Zimmer Biomet Universal Navigation System

K192133 · Zimmer Biomet Spine, Inc. · OLO · Oct 29, 2019 · Neurology

Device Facts

Record IDK192133
Device NameZimmer Biomet Universal Navigation System
ApplicantZimmer Biomet Spine, Inc.
Product CodeOLO · Neurology
Decision DateOct 29, 2019
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 882.4560
Device ClassClass 2

Indications for Use

The Zimmer Biomet Universal Navigation System is indicated for use during the preparation and insertion of Zimmer Biomet screws during spinal surgery to assist the surgeon in precisely locating anatomical structures in either open or minimally invasive procedures. The universal adaptors are specifically designed for use with the Zimmer Biomet ROSA One Spine application, which is indicated for providing spatial positioning and orientation of instrument holders or tool guides based upon an intraoperative plan developed with three dimensional imaging software provided that the required fiducial markers and rigid patient anatomy can be identified on 3D CT scans. The ROSA One Spine application is intended to assist in the placement of pedicle screws in vertebrae with a posterior approach in the thoracolumbar region.

Device Story

The Zimmer Biomet Universal Navigation System consists of universal adaptors designed to interface existing surgical instruments (Vitality, Pathfinder NXT, Polaris) with the ROSA One Spine navigation system. The system utilizes 3D CT scan data to facilitate intraoperative spatial positioning and orientation of tool guides. Surgeons use the system to assist in the precise preparation and insertion of pedicle screws during spinal surgery. The device operates by tracking instrument position relative to patient anatomy, allowing for navigation-guided placement. It is intended for use in clinical settings by surgeons. The system benefits patients by providing navigation assistance for screw placement, potentially increasing accuracy in spinal procedures.

Clinical Evidence

No clinical data was needed. Performance was established through bench testing, specifically accuracy testing of the navigation instruments conducted in accordance with ASTM F2554-18 Standard Practice for Measurement of Positional Accuracy of Computer Assisted Surgical Systems.

Technological Characteristics

The system comprises universal adaptors for surgical instrumentation. It utilizes optical or mechanical navigation principles integrated with the ROSA One Spine platform. Accuracy testing follows ASTM F2554-18. The system is designed for use with 3D CT imaging data. Connectivity is provided via the ROSA One Spine navigation architecture.

Indications for Use

Indicated for patients undergoing spinal surgery requiring pedicle screw placement in the thoracolumbar region via a posterior approach. Used to assist surgeons in locating anatomical structures during open or minimally invasive procedures.

Regulatory Classification

Identification

A stereotaxic instrument is a device consisting of a rigid frame with a calibrated guide mechanism for precisely positioning probes or other devices within a patient's brain, spinal cord, or other part of the nervous system.

Predicate Devices

Reference Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Zimmer Biomet Spine, Inc. Alex Pawlowski Regulatory Affairs Senior Specialist 10225 Westmoor Dr. Westminster, Colorado 80021 Re: K192133 Trade/Device Name: Zimmer Biomet Universal Navigation System Regulation Number: 21 CFR 882.4560 Regulation Name: Stereotaxic instrument Regulatory Class: Class II Product Code: OLO Dated: August 6, 2019 Received: August 7, 2019 Dear Alex Pawlowski: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database located at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's October 29, 2019 {1}------------------------------------------------ requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803) for devices or postmarketing safety reporting (21 CFR 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reportingcombination-products); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-device-safety/medical-device-reportingmdr-how-report-medical-device-problems. For comprehensive regulatory information about mediation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medicaldevices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-device-advice-comprehensive-regulatoryassistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100). Sincerely, For, Shumaya Ali, M.P.H. Assistant Director DHT6C: Division of Restorative, Repair, and Trauma Devices OHT6: Office of Orthopedic Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ # Indications for Use 510(k) Number (if known) K192133 Device Name Zimmer Biomet Universal Navigation System #### Indications for Use (Describe) The Zimmer Biomet Universal Navigation System is indicated for use during the preparation and insertion of Zimmer Biomet screws during spinal surgery to assist the surgeon in precisely locating anatomical structures in either open or minimally invasive procedures. The universal adaptors are specifically designed for use with the Zimmer Biomet ROSA One System, which is indicated for providing spatial positioning and orientation of instrument holders or tool guides based upon an intraoperative plan developed with three dimensional imaging software provided that the required fiducial markers and rigid patient anatomy can be identified on 3D CT scans. The ROSA One Spine System is intended for the placement of pedicle screws in vertebrae with a posterior approach in the thoracolumbar region. Type of Use (*Select one or both, as applicable*) | <span> <b>☑</b> Prescription Use (Part 21 CFR 801 Subpart D) </span> | |----------------------------------------------------------------------------| | <span> <b>☐</b> Over-The-Counter Use (21 CFR 801 Subpart C) </span> | ### CONTINUE ON A SEPARATE PAGE IF NEEDED. This section applies only to requirements of the Paperwork Reduction Act of 1995. #### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.* The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: > Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number." {3}------------------------------------------------ ## 510(k) Summary This summary of 510(k) safety and effectiveness information is being submitted in accordance with the requirements of 21 CFR § 807.92. | Preparation Date | August 6, 2019 | |---------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Applicant/Sponsor | Zimmer Biomet Spine, Inc.<br>10225 Westmoor Dr.<br>Westminster, CO 80021 | | Contact Person | Alex Pawlowski<br>Regulatory Affairs Sr. Specialist<br>Phone: 303-533-1062 | | | Ted Kuhn<br>Regulatory Affairs Associate Director<br>Phone: 720-469-5055 | | Trade Name | Zimmer Biomet Universal Navigation System | | Common Name | Stereotaxic Instrument | | Device Class | Class II | | Classification Name | OLO - Orthopedic Stereotaxic Instrument (21 CFR 882.4560) | | Device Panel | Orthopedic | | Primary Predicate | K122211 Synthes Navigable Pedicle Preparation Instruments | | Secondary Predicate | K182848 ROSA One Spine Navigation System | | Reference Devices | K133444 Medtronic StealthStation<br>K132884 Pathfinder NXT Spine System<br>K151974 Polaris Spinal Fixation System<br>K183550 Vitality Spinal Fixation System, Vitality MIS | {4}------------------------------------------------ ### Device Description & Technological Characteristics: The Zimmer Biomet Universal Navigation System includes Universal Adaptors that are intended to be used with instrumentation from Vitality Spinal Fixation System (including Vitality MIS), Pathfinder NXT Minimally Invasive Pedicle Screw System, and Polaris Spinal Fixation System (including Cypher MIS Screw System) to facilitate preparation and insertion of Zimmer Biomet screws using navigation. ### Intended Use / Indications for Use: The Zimmer Biomet Universal Navigation System is indicated for use during the preparation and insertion of Zimmer Biomet screws during spinal surgery to assist the surgeon in precisely locating anatomical structures in either open or minimally invasive procedures. The universal adaptors are specifically designed for use with the Zimmer Biomet ROSA One Spine application, which is indicated for providing spatial positioning and orientation of instrument holders or tool guides based upon an intraoperative plan developed with three dimensional imaging software provided that the required fiducial markers and rigid patient anatomy can be identified on 3D CT scans. The ROSA One Spine application is intended to assist in the placement of pedicle screws in vertebrae with a posterior approach in the thoracolumbar region. #### Summary of Technological Characteristics: The technological characteristics of the subject Zimmer Biomet Universal Navigation System components remain the same as, or similar to, the predicates in regards to intended use, indications for use, design, manufacturing methods, materials, and operational principles. The purpose of this submission is to seek clearance to introduce new adaptors designed to interface with the already-cleared surgical navigation system, ROSA One Spine application, and alreadycleared pedicle screw preparation and insertion instruments to facilitate preparation and insertion of Zimmer Biomet screws using navigation. ### Summary of Performance Data: Validation activities are used to confirm the instruments meet performance requirements, providing assurance of device performance for their intended use, similar to predicate systems. Accuracy testing of the Zimmer Biomet Universal Navigation System Instruments was performed in accordance ASTM F2554-18 Standard Practice For Measurement of Positional Accuracy of Computer Assisted Surgical Systems. Clinical data was not needed for the Zimmer Biomet Universal Navigation System. ### Substantial Equivalence Conclusion: The Zimmer Biomet Universal Navigation System is substantially equivalent to the predicate system in regards to intended use, indications for use, fundamental technology including design, materials, manufacturing methods, materials and operational principles. Furthermore, validation testing and other supporting information sufficiently demonstrate the substantial equivalence of the subject components. Based on this information, the subject device does not raise any new issues regarding the safety or efficacy when compared to its predicates.
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...