K182819 · Gcmedica Enterprise Ltd.(Wuxi) · LHI · Dec 2, 2019 · General Hospital
Device Facts
Record ID
K182819
Device Name
Decanting Device
Applicant
Gcmedica Enterprise Ltd.(Wuxi)
Product Code
LHI · General Hospital
Decision Date
Dec 2, 2019
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 880.5440
Device Class
Class 2
Indications for Use
GCMEDICA Mini Transfer Device, GCMEDICA Vial Transfer Device: Intended for the aseptic dispensing of solutions from IV containers. For use in transferring IV fluids/medication from a vial to an IV fluid administration device. GCMEDICA Bag Transfer Device, GCMEDICA Clear Bag Transfer Device: Intended for the aseptic dispensing of solutions from IV containers. For use in transferring IV fluids/medication from a bag to an IV fluid administration device.
Device Story
Decanting devices facilitate sterile fluid path creation for aseptic transfer of IV fluids/medication from containers (vials/bags) to administration sets. Models include spike/cap or protective cap/needle tip/cover/stick configurations. Operated by clinicians in clinical settings; device is inserted into container rubber opening or port; user tilts device to initiate flow. Air ventilation holes ensure pressure equalization. Single-use, sterile, disposable. Benefits include reduced contamination risk during fluid transfer.
Clinical Evidence
No clinical data. Bench testing only: biocompatibility (ISO 10993-4, -5, -10, -11), performance testing (appearance, dimension, unimpeded performance, sealing, connection strength, penetration force, fluid flow, leakage), particulate matter (USP <788>), and ethylene oxide sterilization validation (ISO 11135-1:2014). All results passed.
Technological Characteristics
Materials: ABS, PE, K Resin. Principle: Mechanical spike/stick for fluid path creation. Dimensions: 3, 6, and 9 inches. Sterilization: Ethylene oxide (ISO 11135-1:2014). Single-use, non-powered, manual operation.
Indications for Use
Indicated for aseptic dispensing of IV solutions and transfer of fluids/medication from vials or bags to IV administration devices.
Regulatory Classification
Identification
An intravascular administration set is a device used to administer fluids from a container to a patient's vascular system through a needle or catheter inserted into a vein. The device may include the needle or catheter, tubing, a flow regulator, a drip chamber, an infusion line filter, an I.V. set stopcock, fluid delivery tubing, connectors between parts of the set, a side tube with a cap to serve as an injection site, and a hollow spike to penetrate and connect the tubing to an I.V. bag or other infusion fluid container.
Special Controls
*Classification.* Class II (special controls). The special control for pharmacy compounding systems within this classification is the FDA guidance document entitled “Class II Special Controls Guidance Document: Pharmacy Compounding Systems; Final Guidance for Industry and FDA Reviewers.” Pharmacy compounding systems classified within the intravascular administration set are exempt from the premarket notification procedures in subpart E of this part and subject to the limitations in § 880.9.
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image shows the logo of the U.S. Food and Drug Administration (FDA). The logo consists of two parts: a symbol on the left and the FDA name on the right. The symbol on the left is a stylized image of a human figure, while the FDA name on the right is written in blue letters. The words "U.S. FOOD & DRUG ADMINISTRATION" are written in a clear, sans-serif font.
GCMEDICA ENTERPRISE LTD., (WUXI) % Ethan Liu QA Specialist Shanghai Thinkwell Consulting Co., Ltd Xinling Road, 211/6F Shanghai, 201100 China
Re: K182819
Trade/Device Name: GCMEDICA Mini Transfer Device GCMEDICA Vial Transfer Device GCMEDICA Bag Transfer Device GCMEDICA Clear Bag Transfer Device Regulation Number: 21 CFR 880.5440 Regulation Name: Intravascular Administration Set Regulatory Class: Class II Product Code: LHI Dated: October 21, 2019 Received: October 29, 2019
Dear Ethan Liu:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database located at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{1}------------------------------------------------
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803) for devices or postmarketing safety reporting (21 CFR 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reportingcombination-products); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-device-safety/medical-device-reportingmdr-how-report-medical-device-problems.
For comprehensive regulatory information about mediation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medicaldevices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-device-advice-comprehensive-regulatoryassistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).
Sincerely.
for Geeta Pamidimukkala Acting Assistant Director DHT3C: Division of Drug Delivery and General Hospital Devices, and Human Factors OHT3: Office of Gastrorenal, ObGyn, General Hospital and Urology Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration
## Indications for Use
510(k) Number (if known) K182819
#### Device Name
GCMEDICA Mini Transfer Device, GCMEDICA Vial Transfer Device, GCMEDICA Bag Transfer Device, GCMEDICA Clear Bag Transfer Device
#### Indications for Use (Describe)
GCMEDICA Mini Transfer Device, GCMEDICA Vial Transfer Device: Intended for the aseptic dispensing of solutions from IV containers. For use in transferring IV fluids/medication from a vial to an IV fluid administration device. GCMEDICA Bag Transfer Device, GCMEDICA Clear Bag Transfer Device: Intended for the aseptic dispensing of solutions from IV containers. For use in transferring IV fluids/medication from a bag to an IV fluid administration device.
| Type of Use (Select one or both, as applicable) | |
|--------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------|
| <span> <span style="font-family: DejaVu Sans, sans-serif;">❌</span> Prescription Use (Part 21 CFR 801 Subpart D) </span> | <span> <span style="font-family: DejaVu Sans, sans-serif;">☐</span> Over-The-Counter Use (21 CFR 801 Subpart C) </span> |
CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
***DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.***
The burden time for this collection of information is estimated to average 79 hours per response, including the
time to review instructions, search existing data sources, gather and maintain the data needed and complete
and review the collection of information. Send comments regarding this burden estimate or any other aspect
of this information collection, including suggestions for reducing this burden, to:
Department of Health and Human Services
Food and Drug Administration
Office of Chief Information Officer
Paperwork Reduction Act (PRA) Staff
*PRAStaff@fda.hhs.gov*
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of
information unless it displays a currently valid OMB number."
{3}------------------------------------------------
Image /page/3/Picture/0 description: The image shows the logo for GCiMEDICA. The logo is blue and features the company name in a stylized font. Below the name is the text "SINCE 1998".
Decanting Device
# 510(k) Summary (K182819)
This summary of 510(k) safety and effectiveness information is being submitted in accordance with requirements of 21 CFR Part 807.92.
# 5.1 Submitter
| Submitted by: | GCMEDICA ENTERPRISE LTD.,(WUXI)<br>Loujin Industrial Park,Shuofang,Wuxi,Jiangsu,PRC |
|-----------------|---------------------------------------------------------------------------------------------|
| Contact Person: | Ethan Liu<br>Phone: 0086-15216699240<br>Fax: 0086-21-60732022<br>Email: xtdeepwater@126.com |
| Date Prepared: | Nov. 25, 2019 |
## 5.2 Device
| Trade Name | | |
|--------------------|-----------------------------------|------------------------------------|
| | GC0652DD | GCMEDICA Mini Transfer Device |
| | GC0653DD | GCMEDICA Vial Transfer Device |
| | GC0654DD | GCMEDICA Bag Transfer Device |
| | GC0654DT | GCMEDICA Clear Bag Transfer Device |
| Common Name: | Decanting Device | |
| Regulation Number: | 880.5440 | |
| Regulation Name: | Intravascular administration set. | |
| Regulatory Class: | Class II | |
| Product Code: | LHI | |
{4}------------------------------------------------
Image /page/4/Picture/0 description: The image shows the logo for GCiMEDICA. The logo is in blue and features the company name in a stylized font. Below the name is the text "SINCE 1998".
Decanting Device
| Product Code Name | Set, I.V. Fluid Transfer |
|-------------------|--------------------------|
|-------------------|--------------------------|
## 5.3 Predicate Device
| Trade Name: | Medline Vial Decanter (K111577) |
|--------------------|-----------------------------------|
| Common Name: | Decanting device |
| Regulation Number: | 880.5440 |
| Regulation Name: | Intravascular administration set. |
| Regulatory Class: | Class II |
| Product Code: | LHI |
| Product Code Name: | Set, I.V. Fluid Transfer |
## 5.4 Device Description
The Decanting Device is provided as sterile and is intended for use in a single procedure only. There are four proposed models: GC0652DD, GC 0653DD and GC0654DD and GC0654 DT. Model GC0652DD, GC0654DD and GC0654 DT consist of spike and cap for spike. Model GC0653DD consists of Protective Cap, Needle Tip, Cover and stick.
Through the use of a spike/stick, facilitates creation of a sterile fluid path. Decanting device help ensure an aseptic transfer or removal of fluids/medication from flexible and rigid containers.
For models GC0653DD and GC0652DD, insert the decanter spike/stick by piercing the rubber opening of the glass vial. Tilt the decanting device body until desired flow is reached, ensuring the spike/stick air ventilation holes remain inside the glass vial.
### 5.5 Indication for Use:
GCMEDICA Mini Transfer Device, GCMEDICA Vial Transfer Device: Intended for the aseptic dispensing of solutions from IV containers. For use in transferring IV fluids/medication from a vial to an IV fluid administration device.
Bag Transfer Device, GCMEDICA Clear Bag Transfer Device: GCMEDICA
{5}------------------------------------------------
Image /page/5/Picture/0 description: The image shows the logo for GC Medica. The logo is blue and features the text "GC Medica" in a stylized font. Below the text is the phrase "Since 1998".
Intended for the aseptic dispensing of solutions from IV containers. For use in transferring IV fluids/medication from a bag to an IV fluid administration device.
| Item | Proposed Device<br>Common name: Decanting Device<br>Submitter:GCMEDICA ENTERPRISE<br>LTD.,(WUXI) | Predicate device<br>(K111577 )<br>Trade/Device<br>name: Medline<br>Vial Decanter<br>Submitter:<br>Medline<br>Industries<br>Incorporated | Comment |
|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Model | Image: GC0652DD<br>Image: GC0653DD,<br>Image: GC0654DD<br>Image: GC0654 DT | Image: DYNJDEC06 | Different.<br>GCMEDICA has<br>four models while<br>Medline has only<br>one model.<br>GC0653DD is same<br>as DYNJDEC06.<br>The other three<br>models have similar<br>configurations.<br>Performance testing<br>was conducted to<br>demonstrate any<br>difference will not<br>raise questions<br>regarding its safety<br>and effectiveness. |
| Indication for Use | GCMEDICA Mini Transfer Device,<br>GCMEDICA Vial Transfer Device:<br>Intended for the aseptic dispensing of<br>solutions from IV containers. For use in | Decanting device<br>intended for the<br>aseptic dispensing<br>of solutions from | |
| Item | Proposed Device<br>Common name: Decanting Device<br>Submitter:GCMEDICA ENTERPRISE<br>LTD.,(WUXI) | Predicate device<br>(K111577 )<br>Trade/Device<br>name: Medline<br>Vial Decanter<br>Submitter:<br>Medline<br>Industries<br>Incorporated | Comment |
| | transferring IV fluids/medication from a vial<br>to an IV fluid administration device.<br><br>GCMEDICA Bag Transfer Device,<br>GCMEDICA Clear Bag Transfer Device:<br>Intended for the aseptic dispensing of<br>solutions from IV containers. For use in<br>transferring IV fluids/medication from a bag<br>to an IV fluid administration device. | IV containers. For<br>use in transferring<br>IV<br>fluids/medication<br>from a vial to an<br>IV fluid<br>administration<br>device. | |
| Configur<br>ation | Model GC0652DD, GC0654DD and<br>GC0654 DT consist of spike and cap for<br>spike. Model GC0653DD consists of<br>Protective Cap, Needle Tip, Cover and stick. | Model<br>DYNJDEC06<br>consists of<br>Protective Cap,<br>Needle Tip, Cover<br>and stick. | Model GC0653DD<br>is same as Model<br>DYNJDEC06. The<br>other three models<br>have similar<br>configurations. The<br>difference will not<br>raise any question<br>regarding its safety<br>and effectiveness. |
| Length | Model GC0652DD: 3inch;<br>Model GC0653DD: 6inch;<br>Model GC0654DD: 9inch;<br>Model GC0654DT: 9inch. | DYNJDEC06:<br>6inch; | Model GC0653DD<br>is same as Model<br>DYNJDEC06, the<br>length is 6 inch,<br>while the other three<br>models' length is 3<br>inch and 9 inch. We<br>had performed |
| Item | Proposed Device<br>Common name: Decanting Device<br>Submitter:GCMEDICA ENTERPRISE<br>LTD.,(WUXI) | Predicate device<br>(K111577 )<br>Trade/Device<br>name: Medline<br>Vial Decanter<br>Submitter:<br>Medline<br>Industries<br>Incorporated | Comment |
| | | | unimpeded<br>performance,<br>sealing<br>performance,<br>connecting strength,<br>fluid flow and<br>leakage for all<br>proposed models,<br>the length difference<br>will not raise any<br>difference regarding<br>its safety and<br>effectiveness. |
| Material | GC0652DD, GC0653DD, GC0654DD:<br>ABS, PE;<br>GC0654DT: K Resin, PE. | DYNJDEC06:<br>ABS, PE; | Model GC0652DD,<br>GC0653DD,<br>GC0654DD are<br>same as Model<br>DYNJDEC06.<br>Biocompatibility<br>testing was<br>performed per ISO<br>10993-1. The<br>difference will not<br>raise any questions<br>regarding its safety<br>and effectiveness. |
# 5.6 Substantial Equivalence and Technological Characteristics
{6}------------------------------------------------
Image /page/6/Picture/0 description: The image shows the logo for GCiMEDICA. The logo is blue and features the company name in a stylized font. Below the company name is the text "SINCE 1998".
{7}------------------------------------------------
Image /page/7/Picture/0 description: The image shows the logo for GCiMEDICA. The logo is in blue and features the company name in a stylized font. Below the company name, it says "SINCE 1998".
Decanting Device
{8}------------------------------------------------
Image /page/8/Picture/0 description: The image shows the logo for GCI Medica. The logo is blue and features the text "GCI Medica" in a stylized font. Below the text is a blue swoosh and the text "Since 1998".
## 5.7 Substantial Equivalence
Medline Vial Decanter ( Medline Industries Incorporated, K111577) is used as predicate device compared to proposed device Decanting Device manufactured by GCMEDICA ENTERPRISE LTD.,(WUXI).
## 5.8 Performance Data
## 5.8.1 Biocompatibility Testing
The biocompatibility evaluation for this device was conducted in accordance with the International Standard ISO 10993-1 Fourth Edition 2009-10-15, Biological Evaluation Of Medical Devices - Part 1: Evaluation And Testing Within A Risk Management Process [Including: Technical Corrigendum 1 (2010)], as recognized by FDA.
The following Biocompatibility tests were conducted by GC0654DD and GC0654DT. The results of all testing were passing.
| Biocompatibility Test | Standards |
|------------------------------------------------------------------------------------------------------|-------------------|
| In Vitro Cytotoxicity Test | ISO 10993-5:2009 |
| Skin Sensitization Test:<br>Guinea Pig Maximization Test (0.9% Sodium<br>Chloride Injection Extract) | ISO 10993-10:2010 |
| Skin Sensitization Test:<br>Guinea Pig Maximization Test (Sesame oil Extract) | ISO 10993-10:2010 |
| Intracutaneous Reactivity Test (0.9% Sodium<br>Chloride Injection Extract and Sesame Oil Extract) | ISO 10993-10:2010 |
| Acute Systemic Toxicity (0.9% Sodium Chloride<br>Injection Extract, Intravenous) | ISO 10993-11:2017 |
| Acute Systemic Toxicity (Sesame Oil Extract,<br>Intraperitoneal) | ISO 10993-11:2017 |
| Pyrogen Test (0.9% Sodium Chloride Injection<br>Extract, Rabbit) | ISO 10993-11:2017 |
{9}------------------------------------------------
Image /page/9/Picture/0 description: The image shows the logo for GC Medica. The logo is blue and features the text "GC Medica" in a stylized font. Below the text is a blue swoosh and the text "Since 1998".
Decanting Device
| Biocompatibility Test | Standards |
|----------------------------------------------------|------------------|
| In Vitro Hemocompatibility Testing (Rabbit blood). | ISO 10993-4:2017 |
#### 5.8.2 Performance Testing
The following bench tests were performed on Decanting device according to internal standards: Appearance, dimension, unimpeded performance, sealing performance, connection strength, penetration force, fluid flow and leakage. Testing was also conducted according USP <788> Particulate Matter in Injections. Sterilization validation was performed according to ISO 11135-1:2014 Sterilization of health-care products - Ethylene oxide - Requirements for the development, validation and routine control of a sterilization process for medical devices. The results of all testing were passing.
## 5.9 Clinical Test Conclusion
No Clinical Study is included in this submission.
## 5.10 Conclusion
In accordance with the Federal Food, Drug and Cosmetic Act, 21 CFR Part 807, Based on the information provided in this premarket notification, GCMEDICA ENTERPRISE LTD., (WUXI) has demonstrated that proposed device Decanting Device is substantially equivalent to Medline Industries Incorporated's currently marketed Medline Vial Decanter (K111577).
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.