CustomizedBone Service

K160707 · Fin-Ceramica Faenza S.P.A. · GXN · Dec 17, 2016 · Neurology

Device Facts

Record IDK160707
Device NameCustomizedBone Service
ApplicantFin-Ceramica Faenza S.P.A.
Product CodeGXN · Neurology
Decision DateDec 17, 2016
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 882.5330
Device ClassClass 2
AttributesTherapeutic, Pediatric

Indications for Use

CustomizedBone Service (CustomizedBone) is intended to replace bony voids in the craniofacial skeleton (frontal bone including the brow ridge). This device is indicated for both adult and pediatric use (for children above 13 years of age). CustomizedBone implants are suitable for reconstructing craniofacial defects resulting from: - trauma and vascular pathologies, either associated or non-associated to cranial decompression; - removal of tumors; - reabsorption of autologous bone; - rejection of other prosthetic materials; - congenital malformations.

Device Story

CustomizedBone Service provides patient-specific implants for craniofacial reconstruction. The service utilizes patient imaging data to design and manufacture custom implants tailored to the patient's specific bony defect. These implants are intended to replace bony voids in the frontal bone and brow ridge. The device is used by surgeons in a clinical setting to restore cranial anatomy following trauma, tumor resection, or other pathologies. By providing a precise, anatomically matched implant, the service aims to improve surgical outcomes and patient recovery compared to standard off-the-shelf prosthetic materials.

Indications for Use

Indicated for adult and pediatric patients (>13 years) requiring reconstruction of craniofacial bony voids (frontal bone/brow ridge) caused by trauma, vascular pathologies, tumor removal, autologous bone reabsorption, prosthetic rejection, or congenital malformations.

Regulatory Classification

Identification

A preformed nonalterable cranioplasty plate is a device that is implanted in a patient to repair a skull defect and is constructed of a material, e.g., stainless steel or vitallium, that cannot be altered or reshaped at the time of surgery without changing the chemical behavior of the material.

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/1 description: The image shows the seal of the U.S. Department of Health & Human Services. The seal features a stylized eagle-like design with three wavy lines extending from its head. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular pattern around the emblem. Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002 December 17, 2016 FIN-CERAMICA FAENZA SPA % Mary Beth Henderson, PhD, MBA VP Regulatory Affairs & Quality Systems, Senior Principal Advisor Regulatory & Clinical Research Institute, Inc. 5353 Wayzata Blvd., Suite 505 Minneapolis, Minnesota 55416-1334 Re: K160707 Trade/Device Name: CustomizedBone Service Regulation Number: 21 CFR 882.5330 Regulation Name: Preformed Nonalterable Cranioplasty Plate Regulatory Class: Class II Product Code: GXN, PJN Dated: November 7, 2016 Received: November 8, 2016 Dear Dr. Henderson: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration. listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you; however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical devicerelated adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in {1}------------------------------------------------ the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Sincerely yours, # MichaelJ. Hoffmann -S Carlos L. Peña, PhD, MS for Director Division of Neurological and Physical Medicine Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ # Indications for Use 510(k) Number (if known) K160707 Device Name CustomizedBone Service #### Indications for Use (Describe) CustomizedBone Service (CustomizedBone) is intended to replace bony voids in the craniofacial skeleton (frontal bone including the brow ridge). This device is indicated for both adult and pediatric use (for children above 13 years of age). CustomizedBone implants are suitable for reconstructing craniofacial defects resulting from: - · trauma and vascular pathologies, either associated or non-associated to cranial decompression; - · removal of tumors; - · reabsorption of autologous bone; - · rejection of other prosthetic materials; - · congenital malformations. Type of Use (Select one or both, as applicable) | <div style="display:inline-block;"><input checked="true" type="checkbox"/></div> Production Use (21 CFR 601 Subpart D) | <div style="display:inline-block;"><input type="checkbox"/></div> Compassionate Use (21 CFR 601 Subpart E) | |------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------| |------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------| > Prescription Use (Part 21 CFR 801 Subpart D) | | Over-The-Counter Use (21 CFR 801 Subpart C) ## CONTINUE ON A SEPARATE PAGE IF NEEDED. This section applies only to requirements of the Paperwork Reduction Act of 1995. ### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.* The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: > Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...