Apogee 5500/Apogee 5300/ Apogee 5800 Digital Color Doppler Ultrasound Imaging System
K160853 · Shantou Institute of Ultrasonic Instruments Co., Ltd. (Siui) · IYN · Jun 27, 2016 · Radiology
Device Facts
Record ID
K160853
Device Name
Apogee 5500/Apogee 5300/ Apogee 5800 Digital Color Doppler Ultrasound Imaging System
Applicant
Shantou Institute of Ultrasonic Instruments Co., Ltd. (Siui)
Product Code
IYN · Radiology
Decision Date
Jun 27, 2016
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 892.1550
Device Class
Class 2
Attributes
Pediatric
Indications for Use
The Apogee 5500/ Apogee 5300 /Apogee 5800 Digital Color Doppler Ultrasound Imaging System is intended for use by a qualified physician for ultrasound evaluation of Fetal, Abdominal, Pediatric, Small Organ (Thyroid, Testes, Breast), Neonatal Cephalic, Musculoskeletal (Conventional and Superficial), Cardiac (Adult and Pediatric), Peripheral Vascular, Trans-vaginal, Trans-rectal, Obstetrics/ Gynecology and Urology applications.
Device Story
Digital ultrasound imaging system; supports linear, convex, phased array, 3D, and endocavity transducers. Inputs: ultrasonic echoes from patient tissue. Processing: front-end transmit/receive circuitry; post-processing of echoes; generation of B-mode, M-mode, Color Doppler, PWD, CWD, 3D/4D, Elastography, XBeam, Panoscope, Anatomical M-mode, TDI, and MFI. Output: real-time anatomical and blood flow images on 19-inch monitor; measurements/calculations; cine review; image storage. Used in clinical settings by qualified physicians. Assists in clinical diagnosis through visualization of anatomical structures and fluid flow; supports communication of cardiovascular status via measurement packages.
Clinical Evidence
Bench testing only. Acoustic output measured per NEMA UD 2:2004. Conformance to electrical and biocompatibility standards (IEC 60601-1, ISO 10993-5, ISO 10993-10) verified. No clinical data presented.
Technological Characteristics
Digital ultrasound system; linear, convex, phased array, 3D, and endocavity transducers. Modes: B, M, PWD, CWD, Color Doppler, 3D/4D, Elastography, XBeam, Panoscope, Anatomical M-mode, TDI, MFI, ECG. 19-inch monitor, 10.4-inch touch screen. Connectivity: I/O panel for printing/recording. Standards: IEC 60601-1, ISO 10993, NEMA UD 2.
Indications for Use
Indicated for ultrasound evaluation of fetal, abdominal, pediatric, small organ (thyroid, testes, breast), neonatal cephalic, musculoskeletal (conventional and superficial), cardiac (adult and pediatric), peripheral vascular, trans-vaginal, trans-rectal, obstetric, gynecologic, and urologic applications in patients requiring diagnostic ultrasound imaging.
Regulatory Classification
Identification
An ultrasonic pulsed doppler imaging system is a device that combines the features of continuous wave doppler-effect technology with pulsed-echo effect technology and is intended to determine stationary body tissue characteristics, such as depth or location of tissue interfaces or dynamic tissue characteristics such as velocity of blood or tissue motion. This generic type of device may include signal analysis and display equipment, patient and equipment supports, component parts, and accessories.
Predicate Devices
Apogee 3800 Digital Color Doppler Ultrasound Imaging System (K110841)
Acuson X700 Diagnostic Ultrasound System (K141846)
Submission Summary (Full Text)
{0}------------------------------------------------
Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo features a stylized caduceus symbol, which is often associated with medicine and healthcare. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular pattern around the symbol. The logo is simple and professional, reflecting the department's role in public health and welfare.
Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002
June 27, 2016
Shantou Institute of Ultrasonic Instruments Co., Ltd (SIUI) % Ms. Flower Cai Liaison Manager 77 Jinsha Road Shantou, Guangdong 515041 CHINA
Re: K160853
Trade/Device Name: Apogee 5500 Digital Color Doppler Ultrasound Imaging System Apogee 5300 Digital Color Doppler Ultrasound Imaging System Apogee 5800 Digital Color Doppler Ultrasound Imaging System Regulation Number: 21 CFR 892.1550 Regulation Name: Ultrasonic pulsed doppler imaging system Regulatory Class: II Product Code: IYN, IYO, ITX Dated: March 29, 2016 Received: April 4, 2016
Dear Ms. Cai:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set
{1}------------------------------------------------
forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638 2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.
Sincerely yours,
**Robert Ocks**
Robert Ochs, Ph.D. Director Division of Radiological Health Office of In Vitro Diagnostics and Radiological Health Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
# Indications for Use
510(k) Number (if known) K160853
#### Device Name
Apogee 5500 Digital Color Doppler Ultrasound Imaging System Apogee 5300 Digital Color Doppler Ultrasound Imaging System Apogee 5800 Digital Color Doppler Ultrasound Imaging System
#### Indications for Use (Describe)
The device is intended for use by a qualified physician for ultrasound evaluation of Fetal, Abdominal, Pediatric, Small Organ (Thyroid, Testes, Breast), Neonatal Cephalic, Musculoskeletal (Conventional and Superficial), Cardiac (Adult and Pediatric), Peripheral Vascular, Trans-rectal, Obstetrics/ Gynecology and Urology applications.
| Type of Use (Select one or both, as applicable) | |
|-------------------------------------------------|---------------------------------------------|
| × Prescription Use (Part 21 CFR 801 Subpart D) | Over-The-Counter Use (21 CFR 801 Subnart C) |
#### CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
{3}------------------------------------------------
## 3.1 System Indications for Use Form
# System: Apogee 5500/ Apogee 5300/ Apogee 5800
| Clinical Application | | Mode of Operation | | | | | | |
|-----------------------------|------------------------------------|-------------------|---|-----|-----|------------------|-----------------------|---------------------|
| General<br>(Track 1 Only) | Specific<br>(Tracks 1 & 3) | B | M | PWD | CWD | Color<br>Doppler | Combined<br>(Specify) | Other*<br>(Specify) |
| Ophthalmic | Ophthalmic | | | | | | | |
| | Fetal | N | N | N | | N | | N |
| | Abdominal | N | N | N | | N | | N |
| | Intra-operative (Specify) | | | | | | | |
| | Intra-operative (Neuro) | | | | | | | |
| | Laparoscopic | | | | | | | |
| Fetal<br>Imaging<br>& Other | Pediatric | N | N | N | | N | | N |
| | Small Organ (Specify) | N | N | N | | N | | N |
| | Neonatal Cephalic | N | N | N | N | N | | N |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | N | N | N | | N | | N |
| | Trans-vaginal | N | N | N | | N | | N |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skeletal<br>(Conventional) | N | N | N | | N | | N |
| | Musculo-skeletal<br>(Superficial) | N | N | N | | N | | N |
| | Intravascular | | | | | | | |
| | Other (Specify) | N | N | N | | N | | N |
| | Cardiac Adult | N | N | N | N | N | | N |
| Cardiac | Cardiac Pediatric | N | N | N | N | N | | N |
| | Intravascular (Cardiac) | | | | | | | |
| | Trans-esoph. (Cardiac) | | | | | | | |
| | Intra-cardiac | | | | | | | |
| | Other (Specify) | | | | | | | |
| Peripheral<br>Vessel | Peripheral vessel | N | N | N | | N | | N |
| | Other (Specify) | | | | | | | |
N = new indication; P = previously cleared by FDA; E = added under this appendix
* Other modes of operation include: CPA, 3-D Imaging, 4-D Imaging, Elastography, XBeam, Panoscope, Trapezoidal /Extended Sector Imaging, Anatomical M-mode, ECG
Additional Comments: Other uses include: Gynecology, Prostate, Urology, Kidney, Uterus, Ovary Small organs include: Thyroid, Testes, Breast
{4}------------------------------------------------
#### 3.2 Transducer Indications for Use Form
#### Transducer: Convex Array C3LC
| Clinical Application | | Mode of Operation | | | | | | |
|---------------------------|------------------------------------|-------------------|---|-----|-----|------------------|-----------------------|---------------------|
| General<br>(Track 1 Only) | Specific<br>(Tracks 1 & 3) | B | M | PWD | CWD | Color<br>Doppler | Combined<br>(Specify) | Other*<br>(Specify) |
| Ophthalmic | Ophthalmic | | | | | | | |
| | Fetal | N | N | N | | N | | N |
| | Abdominal | N | N | N | | N | | N |
| | Intra-operative (Specify) | | | | | | | |
| | Intra-operative (Neuro) | | | | | | | |
| | Laparoscopic | | | | | | | |
| Fetal | Pediatric | | | | | | | |
| Imaging | Small Organ (Specify) | | | | | | | |
| & Other | Neonatal Cephalic | | | | | | | |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | | | | | | | |
| | Trans-vaginal | | | | | | | |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skeletal<br>(Conventional) | | | | | | | |
| | Musculo-skeletal<br>(Superficial) | | | | | | | |
| | Intravascular | | | | | | | |
| | Other (Specify) | N | N | N | | N | | N |
| | Cardiac Adult | | | | | | | |
| Cardiac | Cardiac Pediatric | | | | | | | |
| | Intravascular (Cardiac) | | | | | | | |
| | Trans-esoph. (Cardiac) | | | | | | | |
| | Intra-cardiac | | | | | | | |
| | Other (Specify) | | | | | | | |
| Peripheral | Peripheral vessel | | | | | | | |
| Vessel | Other (Specify) | | | | | | | |
N = new indication; P = previously cleared by FDA; E = added under this appendix
* Other modes of operation include: CPA, 3-D Imaging, Elastography, XBeam, Panoscope, Trapezoidal / Extended Sector Imaging, Anatomical M-mode, ECG
Additional Comments: Other uses include: Gynecology, Urology, Prostate, Kidney, Uterus, Ovary
{5}------------------------------------------------
#### 3.3 Transducer Indications for Use Form
# Transducer: Linear Array L8LC
| Clinical Application | | Mode of Operation | | | | | | |
|---------------------------|----------------------------|-------------------|---|-----|-----|------------------|-----------------------|---------------------|
| General<br>(Track 1 Only) | Specific<br>(Tracks 1 & 3) | B | M | PWD | CWD | Color<br>Doppler | Combined<br>(Specify) | Other*<br>(Specify) |
| Ophthalmic | Ophthalmic | | | | | | | |
| | Fetal | | | | | | | |
| | Abdominal | | | | | | | |
| | Intra-operative (Specify) | | | | | | | |
| | Intra-operative (Neuro) | | | | | | | |
| | Laparoscopic | | | | | | | |
| Fetal | Pediatric | N | N | N | | N | | N |
| Imaging | Small Organ (Specify) | N | N | N | | N | | N |
| & Other | Neonatal Cephalic | | | | | | | |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | | | | | | | |
| | Trans-vaginal | | | | | | | |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skeletal | N | N | N | | N | | N |
| | (Conventional) | | | | | | | |
| | Musculo-skeletal | N | N | N | | N | | N |
| | (Superficial) | | | | | | | |
| | Intravascular | | | | | | | |
| | Other (Specify) | N | N | N | | N | | N |
| | Cardiac Adult | | | | | | | |
| Cardiac | Cardiac Pediatric | | | | | | | |
| | Intravascular (Cardiac) | | | | | | | |
| | Trans-esoph. (Cardiac) | | | | | | | |
| | Intra-cardiac | | | | | | | |
| | Other (Specify) | | | | | | | |
| Peripheral | Peripheral vessel | N | N | N | | N | | N |
| Vessel | Other (Specify) | | | | | | | |
N = new indication; P = previously cleared by FDA; E = added under this appendix * Other modes of operation include: CPA, 3-D Imaging, Elastography, XBeam, Panoscope, Trapezoidal / Extended Sector Imaging, Anatomical M-mode, ECG Additional Comments: Small organs include: Thyroid, Testes, Breast
{6}------------------------------------------------
#### 3.4 Transducer Indications for Use Form
# Transducer: Convex Array C5LF
| Clinical Application | | Mode of Operation | | | | | | |
|-----------------------------|------------------------------------|-------------------|---|-----|-----|------------------|-----------------------|---------------------|
| General<br>(Track 1 Only) | Specific<br>(Tracks 1 & 3) | B | M | PWD | CWD | Color<br>Doppler | Combined<br>(Specify) | Other*<br>(Specify) |
| Ophthalmic | Ophthalmic | | | | | | | |
| | Fetal | N | N | N | | N | | N |
| | Abdominal | N | N | N | | N | | N |
| | Intra-operative (Specify) | | | | | | | |
| | Intra-operative (Neuro) | | | | | | | |
| | Laparoscopic | | | | | | | |
| Fetal<br>Imaging<br>& Other | Pediatric | | | | | | | |
| | Small Organ (Specify) | | | | | | | |
| | Neonatal Cephalic | | | | | | | |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | | | | | | | |
| | Trans-vaginal | | | | | | | |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skeletal<br>(Conventional) | | | | | | | |
| | Musculo-skeletal<br>(Superficial) | | | | | | | |
| | Intravascular | | | | | | | |
| | Other (Specify) | N | N | N | | N | | N |
| Cardiac | Cardiac Adult | | | | | | | |
| | Cardiac Pediatric | | | | | | | |
| | Intravascular (Cardiac) | | | | | | | |
| | Trans-esoph. (Cardiac) | | | | | | | |
| | Intra-cardiac | | | | | | | |
| | Other (Specify) | | | | | | | |
| Peripheral<br>Vessel | Peripheral vessel | | | | | | | |
| | Other (Specify) | | | | | | | |
N = new indication; P = previously cleared by FDA; E = added under this appendix
* Other modes include: CPA, 3-D Imaging, 4-D Imaging, Elastography, XBeam, Panoscope, Trapezoidal /Extended Sector Imaging, Anatomical M-mode, ECG
Additional Comments: Other uses include: Gynecology, Urology, Prostate, Kidney, Uterus, Ovary
{7}------------------------------------------------
## 3.5 Transducer Indications for Use Form
# Transducer: Phased Array P3FC
| Clinical Application | | Mode of Operation | | | | | | |
|-----------------------------|------------------------------------|-------------------|---|-----|-----|------------------|-----------------------|---------------------|
| General<br>(Track 1 Only) | Specific<br>(Tracks 1 & 3) | B | M | PWD | CWD | Color<br>Doppler | Combined<br>(Specify) | Other*<br>(Specify) |
| Ophthalmic | Ophthalmic | | | | | | | |
| | Fetal | | | | | | | |
| | Abdominal | | | | | | | |
| | Intra-operative (Specify) | | | | | | | |
| | Intra-operative (Neuro) | | | | | | | |
| | Laparoscopic | | | | | | | |
| Fetal<br>Imaging<br>& Other | Pediatric | | | | | | | |
| | Small Organ (Specify) | | | | | | | |
| | Neonatal Cephalic | N | N | N | N | N | | N |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | | | | | | | |
| | Trans-vaginal | | | | | | | |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skeletal<br>(Conventional) | | | | | | | |
| | Musculo-skeletal<br>(Superficial) | | | | | | | |
| | Intravascular | | | | | | | |
| | Other (Specify) | | | | | | | |
| | Cardiac Adult | N | N | N | N | N | | N |
| Cardiac | Cardiac Pediatric | N | N | N | N | N | | N |
| | Intravascular (Cardiac) | | | | | | | |
| | Trans-esoph. (Cardiac) | | | | | | | |
| | Intra-cardiac | | | | | | | |
| | Other (Specify) | | | | | | | |
| Peripheral<br>Vessel | Peripheral vessel | | | | | | | |
| | Other (Specify) | | | | | | | |
N = new indication; P = previously cleared by FDA; E = added under this appendix
* Other modes of operation include: CPA, Elastography, XBeam, Trapezoidal /Extended Sector Imaging Anatomical M-mode, TDI, ECG
{8}------------------------------------------------
#### 3.6 Transducer Indications for Use Form
#### Transducer: Endocavity V6LC
| Clinical Application | | Mode of Operation | | | | | | |
|-----------------------------|------------------------------------|-------------------|---|-----|-----|------------------|-----------------------|---------------------|
| General<br>(Track 1 Only) | Specific<br>(Tracks 1 & 3) | B | M | PWD | CWD | Color<br>Doppler | Combined<br>(Specify) | Other*<br>(Specify) |
| Ophthalmic | Ophthalmic | | | | | | | |
| | Fetal | N | N | N | | N | | N |
| | Abdominal | | | | | | | |
| | Intra-operative (Specify) | | | | | | | |
| | Intra-operative (Neuro) | | | | | | | |
| | Laparoscopic | | | | | | | |
| Fetal<br>Imaging<br>& Other | Pediatric | | | | | | | |
| | Small Organ (Specify) | | | | | | | |
| | Neonatal Cephalic | | | | | | | |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | N | N | N | | N | | N |
| | Trans-vaginal | N | N | N | | N | | N |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skeletal<br>(Conventional) | | | | | | | |
| | Musculo-skeletal<br>(Superficial) | | | | | | | |
| | Intravascular | | | | | | | |
| | Other (Specify) | N | N | N | | N | | N |
| | Cardiac Adult | | | | | | | |
| Cardiac | Cardiac Pediatric | | | | | | | |
| | Intravascular (Cardiac) | | | | | | | |
| | Trans-esoph. (Cardiac) | | | | | | | |
| | Intra-cardiac | | | | | | | |
| | Other (Specify) | | | | | | | |
| Peripheral<br>Vessel | Peripheral vessel | | | | | | | |
| | Other (Specify) | | | | | | | |
N = new indication; P = previously cleared by FDA; E = added under this appendix
* Other modes of operation include: CPA, 3-D Imaging, Elastography, XBeam, Panoscope, Trapezoidal /Extended Sector Imaging, Anatomical M-mode, ECG
Additional Comments: Other uses include: Gynecology, Urology, Prostate, Kidney, Uterus, Ovary
{9}------------------------------------------------
#### 3.7 Transducer Indications for Use Form
#### Transducer: Endocavity Biplane ECBP
| Clinical Application | | Mode of Operation | | | | | | |
|-----------------------------|------------------------------------|-------------------|---|-----|-----|------------------|-----------------------|---------------------|
| General<br>(Track 1 Only) | Specific<br>(Tracks 1 & 3) | B | M | PWD | CWD | Color<br>Doppler | Combined<br>(Specify) | Other*<br>(Specify) |
| Ophthalmic | Ophthalmic | | | | | | | |
| | Fetal | | | | | | | |
| | Abdominal | | | | | | | |
| | Intra-operative (Specify) | | | | | | | |
| | Intra-operative (Neuro) | | | | | | | |
| | Laparoscopic | | | | | | | |
| Fetal<br>Imaging<br>& Other | Pediatric | | | | | | | |
| | Small Organ (Specify) | | | | | | | |
| | Neonatal Cephalic | | | | | | | |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | N | N | N | | N | | N |
| | Trans-vaginal | N | N | N | | N | | N |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skeletal<br>(Conventional) | | | | | | | |
| | Musculo-skeletal<br>(Superficial) | | | | | | | |
| | Intravascular | | | | | | | |
| | Other (Specify) | N | N | N | | N | | N |
| | Cardiac Adult | | | | | | | |
| Cardiac | Cardiac Pediatric | | | | | | | |
| | Intravascular (Cardiac) | | | | | | | |
| | Trans-esoph. (Cardiac) | | | | | | | |
| | Intra-cardiac | | | | | | | |
| | Other (Specify) | | | | | | | |
| Peripheral<br>Vessel | Peripheral vessel | | | | | | | |
| | Other (Specify) | | | | | | | |
N = new indication; P = previously cleared by FDA; E = added under this appendix
* Other modes of operation include: CPA, 3-D Imaging, Elastography, XBeam, Panoscope, Trapezoidal / Extended Sector Imaging, Anatomical M-mode, ECG
Additional Comments: Other uses include: Urology, Prostate, Kidney, Uterus, Ovary
{10}------------------------------------------------
#### 3.8 Transducer Indications for Use Form
# Transducer: Linear Array L10LC
| Clinical Application | | Mode of Operation | | | | | | |
|-----------------------------|------------------------------------|-------------------|---|-----|-----|------------------|-----------------------|---------------------|
| General<br>(Track 1 Only) | Specific<br>(Tracks 1 & 3) | B | M | PWD | CWD | Color<br>Doppler | Combined<br>(Specify) | Other*<br>(Specify) |
| Ophthalmic | Ophthalmic | | | | | | | |
| | Fetal | | | | | | | |
| | Abdominal | | | | | | | |
| | Intra-operative (Specify) | | | | | | | |
| | Intra-operative (Neuro) | | | | | | | |
| | Laparoscopic | | | | | | | |
| Fetal<br>Imaging<br>& Other | Pediatric | N | N | N | | N | | |
| | Small Organ (Specify) | N | N | N | | N | | N |
| | Neonatal Cephalic | | | | | | | |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | | | | | | | |
| | Trans-vaginal | | | | | | | |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skeletal<br>(Conventional) | N | N | N | | N | | N |
| | Musculo-skeletal<br>(Superficial) | N | N | N | | N | | N |
| | Intravascular | | | | | | | |
| | Other (Specify) | | | | | | | |
| | Cardiac Adult | | | | | | | |
| Cardiac | Cardiac Pediatric | | | | | | | |
| | Intravascular (Cardiac) | | | | | | | |
| | Trans-esoph. (Cardiac) | | | | | | | |
| | Intra-cardiac | | | | | | | |
| | Other (Specify) | | | | | | | |
| Peripheral<br>Vessel | Peripheral vessel | N | N | N | | N | | |
| | Other (Specify) | | | | | | | |
N = new indication; P = previously cleared by FDA; E = added under this appendix
* Other modes of operation include: CPA, 3-D Imaging, Elastography, XBeam, Panoscope, Trapezoidal
/Extended Sector Imaging, Anatomical M-mode, ECG
Small organs include: Thyroid, Testes, Breast
{11}------------------------------------------------
#### 3.9 Transducer Indications for Use Form
#### Transducer: Endocavity Linear U5LC
| Clinical Application | | Mode of Operation | | | | | | |
|-----------------------------|------------------------------------|-------------------|---|-----|-----|------------------|-----------------------|---------------------|
| General<br>(Track 1 Only) | Specific<br>(Tracks 1 & 3) | B | M | PWD | CWD | Color<br>Doppler | Combined<br>(Specify) | Other*<br>(Specify) |
| Ophthalmic | Ophthalmic | | | | | | | |
| | Fetal | | | | | | | |
| | Abdominal | | | | | | | |
| | Intra-operative (Specify) | | | | | | | |
| | Intra-operative (Neuro) | | | | | | | |
| | Laparoscopic | | | | | | | |
| Fetal<br>Imaging<br>& Other | Pediatric | | | | | | | |
| | Small Organ (Specify) | | | | | | | |
| | Neonatal Cephalic | | | | | | | |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | N | N | N | | N | | N |
| | Trans-vaginal | N | N | N | | N | | N |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skeletal<br>(Conventional) | | | | | | | |
| | Musculo-skeletal<br>(Superficial) | | | | | | | |
| | Intravascular | | | | | | | |
| | Other (Specify) | N | N | N | | N | | N |
| | Cardiac Adult | | | | | | | |
| Cardiac | Cardiac Pediatric | | | | | | | |
| | Intravascular (Cardiac) | | | | | | | |
| | Trans-esoph. (Cardiac) | | | | | | | |
| | Intra-cardiac | | | | | | | |
| | Other (Specify) | | | | | | | |
| Peripheral<br>Vessel | Peripheral vessel | | | | | | | |
| | Other (Specify) | | | | | | | |
N = new indication; P = previously cleared by FDA; E = added under this appendix
* Other modes of operation include: CPA, 3-D Imaging, Elastography, XBeam, Panoscope, Trapezoidal /Extended Sector Imaging, Anatomical M-mode, ECG
Additional Comments: Other uses include: Gynecology, Urology, Prostate, Kidney, Uterus, Ovary
{12}------------------------------------------------
#### 3.10 Transducer Indications for Use Form
#### Transducer: Convex Array C6LC
| Clinical Application | | Mode of Operation | | | | | | |
|-----------------------------|------------------------------------|-------------------|---|-----|-----|------------------|-----------------------|---------------------|
| General<br>(Track 1 Only) | Specific<br>(Tracks 1 & 3) | B | M | PWD | CWD | Color<br>Doppler | Combined<br>(Specify) | Other*<br>(Specify) |
| Ophthalmic | Ophthalmic | | | | | | | |
| | Fetal | N | N | N | | N | | N |
| | Abdominal | N | N | N | | N | | N |
| | Intra-operative (Specify) | | | | | | | |
| | Intra-operative (Neuro) | | | | | | | |
| | Laparoscopic | | | | | | | |
| Fetal<br>Imaging<br>& Other | Pediatric | | | | | | | |
| | Small Organ (Specify) | | | | | | | |
| | Neonatal Cephalic | N | N | N | | N | | N |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | | | | | | | |
| | Trans-vaginal | | | | | | | |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skeletal<br>(Conventional) | | | | | | | |
| | Musculo-skeletal<br>(Superficial) | | | | | | | |
| | Intravascular | | | | | | | |
| | Other (Specify) | N | N | N | | N | | N |
| | Cardiac Adult | | | | | | | |
| Cardiac | Cardiac Pediatric | N | N | N | | N | | N |
| | Intravascular (Cardiac) | | | | | | | |
| | Trans-esoph. (Cardiac) | | | | | | | |
| | Intra-cardiac | | | | | | | |
| | Other (Specify) | | | | | | | |
| Peripheral | Peripheral vessel | | | | | | | |
| Vessel | Other (Specify) | | | | | | | |
N = new indication; P = previously cleared by FDA; E = added under this appendix
* Other modes of operation include: CPA, 3-D Imaging, Elastography, XBeam, Panoscope, Trapezoidal
/Extended Sector Imaging, Anatomical M-mode, ECG
Additional Comments: Other uses include: Gynecology, Urology, Prostate, Kidney, Uterus, Ovary
{13}------------------------------------------------
# 510(k) Summary
This summary of 510(k) safety and effectiveness information is provided in accordance with the requirements of SMDA 1990 and 21 CFR 807.92(c).
The assigned 510(k) number is: K160853
# 1. 510(k) Owner:
Shantou Institute of Ultrasonic Instruments Co., Ltd. (SIUI) 77 Jinsha Road, Shantou, Guangdong 515041, China Tel: 86-754-88250150 Fax: 86-754-88251499
# Contact Person:
Flower Cai
Shantou Institute of Ultrasonic Instruments Co., Ltd.
77 Jinsha Road, Shantou, Guangdong 515041, China
Date Prepared: March 24, 2016
# 2. Device/Trade Name:
Apogee 5500 Digital Color Doppler Ultrasound Imaging System Apogee 5300 Digital Color Doppler Ultrasound Imaging System Apogee 5800 Digital Color Doppler Ultrasound Imaging System
# Classification Name:
Regulatory Class: II
| Ultrasonic Pulsed Doppler Imaging System | 90-IYN (per 21 CFR 892.1550) |
|------------------------------------------|------------------------------|
| Ultrasonic Pulsed Echo Imaging System | 90-IYO (per 21 CFR 892.1560) |
| Diagnostic Ultrasound Transducer | 90-ITX (per 21 CFR 892.1570) |
{14}------------------------------------------------
# 3. Intended Use
The Apogee 5500/ Apogee 5300 /Apogee 5800 Digital Color Doppler Ultrasound Imaging System is intended for use by a qualified physician for ultrasound evaluation of Fetal, Abdominal, Pediatric, Small Organ (Thyroid, Testes, Breast), Neonatal Cephalic, Musculoskeletal (Conventional and Superficial), Cardiac (Adult and Pediatric), Peripheral Vascular, Trans-vaginal, Trans-rectal, Obstetrics/ Gynecology and Urology applications.
# 4. Device Description
The SIUI Apogee 5500/ Apogee 5300 /Apogee 5800 is a Digital Ultrasound Imaging System capable of the following operating modes: B-Mode(B, 2B, 4B), M-Mode, CFM, CPA, PWD, CWD, Combined(B, M, CFM, CPA, PWD, CWD, XBeam, Panoscope), and other(3D, 4D, Trapezoidal /Extended Sector Imaging, Elastography, Anatomical M-mode, TDI, MFI, ECG).The system is designed for use in linear, convex, phased array and 3D scanning modes and supports linear, convex, phased array, 3D and endocavity (trans-vaginal and trans-rectal) transducers. The system has cine review, image zoom, measurements and calculations, image storage and review, printing and recording capabilities.
#### Apogee 5500 vs. Apogee 5300:
#### The cosmetic structure designs are the same, except for the color of some structures.
- A Apogee 5500: the colors of speaker enclosure, keyboard cover board and elevation front and rear covers are dark gray, dark gray and white respectively.
- A Apogee 5300: the colors of speaker enclosure, keyboard cover board and elevation front and rear covers are all light gray.
# Apogee 5800 vs. Apogee 5500:
# The cosmetic and structure designs are basically the same. Main differences:
- A Apogee 5800: The cosmetic colors are pearl gray and white, and the dimensions are bigger. The overall shape is more plump and stable.
- A Apogee 5500: more delicate and concise.
{15}------------------------------------------------
Image /page/15/Figure/1 description: The image shows two different models of ultrasound imaging systems, the Apogee 5500 and the Apogee 5300 Digital Color Doppler Ultrasound Imaging System. The image also shows a close up of the side of one of the machines, with the brand name SIUI visible. The image has annotations pointing out that the two machines have different colors.
Apogee 5800 Digital Color Doppler Ultrasound Imaging System
{16}------------------------------------------------
# Comparison between: Apogee 5500, Apogee 5300 and Apogee 5800
- Overall dimensions: Subject to market positioning, the overall dimensions of Apogee 5500 and Apogee 5300 are smaller than Apogee 5800.
- Chassis: Subject to market positioning, the dimensions and structures of the chassis for Apogee 5500, Apogee 5300 and Apogee 5800 are different.
- Internal module structure: The internal modules are the same, and the main difference is in the expansion space. The Apogee 5800 has bigger size, enabling the placement of some accessories such as cables. Both the left and right sides of Apogee 5800 have the additional glove compartments.
- Transducer socket position: Apogee 5500 and Apogee 5300: on the right of the main unit, Apogee 5800: at the middle front of the main unit
- Touch screen and monitor: the same. They all use a 10.4-inch touch screen and a 19-inch monitor.
- Call situations of some functional buttons on the control panels are modified.
- Functional Configuration: Subject to market positioning, the Apogee 5500/ Apogee 5300/ Apogee 5800 have different functional configurations. See the details in the table below.
| Functional<br>Configuration | Apogee 5500 | Apogee 5300 | Apogee 5800 |
|--------------------------------------------|-------------|-------------|-------------|
| B | √ | √ | √ |
| 2B | √ | √ | √ |
| 4B | √ | √ | √ |
| B/M | √ | √ | √ |
| M | √ | √ | √ |
| PW | √ | √ | √ |
| B+CFM | √ | √ | √ |
| B+CPA | √ | √ | √ |
| B+PW | √ | √ | √ |
| Triplex<br>(B+CFM+PW,<br>B+CPA+PW) | √ | √ | √ |
| Trapezoidal<br>/Extended Sector<br>Imaging | √ | √ | √ |
| XBeam | √ | √ | √ |
| Panoscope | √ | √ | √ |
| Anatomical<br>M-mode | √ | √ | √ |
{17}------------------------------------------------
| CW | √ | √ | √ |
|--------------|---|---|---|
| 3D | √ | O | √ |
| 4D | √ | √ | √ |
| TDI | √ | O | √ |
| Elastography | O | O | O |
| MFI | √ | √ | √ |
| ECG | O | O | √ |
Notes: √ for standard configuration, and ○ for optional purchase.
# 5. Legally Marketed Predicate Devices and Substantial Equivalence
The Apogee 5500/ Apogee 5300 /Apogee 5800 Digital Color Doppler Ultrasound Imaging Systems are multi-purpose diagnostic ultrasound systems with accessories and proprietary software, and are substantially equivalent to these predicate devices:
| Predicate<br>Device | Manufacturer | Model | 510(k)<br>Number |
|---------------------|--------------|----------------------------------------------------------------|------------------|
| 1 | SIUI | Apogee 3800 Digital Color Doppler<br>Ultrasound Imaging System | K110841 |
| 2 | SIEMENS | Acuson X700<br>Diagnostic Ultrasound System | K141846 |
# 5.1 Comparison of Indications for Use (IFU)
#### A IFU Statement
The subject device Apogee 5500/ Apogee 5300 /Apogee 5800 Digital Color Doppler Ultrasound Imaging System is intended for use by a qualified physician for ultrasound evaluation of Fetal, Abdominal, Pediatric, Small Organ (Thyroid, Testes, Breast), Neonatal Cephalic, Musculoskeletal (Conventional and Superficial), Cardiac (Adult Pediatric), Peripheral Vascular, Trans-vaginal, Trans-rectal, and Obstetrics/ Gynecology and Urology applications.
The predicate device Apogee 3800 Digital Color Doppler Ultrasound Imaging System (K110841) is intended for diagnostic ultrasonic imaging for abdominal, pediatric, small organ, musculo-skeletal, cardiac, peripheral vascular applications in B, M, PWD, Color Doppler and 3D imaging modes.
The predicate device SIEMENS Acuson X700 and X600 ultrasound imaging system
{18}------------------------------------------------
(K141846) "is intended for the following applications: Cardiac (Adult, Pediatric), Transesophageal (Cardiac), Intracardiac. Cerebrovascular, Peripheral Vessel, Abdominal, Renal, Fetal, Abdominal, Intra-operative, Pediatric, Small Organ, Neonatal Cephalic, Adult Cephalic, Orthopedics, Musculo-skeletal Conventional, Musculo-skeletal Superficial, Pelvic, Obstetrical, Gynecological and Urological applications.
The system also provides for the measurement of anatomical structures and for analysis packages that provide information that is used for clinical diagnosis purposes.
The Arterial Health Package (AHP) software provides the physician with the capability to measure Intima Media Thickness and the option to reference normative tables that have been validated and published in peer-reviewed studies. The information is intended to provide the physician with an easily understood tool for communicating with patients regarding state of their cardiovascular system. This feature should be utilized according to the "ASE Consensus Statement; Use of Carotid Ultrasound to Identify Subclinical Vascular Disease and Evaluate Cardiovascular Disease Risk: A Consensus Statement from the American Association of Echocardiography: Carotid Intima-Media Thickness Task Force, Endorsed by the Society for Vascular Imaging.
The Acuson Acunav and Soundstar Ultrasound Catheter are intended for intra-cardiac and intraluminal visualization of cardiac and great vessel anatomy and physiology, as well as visualization of other devices in the heart of adult and pediatric patients. "
#### A Application
The Apogee 5500/ Apogee 5300 /Apogee 5800 and the predicate Apogee 3800 (K110841) have the same applications except for 5 additional applications in the subject device: Neonatal Cephalic, Trans-vaginal, Trans-rectal, Gynecology and Urology. All the applications of the subject device Apogee 5500/ Apogee 5300 /Apogee 5800 are included in the applications of predicate Acuson X700 (K141846).
#### A Display Mode
The Apogee 5500/ Apogee 5300 /Apogee 5800 and the predicate Apogee 3800 (K110841) have the same technological characteristics, are comparable in key safety and effectiveness features, and have the same basic operating modes. All systems
{19}------------------------------------------------
transmit ultrasonic energy into patients, perform post processing of received echoes to generate onscreen display of anatomic structures and fluid flow within the body.
Based on the same principle, the front-end transmit circuit controls are similar. After various post-processing for the acquired information data, the subject device Apogee 5500/ Apogee 5300 /Apogee 5800 has new imaging modes (XBeam, Panoscope, 4D, Trapezoidal / Extended Sector Imaging, Elastography, Anatomical M-mode, TDI, MFI), as well as the addition of ECG application circuit and function. The new imaging modes, which are similar to the predicate Acuson X700 (K141846), were tested and proved no impact on device safety and effectiveness.
#### A Measurement and reporting
The Apogee 5500/ Apogee 5300 /Apogee 5800 and the predicate Apogee 3800 (K110841) have the same measurement functions, measurement packages and reporting functions.
# 5.2 Comparison with the predicate device SIUI Apogee 3800 (K110841)
The Apogee 5500, Apogee 5300 and Apogee 5800 mainly have cosmetic changes based on SIUI Apogee 3800 (K110841), with additional new features and new configurable transducers.
- 1) In cosmetic design, the Apogee 5800 is close to the Apogee 3800, except for changes in some structure of the upper part of the machine and some adjustment on the control panel. Both Apogee 5500 and Apogee 5300 have slimmer cosmetic design to adapt to clinical application in smaller space, and the probe sockets are changed from the middle front to the right of the main unit, the locations of I/O panel, keyboard are changed accordingly, but the corresponding interfaces and circuit principle are not changed.
- In new features, the Apogee 5500/ Apogee 5300/ Apogee 5800 have additional CWD, 2) 3D, 4D, Trapezoidal /Extended Sector Imaging, Elastography, Anatomical M-mode, TDI, MFI and ECG (identical to Acuson X700 K141846).
- In probe configuration, the Apogee 5500/ Apogee 5300/ Apogee 5800 have additional 3) V6LC, ECBP, L10LC, C6LC, U5LC transducers (identical to Acuson X700 K141846),
{20}------------------------------------------------
and the range of application includes 5 additional exams Neonatal Cephalic, Trans-vaginal and Trans-rectal. Gynecology and Urology (identical to Acuson X700 K141846).
The SIUI Apogee 5500/ Apogee 5300/ Apogee 5800 are similar in technological characteristics to the SIUI Apogee 3800.
# 5.3 Comparison with the predicate device SIEMENS Acuson X700 (K141846)
For the technical specifications and transducers on the SIUI Apogee 5500/ Apogee 5300/ Apogee 5800, the claim of substantial equivalence to devices currently having FDA 510(k) clearance is Siemens Acuson X700 (K141846).
The SIUI Apogee 5500/ Apogee 5300/ Apogee 5800 is similar in technological characteristics to the Siemens Acuson X700.
- A The SIUI Apogee 5500/ Apogee 5300/ Apogee 5800 and the Siemens Acuson X700 have similar imaging modes.
- A The SIUI Apogee 5500/ Apogee 5300/ Apogee 5800 and the Siemens Acuson X700 have similar diagnostic ultrasound applications
- A The transducers of SIUI Apogee 5500/ Apogee 5300/ Apogee 5800 and the Siemens Acuson X700 have similar technical parameters and hardware implementation principle.
- A The SIUI Apogee 5500/ Apogee 5300/ Apogee 5800 have similar diagnostic ultrasound applications as Siemens Acuson X700.
# 6. Safety Considerations
The Apogee 5500/ Apogee 5300 /Apogee 5800 Digital Color Doppler Ultrasound Imaging System has been tested per the FDA Guidance document "Information for Manufacturers Seeking Marketing Clearance of Diagnostic Ultrasound Systems and Transducers" issued in September 2008. The acoustic output is measured and calculated per NEMA UD 2 Acoustic Output Measurement Standard for Diagnostic Ultrasound Equipment: 2004. The device conforms to applicable medical device safety standards, such as IEC 60601-1, ISO10993-5 and ISO 10993-10.
{21}------------------------------------------------
# 7. Conclusion
The conclusions drawn from testing of the Apogee 5500/ Apogee 5300 /Apogee 5800 Digital Color Doppler Ultrasound Imaging System demonstrates that the device is as safe and effective as the legally marketed predicate devices.
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.