Medline ReNewal Reprocessed Smith & Nephew Jet-X External Fixation Devices
K180580 · Surgical Instrument Service and Savings, Inc. · KTT · Jul 27, 2018 · Orthopedic
Device Facts
Record ID
K180580
Device Name
Medline ReNewal Reprocessed Smith & Nephew Jet-X External Fixation Devices
Applicant
Surgical Instrument Service and Savings, Inc.
Product Code
KTT · Orthopedic
Decision Date
Jul 27, 2018
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 888.3030
Device Class
Class 2
Attributes
Therapeutic, Pediatric
Indications for Use
Medline ReNewal Reprocessed Smith & Nephew Jet-X External Fixation devices are intended to be used on adults or pediatric patients as required and are intended to be used for fracture fixation (open and closed): post-traumatic joint contracture which has resulted in loss of range of motion; fractures and disease which generally may result in joint contractures or loss of range of motion and fractures requiring distraction; pseudoarthrosis or non-union of long bones; limb lengthening by epiphyseal or metaphyseal distraction of bony or soft tissue deformity; correction of segmental bony or soft tissue defects; joint arthrodesis; and management of comminuted intractures of the distal radius. Medline ReNewal Reprocessed Smith & Nephew Jet-X External Fixation devices are for single use only.
Device Story
Reprocessed orthopedic external fixation system; includes clamps, posts, and bars. Used for fracture management, joint contracture correction, and limb lengthening. Operates by providing rigid skeletal stabilization. Used in clinical/surgical settings by physicians. Reprocessing involves cleaning and sterilization of OEM devices; no changes to design, materials, or intended use. Provides mechanical stability to bone segments to facilitate healing.
Clinical Evidence
Bench testing only. Evaluated via functional performance studies: simulated use, artificial soiling, structural integrity, carbon rod stiffness (4-point bend test, pre/post-conditioning), cyclical axial compression/tension bending, disassembly/reassembly (pre/post-sterilization), and cleaning efficacy (residual protein/carbohydrate).
Technological Characteristics
Materials: stainless steel, titanium, carbon fiber, aluminum. Principle: mechanical external fixation. Form factor: various clamps, bars, and posts. Sterilization: reprocessed/re-sterilized. No software or energy source.
Indications for Use
Indicated for adults and pediatric patients requiring fracture fixation (open/closed), management of joint contractures, fractures requiring distraction, pseudoarthrosis, non-union of long bones, limb lengthening, correction of bony/soft tissue deformities or defects, joint arthrodesis, and comminuted intra-articular distal radius fractures.
Regulatory Classification
Identification
Single/multiple component metallic bone fixation appliances and accessories are devices intended to be implanted consisting of one or more metallic components and their metallic fasteners. The devices contain a plate, a nail/plate combination, or a blade/plate combination that are made of alloys, such as cobalt-chromium-molybdenum, stainless steel, and titanium, that are intended to be held in position with fasteners, such as screws and nails, or bolts, nuts, and washers. These devices are used for fixation of fractures of the proximal or distal end of long bones, such as intracapsular, intertrochanteric, intercervical, supracondylar, or condylar fractures of the femur; for fusion of a joint; or for surgical procedures that involve cutting a bone. The devices may be implanted or attached through the skin so that a pulling force (traction) may be applied to the skeletal system.
Predicate Devices
Smith & Nephew Jet-X Bar System Clamps, Bars and Posts - MR Conditional (K072212)
Submission Summary (Full Text)
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image contains the logo of the U.S. Food and Drug Administration (FDA). On the left is the Department of Health and Human Services logo. To the right of that is the FDA logo, which is a blue square with the letters "FDA" in white. To the right of the blue square is the text "U.S. FOOD & DRUG ADMINISTRATION" in blue.
Surgical Instrument Service and Savings Inc Stephanie Mays Regulatory Specialist, Quality Assurance/Regulatory Affairs (dba Medline ReNewal) 1500 NE Hemlock Ave Redmond, Oregon 97756
July 27. 2018
# Re: K180580
Trade/Device Name: Medline ReNewal Reprocessed Smith & Nephew Jet-X External Fixation Devices Regulation Number: 21 CFR 888.3030 Regulation Name: Single/Multiple Component Metallic Bone Fixation Appliances And Accessories Regulatory Class: Class II Product Code: KTT Dated: June 23, 2018 Received: June 25, 2018
# Dear Stephanie Mays:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820);
{1}------------------------------------------------
and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm.
For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/) and CDRH Learn (http://www.fda.gov/Training/CDRHLearn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (http://www.fda.gov/DICE) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).
Sincerely,
Mark N. Melkerson -S
Mark N. Melkerson Director Division of Orthopedic Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure: Reprocessed List
{2}------------------------------------------------
| Catalog No. | Description |
|-------------|----------------------------------------------------|
| 7106-2001 | JET-X Bar to pin clamp 10.5mm bar to 5mm pin |
| 7106-2002 | JET-X Bar to bar clamp 10.5mm bar |
| 7106-2004 | JET-X Bar to ring clamp |
| 7106-2005 | JET-X Multiple pin clamp 10.5mm bar to 5mm pin |
| 7107-0343 | JET-X Frame Stabilizer Tool |
| 7106-4004 | JET-X Bar to ring clamp |
| 7106-4005 | JET-X Bar Multiple Pin Clamp |
| 7106-2009 | JET-X Freedom clamp 6mm bar to 5mm pin |
| 7106-2010 | JET-X Mini bar 10.5mm to 4mm pin clamp |
| 7106-2011 | JET-X Mini bar 6mm to 4mm pin clamp |
| 7106-2012 | JET-X Mini Bar to Pin Clamp 6mm to 6mm |
| 7106-2015 | JET-X Mini multiple pin clamp |
| 7106-2016 | JET-X Mini Double pin clamp with ball joint |
| 7106-2019 | JET-X Mini bar 6mm to 10.5mm bar clamp |
| 7106-2721 | JET-X Ankle Clamp |
| 7106-2722 | JET-X Freedom Bar to Ring Clamp 10.5mm Bar to Ring |
| 7106-4001 | JET-X Freedom clamp 10.5mm bar to 5mm pin |
| 7106-4002 | JET-X Freedom clamp 10.5mm bar to 10.5mm bar |
| 7106-4009 | JET-X Bar to pin clamp |
| 7106-4010 | JET-X Mini freedom clamp 10.5mm bar to 4mm pin |
| 7106-4011 | JET-X Mini freedom clamp 6mm bar to 4mm pin |
| 7106-4012 | JET-X Mini freedom clamp 6mm bar to 6mm pin |
| 7106-4015 | JET-X Mini multiple pin clamp |
| 7106-4016 | JET-X Mini double pin clamp with ball joint |
| 7106-4019 | JET-X Freedom clamp 10.5mm bar to 6mm pin |
| 7106-7372 | JET-X Quick clamp 10.5mm bar to 5mm pin |
| 7106-7374 | JET-X Quick clamp 10.5mm bar to 10.5mm pin |
| 7106-7375 | JET-X 4 Hole Pin Clamp |
| 7106-7376 | JET-X 6 Hole Pin Clamp |
| 7106-7371 | JET-X Mini Quick clamp 10.5mm to 4mm |
| 7106-7373 | JET-X Mini Quick clamp 10.5mm bar to 6mm pin |
| 7106-7377 | JET-X Quick Clamp 6mm to 4mm |
| 7106-7378 | JET-X Quick Clamp 6mm to 6mm |
| 7106-7380 | JET-X Quick Clamp 6mm to 5mm |
| 7106-2160 | JET-X L-Bar 10.5mm |
| 7106-2180 | JET-X V-Bar 10.5mm |
| 7106-2100 | JET-X Bar 10.5mm x 100mm |
| 7106-2150 | JET-X Bar 10.5mm x 150mm |
| 7106-2200 | JET-X Bar 10.5mm x 200mm |
| 7106-2250 | JET-X Bar 10.5mm x 250mm |
| 7106-2300 | JET-X Bar 10.5mm x 300mm |
| 7106-2350 | JET-X Bar 10.5mm x 350mm |
| 7106-2400 | JET-X Bar 10.5mm x 400mm |
| 7106-2500 | JET-X Bar 10.5mm x 500mm |
| 7106-2600 | JET-X Bar 10.5mm x 600mm |
| 7106-5050 | JET-X Mini Composite Bar 6mm x 50mm |
| 7106-5075 | JET-X Composite Bar 6mm x 75mm |
| 7106-5110 | JET-X Composite Bar 6mm x 110mm |
| 7106-5150 | JET-X Composite Bar 6mm x 150mm |
| 7106-5185 | JET-X Composite Bar 6mm x 185mm |
| 7106-5225 | JET-X Composite Bar 6mm x 225mm |
| 7106-5180 | JET-X Composite V-Bar 6mm |
| 7106-5226 | JET-X Off-Set Bar 6mm |
| 7106-7379 | JET-X Straight Post |
| 7106-7381 | JET-X 30° Angled Post |
| 7106-7382 | JET-X Freedom Post |
{3}------------------------------------------------
{4}------------------------------------------------
# Indications for Use
510(k) Number (if known) K180580
#### Device Name
Medline ReNewal Reprocessed Smith & Nephew Jet-X External Fixation Systems
#### Indications for Use (Describe)
Medline ReNewal Reprocessed Smith & Nephew Jet-X External Fixation devices are intended to be used on adults or pediatric patients as required and are intended to be used for fracture fixation (open and closed): post-traumatic joint contracture which has resulted in loss of range of motion; fractures and disease which generally may result in joint contractures or loss of range of motion and fractures requiring distraction; pseudoarthrosis or non-union of long bones; limb lengthening by epiphyseal or metaphyseal distraction of bony or soft tissue deformity; correction of segmental bony or soft tissue defects; joint arthrodesis; and management of comminuted intractures of the distal radius. Medline ReNewal Reprocessed Smith & Nephew Jet-X External Fixation devices are for single use only.
Type of Use (Select one or both, as applicable)
| <span style="font-family: sans-serif;"> <input checked="true" type="checkbox"/> Prescription Use (Part 21 CFR 801 Subpart D) </span> |
|------------------------------------------------------------------------------------------------------------------------------------------------|
| <span style="font-family: sans-serif;"> <input type="checkbox"/> Over-The-Counter Use (21 CFR 801 Subpart C) </span> |
CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
{5}------------------------------------------------
Image /page/5/Picture/1 description: The image contains two logos side by side. The logo on the left is for Medline, and it features the word "MEDLINE" in a sans-serif font, with a star-like symbol above it, all in white against a blue background. The logo on the right is for ReNewal Full Circle Reprocessing, with "ReNewal" in green and blue, and "Full Circle Reprocessing" in a smaller font below it.
Traditional 510(k) Notification Medline ReNewal Reprocessed Smith & Nephew External Fixation Devices
# 5.0 510(k) Summary
This 510(k) summary of safety and effectiveness information is prepared in accordance with 21 CFR § 807.92.
| Submitter/<br>Owner | Surgical Instrument Service and Savings (dba Medline ReNewal)<br>1500 NE Hemlock Ave.<br>Redmond, OR 97756 | | |
|--------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------|--|
| Prepared<br>by/Contact<br>Name | Stephanie Boyle Mays<br>Regulatory Affairs Specialist, Quality Assurance/Regulatory Affairs<br>P: 541-516-4205 • F: 541-923-3375 • E:smays@medline.com | | |
| Date Prepared | February 28, 2108 | | |
| Device Name<br>and<br>Classification | Proprietary/Trade<br>Name: | Medline ReNewal Reprocessed Smith & Nephew Jet-X<br>External Fixation Systems Devices | |
| | Regulatory<br>Name/Reference: | Smooth or threaded metallic bone fixation fastener,<br>21 CFR § 888.3040 | |
| | Regulatory Class: | Class II | |
| | Product Code: | KTT | |
| | Panel: | Orthopedic | |
| | 510(k) number: | K072212 | |
| Predicate<br>Device | Proprietary/Trade<br>Name: | Smith & Nephew Jet-X Bar System Clamps, Bars and<br>Posts - MR Conditional | |
| | Regulatory<br>Name/Reference | Smooth or threaded metallic bone fixation fastener,<br>21 CFR § 888.3040 | |
| | Regulatory Class | Class II | |
| | Product Code: | KTT | |
| | Panel: | Orthopedic | |
| | Manufacturer: | Smith & Nephew, Inc.,<br>1450 Brooks Rd., Memphis, TN 38116 | |
| Device<br>Description | The Medline ReNewal Reprocessed Smith & Nephew Jet-X External<br>Fixation systems. The devices consist of various clamps, posts, and bars,<br>which are used to in the management of bone fractures and reconstructive,<br>as well as corrective, orthopedic surgery. The materials used in their<br>manufacture are chosen to address a wide range of applications. These<br>devices have been designed to allow for the appropriate amount of rigidity<br>and stability. | | |
| Statement of<br>Intended<br>Use/Indications<br>for Use | Medline ReNewal Reprocessed Smith & Nephew Jet-X External Fixation<br>devices are intended to be used on adults or pediatric patients as required<br>and are intended to be used for fracture fixation (open and closed): post-<br>traumatic joint contracture which has resulted in loss of range of motion;<br>fractures and disease which generally may result in joint contractures or<br>loss of range of motion and fractures requiring distraction; pseudoarthrosis<br>or non-union of long bones; limb lengthening by epiphyseal or metaphyseal<br>distraction; correction of bony or soft tissue deformity; correction of<br>segmental bony or soft tissue defects; joint arthrodesis; and management<br>of comminuted intra-articular fractures of the distal radius. Medline | | |
Image /page/5/Picture/6 description: The image is completely black, lacking any discernible features or content. The darkness dominates the entire frame, creating a void-like impression. There are no shapes, lines, or textures visible, resulting in a uniform and featureless composition. The absence of light and detail makes it impossible to identify any objects or subjects within the image.
{6}------------------------------------------------
Image /page/6/Picture/1 description: The image shows two logos side by side. The logo on the left is for Medline, and it features the word "MEDLINE" in bold, white letters against a blue background, accompanied by a stylized white graphic. The logo on the right is for Renewal, with the "Re" in green and the "newal" in blue, and below it, the words "Full Circle Reprocessing" in blue.
| ReNewal Reprocessed Smith & Nephew Jet-X External Fixation devices<br>are for single use only. | | |
|------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------|
| Technological<br>Characteristics | The principle of operation of the reprocessed devices is identical to that of<br>the predicates. There are no changes in intended use, performance<br>specifications or method of operation. These devices utilize stainless steel,<br>titanium, carbon fiber and aluminum materials and technological<br>characteristics that are very similar when compared to the predicate<br>devices. | |
| Performance<br>Testing | The functional characteristics of the subject device have been evaluated<br>and have been determined to be substantially equivalent to the predicate<br>device based on the following tests:<br>• Functional performance studies: | |
| | ○ simulated use and artificial soiling; and<br>○ structural integrity;<br>○ carbon rod stiffness per the 4-point bend test<br>(pre-conditioning);<br>○ cyclical axial compression and tension bending test;<br>○ carbon rod stiffness per the 4-point bend test<br>(post-conditioning); and<br>○ disassembly and reassembly (pre-and post-sterilization).<br>• Cleaning:<br>○ visual inspection;<br>○ cleaning efficacy (residual protein and residual carbohydrate). | |
| Device Models | Catalog No. | Description |
| | 7106-2001 | JET-X Bar to pin clamp 10.5mm bar to 5mm pin |
| | 7106-2002 | JET-X Bar to bar clamp 10.5mm bar |
| | 7106-2004 | JET-X Bar to ring clamp |
| | 7106-2005 | JET-X Multiple pin clamp 10.5mm bar to 5mm pin |
| | 7107-0343 | JET-X Frame Stabilizer Tool |
| | 7106-4004 | JET-X Bar to ring clamp |
| | 7106-4005 | JET-X Bar Multiple Pin Clamp |
| | 7106-2009 | JET-X Freedom clamp 6mm bar to 5mm pin |
| | 7106-2010 | JET-X Mini bar 10.5mm to 4mm pin clamp |
| | 7106-2011 | JET-X Mini bar 6mm to 4mm pin clamp |
| | 7106-2012 | JET-X Mini Bar to Pin Clamp 6mm to 6mm |
| | 7106-2015 | JET-X Mini multiple pin clamp |
| | 7106-2016 | JET-X Mini Double pin clamp with ball joint |
| | 7106-2019 | JET-X Mini bar 6mm to 10.5mm bar clamp |
| | 7106-2721 | JET-X Ankle Clamp |
| | 7106-2722 | JET-X Freedom Bar to Ring Clamp 10.5mm Bar to Ring |
| | 7106-4001 | JET-X Freedom clamp 10.5mm bar to 5mm pin |
| | 7106-4002 | JET-X Freedom clamp 10.5mm bar to 10.5mm bar |
| | 7106-4009 | JET-X Bar to pin clamp |
| | 7106-4010 | JET-X Mini freedom clamp 10.5mm bar to 4mm pin |
| Catalog No. | Description | |
| 7106-4012 | JET-X Mini freedom clamp 6mm bar to 6mm pin | |
| 7106-4015 | JET-X Mini multiple pin clamp | |
| 7106-4016 | JET-X Mini double pin clamp with ball joint | |
| 7106-4019 | JET-X Freedom clamp 10.5mm bar to 6mm pin | |
| 7106-7372 | JET-X Quick clamp 10.5mm bar to 5mm pin | |
| 7106-7374 | JET-X Quick clamp 10.5mm bar to 10.5mm pin | |
| 7106-7375 | JET-X 4 Hole Pin Clamp | |
| 7106-7376 | JET-X 6 Hole Pin Clamp | |
| 7106-7371 | JET-X Mini Quick clamp 10.5mm to 4mm | |
| 7106-7373 | JET-X Mini Quick clamp 10.5mm bar to 6mm pin | |
| 7106-7377 | JET-X Quick Clamp 6mm to 4mm | |
| 7106-7378 | JET-X Quick Clamp 6mm to 6mm | |
| 7106-7380 | JET-X Quick Clamp 6mm to 5mm | |
| 7106-2160 | JET-X L-Bar 10.5mm | |
| 7106-2180 | JET-X V-Bar 10.5mm | |
| 7106-2100 | JET-X Bar 10.5mm x 100mm | |
| 7106-2150 | JET-X Bar 10.5mm x 150mm | |
| 7106-2200 | JET-X Bar 10.5mm x 200mm | |
| 7106-2250 | JET-X Bar 10.5mm x 250mm | |
| 7106-2300 | JET-X Bar 10.5mm x 300mm | |
| 7106-2350 | JET-X Bar 10.5mm x 350mm | |
| 7106-2400 | JET-X Bar 10.5mm x 400mm | |
| 7106-2500 | JET-X Bar 10.5mm x 500mm | |
| 7106-2600 | JET-X Bar 10.5mm x 600mm | |
| 7106-5050 | JET-X Mini Composite Bar 6mm x 50mm | |
| 7106-5075 | JET-X Composite Bar 6mm x 75mm | |
| 7106-5110 | JET-X Composite Bar 6mm x 110mm | |
| 7106-5150 | JET-X Composite Bar 6mm x 150mm | |
| 7106-5185 | JET-X Composite Bar 6mm x 185mm | |
| 7106-5225 | JET-X Composite Bar 6mm x 225mm | |
| 7106-5180 | JET-X Composite V-Bar 6mm | |
| 7106-5226 | JET-X Off-Set Bar 6mm | |
| 7106-7379 | JET-X Straight Post | |
| 7106-7381 | JET-X 30° Angled Post | |
| 7106-7382 | JET-X Freedom Post | |
{7}------------------------------------------------
Image /page/7/Picture/1 description: The image contains two logos side by side. The first logo is for Medline, and it features the word "MEDLINE" in white letters on a blue background, with a star-like symbol above the word. The second logo is for ReNewal Full Circle Reprocessing, with the word "ReNewal" in green and blue letters and the words "Full Circle Reprocessing" in smaller black letters below.
Device Model (concluded)
(concluded)
{8}------------------------------------------------
Image /page/8/Picture/1 description: The image shows two logos side by side. The logo on the left is for Medline, and it features a blue background with a white star-like symbol and the word "MEDLINE" in white letters. The logo on the right is for ReNewal, and it features the word "ReNewal" in green and blue letters, with the words "Full Circle Reprocessing" in smaller blue letters below.
Traditional 510(k) Notification Medline ReNewal Reprocessed Smith & Nephew External Fixation Devices
| Device<br>Characteristics | Predicate<br>Smith & Nephew<br>Jet-X Bar System<br>Clamps, Bars and Posts | Proposed<br>Medline ReNewal<br>Reprocessed<br>Smith & Nephew Jet-X<br>External Fixation Devices | Comparison<br>Same devices;<br>original and<br>reprocessed |
|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------|
| 510(k) Number | K072212 | TBD | N/A |
| Common Name | External Fixation System | External Fixation System | Same |
| Regulation No. | 888.3040 | 888.3040 | Same |
| Product Code | KTT | KTT | Same |
| Intended Use | The devices described<br>herein are intended to be<br>used on adults or pediatric<br>patients as required and<br…
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.