HDL-Cholesterol Gen.4

K162593 · Roche Diagnostics Operations (Rdo) · LBS · Oct 19, 2016 · Clinical Chemistry

Device Facts

Record IDK162593
Device NameHDL-Cholesterol Gen.4
ApplicantRoche Diagnostics Operations (Rdo)
Product CodeLBS · Clinical Chemistry
Decision DateOct 19, 2016
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 862.1475
Device ClassClass 1
AttributesReal-World Evidence

Real-World Evidence

SubmissionDeviceSponsorRWD SourcesRWE Use SummaryKey Tags
K162593 · Oct 19, 2016HDL-Cholesterol Gen.4Roche Diagnostics Operations (Rdo)Routine laboratory serum samplesRoutine laboratory serum samples were used to perform a method comparison between the candidate device and the predicate device to demonstrate substantial equivalence.Method comparison; Routine laboratory samples

Clinical Evidence

Study DesignPopulationComparatorKey Endpoints
Method comparison studyRoutine laboratory serum samples; Sample Size: 111Ultra N-geneous HDL Cholesterol reagent (predicate)Passing Bablok regression analysis (y = 0.956x - 0.949, r = 0.995)

Indications for Use

In vitro diagnostic test for the quantitative determination of the HDL-cholesterol concentration in human serum and plasma on Roche/Hitachi cobas c systems. A lipoprotein test system is a device intended to measure lipoprotein in serum and plasma. Lipoprotein measurements are used in the diagnosis and treatment of lipid disorders (such as diabetes mellitus), atherosclerosis, and various liver and renal diseases.

Device Story

Homogeneous enzymatic colorimetric assay; utilizes polyanions and detergent to form water-soluble complexes with non-HDL lipoproteins (LDL, VLDL, chylomicrons), blocking their reaction with cholesterol esterase (CHER) and cholesterol oxidase (CHOD). HDL-cholesterol reacts with CHER and CHOD to produce hydrogen peroxide; peroxidase reacts with 4-amino-antipyrine and EMSE to form a dye. Color intensity, measured photometrically, is directly proportional to HDL-cholesterol concentration. Used in clinical laboratories on Roche/Hitachi cobas c systems; operated by laboratory technicians. Output provides quantitative HDL-cholesterol concentration (mg/dL) to assist clinicians in diagnosing and managing lipid disorders, atherosclerosis, and metabolic diseases.

Clinical Evidence

Bench testing only. Performance validated via precision (CLSI EP5-A3), LoB/LoD/LoQ (CLSI EP17-A2), linearity (CLSI EP6-A), and interference studies (hemolysis, lipemia, icterus, triglycerides, and drugs). Method comparison against predicate (n=111) showed Passing Bablok regression y = 0.956x - 0.949 (r=0.995). Matrix comparison confirmed performance across serum, plasma (Li-heparin, K2/K3-EDTA), and gel separation tubes.

Technological Characteristics

Homogeneous enzymatic colorimetric assay. Reagents include TAPSO/Bis-Tris buffers, cholesterol esterase, cholesterol oxidase, peroxidase, 4-amino-antipyrine, EMSE, polyanions, and detergents. Photometric detection principle. Designed for use on Roche/Hitachi cobas c systems. Measuring range 3.09-150 mg/dL. Refrigerated storage (2-8°C).

Indications for Use

Indicated for quantitative determination of HDL-cholesterol in human serum and plasma for patients requiring assessment of lipid disorders, including diabetes mellitus, atherosclerosis, and liver or renal diseases.

Regulatory Classification

Identification

A lipoprotein test system is a device intended to measure lipoprotein in serum and plasma. Lipoprotein measurements are used in the diagnosis and treatment of lipid disorders (such as diabetes mellitus), atherosclerosis, and various liver and renal diseases.

Submission Summary (Full Text)

{0} # 510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION ## TRIAGE-QUICK REVIEW DECISION SUMMARY 510(k) #: K162593 This 510(k) was reviewed under OIR’s Triage-Quick Review Program. This program represents an internal workload management tool intended to reduce internal FDA review resources for 510(k) applications that are of good quality upon receipt by FDA. The information in the 510(k) is complete and supports a substantial equivalence (SE) determination. Please refer to the applicant’s 510(k) summary for a summary of the information that supports this SE determination.
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...