← Product Code [IYN](/productcode/IYN) · K192159

# Voluson E6, Voluson E8, Voluson E10 (K192159)

_GE Healthcare · IYN · Aug 29, 2019 · Radiology · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K192159

## Device Facts

- **Applicant:** GE Healthcare
- **Product Code:** [IYN](/productcode/IYN.md)
- **Decision Date:** Aug 29, 2019
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 892.1550
- **Device Class:** Class 2
- **Review Panel:** Radiology
- **Attributes:** Pediatric

## Indications for Use

The device is a general-purpose ultrasound system. Specific clinical applications remain the same as previously cleared: Fetal/OB; Abdominal (including GYN, pelvic and infertility monitoring/follicle development); Pediatric; Small Organ (breast, testes, thyroid etc.); Neonatal and Adult Cephalic; Cardiac (adult and pediatric); Musculo-skeletal Conventional and Superficial; Peripheral Vascular; Transvaginal (including GYN); Transrectal.

## Device Story

Mobile ultrasound console with keyboard, touch panel, and display; utilizes mechanical and electronic scanning transducers for real-time 2D/3D/4D imaging. Operated by clinicians in clinical settings for diagnostic imaging and fluid flow analysis. System processes acoustic signals to produce visual diagnostic images; supports measurement, digital image capture, review, and reporting. Voluson E10 includes additional scan channels and hardware for eM6C/eM6C G2 4D electronic probes compared to E6/E8 models. Output assists healthcare providers in clinical decision-making across various specialties. Benefits include non-invasive diagnostic visualization of internal structures and blood flow.

## Clinical Evidence

No clinical data required; substantial equivalence supported by bench testing, including acoustic output, biocompatibility, cleaning/disinfection effectiveness, and thermal/electrical/electromagnetic/mechanical safety testing per AAMI/ANSI ES60601-1, IEC60601-1-2, IEC60601-2-37, and ISO10993-1.

## Technological Characteristics

Mobile console with color LCD/TFT touch panel; mechanical and electronic scanning transducers; supports 2D/3D/4D imaging. Complies with AAMI/ANSI ES60601-1, IEC60601-1-2, IEC60601-2-37, ISO10993-1, ISO14971, and NEMA PS 3.1-3.20 (DICOM). Biocompatible patient-contact materials. Acoustic power levels below FDA limits.

## Regulatory Identification

An ultrasonic pulsed doppler imaging system is a device that combines the features of continuous wave doppler-effect technology with pulsed-echo effect technology and is intended to determine stationary body tissue characteristics, such as depth or location of tissue interfaces or dynamic tissue characteristics such as velocity of blood or tissue motion. This generic type of device may include signal analysis and display equipment, patient and equipment supports, component parts, and accessories.

## Predicate Devices

- Voluson E6_E8_E10 Diagnostic Ultrasound System ([K181985](/device/K181985.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

Image /page/0/Picture/0 description: The image contains the logo of the U.S. Food and Drug Administration (FDA). The logo consists of two parts: a symbol on the left and the text on the right. The symbol on the left is a stylized representation of a human figure. The text on the right reads "FDA U.S. FOOD & DRUG ADMINISTRATION" in blue letters. The words "U.S. FOOD & DRUG" are on the top line, and the word "ADMINISTRATION" is on the bottom line.

August 29, 2019

GE Healthcare c/o Bryan Behn RA Director 9900 Innovation Drive WAUWATOSA, WI 53226

Re: K192159

Trade/Device Name: Voluson E6, Voluson E8, Voluson E10 Regulation Number: 21 CFR 892.1550 Regulation Name: Ultrasonic pulsed doppler imaging system Regulatory Class: Class II Product Code: IYN, IYO, ITX Dated: August 7, 2019 Received: August 9, 2019

Dear Mr. Bryan Behn:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database located at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 

{1}------------------------------------------------

801); medical device reporting of medical device-related adverse events) (21 CFR 803) for devices or postmarketing safety reporting (21 CFR 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reportingcombination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-device-safety/medical-device-reportingmdr-how-report-medical-device-problems.

For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medicaldevices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-device-advice-comprehensive-regulatoryassistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).

Sincerely,

For

Thalia T. Mills, Ph.D. Director Division of Radiological Health OHT7: Office of In Vitro Diagnostics and Radiological Health Office of Product Evaluation and Quality Center for Devices and Radiological Health

Enclosure

{2}------------------------------------------------

Image /page/2/Picture/0 description: The image shows the logo for General Electric (GE). The logo is a blue circle with the letters "GE" in a stylized, cursive font in the center. The circle is surrounded by four water droplets, one at each quadrant of the circle. The logo is simple and recognizable, and it is associated with a well-known and established company.

## GE Healthcare 510(k) Premarket Notification Submission

### Section 4: Indications for Use Statement

Voluson E Series (Voluson E6 / Voluson E8 / Voluson E10)

{3}------------------------------------------------

Image /page/3/Picture/0 description: The image shows the General Electric (GE) logo. The logo consists of the letters 'GE' in a stylized, cursive font, enclosed within a circular frame. The frame has four decorative flourishes or 'teardrops' evenly spaced around its perimeter. The logo is presented in a blue color.

## GE Healthcare 510(k) Premarket Notification Submission

| DEPARTMENT OF HEALTH AND HUMAN SERVICES |
|-----------------------------------------|
| Food and Drug Administration            |
| <b>Indications for Use</b>              |
| Form Approved: OMB No. 0910-0120        |
| Expiration Date: 06/30/2020             |
| See PRA Statement below.                |

510(k) Number (if known)

K192159

Device Name Voluson E6, Voluson E8, Voluson E10

#### Indications for Use (Describe)

The device is a general-purpose ultrasound system. Specific clinical applications remain the same as previously cleared: Fetal/OB; Abdominal (including GYN, pelvic and infertility monitoring/follicle development); Pediatric; Small Organ (breast, testes, thyroid etc.); Neonatal and Adult Cephalic; Cardiac (adult and pediatric); Musculo-skeletal Conventional and Superficial; Peripheral Vascular; Transvaginal (including GYN); Transrectal.

Type of Use (Select one or both, as applicable)

X Prescription Use (Part 21 CFR 801 Subpart D)

Over-The-Counter Use (21 CFR 801 Subpart C)

#### CONTINUE ON A SEPARATE PAGE IF NEEDED.

This section applies only to requirements of the Paperwork Reduction Act of 1995.

#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*

The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information, Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:

> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov

"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."

FORM FDA 3881 (7/17)

Page 1 of 1

PSC Publishing Services (301) 443-6740 EF

{4}------------------------------------------------

Image /page/4/Picture/0 description: The image shows the logo for General Electric (GE). The logo consists of the letters "GE" written in a stylized, cursive font, enclosed within a blue circle. There are three water droplet-like shapes surrounding the circle, positioned at the top, left, and right sides.

GE Healthcare 510(k) Premarket Notification Submission

Section 5: 510(k) Summary

Voluson E Series (Voluson E6 / Voluson E8 / Voluson E10)

{5}------------------------------------------------

Image /page/5/Picture/0 description: The image shows the General Electric (GE) logo. The logo consists of the letters 'GE' intertwined in a stylized script, surrounded by a circular frame. The frame has decorative flourishes resembling water droplets or stylized leaves. The logo is presented in a blue color.

510(k) Premarket Notification Submission

### 510(k) Summary K192159

In accordance with 21 CFR 807.92 the following summary of information is provided:

| Date:                        | Aug 7, 2019                                                                                                                                                                                                                                                                                                                                                  |
|------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Submitter:                   | GE Healthcare [GE Healthcare Austria GmbH & Co OG]<br>Tiefenbach 15<br>Zipf, Austria 4871                                                                                                                                                                                                                                                                    |
| Primary Contact Person:      | Bryan Behn<br>Regulatory Affairs Director<br>GE Healthcare<br>T:(262)247-5502<br>F:(414)918-8275                                                                                                                                                                                                                                                             |
| Secondary Contact Person:    | Roland Kuntscher<br>Regulatory Affairs Specialist<br>GE Healthcare Austria GmbH & Co OG<br>T:(+43)7682-3800-660<br>F:(+43)7682 3800-47                                                                                                                                                                                                                       |
| Device Trade Name:           | Voluson E6, Voluson E8, Voluson E10<br>Models: Voluson E6 / Voluson E8 / Voluson E10                                                                                                                                                                                                                                                                         |
| Common/Usual Name:           | Ultrasound system                                                                                                                                                                                                                                                                                                                                            |
| Classification Names:        | Class II                                                                                                                                                                                                                                                                                                                                                     |
| Product Code(s):             | IYN (primary), IYO, ITX (secondary)<br>Ultrasonic Pulsed Doppler Imaging System. 21CFR 892.1550, 90-IYN                                                                                                                                                                                                                                                      |
| Primary Predicate Device(s): | K181985 Voluson E6_E8_E10 Diagnostic Ultrasound System                                                                                                                                                                                                                                                                                                       |
| Product Code(s):             | IYN (primary), IYO, ITX (secondary)<br>Ultrasonic Pulsed Doppler Imaging System. 21CFR 892.1550, 90-IYN                                                                                                                                                                                                                                                      |
| Device Description:          | The systems are full-featured Track 3 ultrasound systems, primarily for<br>general radiology use and specialized for OB/GYN with particular<br>features for real-time 3D/4D acquisition. They consist of a mobile<br>console with keyboard control panel; color LCD/TFT touch panel,<br>color video display and optional image storage and printing devices. |

{6}------------------------------------------------

Image /page/6/Picture/0 description: The image shows the logo for General Electric (GE). The logo is a blue circle with the letters 'GE' in a stylized font in the center. The letters are surrounded by a swirling design that resembles water droplets or stylized leaves. The logo is simple and recognizable, and it is associated with a well-known and established company.

510(k) Premarket Notification Submission

including mechanical and electronic scanning transducers, which highly accurate real-time three-dimensional provide imaging supporting all standard acquisition modes. Voluson E10 is identical in hardware and software compared to the Voluson E8 and Voluson E6 with the exception of scan channels. Voluson E10 has more than Voluson E8 and E6. Voluson E10 also has additional hardware for the 4D electronic probes: eM6C and eM6C G2. The basic software is the same as the predicate and no additional software functions were added in this submission.

- The device is a general-purpose ultrasound system. Specific clinical Intended Use: applications remain the same as previously cleared: Fetal/OB: Abdominal (including GYN, pelvic and infertility monitoring/follicle development); Pediatric; Small Organ (breast, testes, thyroid etc.); Neonatal and Adult Cephalic; Cardiac (adult and pediatric); Musculo-Conventional and skeletal Superficial; Peripheral Vascular: Transvaginal (including GYN); Transrectal
- The Voluson E Series (Voluson E6 / Voluson E8 / Voluson E10) Technology: employs the same fundamental scientific technology as its predicate devices. The updated version of the Voluson E Series (Voluson E6 / Voluson E8 / Voluson E10) consists of improved hardware and improvements to existing software features compared to the predicate version.

Determination of Comparison to Predicates Substantial The proposed Voluson E Series (Voluson E6 / Voluson E8 / Voluson Equivalence: E10) is substantially equivalent to the predicate devices with regards to intended use, imaging capabilities, technological characteristics and safety and effectiveness.

- The systems are all intended for diagnostic ultrasound imaging and fluid flow analysis.
- The proposed Voluson E Series and predicate Voluson E Series systems have the same clinical intended use.
- The proposed Voluson E Series and predicate Voluson E Series ● systems have the same imaging modes.
- The proposed Voluson E Series and predicate Voluson E Series . systems transducers are equivalent. No new transducers were

{7}------------------------------------------------

Image /page/7/Picture/0 description: The image shows the logo for General Electric (GE). The logo is a blue circle with the letters "GE" in a stylized, cursive font. There are four white teardrop shapes surrounding the letters, one in each quadrant of the circle. The logo is simple and recognizable, and it is often used to represent the company's brand.

510(k) Premarket Notification Submission

added to the proposed system.

- . There is no change to the system indications for use.
- The systems are manufactured with materials which have been evaluated and found to be safe for the intended use of the device.
- . The systems have acoustic power levels which are below the applicable FDA limits.
- The proposed Voluson E Series and predicate Voluson E Series ● systems have similar capability in terms of performing measurements, capturing digital images, reviewing and reporting studies.
- The proposed Voluson E Series and predicate systems have ● been designed in compliance with approved electrical and physical safety standards.
- There proposed Voluson E Series and predicate Voluson E ● series Software Features are identical. Some minor improvements to the existing Software features have been implemented into the proposed system.

### Summary of Non-Clinical Tests:

The device has been evaluated for acoustic output, biocompatibility, cleaning and disinfection effectiveness as well as thermal, electrical, electromagnetic, and mechanical safety, and has been found to conform to applicable medical device safety standards. The Voluson E Series and its applications comply with voluntary standards:

- AAMI/ANSI ES60601-1. Medical Electrical Equipment Part . 1: General Requirements for Safety, 2005/(R)2012 And A1:2012
- IEC60601-1-2 Medical Electrical Equipment Part 1-2: . General Requirements for Safety - Collateral Standard: Electromagnetic Compatibility Requirements and Tests, 2014
- . IEC60601-2-37, Medical Electrical Equipment - Part 2-37: Particular Requirements for the Safety of Ultrasonic Medical Diagnostic and Monitoring Equipment, 2015
- ISO10993-1, Biological Evaluation of Medical Devices- Part 1: ● Evaluation and Testing- Third Edition, 2009
- ISO14971, Application of risk management to medical devices: ●

{8}------------------------------------------------

Image /page/8/Picture/0 description: The image shows the logo for General Electric (GE). The logo is a blue circle with the letters "GE" in a stylized script in the center. The circle is surrounded by a series of stylized water droplets or swirls. The blue color is a medium shade, and the overall design is clean and modern.

510(k) Premarket Notification Submission

Second edition 2007

- NEMA PS 3.1 3.20 (2016), Digital Imaging and . Communications in Medicine (DICOM) Set. (Radiology)
The following quality assurance measures are applied to the development of the system:

- Risk Analysis
- Requirements Reviews
- Design Reviews
- Testing on unit level (Module verification) ●
- Integration testing (System verification)
- Performance testing (Verification)
- Safety testing (Verification) ●
- Final Acceptance Testing (Validation) ●

Transducer materials and other patient contact materials are biocompatible.

#### Summary of Clinical Tests:

The subject of this premarket submission, Voluson E Series (Voluson E6 / Voluson E8 / Voluson E10), did not require clinical studies to support substantial equivalence.

- GE Healthcare considers the Voluson E Series (Voluson E6 / Voluson Conclusion: E8 / Voluson E10) to be as safe, as effective, and performance is substantially equivalent to the predicate device(s).

---

**Source:** [https://fda-staging.innolitics.com/device/K192159](https://fda-staging.innolitics.com/device/K192159)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
