K172961 · Sit Sordina Iort Technologies Spa · IYE · Jun 11, 2018 · Radiology
Device Facts
Record ID
K172961
Device Name
LIAC HWL
Applicant
Sit Sordina Iort Technologies Spa
Product Code
IYE · Radiology
Decision Date
Jun 11, 2018
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 892.5050
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
LIAC HWL are mobile electron linear accelerators for intra-operative radiotherapy (IORT). Known as intraoperative radiation therapy (IORT), this technique allows delivery of high doses of radiation directly aimed at tumors or other sites. The LIAC HWL are meant to be used for radiotherapy in the operating theatre on a patient to which the surgeon has just removed a neoplasm. The devices must be sold by or on the order of a physician. They are by the general public or over-the-counter. LIAC HWL are electron accelerators that can work in an operating its specific characteristics in terms of cleaning possibility, noise and heat dissipation; in particular, they do not require to move the patient.
Device Story
Mobile electron linear accelerator (LINAC) for intra-operative radiotherapy (IORT); used in operating rooms immediately following surgical tumor resection. Device delivers high-dose electron radiation directly to tumor site while sparing surrounding healthy tissue. System comprises irradiating unit (stand), control unit, and applicators. Surgeon/physician operates device to target residual tumor beds. Modifications from predicate include additional shielding in radiant head to reduce scattered radiation, shorter applicators to reduce source-surface distance (SSD), higher dose rate, and modified remote control. Benefits include localized treatment without requiring patient transport to radiation oncology department.
Clinical Evidence
No clinical data provided. Substantial equivalence is based on bench testing, including radiation performance metrics (surface dose, field symmetry, dose rate, stray X-radiation, stability) and compliance with applicable safety standards.
Technological Characteristics
Mobile electron linear accelerator; energy levels 10 MeV and 12 MeV. Materials: PMMA applicators. Energy source: electrical (230V, 50Hz). Connectivity: remote control. Standards: IEC 60601-1, IEC 60601-2-1, IEC 62304. Features: hard docking, electron beam emission, integrated shielding in radiant head, 40 cm applicator length.
Indications for Use
Indicated for intra-operative radiotherapy (IORT) in the operating theatre for patients who have just undergone surgical removal of a neoplasm (malignant or benign conditions).
Regulatory Classification
Identification
A medical charged-particle radiation therapy system is a device that produces by acceleration high energy charged particles (e.g., electrons and protons) intended for use in radiation therapy. This generic type of device may include signal analysis and display equipment, patient and equipment supports, treatment planning computer programs, component parts, and accessories.
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image shows the logo of the U.S. Food and Drug Administration (FDA). The logo consists of two parts: the Department of Health and Human Services seal on the left and the FDA acronym along with the full name of the agency on the right. The FDA part of the logo is in blue, with the acronym in a square and the full name written out to the right of the square.
SIT SORDINA IORT TECHNOLOGIES SPA % Maurizio Pantaleoni CEO Isemed Srl Via P. Togliatti, 19/X Imola, Bo 40026 ITALY
Re: K172961
Trade/Device Name: LIAC HWL Regulation Number: 21 CFR 892.5050 Regulation Name: Medical charged-particle radiation therapy system Regulatory Class: II Product Code: IYE Dated: May 8, 2017 Received: May 10, 2017
Dear Maurizio Pantaleoni:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976. the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820);
June 11, 2018
{1}------------------------------------------------
# Page 2 - Maurizio Pantaleoni
and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/) and CDRH Learn (http://www.fda.gov/Training/CDRHLearn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (http://www.fda.gov/DICE) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).
Sincerely,
Michael D. O'Hara For
Robert Ochs, Ph.D. Director Division of Radiological Health Office of In Vitro Diagnostics and Radiological Health Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration
# Indications for Use
510(k) Number (if known)
K172961
Device Name LIAC HWL
Indications for Use (Describe)
LIAC HWL are mobile electron linear accelerators for intra-operative radiotherapy (IORT). Known as intraoperative radiation therapy (IORT), this technique allows delivery of high doses of radiation directly aimed at tumors or other sites.
The LIAC HWL are meant to be used for radiotherapy in the operating theatre on a patient to which the surgeon has just removed a neoplasm.
The devices must be sold by or on the order of a physician. They are by the general public or over-the-counter.
LIAC HWL are electron accelerators that can work in an operating its specific characteristics in terms of cleaning possibility, noise and heat dissipation; in particular, they do not require to move the patient.
Type of Use (Select one or both, as applicable)
X Prescription Use (Part 21 CFR 801 Subpart D)
| Over-The-Counter Use (21 CFR 801 Subpart C)
# CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
{3}------------------------------------------------
# S.I.T. -SORDINA IORT TECHNOLOGIES S.p.A TRADITIONAL 510(K) PREMARKET NOTIFICATION
# Traditional 510(k) Summary
This Traditional 510(k) Summary is being submitted as required by 21 CFR 807.92.
| 1. | General Information | |
|----|------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| | Submitter : | SIT SORDINA IORT TECHNOLOGIES SPA<br>Galleria del Pozzo Rosso, 13,<br>36100 Vicenza VI, Italy<br>Tel. +39 0444 233711<br>Registration Number: 3010625741<br>Owner/Operator Number: 10043521 |
| | Consultant/ Contact: | Maurizio Pantaleoni<br>ISEMED srl<br>Via P.Togliatti, 19/X<br>40026 Imola (BO) - ITALY<br>Mob. +39 348 4435155<br>Tel. +39 0542 683803<br>Fax +39 0542 698456<br>Email: regulatory@isemed.eu |
| | Summary Prepared Date: | November 24, 2017. |
# 2. Names
| Device Name: | LIAC HWL |
|------------------|------------------------------------------------------------------|
| Common Name: | Radiosurgery/radiotherapy treatment planning and delivery system |
| Regulation Name: | Medical charged particle radiationtherapy system |
| Product Code: | IYE |
| Classification: | 21CFR 892.5050; Class II |
# 3. Predicate Devices
The LIAC HWL is substantially equivalent to the following predicate devices, which are legally marketed in the US.
| Applicant | Device name | 510(k) Number |
|-------------------|-------------|---------------|
| SIT SORDINA IORT | LIAC | K110840 |
| TECHNOLOGIES SPA. | NOVAC11 | K112286 |
{4}------------------------------------------------
LIAC HWL (10 MeV &12 MeV)
# S.I.T. -SORDINA IORT TECHNOLOGIES S.p.A TRADITIONAL 510(K) PREMARKET NOTIFICATION
The primary predicate device is LIAC (K110840) and secondary predicate device is NOVAC11 (K112286). Both devices are manufactured by SIT SORDINA IORT TECHNOLOGIES SPA. And they have not been subject of any device recalls.
LIAC HWL is a modified model of its primary predicate device LIAC (K110840). Both have the same intended use and the same operation mode. LIAC HWL and its predicate devices are electron linear Accelerators used to perform radiation therapy during surgical procedures in an operating room. This technique is known as Intra-Operative Radiation Therapy (IORT) ant it is used for the treatment of malignant and benign conditions. IORT allows delivering of high doses of radiation directly to tumour site, while normal tissues are protected against dosage impact.
SIT SORDINA IORT TECHNOLOGIES SPA was written this Traditional 510(k) for the LIAC HWL in accordance to "Letter to Manufacturers of Linear Accelerators, Radiation Therapy Treatment Planning Systems, and Ancillary Devices" released in 2010 by CDRH.
LIAC HWL (10MeV & 12 MeV) and LIAC (10MeV & 12 MeV) (K110840) have the following technological differences:
- 5. LIAC HWL has additional shielding system in the radiant head to reduce scattered radiation.
- 6. LIAC HWL has lower length applicators to reduce SSD.
- 7. LIAC HWL has a higher dose rate.
- 8. LIAC HWL and predicate device LIAC (K110840) have a modified remote control.
SIT SORDINA IORT TECHNOLOGIES SPA has evaluated each modification of LIAC HWL to establish if the intended use or the technological features are different from those of predicate devices LIAC (K110840) and NOVAC 11 (K112286).
The differences between LIAC HWL and the predicate devices are summarized in the following comparison table:
{5}------------------------------------------------
SIT SORDINA IORT TECHNOLOGIES SP
TRADITIONAL 510(K)
PREMARKET NOTIFICATION
LIAC HWL
(10 MeV &12 MeV)
| Characteristic<br>Device Name | PROPOSE DEVICE | PREDICATE DEVICE | Remote control | YES | YES | YES | |
|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------|-------------------------------------------------------|--------------------------------------------------------------------------|---------------------------------------------------------------|
| | LIAC HWL<br>(MODELS: 10MEV AND 12MEV) | LIAC<br>(MODELS: 10MEV AND 12MEV) | NOVAC11 | Nominal energies | 4, 6, 8, 10 MeV (10 MeV)<br>6, 8, 10, 12 MeV (12 MeV) | 4, 6, 8, 10 MeV (10 MeV)<br>6, 8, 10, 12 MeV (12 MeV) | 4, 6, 8, 10 MeV |
| | Image: LIAC HWL | Image: LIAC | Image: NOVAC11 | Maximum operating<br>temperature | 25°C | 25°C | 25°C |
| Manufacture | SORDINA IORT TECHNOLOGIES SPA<br>S.I.T. - | SORDINA IORT TECHNOLOGIES SPA<br>K110840<br>S.I.T. - | SORDINA IORT TECHNOLOGIES SPA<br>K112286<br>S.I.T. - | Maximum power<br>dissipation | < 2.5 kW | < 2.5 kW | < 1 kW |
| GENERAL FEATURES | | | | Electrical power<br>requirement | 230 V, 50 Hz, 3 kVA | 230 V, 50 Hz, 3 kVA | 230 V, 50 Hz, 2.5 kVA |
| Classification | II | II | II | Applied Standards | IEC 60601-1 IEC 60601-2-1 IEC 62304 | IEC 60601-1 IEC 60601-1 Rev.2nd (IEC 60601-1-4 ) IEC 60601-1-2 IEC 62304 | IEC 60601-1 IEC 60601-1-2 IEC 60601-1-4 IEC 62304 EN60601-2-1 |
| Regulation number | 892.5050 | 892.5050 | 892.5050 | DEVICE DESIGN – RADIATION PERFORMANCE | | | |
| Product code | IYE | IYE | IYE | Surface dose | ≥ 88 % (10 MeV)<br>≥ 90 % (12 MeV) | ≥ 85 % (10 MeV)<br>≥ 87 %(12 MeV) | ≥ 80-85% |
| Product Code description | Accelerator, linear, medical<br>Medical charged-particle radiation<br>Therapy system | Accelerator, linear, medical<br>Medical charged-particle radiation<br>Therapy system | Accelerator, linear, medical<br>Medical charged-particle radiation<br>Therapy system | Field symmetry | ≤ 3 % | ≤ 3 % | ≤ 2 % |
| Indications for Use | | | | Pulse repetition<br>frequency | 5 - 50 Hz (depended on the selected<br>energy) | 5 - 50 Hz (depended on the selected<br>energy) | 9 Hz |
| | LIAC (MODELS: 10MEV AND 12MEV) IS A MOBILE<br>ELECTRON LINEAR ACCELERATOR FOR INTRA-<br>OPERATIVE RADIOTHERAPY (IORT).<br>KNOWN AS INTRAOPERATIVE RADIATION<br>THERAPY (IORT), THIS TECHNIQUE ALLOWS<br>DELIVERY OF HIGH DOSES OF RADIATION DIRECTLY<br>AIMED AT TUMORS OR OTHER SITES.<br>THE LIAC IS MEANT TO BE USED FOR<br>RADIOTHERAPY IN THE OPERATING THEATRE ON A<br>PATIENT TO WHICH THE SURGEON HAS JUST<br>REMOVED A NEOPLASM.<br>THE DEVICE MUST BE SOLD BY OR ON THE ORDER<br>OF A PHYSICIAN. IT IS NOT FOR USE BY THE<br>GENERAL PUBLIC OR OVER-THE-COUNTER. | NOVAC11 IS AN ELECTRON LINEAR<br>ACCELERATOR USED FOR RADIATION THERAPY<br>DURING SURGICAL PROCEDURES IN AN<br>OPERATING ROOM FOR THE TREATMENT OF<br>MALIGNANT AND BENIGN CONDITIONS.<br>KNOWN AS INTRAOPERATIVE RADIATION<br>THERAPY (IORT), THIS TECHNIQUE<br>ALLOWS DELIVERY OF HIGH DOSES OF<br>RADIATION DIRECTLY AIMED AT TUMORS OR<br>OTHER SITES WHILE AVOIDING DOSAGE TO<br>SURGICALLY MOBILIZED NORMAL TISSUES.<br>NOVAC11 IS A MOBILE AND<br>ARTICULATED MACHINE THAT CAN BE<br>MOVED TOWARDS THE PATIENT AN PUT IN<br>THE APPROPRIATE POSITION TO CARRY OUT<br>THE NECESSARY RADIOTHERAPY.<br>APPLICATORS LEAD THE ELECTRON BEAM TO<br>THE SURGICAL AREA OF INTEREST. | | Beam current | ≤ 1.5 mA | ≤ 1.5 mA | ≤ 1.5 mA |
| LIAC HWL ARE MOBILE ELECTRON LINEAR<br>ACCELERATORS FOR INTRA-OPERATIVE<br>RADIOTHERAPY (IORT). KNOWN AS<br>INTRAOPERATIVE RADIATION THERAPY<br>(IORT), THIS TECHNIQUE ALLOWS DELIVERY<br>OF HIGH DOSES OF RADIATION DIRECTLY<br>AIMED AT TUMORS OR OTHER SITES.<br>THE LIAC HWL ARE MEANT TO BE USED FOR<br>RADIOTHERAPY IN THE OPERATING THEATRE<br>ON A PATIENT TO WHICH THE SURGEON HAS<br>JUST REMOVED A NEOPLASM.<br>THE DEVICES MUST BE SOLD BY OR ON THE<br>ORDER OF A PHYSICIAN. THEY ARE NOT FOR<br>USE BY THE GENERAL PUBLIC OR OVER-THE-<br>COUNTER. | | | LIAC HWL ARE ELECTRON ACCELERATORS<br>THAT CAN WORK IN AN OPERATING<br>THEATER RESPECTING ITS SPECIFIC<br>CHARACTERISTICS IN TERMS OF CLEANING<br>POSSIBILITY, NOISE AND HEAT DISSIPATION; IN<br>PARTICULAR, THEY DO NOT REQUIRE TO<br>MOVE THE PATIENT. | Long term stability | ≤ 3% | ≤ 3% | ≤ 2 % |
| DEVICE DESIGN – TECHNICAL FEATURES | | | | Short term stability | ≤ 1% | ≤ 1% | ≤ 1 % |
| Design structure | STAND (irradiating unit) CONTROL UNIT APPLICATORS | STAND (irradiating unit) CONTROL UNIT APPLICATORS(ACCESSORY) | STAND (irradiating unit) CONTROL PANEL APPLICATORS PROTECTION DISC (ACCESSORY) | Dosimetric system<br>linearity | ≤ 1 % | ≤ 1 % | ≤ 1 % |
| Emission | ELECTRON BEAM | ELECTRON BEAM | ELECTRON BEAM | Dose rate (applicator<br>∅ 10 cm) | 10 - 30 Gy/min | 3 - 20 Gy/min | According to applicator<br>From 6 to 39 Gy/min |
| Type of structure | LINAC | LINAC | LINAC | Stray X-radiation<br>(PDD Bremsstrahlung<br>tail) | ≤ 0.4 % | ≤ 0.7 % | ≤ 0.2 % |
| Docking | HARD DOCKING | HARD DOCKING | HARD DOCKING | | | | |
{6}------------------------------------------------
SIT SORDINA IORT TECHNOLOGIES SP
TRADITIONAL 510(K)
PREMARKET NOTIFICATION
# LIAC HWL LIAC HWL
(10 MeV &12 MeV)
{7}------------------------------------------------
SIT SORDINA IORT TECHNOLOGIES SP
TRADITIONAL 510(K)
PREMARKET NOTIFICATION
LIAC HWL LIAC HWL
(10 MeV &12 MeV)
Vol001-27
{8}------------------------------------------------
SIT SORDINA IORT TECHNOLOGIES SP.
TRADITIONAL 510(K)
PREMARKET NOTIFICATION
LIAC HWL
(10 MeV &12 MeV)
| Source Surface<br>Distance (SSD) | 64.5 cm | 71.3 cm | 65-80 cm |
|------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------|----------------------------|
| Uniformity or Field<br>Flatness (value at the<br>maximum energy<br>level angle 0°) | ≤3% Ø 8,7,6 [cm]<br>≤7% Ø 10 [cm] (60601-2-1 conformity)<br>≤9% Ø 4,5 [cm]<br>≤12% Ø 3, 12 [cm]<br>≤4% Ø 9[cm] | ≤3% Ø 10, 8, 7, 6 [cm]<br>≤9% Ø 4,5 [cm]<br>≤12% Ø 3 [cm] | ≤5% |
| <b>COMPONENTS -Mobile Unit</b> | | | |
| Length | 210 cm | 210 cm | 230 cm |
| Width | 76 cm | 76 cm | 95 cm |
| Height | 180 cm | 180 cm | 199 cm |
| Weight | 570+ (< 230, shield) kg | 400+ (< 230, shield) kg | 630 kg |
| Focusing &<br>Collimation | Linac + applicators | Linac + applicators | Linac + applicators |
| <b>COMPONENTS -Control unit</b> | | | |
| Control unit<br>dimensions | 80 cm x 60 cm x 120 cm<br>(width, depth, height) | 80 cm x 57 cm x 114 cm<br>(width, depth, height) | |
| Control unit weight | 120 kg | 100 kg | |
| <b>COMPONENTS -Applicator</b> | | | |
| Applicator length | 40 cm | 60 cm | 100 cm |
| Applicator size | Ø: 3, 4, 5, 6, 7, 8, 9, 10 and 12 cm each<br>with bevel angels of 0°, 15°, 30°, 45° | Ø: 3, 4, 5, 6, 7, 8, 10 cm each with bevel<br>angels of 0°, 15°, 30°, 45° | Ø: 3, 4, 5, 6, 7, 8, 10 cm |
| Applicator Material | PMMA | PMMA | PMMA |
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.