1688 4K Camera System, L11 LED Light Source with AIM, AIM SafeLight Cable, Precision S 4K Sinuscopes
K211202 · Stryker · GWG · Aug 6, 2021 · Neurology
Device Facts
Record ID
K211202
Device Name
1688 4K Camera System, L11 LED Light Source with AIM, AIM SafeLight Cable, Precision S 4K Sinuscopes
Applicant
Stryker
Product Code
GWG · Neurology
Decision Date
Aug 6, 2021
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 882.1480
Device Class
Class 2
Attributes
Real-World Evidence, Pediatric
Real-World Evidence
Submission
Device
Sponsor
RWD Sources
RWE Use Summary
Key Tags
K211202 · Aug 6, 2021
1688 4K Camera System, L11 LED Light Source with AIM, AIM SafeLight Cable, Precision S 4K Sinuscopes
Stryker
Published clinical literature
Published literature was provided to support a reasonable assurance of safety and effectiveness for the AIM System for use in neurosurgery indications.
Neurosurgery; Literature review; Clinical outcomes
Clinical Evidence
Study Design
Population
Comparator
Key Endpoints
Published literature; Literature review
Patients undergoing minimally invasive cranial neurosurgery and endonasal skull base surgery
Not applicable for this study
Safety and effectiveness for neurosurgery indications
Indications for Use
Endoscopic white light and near-infrared illumination and imaging during endoscopic procedures.
Device Story
The AIM System is an endoscopic 4K visible and near-infrared (NIR) imaging system. It consists of a camera system, L11 LED light source, SafeLight cable, endoscopes, IRIS Ureteral Kit, and SPY AGENT GREEN imaging agent. The system uses an optical endoscope and coupler to project light onto CMOS image sensors, which acquire continuous image data. This data is processed into a video stream for display. Surgeons use the system in OR settings to perform minimally invasive procedures, including neurosurgery and laparoscopy. The device provides real-time visual assessment of tissue perfusion, blood flow, and anatomical structures (biliary ducts, ureters, lymphatics) via fluorescence and transillumination. This visual feedback assists surgeons in intraoperative decision-making, potentially improving surgical outcomes by enhancing visualization of critical structures and tissue health.
Clinical Evidence
No new clinical trials were conducted. Safety and effectiveness for neurosurgery indications were supported by published literature. Bench testing included electrical safety, EMC, laser safety, biocompatibility (ISO 10993), cleaning, sterilization, software validation (IEC 62304), and usability (IEC 62366-1). Comparative animal testing was performed in compliance with GLP (21 CFR Part 58) to validate performance against legally marketed devices.
Technological Characteristics
System includes 4K camera, L11 LED light source (RGB LEDs/Infrared Laser), SafeLight cable, and rigid rod lens endoscopes (3.1mm/4.0mm OD). Imaging modes: White light, NIR fluorescence (806nm), NIR transillumination (830nm). Biocompatibility per ISO 10993. Sterilization via moist heat or hydrogen peroxide. Connectivity: Digital video output. Laser safety: Class 1M.
Indications for Use
Indicated for adults and pediatric patients (aged one month and older for general surgery; >6 years for endonasal skull base surgery; 12-17 years for biliary duct visualization). Used for general laparoscopy, ear endoscopy, sinuscopy, neurosurgery, and plastic surgery. Enables real-time endoscopic visible and near-infrared fluorescence imaging (with SPY AGENT GREEN) for visual assessment of vessels, blood flow, tissue perfusion, lymphatic system visualization, and biliary duct visualization. Also indicated for ureter transillumination.
Regulatory Classification
Identification
A neurological endoscope is an instrument with a light source used to view the inside of the ventricles of the brain.
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image contains the logo of the U.S. Food and Drug Administration (FDA). On the left is the Department of Health and Human Services logo. To the right of that is the FDA logo, which is a blue square with the letters "FDA" in white. To the right of the blue square is the text "U.S. FOOD & DRUG ADMINISTRATION" in blue.
August 6, 2021
Stryker April Malmborg Senior Director, Regulatory Affairs 5900 Optical Court San Jose. California 95138
Re: K211202
Trade/Device Name: 1688 4K Camera System, L11 LED Light Source with AIM, AIM SafeLight Cable, Precision S 4K Sinuscopes Regulation Number: 21 CFR 876.1500 Regulation Name: Endoscope and Accessories Regulatory Class: Class II Product Code: GCJ, GWG, OWN, FCS, FCW, EOB Dated: July 8, 2021 Received: July 9, 2021
Dear April Malmborg:
We have reviewed vour Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database located at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal
{1}------------------------------------------------
#### Page
statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803) for devices or postmarketing safety reporting (21 CFR 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reportingcombination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-device-safety/medical-device-reportingmdr-how-report-medical-device-problems.
For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medicaldevices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-device-advice-comprehensive-regulatoryassistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).
Sincerely,
for
Adam Pierce Assistant Director DHT5A: Division of Neurosurgical, Neurointerventional and Neurodiagnostic Devices OHT5: Office of Neurological and Physical Medicine Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
## Indications for Use
510(k) Number (if known) K211202
#### Device Name
AIM (Advanced Imaging Modality) System
#### Indications for Use (Describe)
1688 4K Camera System with Advanced Imaging Modality (AIM):
The 1688 Video Camera is indicated for use in general laparoscopy, ear endoscopy, ear endoscopy, sinuscopy, neurosurgery and plastic surgery whenever a laparoscope/ arthroscope/ sinuscope/ sinuscope is indicated for use. The 1688 Video Camera is indicated for adults and pediatric patients.
A few examples of the more common endoscope surgeries are Laparoscopic cholecystectomy, Laparoscopic hernia repair, Laparoscopic appendectomy, Laparoscopic pelvic lymph node detection, Laparoscopically assisted hysterectomy, Laparoscopic and thorascopic anterior spinal fusion, Anterior cruciate ligament reconstruction, Knee arthroscopy, Small joint arthroscopy, Decompression fixation, Wedge resection, Lung biopsy, Dorsal sympathectomy, Pleurodesis, Internal mammary artery dissection for coronary artery bypass grafting where endoscopic visualization is indicated and Examination of the evacuated cardiac chamber during performance of valve replacement.
The users of the 1688 Video Camera are general and pediatric surgeons, gynecologists, cardiac surgeons, thoracic surgeons, plastic surgeons, orthopedic surgeons, neurosurgeons and urologists.
L11 LED Light Source with Advanced Imaging Modality (AIM) and SafeLight Cable:
Upon intravenous administration of SPY AGENTTM GREEN (indocyanine green for injection, USP), the L11 LED Light Source with AIM and SafeLightTM Cable are used with SPY AGENT GREEN to provide real-time endoscopic visible and near-infrared fluorescence imaging. The L11 LED Light Source with AIM and SafeLight Cable enable surgeons to perform minimally invasive surgery using standard endoscopic visual assessment of vessels, blood flow and related tissue perfusion in adults and pediatric patients aged one month and older, and visualization of at least one of the major extra-hepatic bile duct, common bile duct and common hepatic duct) in adults and pediativ patients 12 to 17 years of age, using near-infrared imaging.
Fluorescence imaging of biliary ducts with the L11 LED Light Source with AIM and SafeLight Cable is intended for use with standard-of-care white light and, when indicated, intraoperative cholangiography. The devices are not intended for standalone use for biliary duct visualization.
Additionally, the L11 LED Light Source with AIM and SafeLight Cable enable surgeons to perform minimally invasive cranial neurosurgery in adults and pediatric patients and endonasal skull base surgery in adults and pediatric patients > 6 years of age using standard endoscopic visible light as well as visual assessment of vessels, blood flow and related tissue perfusion using near-infrared imaging.
Upon interstitial administration of SPY AGENT GREEN, the L11 LED Light Source with AIM and SafeLight Cable is used to perform intraoperative fluorescence imaging and visualization of the lymphatic system, including lymphatic vessels and lymph nodes.
The L11 LED Light Source is also intended to transilluminate the ureter during open or laparoscopic surgical procedures.
#### Precision S 4K Sinuscope:
The Precision S 4K Sinuscope is intended for use in otolaryngology and head and neck procedures, including thinology, endoscopic plastic and reconstructive surgery. The Precision S 4K Sinuscope is also intended for use in minimally invasive cranial neurosurgery in adults and pediatric patients and endonasal skull base surgery in adults and pediatric patients > 6 years ofage.
Type of Use (Select one or both, as applicable)
X Prescription Use (Part 21 CFR 801 Subpart D)
Over-The-Counter Use (21 CFR 801 Subpart C)
{3}------------------------------------------------
#### CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
{4}------------------------------------------------
This 510(k) summary of safety and effectiveness information is being submitted in accordance with the requirements of 21 C.F.R Part 807.92(c).
## Submitter:
| Applicant: | Stryker Endoscopy<br>5900 Optical Court<br>San Jose, CA 95138 |
|-----------------|--------------------------------------------------------------------------------|
| Contact Person: | Jessie Duong<br>Manager, Regulatory Affairs<br>Email: jessie.duong@stryker.com |
| Date Prepared: | July 7, 2021 |
#### Subject Device:
The subject device is the AIM (Advanced Imaging Modality) System, specifically the following system components:
| Name of Device: | 1688 4K Camera System with Advanced Imaging Modality |
|-------------------------|-----------------------------------------------------------------------------------------------------------------|
| Common or<br>Usual Name | 3-chip Video Camera |
| Classification<br>Name: | Laparoscope, General and Plastic Surgery (21 C.F.R. §876.1500)<br>Endoscope, Neurological (21 C.F.R. §882.1480) |
| Regulatory Class: | II |
| Product Code: | GCJ<br>GWG |
| 510(k) Review<br>Panel: | General & Plastic Surgery<br>Neurology |
| Name of Device: | L11 LED Light Source with Advanced Imaging Modality |
|-------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Common or<br>Usual Name | Light Source, Illuminator |
| Classification<br>Name: | Confocal Optical Imaging1 (21 C.F.R. §876.1500)<br>Fiberoptic light ureteral catheter2 (21 C.F.R. §876.4020)<br>Light Source, Fiberoptic, Routine3 (21 C.F.R. §876.4020)<br>Endoscope, Neurological (21 C.F.R. §882.1480) |
| Regulatory Class: | II |
| Product Code: | OWN1<br>FSC2<br>FCW3<br>GWG4 |
| 510(k) Review<br>Panel: | General & Plastic Surgery1<br>Gastroenterology/ Urology2,3<br>Neurology4 |
{5}------------------------------------------------
Image /page/5/Picture/1 description: The image shows the word "stryker" in a bold, sans-serif font. The letters are black and the background is white. The word is likely a logo or brand name.
1When used for assessment of vessels, blood flow and related tissue perfusion, and at least one of the major extra-hepatic bile ducts (cystic duct, common bile duct and common hepatic duct), using near-infrared imaging
2When used to transilluminate the ureter during open or laparoscopic surgical procedures
3When used to provide standard endoscopic visible light to support real-time endoscopic visible imaging.
4 When used to provide standard endoscopic visible light and near-infrared imaging during minimally invasive cranial
neurosurgery and endonasal skull base surgery.
| Name of Device | Precision S 4K Sinuscope |
|----------------------|------------------------------------------------------------------------------------------|
| Common or Usual Name | Sinuscope |
| Classification Name | Nasopharyngoscope (21 C.F.R. §874.4760)<br>Endoscope, Neurological (21 C.F.R. §882.1480) |
| Regulatory Class | Class II |
| Product Code | EOB<br>GWG |
| 510(k) Review Panel: | Ear Nose & Throat<br>Neurology |
#### Predicate Device(s):
| Karl Storz ICG Imaging System | K180146 (primary) |
|-----------------------------------------------------------------------------------|---------------------|
| AIM System: 1688 4K Camera<br>System, L11 LED Light Source and<br>SafeLight Cable | K210088 (secondary) |
NOTE: The predicate device has not been subject to a design-related recall.
#### Reference Device(s):
| Precision S 4K Sinuscope | K191102 |
|--------------------------|---------|
|--------------------------|---------|
#### Device Description:
The AIM (Advanced Imaging Modality) System is an endoscopic real-time 4K visible white light and near-infrared light illumination and imaging system. The AIM (Advanced Imaging Modality) System includes the following components: (1) A Camera System for processing nearinfrared and visible light images; (2) A Light Source and SafeLight Cable for emitting light within the visible light as well as near-infrared light spectrum; (3) An Endoscope for visible light and near-infrared light illumination and imaging; (4) The IRIS Ureteral Kit for transillumination of the ureters; and, (5) SPY AGENT 104 GREEN (indocyanine green for injection, USP) an optical imaging agent used for fluorescence imaging.
{6}------------------------------------------------
# Indications for Use:
| Subject Device | Predicate Devices | |
|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| AIM System<br>This Submission | Karl Storz ICG Imaging System<br>(K180146, primary) | AIM System<br>(K210088, secondary) |
| Intended Use:<br>Endoscopic white light and near-infrared<br>illumination and imaging during endoscopic<br>procedures. | Intended Use:<br>Same as subject device | Intended Use:<br>Same as subject device. |
| Indications for Use:<br>L11 LED Light Source with AIM and<br>SafeLight Cable | Indications for Use:<br>Karl Storz ICG Imaging System | Indications for Use:<br>L11 LED Light Source with AIM<br>and SafeLight Cable |
| Upon intravenous administration of SPY<br>AGENTTM GREEN (indocyanine green for<br>injection, USP), the L11 LED Light Source<br>with AIM and SafeLightTM Cable are used<br>with SPY AGENT GREEN to provide real-<br>time endoscopic visible and near infrared<br>fluorescence imaging. The L11 LED Light<br>Source with AIM and SafeLight Cable<br>enable surgeons to perform minimally<br>invasive surgery using standard endoscopic<br>visual light as well as visual assessment of<br>vessels, blood flow and related tissue<br>perfusion in adults and pediatric patients<br>aged one month and older, and visualization<br>of at least one of the major extra-hepatic<br>bile ducts (cystic duct, common bile duct<br>and common hepatic duct) in adults and<br>pediatric patients 12 to 17 years of age,<br>using near-infrared imaging. | The KARL STORZ ICG Imaging<br>System is intended to provide real-<br>time visible (VIS) and near-infrared<br>(NIR) fluorescence imaging.<br><br>The KARL STORZ Endoscopic ICG<br>System enables surgeons to perform<br>minimally invasive surgery using<br>standard endoscopic visible light as<br>well as visual assessment of vessels,<br>blood flow and related tissue<br>perfusion, or at least one of the major<br>extra-hepatic bile ducts (cystic duct,<br>common bile duct and common<br>hepatic duct), using near infrared<br>imaging. Fluorescence imaging of<br>biliary ducts with the KARL STORZ<br>Endoscopic ICG System is intended<br>for use with standard of care white<br>light and, when indicated,<br>intraoperative cholangiography. The<br>device is not intended for standalone<br>use for biliary duct visualization. | Upon intravenous administration of<br>SPY AGENTTM GREEN<br>(indocyanine green for injection,<br>USP), the L11 LED Light Source<br>with AIM and SafeLightTM Cable is<br>used with SPY AGENT GREEN to<br>provide real-time endoscopic visible<br>and near infrared fluorescence<br>imaging. The L11 LED Light Source<br>with AIM and SafeLight Cable<br>enable surgeons to perform<br>minimally invasive surgery using<br>endoscope visual light as well as<br>visual assessment of vessels, blood<br>flow and related tissue perfusion in<br>adults and pediatric patients aged one<br>month or older, and visualization of<br>at least one of the major extra-hepatic<br>bile ducts (cystic duct, common bile<br>duct and common hepatic duct) in<br>adults and pediatric patients 12 to 17<br>years of age, using near-infrared<br>imaging. |
| Fluorescence imaging of biliary ducts with<br>the L11 LED Light Source with AIM and<br>SafeLight Cable is intended for use with<br>standard-of-care white light and, when<br>indicated, intraoperative cholangiography.<br>The devices are not intended for standalone<br>use for biliary duct visualization. | Additionally, the KARL STORZ<br>Endoscopic ICG System enables<br>surgeon to perform minimally<br>invasive cranial neurosurgery in<br>adults and pediatrics and endonasal<br>skull base surgery in adults and<br>pediatrics > 6 years of age using<br>standard endoscopic visible light as<br>well as visual assessment of vessels,<br>blood flow and related tissue<br>perfusion using near infrared<br>imaging. | Fluorescence imaging of biliary ducts<br>with the L11 LED Light Source with<br>AIM and SafeLight Cable is intended<br>for use with standard-of-care white<br>light and, when indicated,<br>intraoperative cholangiography. The<br>devices are not intended for<br>standalone use for biliary duct<br>visualization. |
| Additionally, the L11 LED Light Source<br>with AIM and SafeLight Cable enable<br>surgeons to perform minimally invasive<br>cranial neurosurgery in adults and pediatric<br>patients and endonasal skull base surgery in<br>adults and pediatric patients > 6 years of<br>age using standard endoscopic visible light<br>as well as visual assessment of vessels,<br>blood flow and related tissue perfusion<br>using near infrared imaging. | The KARL STORZ VITOM II ICG<br>System is intended for capturing and<br>viewing fluorescent images for the<br>visual assessment of blood flow, as<br>an adjunctive method for the<br>evaluation of tissue perfusion, and<br>related tissue-transfer circulation in<br>tissue and free flaps used in plastic,<br>micro- and reconstructive surgical<br>procedures. The VITOM II ICG | Upon interstitial administration of<br>SPY AGENT GREEN, the L11 LED<br>Light Source with AIM and<br>SafeLight Cable is used to perform<br>intraoperative fluorescence imaging<br>and visualization of the lymphatic<br>system, including lymphatic vessels<br>and lymph nodes.<br><br>The L11 LED Light Source is also<br>intended to transilluminate the ureter<br>during open or laparoscopic surgical |
| Upon interstitial administration of SPY<br>AGENT GREEN, the L11 LED Light<br>Source with AIM and SafeLight Cable is<br>used to perform intraoperative fluorescence<br>imaging and visualization of the lymphatic<br>system, including lymphatic vessels and<br>lymph nodes. | | |
| Subject Device | | Predicate Devices |
| AIM System<br>This Submission | Karl Storz ICG Imaging System<br>(K180146, primary) | AIM System<br>(K210088, secondary) |
| The L11 LED Light Source is also intended<br>to transilluminate the ureter during open or<br>laparoscopic surgical procedures. | magnified view of the surgical field<br>in standard white light. | |
| 1688 4K Camera System<br>The 1688 Video Camera is indicated for use<br>in general laparoscopy, nasopharyngoscopy,<br>ear endoscopy, sinuscopy, neurosurgery and<br>plastic surgery whenever a laparoscope/<br>endoscope/ arthroscope/ sinuscope is<br>indicated for use. The 1688 Video Camera<br>is indicated for adults and pediatric patients.<br>A few examples of the more common<br>endoscope surgeries are Laparoscopic<br>cholecystectomy, Laparoscopic hernia<br>repair, Laparoscopic appendectomy,<br>Laparoscopic pelvic lymph node detection,<br>Laparoscopically assisted hysterectomy,<br>Laparoscopic and thorascopic anterior<br>spinal fusion, Anterior cruciate ligament<br>reconstruction, Knee arthroscopy, Small<br>joint arthroscopy, Decompression fixation,<br>Wedge resection, Lung biopsy, Pleural<br>biopsy, Dorsal sympathectomy, Pleurodesis,<br>Internal mammary artery dissection for<br>coronary artery bypass, Coronary artery<br>bypass grafting where endoscopic<br>visualization is indicated and Examination<br>of the evacuated cardiac chamber during<br>performance of valve replacement.<br>The users of the 1688 Video Camera are<br>general and pediatric surgeons,<br>gynecologists, cardiac surgeons, thoracic<br>surgeons, plastic surgeons, orthopedic<br>surgeons, ENT surgeons, neurosurgeons<br>and urologists. | | 1688 4K Camera System<br>The 1688 Video Camera is indicated<br>for use in general laparoscopy,<br>nasopharyngoscopy, ear endoscopy,<br>sinuscopy, and plastic surgery<br>whenever a laparoscope/ endoscope/<br>arthroscope is indicated for use. The<br>1688 Video Camera is indicated for<br>adults and pediatric patients aged one<br>month or older.<br>A few examples of the more common<br>endoscope surgeries are Laparoscopic<br>cholecystectomy, Laparoscopic<br>hernia repair, Laparoscopic<br>appendectomy, Laparoscopic pelvic<br>lymph node detection,<br>Laparoscopically assisted<br>hysterectomy, Laparoscopic and<br>thorascopic anterior spinal fusion,<br>Anterior cruciate ligament<br>reconstruction, Knee arthroscopy,<br>Small joint arthroscopy,<br>Decompression fixation, Wedge<br>resection, Lung biopsy, Pleural<br>biopsy, Dorsal sympathectomy,<br>Pleurodesis, Internal mammary artery<br>dissection for coronary artery bypass,<br>Coronary artery bypass grafting<br>where endoscopic visualization is<br>indicated and Examination of the<br>evacuated cardiac chamber during<br>performance of valve replacement.<br>The users of the 1688 Video Camera<br>are general and pediatric surgeons,<br>gynecologists, cardiac surgeons,<br>thoracic surgeons, plastic surgeons,<br>orthopedic surgeons, ENT/surgeons<br>and urologists.<br>N/A |
| Precision S 4K Sinuscope<br>The Precision S 4K Sinuscope is intended<br>for use in otolaryngology and head and<br>neck procedures, including rhinology,<br>endoscopic plastic and reconstructive<br>surgery.<br>The Precision S 4K Sinuscope is also<br>intended for use in minimally invasive<br>cranial neurosurgery in adults and pediatric<br>patients and endonasal skull base surgery in<br>adults and pediatric patients > 6 years of<br>age. | | |
{7}------------------------------------------------
{8}------------------------------------------------
# Comparison of Technological Characteristics with the Predicate Device:
| Item | | Subject Device | Predicate Device | |
|--------------------------|---------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------|-----------------------------------------------|
| | | AIM System<br>(This Submission) | Karl Storz ICG Imaging<br>System (K180146, primary) | AIM System<br>(K210088 secondary) |
| Manufacturer | | Stryker | Karl Storz | Stryker |
| Imaging Modes | | White Light<br>Near-infrared - fluorescence<br>Near-infrared - transillumination | White Light<br>Near-infrared - fluorescence | Same as subject<br>device. |
| System Components | | Camera System<br>Light Source and Light Cable<br>Endoscopes<br>IRIS Ureteral Kit<br>SPY AGENT GREEN | Camera System<br>Light Source and Light<br>Cable<br>Endoscopes | |
| Principles of Operations | | Via an optical endoscope and coupler, light is projected from a light source<br>onto one or more complementary metal oxide semiconductor image sensors<br>which acquire a continuous stream of image data. The image data is<br>processed to provide a video stream that is then sent to a display for<br>viewing. | Same as subject device | |
| Safety Standards | | IEC 60601-1<br>IEC 60601-2-18<br>IEC 60601-1-2<br>IEC 60825-1 | IEC 60601-1<br>IEC 60601-2-18<br>IEC 60601-1-2 | |
| Camera<br>System | Image<br>Processing/<br>Video Output | Digital | Same as subject device | |
| | Light Source/<br>Laser | RGB LEDs<br>Infrared Laser | Xenon Lamp | |
| | | | | |
| Light<br>Source | Infrared<br>Wavelengths | 806nm (used for NIR fluorescence)<br>830nm (used for NIR transillumination) | 690-790nm | |
| | Laser Safety<br>Classification | Class 1M | Not applicable | |
| Endoscope | Endoscope Type | Rigid rod lens | Same as subject device | Reference device |
| | Endoscope<br>Performance<br>Standards | ISO 8600-1 | Same as subject device | (K191102) is the<br>same as subject<br>device |
| | Transmission<br>Spectrum | Visible and near-infrared | Same as subject device | |
| | Outer Diameter | 3.1mm, 4.0mm | 4mm<br>5mm, 10mm | |
| | Working Length<br>(Outer<br>Diameter) | 125mm - 180mm<br>(3.1mm, 4.0mm) | 180mm (4mm OD)<br>290mm (5mm OD)<br>310mm (10mm OD) | |
| | Field of View | 80° - 105° | 80° | |
| | Depth of Field | 7mm - 35mm | 8mm - 38mm | |
| | Biocompatibility | ISO 10993-1<br>ISO 10993-5<br>ISO 10993-10<br>ISO 10993-11 | Same as subject device | |
| | Cleaning | Manual and Automated | Same as subject device | |
| | Sterilization | Moist Heat<br>Hydrogen Peroxide | Moist Heat | |
{9}------------------------------------------------
Image /page/9/Picture/1 description: The image shows the word "stryker" in a bold, sans-serif font. The letters are black and the background is white. The word is written in all lowercase letters.
### Performance Data:
Testing was completed in accordance with the following:
| Test | Method | Result |
|---------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------|
| Electrical Safety | ANSI/AAMI ES60601-1:2005 + A1:2012; | Pass |
| | IEC 60601-2-18:2009 | |
| | IEC 60601-1-6:2013 | |
| EMC Testing | IEC 60601-1-2:2014 | Pass |
| Laser Safety | IEC 60825-1:2014 | Pass |
| Biocompatibility | ISO 10993-1:2009 | Pass |
| | ISO 10993-5:2009 | |
| | ISO 10993-10:2010 | |
| | ISO 10093-11:2017 | |
| Cleaning | AAMI TIR30:2011 | Pass |
| | ISO 15883-5:2005 | |
| Sterilization | ISO 14937:2009 | Pass |
| | AAMI TIR12:2010…
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.