MectaFix CL Fixation Button with Continuous Loop

K193165 · Medacta International S.A. · MBI · Feb 10, 2020 · Orthopedic

Device Facts

Record IDK193165
Device NameMectaFix CL Fixation Button with Continuous Loop
ApplicantMedacta International S.A.
Product CodeMBI · Orthopedic
Decision DateFeb 10, 2020
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 888.3040
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The MectaFix CL Fixation Button with Continuous Loop is indicated for use in reconstructive treatment and extracortical femoral fixation of an implanted anterior cruciate ligament reconstruction.

Device Story

MectaFix CL Fixation Button with Continuous Loop is an implantable device for ACL reconstruction. It consists of a Ti6Al4V ELI metal button, a UHMWPE continuous loop (15-60 mm) for graft coupling, and a UHMWPE pulling suture. During surgery, the surgeon uses the pulling suture to guide the graft and button through a femoral bone tunnel; once the button clears the lateral cortex, it is flipped to provide extracortical suspensory fixation. The device is provided sterile for single-use. It secures the ACL graft to the femur, facilitating healing and joint stability.

Clinical Evidence

Non-clinical bench testing only. Studies included cyclic loading, tensile strength testing per ASTM D2256/D2256M-10, cadaver testing, sterilization validation, shelf-life testing, and pyrogenicity testing (LAL test per EP 2.6.14/USP <85> and USP <151>).

Technological Characteristics

Materials: Ti6Al4V ELI (button), UHMWPE (loop and suture). Principle: Extracortical suspensory fixation. Form factor: Elongated button with continuous loop. Sterilization: Provided sterile. No software or electronic components.

Indications for Use

Indicated for patients undergoing anterior cruciate ligament (ACL) reconstruction requiring extracortical femoral fixation of the graft.

Regulatory Classification

Identification

A smooth or threaded metallic bone fixation fastener is a device intended to be implanted that consists of a stiff wire segment or rod made of alloys, such as cobalt-chromium-molybdenum and stainless steel, and that may be smooth on the outside, fully or partially threaded, straight or U-shaped; and may be either blunt pointed, sharp pointed, or have a formed, slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a guide pin for insertion of other implants, or it may be implanted through the skin so that a pulling force (traction) may be applied to the skeletal system.

Predicate Devices

Reference Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/0 description: The image shows the logo of the U.S. Food and Drug Administration (FDA). The logo consists of two parts: the Department of Health & Human Services logo on the left and the FDA logo on the right. The FDA logo is in blue and includes the letters "FDA" followed by the words "U.S. FOOD & DRUG ADMINISTRATION". February 10, 2020 Medacta International SA % Chris Lussier Director, Quality and Regulatory Medacta USA 3973 Delp Street Memphis, Tennessee 38118 Re: K193165 Trade/Device Name: MectaFix CL Fixation with Continuous Loop Regulation Number: 21 CFR 888.3040 Regulation Name: Smooth Or Threaded Metallic Bone Fixation Fastener Regulatory Class: Class II Product Code: MBI, HWC, JDR Dated: November 14, 2019 Received: November 15, 2019 Dear Chris Lussier: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database located at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's {1}------------------------------------------------ requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803) for devices or postmarketing safety reporting (21 CFR 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reportingcombination-products); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-device-safety/medical-device-reportingmdr-how-report-medical-device-problems. For comprehensive regulatory information about mediation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medicaldevices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-device-advice-comprehensive-regulatoryassistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100). Sincerely, Laura C. Rose, PhD Acting Assistant Director DHT6C: Division of Restorative, Repair, and Trauma Devices OHT6: Office of Orthopedic Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ ## Indications for Use 510(k) Number (if known) K193165 Device Name MectaFix CL Fixation Button with Continuous Loop Indications for Use (Describe) The MectaFix CL Fixation Button with Continuous Loop is indicated for use in reconstructive treatment and extracortical femoral fixation of an implanted anterior cruciate ligament reconstruction. Type of Use (Select one or both, as applicable) | <span style="font-size:12pt">☑ Prescription Use (Part 21 CFR 801 Subpart D)</span> | <span style="font-size:12pt">☐ Over-The-Counter Use (21 CFR 801 Subpart C)</span> | |------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------| |------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------| ## CONTINUE ON A SEPARATE PAGE IF NEEDED. This section applies only to requirements of the Paperwork Reduction Act of 1995. ## *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.* The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: > Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number." {3}------------------------------------------------ # 2.0 510(k) Summary #### I. Submitter Medacta International SA Strada Regina 6874 Castel San Pietro (CH) Switzerland Phone (+41) 91 696 60 60 Fax (+41) 91 696 60 66 Contact Person: Stefano Baj, Regulatory and Compliance Director, Medacta International SA Date Prepared: November 12, 2019 Date Revised: January 28, 2020 #### II. Device | Device Proprietary Name: | MectaFix CL Fixation Button with Continuous Loop | |--------------------------|---------------------------------------------------------------------------------| | Common or Usual Name: | Suture retention device, Non-absorbable surgical suture | | Classification Name: | Fastener, Fixation, Non-degradable, Soft tissue, Non-absorbable surgical suture | | Product Codes: | MBI (primary), HWC (secondary), JDR (secondary) | | Regulation Number: | 21 CFR 888.3040, 21 CFR 888.3030 | | Device Classification | II | #### III. Predicate Device Substantial equivalence is claimed to the following device: - . Endobutton Continuous Loop, K081098, Smith & Nephew, Inc., Endoscopy Division The following device is referenced in the submission: - MectaLock Ti Suture Anchor, K191300, Medacta International SA #### IV. Device Description The MectaFix CL Fixation Button with Continuous Loop is an implantable fixation button with a continuous loop used for the femoral fixation of the anterior cruciate ligament (ACL) graft by means of an extra-cortical suspensory fixation. It consists of a metal elongated button (Ti6AI4V ELI), a continuous loop (UHMWPE) ranging in length from 15 mm to 60 mm to be coupled with the graft, and a pulling suture (UHMWPE) to pull the construct through the prepared bone tunnel and to subsequently flip the button after passing the femoral lateral cortex. {4}------------------------------------------------ The MectaFix CL Fixation Button with Continuous Loop implants are provided sterile and are provided in single-use packages. #### Indications for Use V. The MectaFix CL Fixation Button with Continuous Loop is indicated for use in reconstructive treatment and extracortical femoral fixation of an implanted anterior cruciate ligament reconstruction. #### VI. Comparison of Technological Characteristics The MectaFix CL Fixation Button with Continuous Loop implants and the predicate device share the following characteristics: - shape: ● - dimension; - loop sizes; and ● - button material of construction. ● The MectaFix CL Fixation Button with Continuous Loop implants and the predicate devices are technologically different with respect to: - . number of sutures; and - suture materials. ● ## Discussion Based on the comparison of technological characteristics and performance data provided within this submission, the MectaFix CL Fixation Button with Continuous Loop implants are substantially equivalent to the identified predicate device. #### VII. Performance Data Testing was conducted according to written protocols with acceptance criteria that were based on standards. The following mechanical studies were performed on worst-case implants in support of a substantial equivalence determination: Non-Clinical Studies: - cvclic loading ● - . tensile strength per ASTM D2256/D2256M-10 - Cadaver testing ● - Sterilization validation - Shelf-life testing - Pyrogenicity . {5}------------------------------------------------ - Bacterial Endotoxin Test (LAL test) was conducted according to European o Pharmacopoeia §2.6.14 (which is equivalent to USP chapter <85>) and pyrogen test according to USP chapter <151> for pyrogenicity determination - the subject devices are not labeled as non-pyrogenic or pyrogen free о ## VIII. Conclusion The information provided with this submission supports that the MectaFix CL Fixation Button with Continuous Loop implants are substantially equivalent to the identified predicate devices. Substantial equivalence has been demonstrated through a comparison of intended use, design and technological characteristics, as well as performance evaluations.
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...