Dentalis Bio Solution Implants
Device Facts
| Record ID | K161281 |
|---|---|
| Device Name | Dentalis Bio Solution Implants |
| Applicant | Dentalis Bio Solution Implants, LLC |
| Product Code | DZE · Dental |
| Decision Date | Jan 11, 2017 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 872.3640 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
Dentalis Bio Solutions Implant System is used to replace missing masticatory functional units (teeth) in single or multiple unit applications within the mandible or maxilla. The device may be used equally well in a single-stage or two-stage surgical procedure. It is indicated for immediate implantation in extraction sites or implantation in partially healed or completely healed alveolar ridge situations. When a one-stage surgical approach is applied, the implant may be immediately loaded when good primary stability is achieved and the functional load is appropriate. The Dentalis Bio Solution implant with Narrow diameter Ø3.0 shall be used only to replace maxillary lateral incisors and mandibular lateral and central incisors situations. Dentalis Bio Solution One Piece implants are specifically indicated for replacing maxillary lateral incisors and mandibular central and lateral incisors. They are used for immediate, non-occlusal provisionalization in single-tooth restorations
Device Story
Dentalis Bio Solutions Implant System consists of endosseous dental implants used to replace missing teeth. Implants are surgically placed into the mandible or maxilla by dental professionals. Procedure may be single-stage or two-stage; immediate loading is permitted if primary stability is achieved. Narrow diameter and one-piece variants have specific anatomical site restrictions. Device functions as a mechanical anchor for prosthetic restorations, restoring masticatory function. Benefits include tooth replacement and potential for immediate provisionalization.
Clinical Evidence
no clinical data
Technological Characteristics
Endosseous dental implants; metallic construction; various diameters and lengths; single-stage or two-stage surgical application; non-software device.
Indications for Use
Indicated for patients requiring replacement of missing teeth in mandible or maxilla. Includes single or multiple unit applications, immediate implantation in extraction sites, or implantation in partially/completely healed alveolar ridges. Narrow diameter (Ø3.0) implants restricted to maxillary lateral incisors and mandibular lateral/central incisors. One-piece implants restricted to maxillary lateral incisors and mandibular central/lateral incisors for immediate, non-occlusal provisionalization.
Regulatory Classification
Identification
An endosseous dental implant is a prescription device made of a material such as titanium or titanium alloy that is intended to be surgically placed in the bone of the upper or lower jaw arches to provide support for prosthetic devices, such as artificial teeth, in order to restore a patient's chewing function.
Special Controls
*Classification.* (1) Class II (special controls). The device is classified as class II if it is a root-form endosseous dental implant. The root-form endosseous dental implant is characterized by four geometrically distinct types: Basket, screw, solid cylinder, and hollow cylinder. The guidance document entitled “Class II Special Controls Guidance Document: Root-Form Endosseous Dental Implants and Endosseous Dental Implant Abutments” will serve as the special control. (See § 872.1(e) for the availability of this guidance document.)(2) *Classification.* Class II (special controls). The device is classified as class II if it is a blade-form endosseous dental implant. The special controls for this device are:(i) The design characteristics of the device must ensure that the geometry and material composition are consistent with the intended use; (ii) Mechanical performance (fatigue) testing under simulated physiological conditions to demonstrate maximum load (endurance limit) when the device is subjected to compressive and shear loads; (iii) Corrosion testing under simulated physiological conditions to demonstrate corrosion potential of each metal or alloy, couple potential for an assembled dissimilar metal implant system, and corrosion rate for an assembled dissimilar metal implant system; (iv) The device must be demonstrated to be biocompatible; (v) Sterility testing must demonstrate the sterility of the device; (vi) Performance testing to evaluate the compatibility of the device in a magnetic resonance (MR) environment; (vii) Labeling must include a clear description of the technological features, how the device should be used in patients, detailed surgical protocol and restoration procedures, relevant precautions and warnings based on the clinical use of the device, and qualifications and training requirements for device users including technicians and clinicians; (viii) Patient labeling must contain a description of how the device works, how the device is placed, how the patient needs to care for the implant, possible adverse events and how to report any complications; and (ix) Documented clinical experience must demonstrate safe and effective use and capture any adverse events observed during clinical use.