predicate has not been subject to a design-related recall. No reference devices were used in this submission. Predicate Classification: Class II / KPS / 21 CFR §892.1200

Product Code: KPS, LLZ

Regulation Number: 21 CFR §892.1200

{4}------------------------------------------------

Image /page/4/Picture/0 description: The image contains a logo for a company called EVER FORTUNE.AI. The logo consists of a stylized human figure with a globe on top, followed by the company name in a sans-serif font. The color scheme is a light teal or cyan, giving the logo a modern and tech-oriented feel.

#### Device Description IV.

The device allows users to interact with the software application via a web interface to upload, inspect, assess myocardial perfusion from Bull's Eye images. The user can change the quantitative settings to correct for numerical calculations and clinical adjustments.

The device is designed to take images produced by GE Medical Systems Nuclear Quantitative Perfusion SPECT software and process the data to provide both numerical analysis of the Bull's Eye images to help assess for myocardial perfusions, and generate a report based on the users report settings and preference.

The algorithm segments bull's eye images from SPECT images generated by GE's workstation and conducts quantitative analysis based on the color settings set by the user. The color scale is designed to follow GE's design convention, where the color red is indicative of a normal condition and blue representing severe perfusion. Each of the 17 segments would produce a quantitative evaluation under rest and stress conditions based on the color scale. The clinician would then design and fill in diagnosis terminologies that is best suited for each associated numerical results of each segment and generate a template report documenting the patient's condition.

### Intended User Population

The intended users of the device are trained nuclear radiologists.

### Intended Patient Population

The target population of the device are patients who receive cardiac SPECT imaging.

### Description of user interface and outputs

The device displays Bull's Eye images of the heart along with myocardial segments overlaid on top to allow end users to assess myocardial perfusions. The device interacts with DICOM files generated from GE Medical Systems software workstation. The results and settings are displayed via a web interface where the end user uploads files, inspect quantitative results, adjust settings and generate a report.

{5}------------------------------------------------

Image /page/5/Picture/0 description: The image shows the logo for Ever Fortune AI. The logo consists of a stylized human figure with a green sphere on top, representing the head. The sphere is made up of interconnected dots, suggesting a network or connection. To the right of the figure, the text "EVER FORTUNE.AI" is displayed in a light blue color, with the "O" in "FORTUNE" replaced by a similar sphere as the one on top of the human figure.

### V. Intended Use / Indications For Use

EFAI CARDIOSUITE SPECT MYOCARDIAL PERFUSION AGILE WORKFLOWS is an image processing software that provides analysis on DICOM images acquired from GE Medical Systems Nuclear Quantitative Perfusion SPECT software to support appropriately trained healthcare professionals in the evaluation and assessment of myocardial perfusions.

It provides the following functionality:

- · Segmentation of the Bull's Eye images from the original DICOM
- Analysis of the Bull's Eye images to help assess perfusion
- · Custom settings to generate text reports

The results of this processing may be used to aid in evaluating and assessing myocardial perfusions.

The system is an adjunct tool for GE Medical Systems Nuclear Quantitative Perfusion SPECT software.

#### Comparison of Technological Characteristics with Predicate Device VI.

The following table compares the EFAI SPECT Workflows to the predicate device with respect to intended use, indications for use, principles of operation, technological characteristics, device modalities and forms the basis for the determination of substantial equivalence. The comparison table shows that the subject device does not raise any new questions of safety or effectiveness as compared to the predicate device.

The subject device and predicate devices share the same technological characteristics:

- ◆ Interface is able to review, transfer, process, storage and report of myocardial perfusion SPECT images;
- � Used to receive the SPECT image data;
- � Generation of display and report the Nuclear Medicine Cardiology medical images

{6}------------------------------------------------

Image /page/6/Picture/1 description: The image shows a logo for a company called "EVER FORTUNE.AI". The logo consists of a stylized human figure with a globe on top of its head, and the company name is written in a sans-serif font to the right of the figure. The color scheme is a light teal.

| Table - Comparison Table                        |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   |                                                                                                                                                                                                                                                                                                                                                                                                            |                                                                                                                                                                                                                                                                           |                                                                                                                                                                                                                                                    |
|-------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
|                                                 | Proposed Device                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   | Predicate Device                                                                                                                                                                                                                                                                                                                                                                                           |                                                                                                                                                                                                                                                                           |                                                                                                                                                                                                                                                    |
| Attribute                                       | EFAI SPECT Workflows<br>(K213731)                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                 | AutoQUANT® Plus<br>(K040326)                                                                                                                                                                                                                                                                                                                                                                               | Difference                                                                                                                                                                                                                                                                |                                                                                                                                                                                                                                                    |
| Manufacturer                                    | Ever Fortune.AI Co., Ltd.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                         | ADAC LABORATORIES                                                                                                                                                                                                                                                                                                                                                                                          | NA                                                                                                                                                                                                                                                                        |                                                                                                                                                                                                                                                    |
| Regulation<br>Number                            | 21 CFR §890.1200                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  | 21 CFR §890.1200                                                                                                                                                                                                                                                                                                                                                                                           | Same                                                                                                                                                                                                                                                                      |                                                                                                                                                                                                                                                    |
| Regulatory Class                                | Class II                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                          | Class II                                                                                                                                                                                                                                                                                                                                                                                                   | Same                                                                                                                                                                                                                                                                      |                                                                                                                                                                                                                                                    |
| Product Code                                    | KPS                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                               | KPS                                                                                                                                                                                                                                                                                                                                                                                                        | Same                                                                                                                                                                                                                                                                      |                                                                                                                                                                                                                                                    |
| Device Property                                 | Software (SaMD)                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   | Software applications<br>(Module)                                                                                                                                                                                                                                                                                                                                                                          | Same                                                                                                                                                                                                                                                                      |                                                                                                                                                                                                                                                    |
| Intended Use / Indications for Use              |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   |                                                                                                                                                                                                                                                                                                                                                                                                            |                                                                                                                                                                                                                                                                           |                                                                                                                                                                                                                                                    |
| EFAI SPECT<br>Workflows<br>(K213731)            | EFAI CARDIOSUITE SPECT MYOCARDIAL PERFUSION AGILE WORKFLOWS is an<br>image processing software that provides analysis on DICOM images acquired from GE Medical<br>Systems Nuclear Quantitative Perfusion SPECT software to support appropriately trained<br>healthcare professionals in the evaluation and assessment of myocardial perfusions.<br>It provides the following functionality:<br>• Segmentation of the Bull's Eye images from the original DICOM<br>• Analysis of the Bull's Eye images to help assess perfusion<br>• Custom settings to generate text reports<br>The results of this processing may be used to aid in evaluating and assessing myocardial<br>perfusions.<br>The system is an adjunct tool for GE Medical Systems Nuclear Quantitative Perfusion SPECT<br>software. |                                                                                                                                                                                                                                                                                                                                                                                                            |                                                                                                                                                                                                                                                                           |                                                                                                                                                                                                                                                    |
| AutoQUANT®<br>Plus (K040326)                    | AutoQUANT® Plus applications are intended to enable an automated display, review, and<br>quantification of Nuclear Medicine Cardiology medical images and datasets.<br>AutoQUAINT® Plus may be used in multiple settings including the hospital, clinic, doctors<br>office, or remotely via dial up. The results provided should be reviewed by qualified healthcare<br>professionals (e.g., radiologists, cardiologists, or general nuclear medicine physicians) trained in<br>the use of medical imaging devices.                                                                                                                                                                                                                                                                               |                                                                                                                                                                                                                                                                                                                                                                                                            |                                                                                                                                                                                                                                                                           |                                                                                                                                                                                                                                                    |
| Data Type /<br>Device Source                    | EFAI SPECT Workflows<br>(K213731)                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                 | AutoQUANT® Plus<br>(K040326)                                                                                                                                                                                                                                                                                                                                                                               | Difference                                                                                                                                                                                                                                                                |                                                                                                                                                                                                                                                    |
| Applied Body<br>Parts                           | Left Ventricle                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    | Left Ventricle                                                                                                                                                                                                                                                                                                                                                                                             | Same                                                                                                                                                                                                                                                                      |                                                                                                                                                                                                                                                    |
| Data File Type                                  | Nuclear Medicine<br>Cardiology SPECT<br>Perfusion Image                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           | Nuclear Medicine<br>Cardiology SPECT<br>Perfusion Image                                                                                                                                                                                                                                                                                                                                                    | Same                                                                                                                                                                                                                                                                      |                                                                                                                                                                                                                                                    |
| Data Device Source                              | GE Medical System Israel,<br>Functional Imaging :<br>Myovation Software,<br>K201103                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                               | All types of cardiac SPECT<br>dataset; Nuclear Medicine<br>Cardiology medical images                                                                                                                                                                                                                                                                                                                       | Similar.<br>The data sources both<br>came from similar type<br>of SPECT device.                                                                                                                                                                                           |                                                                                                                                                                                                                                                    |
| Input Data<br>(Image Modality)                  | GE SPECT Scanning (Bull's<br>eye image in DICOM file)                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                             | All type Cardiac SPECT<br>raw data (Nuclear Medicine<br>Cardiology medical images<br>in DICOM SC file)                                                                                                                                                                                                                                                                                                     | No Significant<br>Difference.<br>The proposed device<br>acquires the GE SPECT<br>scanning images;<br>The predicate device<br>acquires the cardiac<br>SPECT raw data.<br>Both devices can receive<br>SPECT scanning & data.                                                |                                                                                                                                                                                                                                                    |
| Output Format<br>(Report Modality)              | Texts and Pictures;<br>Web page, HTML;<br>Structured Text File.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   | DICOM SC for snapshots<br>saved to the database; TIFF<br>or PNG for screen captures<br>saved to a folder on a local<br>drive; Output files are for<br>PowerPoint use only. Any<br>other usage of output files<br>(outside of PowerPoint) is<br>not supported.                                                                                                                                              | Similar type output<br>format in pictures<br>format;<br>The proposed device has<br>conducted the software<br>test report to ensure the<br>functionalities is safe and<br>effective.                                                                                       |                                                                                                                                                                                                                                                    |
| Data Storage                                    | Report format can be store<br>(PDF, word, TXT) in<br>Database Unit.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                               | Storage of all generated<br>results in a separate review<br>file.<br>Available formats are:                                                                                                                                                                                                                                                                                                                | Similar.<br>The proposed device is<br>used the texts and<br>pictures file format                                                                                                                                                                                          |                                                                                                                                                                                                                                                    |
|                                                 |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   | TIFF, JPEG, PNG, BMP,<br>DICOM SC.                                                                                                                                                                                                                                                                                                                                                                         | stored in Database Unit;<br>The predicate device is<br>used the snapshot file<br>saved in the local patient<br>database.<br>Both devices can store<br>the SPECT images.                                                                                                   |                                                                                                                                                                                                                                                    |
|                                                 | Features/Functions                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                | EFAI SPECT Workflows<br>(K213731)                                                                                                                                                                                                                                                                                                                                                                          | AutoQUANT® Plus<br>(K040326)                                                                                                                                                                                                                                              | Difference                                                                                                                                                                                                                                         |
| Segmentation<br>Algorithm                       |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   | YES<br>Hough Transform<br>(Segmentation of the Bull's<br>Eye Image)                                                                                                                                                                                                                                                                                                                                        | YES<br>(Ventricular Segmentation)                                                                                                                                                                                                                                         | Both devices include<br>segmentation algorithm.                                                                                                                                                                                                    |
| Orientation<br>Method                           |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   | NO                                                                                                                                                                                                                                                                                                                                                                                                         | YES                                                                                                                                                                                                                                                                       | No orientation method<br>was used in proposed<br>device.<br>The difference does not<br>raise any new questions<br>of safety or effectiveness.                                                                                                      |
| Segmental<br>Perfusion Scores<br>(Stress, Rest) |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   | YES<br>(Based on 17- Segment)                                                                                                                                                                                                                                                                                                                                                                              | YES<br>(Based on 17- or 20- Segment)                                                                                                                                                                                                                                      | Same in 17- segment<br>perfusion scores.                                                                                                                                                                                                           |
| Processing<br>Functions                         |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   | Segmentation of the Bull's<br>Eye images from the<br>original DICOM :<br>- Stress/Rest Score<br>- Percentage extent of the<br>defect in the polar map<br><br>Analysis of the Bull's Eye<br>images to help assess<br>perfusion :<br>- Color bar react in each of                                                                                                                                            | Quantitative Perfusion<br>SPECT (QPS) &<br>Quantitative Gated SPECT<br>(QGS) :<br>- Determine the location,<br>orientation, and anatomical<br>extent of the left ventricle<br>of the heart<br>- Construct 3D contour<br>maps of the heart<br>- Calculate the heart volume | The processing function<br>shares the same clinical<br>use including:<br>- 17-Segment mapper<br>Calculation and<br>display of polar map<br>- Stress/ Rest Score<br><br>The target of region on<br>the Visual Score on two<br>devices are not same, |
|                                                 | into 4 categories<br>(Max/Min/Mean/Median)<br>- Color Bar for user to<br>adjust threshold of scoring,<br>number of split (3/4/5)<br>- Area diagnosis of the<br>evaluation for coronary<br>heart disease                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           | - Calculate Transient<br>Ischemic Dilation (TID)<br>Quantitative Blood Pool<br>SPECT (QBS) :<br>- Generation left and right<br>valve plans and ventricular<br>endocardial surfaces<br>- Calculation left and right<br>valve ventricular volumes<br>- Calculate left and right<br>ventricular ejection<br>fractions<br>- Calculation and display of<br>polar maps<br>Quantitative Perfusion<br>Change (QPC) | devices are aimed to<br>score the region of<br>perfusion polar maps.                                                                                                                                                                                                      |                                                                                                                                                                                                                                                    |
| Interface                                       | Custom settings to generate                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                       | - ARG (automatic report                                                                                                                                                                                                                                                                                                                                                                                    | Similar.                                                                                                                                                                                                                                                                  |                                                                                                                                                                                                                                                    |
| Functions                                       | text reports :<br>- Modify and approve the<br>report<br>- Download the report<br>- Report filter setting<br>- Select and edit the<br>clinical findings                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            | generation)<br>- QARG (for reporting<br>purposes                                                                                                                                                                                                                                                                                                                                                           | Two devices can generate<br>and edit the report for<br>the users.                                                                                                                                                                                                         |                                                                                                                                                                                                                                                    |

{7}------------------------------------------------

Image /page/7/Picture/0 description: The image contains a logo for a company called EVER FORTUNE.AI. The logo consists of a stylized human figure with a green network-like structure as its head. The company name is written in a sans-serif font, with "EVER" on top of "FORTUNE.AI". The color scheme is primarily teal and green.

{8}------------------------------------------------

Image /page/8/Picture/0 description: The image contains a logo for a company called "EVER FORTUNE.AI". The logo consists of a stylized figure with a circular head and a plus-shaped body, rendered in a gradient of light blue. Above the figure's head is a green sphere with a network of lines connecting points on its surface. To the right of the figure is the company name, with "EVER" in a larger font size and "FORTUNE.AI" in a smaller font size below it.

{9}------------------------------------------------

Image /page/9/Picture/0 description: The image contains a logo for a company called EVER FORTUNE.AI. The logo consists of a stylized human figure with a globe above its head, all in a teal color. The text "EVER" is positioned to the right of the figure, with "FORTUNE.AI" below it in a smaller font size.

{10}------------------------------------------------

Image /page/10/Picture/0 description: The image shows the logo for Ever Fortune AI. The logo consists of a stylized person icon with a globe on top, followed by the text "EVER FORTUNE.AI". The person icon and text are in a light blue color, while the globe is in a light green color.

#### Performance Data - Non-Clinical VII.

The following performance data were provided in support of the substantial equivalence determination.

To demonstrate safety and effectiveness of EFAI SPECT Workflows and to show substantial equivalence to the predicate device, EFAI completed the non-clinical tests. Results confirm that the design inputs and performance specifications for the device are met. The EFAI SPECT Workflows passed the testing in accordance with internal requirements, national standards, and international standards shown below, supporting its safety and effectiveness, and its substantial equivalence to the predicate device:

- . Software verification and validation per IEC 62304/FDA Guidance
- . Application of usability engineering to medical devices - Part 1 per IEC 62366-1
- . Guidance on the application of usability engineering to medical devices per IEC 62366-2

EFAI SPECT Workflows did not require clinical study since substantial equivalence to the currently market and predicate device was demonstrated with the following attribute:

- . Principle of Operation;
- . Indications for Use;
- . Fundamental scientific technology;
- . Non-clinical performance testing:
- . Safety and effectiveness.

#### Statement of Substantial Equivalence VII.

EverFortune.AI Co., Ltd. Choose the AutoQUANT® Plus (K040326) as a predicate device.

AutoQUANT® Plus is a suite of application are intended to enable an automated display, review, and quantification of Nuclear Medicine Cardiology medical images and datasets.

The proposed device is available to assess "bull's eye" images to show whether there are any potential areas of perfusion defects and automatically generates a report for clinicians; the predicate device integrates 2 functionalities, Quantitative Perfusion SPECT (QPS) and Quantitative Gated SPECT (QGS) into a single application for LV (Left Ventricle) extraction and analysis.

Both devices can assist clinicians in assessing bull's eye images and generating report, increasing the work efficiency.

{11}------------------------------------------------

Image /page/11/Picture/0 description: The image shows the logo for Ever Fortune AI. The logo consists of a stylized figure in teal with a green globe above it. To the right of the figure is the text "EVER" in a larger font, with "FORTUNE.AI" below it in a smaller font. The logo has a modern and tech-oriented design.

EFAI SPECT Workflows is substantial equivalence to the function of storing, quantifying and report the nuclear medicine cardiology medical images with predicate device - AutoOUANT® Plus.

EFAI SPECT Workflows does not raise different questions of safety and effectiveness than associated with the predicate device.

### IX. Conclusion

EFAI SPECT workflows is submitted the information in this premarket notification, including the performance testing and predicate device comparisons support the device; the verification and validation activities demonstrate that EFAI SPECT Workflows perform as intended in the specific use conditions. The difference between the proposed device and predicate devices do not affect the indication for use, safety and effectiveness. And no issues are raised regarding safety regarding safety and effectiveness.

The result of the comparison of the design, intended use and testing results with the software release acceptance criteria, EverFortune.AI is the opinion, that AutoQUANT® Plus is substantial equivalent to and perform as well as the predicate device EFAI SPECT workflows.

---

**Source:** [https://fda-staging.innolitics.com/device/K213731](https://fda-staging.innolitics.com/device/K213731)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com