VFS1 Bipolar Electrosurgical Generator

K200169 · FHC, Inc. · GEI · May 14, 2020 · General, Plastic Surgery

Device Facts

Record IDK200169
Device NameVFS1 Bipolar Electrosurgical Generator
ApplicantFHC, Inc.
Product CodeGEI · General, Plastic Surgery
Decision DateMay 14, 2020
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 878.4400
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The VFS1 Bipolar Generator is intended for use in surgical procedures for cutting tissue and coagulating blood vessels. Procedures must be performed by a surgeon with experience in the use of electrosurgical devices and generators.

Device Story

VFS1 Bipolar Electrosurgical Generator provides 1 MHz RF energy for cutting and coagulating living human tissue; includes integrated variable-rate irrigation pump for saline delivery. Used in hospitals and clinical settings by surgeons. System inputs include user-selected power settings via rotary/pushbutton switches and foot pedal activation. Device provides audible feedback via tone generator and visual feedback via LCD display (power settings, irrigation, system errors/warnings). Earth-isolated bipolar output minimizes leakage current. Safety features include continuous monitoring of critical parameters with alerts. Benefits include precise tissue management and vessel coagulation during surgery.

Clinical Evidence

No clinical data. Evidence consists of bench testing including hardware verification (input/output, RF power, overcurrent protection, irrigation, mechanical, environmental, and shipping tests per ISTA-3A) and ex vivo comparability studies using tissue samples (steak, liver, kidney) to verify system operation.

Technological Characteristics

Bipolar electrosurgical generator; 1 MHz RF output (Cut: 0-100W, Coag: 0-50W). Features peristaltic irrigation pump (DC motor). Components: generator, foot pedal, power cord, tubing set. Interface: LCD display, rotary/pushbutton controls. Earth-isolated output. Connectivity: industry-standard connectors for bipolar forceps. Power: AC wall receptacle.

Indications for Use

Indicated for micro, macro, and endoscopic bipolar irrigation, cutting and coagulating of tissue and the coagulation of blood vessels in all types of surgery.

Regulatory Classification

Identification

An electrosurgical cutting and coagulation device and accessories is a device intended to remove tissue and control bleeding by use of high-frequency electrical current.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/0 description: The image shows the logo of the U.S. Food and Drug Administration (FDA). On the left is the Department of Health and Human Services logo. To the right of that is the FDA logo, which is a blue square with the letters "FDA" in white. To the right of the blue square is the text "U.S. FOOD & DRUG ADMINISTRATION" in blue. May 14, 2020 FHC, Inc. % Craig Pagan, Consultant C2C Development, LLC 1135 W NASA Blvd, Suite 500 Melbourne, Florida 32901 Re: K200169 Trade/Device Name: VFS1 Bipolar Electrosurgical Generator Regulation Number: 21 CFR 878.4400 Regulation Name: Electrosurgical Cutting and Coagulation Device and Accessories Regulatory Class: Class II Product Code: GEI Dated: April 10, 2020 Received: April 14, 2020 Dear Craig Pagan: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database located at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803) for {1}------------------------------------------------ devices or postmarketing safety reporting (21 CFR 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reportingcombination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-device-safety/medical-device-reportingmdr-how-report-medical-device-problems. For comprehensive regulatory information about mediation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medicaldevices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-device-advice-comprehensive-regulatoryassistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100). Sincerely, Long Chen, Ph.D. Assistant Director DHT4A: Division of General Surgery Devices OHT4: Office of Surgical and Infection Control Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ #### DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration ## Indications for Use 510(k) Number (if known) K200169 #### Device Name VFS1 Bipolar Electrosurgical Generator #### Indications for Use (Describe) The VFS1 Bipolar Electrosurgical Generator is indicated for use in micro, and endoscopic bipolar irrigation, cutting and coagulating of tissue and the coagulation of blood vessels in all types of surgery. Type of Use (Select one or both, as applicable) [X] Prescription Use (Part 21 CFR 801 Subpart D) Over-The-Counter Use (21 CFR 801 Subpart C) ### CONTINUE ON A SEPARATE PAGE IF NEEDED. This section applies only to requirements of the Paperwork Reduction Act of 1995. ### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.* The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: > Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number." {3}------------------------------------------------ #### 510(K) SUMMARY SECTION 5 1. Submitter's name, address, telephone number, a contact person, and the date the summary was prepared: FHC, Inc. 1201 Main Street Bowdoin, ME-04287 Tel: 207-666-5651 Fax: 207-666-8292 Contact: Kelly Moeykens Preparation Date: April 6th, 2020 ### 2. Name(s) of the Device: | Proprietary/Trade Name: | VFS1 Bipolar Electrosurgical Generator | |-------------------------|---------------------------------------------------------------| | Common Name: | Bipolar Electrosurgical Generator or Electrosurgical Generato | | Regulation Number | 21 CFR 878.4400 | | Regulation Name: | Electrosurgical device | | Classification Panel | General and Plastic Surgery | | Product Code: | GEI | | Regulatory Class: | II | ### 3. Legally Marked Predicate Device to which the submitter claims substantial equivalence: | Trade Name: | Malis Bipolar 2000 Electrosurgical Generator | |----------------|----------------------------------------------| | 510(k) #: | K050364 | | Product Code: | GEI | | Decision Date: | March 9th, 2005 | | Trade Name: | MALISTM Irrigation Module 1000 | | 510(k) #: | K033499 | | Product Code: | GEI | | Decision Date: | November 28th, 2003 | {4}------------------------------------------------ ## 4. Description of device: The VFS1 Bipolar Electrosurgical Generator (referred to as generator or VFS1 Generator) is designed to cut and coagulate living human tissue during surgical procedures. The system provides 1 MHz Radio Frequency (RF) energy that is user/operator selectable based on the surgical procedure undertaken. The generator is configured for bipolar output and is earth isolated, to minimize leakage current, thus providing increased patient comfort and safety. The system will be provided with safety features that are continuously monitored and will provide warnings and/ or alerts when critical parameters exceed specified limits. The VFS1 Generator is designed to cut and coagulate living tissue during surgical procedures. The system includes a bipedal footswitch. The generator is equipped with a tone generator to provide audible feedback each time cutting, or coagulation is performed. The generator incorporates a variable-rate irrigation pump to provide saline flow during procedures. The VFS1 Generator is compatible with a variety of reusable bipolar products; i.e., insulated mirror finish bipolar forceps, disposable nonstick bipolar instruments as well as disposable bipolar cords and tubing products. ltems that are included in the system are: - VFS1 generator -CO 840 - . Footpedal- CO 841 | C0840 | Valley Forge Scientific<br>VFS1 Bipolar<br>Electrosurgical<br>Generator | |-------|-------------------------------------------------------------------------| | C0841 | Electrosurgical Foot<br>Pedal | {5}------------------------------------------------ # 5. Statement of Indications for Use: The VFS1 Bipolar Electrosurgical Generator is indicated for use in micro, macro, and endoscopic bipolar irrigation, cutting and coagulating of tissue and the coagulation of blood vessels in all types of surgery. # 6. Intended Use The VFS1 Bipolar Generator is intended for use in surgical procedures for cutting tissue and coagulating blood vessels. Procedures must be performed by a surgeon with experience in the use of electrosurgical devices and generators. | Technological<br>Characteristics | Valley Forge Scientific<br>(division of FHC Inc.)<br>VFS1 Electrosurgical<br>Generator | Valley Forge Scientific<br>Corp.<br>Malis 2000 Bipolar<br>Electrosurgical System | PREDICATE<br>Malis Irrigation Module<br>1000 | |----------------------------------|---------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------|---------------------------------------------------------------------| | Modalities | Electrosurgical Cutting<br>and Coagulation<br>Irrigation | Electrosurgical Cutting<br>and Coagulation | Irrigation | | Environment of<br>Use | Hospitals and Clinical<br>Settings where<br>electrosurgery is used. | Hospitals and Clinical<br>Settings where<br>electrosurgery is used. | Hospitals and Clinical<br>Settings where<br>electrosurgery is used. | | Power Source | AC Voltage from wall<br>receptacle | AC Voltage from wall<br>receptacle | AC Voltage from wall<br>receptacle | | Device (System)<br>Components | - Generator<br>- Foot pedal<br>- Power Cord<br>- Cord/Tubing Set<br>- Irrigation<br>Module(check) | - Generator<br>- Foot pedal<br>- Power Cord<br>- Cord/Tubing Set | - Peristaltic Pump<br>- Foot Pedal | | | LCD Display, displays: | LCD Display, displays: | | | | Cut and Coag Power<br>Settings | Cut and Coag Power<br>Settings | | | | Power Units | Power Units | | | Display Screen<br>Details | Tone Volume and<br>Brightness Settings | Tone and Voice Volume<br>and Brightness Settings | Built in Numeric display | | | System Errors and<br>Warnings | System Errors and<br>Warnings | | | | Irrigation Setting | Absent | | # 7. Comparison of Technological Characteristics to Predicate Devices {6}------------------------------------------------ | Technological<br>Characteristics | Valley Forge Scientific<br>(division of FHC Inc.)<br>VFS1 Electrosurgical<br>Generator | PREDICATE<br>Valley Forge Scientific<br>Malis 2000 Bipolar<br>Electrosurgical System | PREDICATE<br>Malis Irrigation Module<br>1000 | |----------------------------------|----------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------|-------------------------------------------------| | Pump Head Type | Peristaltic | N/A | Peristaltic | | Motor Type | DC electric motor | N/A | DC electric motor | | Irrigation<br>Delivery Method | Tubing set with industry<br>standard connectors | N/A | Tubing set with industry<br>standard connectors | | Patient interface | Bipolar forceps | N/A | Bipolar forceps | | Liquid Source | Saline bag | N/A | Saline bag | | Delivery Rate | Slow drip, medium drip,<br>fast drip | N/A | Slow drip, medium drip,<br>fast drip | | RF Output Mode | Bipolar | Bipolar | N/A | | RF Output Power<br>Range | Cut: 0 to 100 Watts<br>Coag: 0 to 50 Watts | Cut: 0 to 300 Watts<br>Coag: 0 to 50 Watts | N/A | | RF Output<br>Waveforms | Cut: 1 MHz sinewave<br>Coag: 1 MHz damped<br>aperiodic | Cut: 1 MHz sinewave<br>Coag: 1 MHz damped<br>aperiodic | N/A | | Output Power<br>Controls | Rotary Switches<br>Pushbutton Switches | Rotary Switches | Rotary Switches | | Power Activation | Foot pedal | Foot pedal and Finger<br>switches | Foot pedal | ## 8. Performance Data Non-clinical: Basic mechanical and functional capabilities were tested for the subject electrosurgical generator to determine substantial equivalence to the predicate device. This also includes a Comparibility Study of the subject device and the predicate device. Report Refer to section 18 for details. The following is a summary of components and testing performed: #### . VCP-09-103 – VFS1 Hardware Verification Testing Testing and inspection performed on the VFS1 Electrosurgical Generator, to verify compliance with the Product Development Specification, DSI-09-100. Testing included: - о Input Voltage - Input Frequency o - Input Protection o {7}------------------------------------------------ - Output Waveform O - RF Power Output O - RF Output vs Load Resistance O - O RF Overcurrent Protection - Over-dosage Protection O - Irrigation O - Real Time Clock O - Mechanical O - Operating Conditions O - Storage Conditions O - O Cooling - Transportation O - Shock O - Cleaning O - Front Panel Connections O - Rear Panel Connections O - Power Cord O - O Front Panel Controls - O Rear Panel Controls - Display O All testing met specifications. #### VCP-09-109 – VFS1 Comparibility Study Report ● Testing was performed on the VFS1 Electrosurgical Generator to verify proper operation of the generator with all the components and accessories working together as a system. Testing included Ex Vivo testing for Cut and Coag using steak, liver and kidney tissue samples. All testing was found to be acceptable. #### ● ROH-09-100 - VFS1 ROHS Verification Report RoHS Compliance was verified for all components and subassemblies of the VFS1 Surgical Generator, Model CO840. #### VDP-09-100 – Shipping Test Report ● Testing was performed to confirm that the external packaging configuration for the VFS1 Electrosurgical Generator provides a high probability of safe and intact arrival at the destination by confirming that the integrity of the packaging and its components withstand simulated shipping and handling stress and by demonstrating that the shipping and handling stresses have no adverse effect on the VFS1 Generator performance. Testing was performed per ISTA-3A Shipping Test and met all requirements. Clinical: No clinical data was used to determine substantial equivalence. {8}------------------------------------------------ # 9. Conclusion Based on the non-clinical performance data performed comparing the VFS1 Electrosurgical Generator to the predicate devices (Malis 2000 Bipolar Electrosurgical System and the Malis Irrigation Module 1000), it is concluded that the device is as safe, as effective, and performs as well as or better than the predicate device.
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...