← Product Code [LYZ](/productcode/LYZ) · K163168

# Vinyl Examination Gloves (White), Vinyl Examination Gloves (Blue), Vinyl Examination Gloves (Yellow) (K163168)

_Hebei Hongtai Plastic Products Company Limited · LYZ · Feb 23, 2017 · General Hospital · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K163168

## Device Facts

- **Applicant:** Hebei Hongtai Plastic Products Company Limited
- **Product Code:** [LYZ](/productcode/LYZ.md)
- **Decision Date:** Feb 23, 2017
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 880.6250
- **Device Class:** Class 1
- **Review Panel:** General Hospital

## Indications for Use

The Vinyl Examination Gloves (White, Blue, or Yellow) is a disposable device intended for medical purposes that is worn on the examiner's hands to prevent contamination between patient and examiner.

## Device Story

Disposable vinyl examination gloves; available in white, blue, or yellow; non-sterile; ambidextrous design. Used in medical settings by clinicians to provide a barrier against contamination between patient and examiner. Device functions as a physical barrier; material properties verified via tensile strength and elongation testing. Safety confirmed through biocompatibility testing for skin irritation and sensitization. Intended for single-use.

## Clinical Evidence

No clinical data. Bench testing only. Compliance verified via ASTM D6124-06 (residual powder), ASTM D5151-06 (freedom from holes), ASTM D5250-06 (physical properties), and ISO 10993-10:2010 (biocompatibility/irritation/sensitization).

## Technological Characteristics

Material: Vinyl (polyvinyl chloride). Non-sterile. Ambidextrous. Powder-free. Standards: ASTM D6124-06, ASTM D5151-06, ASTM D5250-06, ISO 10993-10:2010, ISO 2859-1:2009. Dimensions vary by size (XS-XL).

## Regulatory Identification

A non-powdered patient examination glove is a disposable device intended for medical purposes that is worn on the examiner's hand or finger to prevent contamination between patient and examiner. A non-powdered patient examination glove does not incorporate powder for purposes other than manufacturing. The final finished glove includes only residual powder from manufacturing.

## Predicate Devices

- Blue Vinyl Examination Gloves Powder Free ([K150224](/device/K150224.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

Image /page/0/Picture/1 description: The image shows the text "Public Health Service". The text is in a bold, sans-serif font. The text is black and the background is white. 

Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002

February 23, 2017

Hebei Hongtai Plastic Products Company Limited % Ray Wang Official Correspondent Beijing Believe Tech.service Co., Ltd. 5-1206, Build 332, Dafangju, No.25 Banbidian Rd., Liyuan Tongzhou District Beijing, 101121 CN

Re: K163168

Trade/Device Name: Vinyl Examination Gloves (White), Vinyl Examination Gloves (Blue), Vinyl Examination Gloves (Yellow) Regulation Number: 21 CFR 880.6250 Regulation Name: Patient Examination Glove Regulatory Class: Class I Product Code: LYZ Dated: January 14, 2017 Received: January 17, 2017

Dear Ray Wang:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug. and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device

{1}------------------------------------------------

related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address

http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to

http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.

You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address

http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.

Sincerely,

# Michael J. Ryan -S

for Tina Kiang, Ph.D.

Acting Director Division of Anesthesiology, General Hospital. Respiratory. Infection Control, and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{2}------------------------------------------------

#### DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration

### Indications for Use

510(k) Number (if known) K163168

#### Device Name

Vinyl Examination Gloves (White) Vinyl Examination Gloves (Blue) Vinyl Examination Gloves (Yellow)

#### Indications for Use (Describe)

The Vinyl Examination Gloves (White, Blue, or Yellow) is a disposable device intended for medical purposes that is worn on the examiner's hands to prevent contamination between patient and examiner.

Type of Use (Select one or both, as applicable)

| Prescription Use (Part 21 CFR 801 Subpart D)

X Over-The-Counter Use (21 CFR 801 Subpart C)

#### CONTINUE ON A SEPARATE PAGE IF NEEDED.

This section applies only to requirements of the Paperwork Reduction Act of 1995.

#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW! *

The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:

> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov

"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."

Form Approved: OMB No. 0910-0120 Expiration Date: January 31, 2017 See PRA Statement below.

{3}------------------------------------------------

## 510(k) Summary

The assigned 510(k) Number: K163168

- 1. Date of Preparation:2017/02/23
- 2. Sponsor Identification

#### Hebei Hongtai Plastic Products Company Limited.

No. 15, Luban Road, Julu County, Xingtai, Hebei Province 055250, China Establishment Registration Number: Not yet registered

Contact Person: Liu Wei Position: General Manager Tel: +86-319-4362370 Fax: +86-319-4362371 Email: nedvidel@handform.cn

- 3. Designated Submission Correspondent
Mr. Ray Wang

#### Beijing Believe Tech. Service Co., Ltd

Tel: +86-18910677558, Fax: +86-21-68093116 Email: Ray.Wang@believe-med.com

{4}------------------------------------------------

- 4. Identification of Proposed Device
Trade Name: Vinyl Examination Gloves (White), Vinyl Examination Gloves (Blue), Vinyl Examination Gloves (Yellow): Common Name: Vinyl Patient Examination Gloves (Powder Free) Model(s): XS S M L XL

Regulatory Information Classification Name: Patient Examination Glove Classification:I Product Code: LYZ Regulation Number: 21 CFR 880.6250 Review Panel: General Hospital

Indication for use Statement:

The Vinyl Examination Gloves (White, Blue, or Yellow) is a disposable device intended for medical purposes that is worn on the examiner's hands to prevent contamination between patient and examiner.

- 5. Device Description
The proposed device is Powder Free Vinyl Patient Examination Gloves. The proposed device is available in three different colors: White, Blue, and Yellow. The proposed device was tested according to the following standards: ASTM D 6124-06, ASTM D 5151-06, ASTM D5250-06, ISO 10993-10:2010 and ISO 2859-1:2009.The proposed device is non-sterile.

- 6. Identification of Predicate Device(s)
Predicate Device K150224 Blue Vinyl Examination Gloves Powder Free ZIBO SANYING TRADE CO., LTD

- 7. Non-Clinical Test Conclusion
Non clinical tests were conducted to verify that the proposed device met all specifications and the proposed device is Substantially Equivalent (SE) to the predicate device. The test results demonstrated that the proposed device complies with the following standards:

- > ISO 10993-10: 2010 Biological Evaluation Of Medical Devices - Part 10: Tests For Irritation And Skin Sensitization.
- > ASTM D6124-06 (Reaffirmation 2011), Standard Test Method for Residual Powder on Medical Gloves
- A ASTM D 5151-06 (Reapproved 2011), Standard Test Method for Detection of Holes in Medical Gloves.

{5}------------------------------------------------

- > ASTM D5250-06, Standard Specification for Poly(vinyl chloride) Gloves for Medical Application.
- ISO 2859-1:1999, "Sampling Procedures for Inspection by Attributes Part I: Sampling > Plans Indexed by Acceptable Quality Level (AQL) for Lot-by-Lot Inspection.
- Clinical Test Conclusion 8.

No clinical study is included in this submission.

{6}------------------------------------------------

| ITEM                        | Proposed Device<br>(K163168)                                                                                                                                                                           | Predicate Device (K150224)<br>Blue Vinyl Examination Gloves Powder<br>Free                                                                                                                               | Remark |
|-----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------|
| Product Code                | LYZ                                                                                                                                                                                                    | LYZ                                                                                                                                                                                                      | Same   |
| Regulation No.              | 21 CFR 880.6250                                                                                                                                                                                        | 21 CFR 880.6250                                                                                                                                                                                          | Same   |
| Class                       | I                                                                                                                                                                                                      | I                                                                                                                                                                                                        | Same   |
| Intended Use                | The Vinyl Examination Gloves (White, Blue, or Yellow) is a disposable device intended for medical purposes that is worn on the examiner's hands to prevent contamination between patient and examiner. | The Blue Vinyl Examination Gloves Powder Free is a disposable device intended for medical purposes that is worn on the examiner's hands or finger to prevent contamination between patient and examiner. | Same   |
| Powdered or<br>Powered free | Powdered free                                                                                                                                                                                          | Powdered free                                                                                                                                                                                            | Same   |
| Design Feature              | ambidextrous                                                                                                                                                                                           | ambidextrous                                                                                                                                                                                             | Same   |
| Labeling<br>Information     | Single-use indication, powder free, device color, device name, glove size and quantity, Vinyl Examination Gloves, Non-Sterile                                                                          | Single-use indication, powder free, device color, device name, glove size and quantity, Vinyl Examination Gloves, Non-Sterile                                                                            | Same   |

#### 9. Substantially Equivalent (SE) Comparison

Table 1 General Comparison

{7}------------------------------------------------

|                                                                            | Designation    | Size |     |     |     | Tolerance |         |
|----------------------------------------------------------------------------|----------------|------|-----|-----|-----|-----------|---------|
|                                                                            |                | XS   | S   | M   | L   | XL        |         |
| Proposed Device<br>(K163168)                                               | Length, mm     | 230  | 230 | 235 | 245 | 245       | min     |
|                                                                            | Width, mm      | 80   | 85  | 95  | 105 | 115       | $\pm 5$ |
|                                                                            | Thickness, mm: |      |     |     |     |           |         |
|                                                                            | Finger         | 0.05 |     |     |     |           | min     |
|                                                                            | Palm           | 0.08 |     |     |     |           | min     |
| Predicate Device (K150224)<br>Blue Vinyl Examination Gloves<br>Powder Free | Designation    | Size |     |     |     | Tolerance |         |
|                                                                            |                |      | S   | M   | L   | XL        |         |
|                                                                            | Length, mm     |      | 240 | 240 | 240 | 240       | min     |
|                                                                            | Width, mm      |      | 85  | 95  | 105 | 115       | $\pm 5$ |
|                                                                            | Thickness, mm: |      |     |     |     |           |         |
|                                                                            | Finger         | 0.10 |     |     |     |           | min     |
|                                                                            | Palm           | 0.08 |     |     |     |           | min     |
| Remark                                                                     | Analysis 1     |      |     |     |     |           |         |

Table 2 Device Dimensions Comparison

Analysis 1:

The proposed device has different size specifications as compared to the predicate device, but the proposed device meets the specifications of ASTM D5250.

{8}------------------------------------------------

| ITEM                   |                 | Proposed Device<br>(K163168)                                                        | Predicate Device (K150224)<br>Blue Vinyl Examination Gloves<br>Powder Free                               | Remark      |            |
|------------------------|-----------------|-------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------|-------------|------------|
| Colorant               |                 | White, Blue, Yellow                                                                 | Blue                                                                                                     | Analysis 2  |            |
| Physical<br>Properties | Before<br>Aging | Tensile<br>Strength                                                                 | 15 MPa, min                                                                                              | 13 MPa, min |            |
|                        |                 | Ultimate<br>Elongation                                                              | 380 % min                                                                                                | 400 % min   |            |
|                        | After<br>Aging  | Tensile<br>Strength                                                                 | 15 MPa, min                                                                                              | 13 MPa, min | Analysis 3 |
|                        |                 | Ultimate<br>Elongation                                                              | 380 % min                                                                                                | 400 % min   |            |
| Comply with ASTM D5250 |                 |                                                                                     | Comply with ASTM D5250<br>11 MPa min./300% min.                                                          | Same        |            |
| Freedom from Holes     |                 | Be free from holes when tested in<br>accordance with ASTM D5151<br>AQL 1.5          | Be free from holes when tested<br>in accordance with ASTM<br>D5151 under AQL 2.5/Inspection<br>Level G-I | Same        |            |
| Powder Content         |                 | 0.50 mg per glove (White)<br>0.60 mg per glove (Blue)<br>0.70 mg per glove (Yellow) | Meet the requirements of ASTM<br>D5250<br>Less than 2mg per glove                                        | Same        |            |

Table 3 Performance Comparison

Table 4 Safety Comparison

| ITEM               | Proposed Device<br>(K163168) | Predicate Device (K150224)<br>Blue Vinyl Examination Gloves<br>Powder Free | Remark                     |      |
|--------------------|------------------------------|----------------------------------------------------------------------------|----------------------------|------|
| Material           | Vinyl                        | Vinyl                                                                      | Same                       |      |
| Biocompatibility   | Irritation                   | Under the conditions of the study,<br>not an irritant                      | Comply with ISO 10993-10   | Same |
|                    | Sensitization                | Under conditions of the study, not a<br>sensitizer.                        |                            | Same |
| Label and Labeling |                              | Meet FDA's Recommendations                                                 | Meet FDA's Recommendations | Same |

#### Analysis 2:

The proposed device has different colors as compared to the predicate device. This difference may cause potential biocompatibility risks. To address this concern, we evaluated the biocompatibility testing according to the standard ISO 10993-10. The results showed that the proposed devices (White, Blue, Yellow) did not induce skin irritation and skin sensitization.

{9}------------------------------------------------

The proposed device has different Ultimate Elongation after aging as compared to the predicate device, but the proposed device meets the specifications of ASTM D5250.

- 10. Substantially Equivalent (SE) Conclusion
The conclusions drawn from the nonclinical tests demonstrate that the proposed device is as safe, as effective, and performs as well as or better than the legally marketed predicate device.

---

**Source:** [https://fda-staging.innolitics.com/device/K163168](https://fda-staging.innolitics.com/device/K163168)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).