Ritter Dental Implant System
Device Facts
| Record ID | K160475 |
|---|---|
| Device Name | Ritter Dental Implant System |
| Applicant | Ritter Implants GmbH & Co. KG |
| Product Code | DZE · Dental |
| Decision Date | Dec 14, 2016 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 872.3640 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
The Ritter Dental Implant System is intended to replace one or more missing teeth in the upper or lower jaw in order to restore a patient's chewing function. The abutments are used with endosseous dental implants to support a prosthetic device in a partially or edentulous patients. The Ritter Dental Implant System is intended to support single and multiple tooth prostheses, in the mandible or maxilla. The prostheses can be screw or cement retained to the abutment. The Ritter Dental Implant System is intended for immediate loading when good primary stability is achieved and with appropriate occlusal loading.
Device Story
Ritter Dental Implant System consists of endosseous dental implants and abutments; used to replace missing teeth in mandible or maxilla. Implants surgically placed in jawbone; abutments attached to support screw-retained or cement-retained prostheses. System supports immediate loading if primary stability and occlusal conditions are met. Used by dental professionals in clinical settings to restore chewing function and aesthetics for patients with tooth loss.
Clinical Evidence
No clinical data provided; bench testing only.
Technological Characteristics
Endosseous dental implant system; includes implants and abutments for prosthetic support. Designed for surgical implantation in the jawbone.
Indications for Use
Indicated for patients with missing teeth in the upper or lower jaw (partially or fully edentulous) requiring restoration of chewing function via single or multiple tooth prostheses.
Regulatory Classification
Identification
An endosseous dental implant is a prescription device made of a material such as titanium or titanium alloy that is intended to be surgically placed in the bone of the upper or lower jaw arches to provide support for prosthetic devices, such as artificial teeth, in order to restore a patient's chewing function.
Special Controls
*Classification.* (1) Class II (special controls). The device is classified as class II if it is a root-form endosseous dental implant. The root-form endosseous dental implant is characterized by four geometrically distinct types: Basket, screw, solid cylinder, and hollow cylinder. The guidance document entitled “Class II Special Controls Guidance Document: Root-Form Endosseous Dental Implants and Endosseous Dental Implant Abutments” will serve as the special control. (See § 872.1(e) for the availability of this guidance document.)(2) *Classification.* Class II (special controls). The device is classified as class II if it is a blade-form endosseous dental implant. The special controls for this device are:(i) The design characteristics of the device must ensure that the geometry and material composition are consistent with the intended use; (ii) Mechanical performance (fatigue) testing under simulated physiological conditions to demonstrate maximum load (endurance limit) when the device is subjected to compressive and shear loads; (iii) Corrosion testing under simulated physiological conditions to demonstrate corrosion potential of each metal or alloy, couple potential for an assembled dissimilar metal implant system, and corrosion rate for an assembled dissimilar metal implant system; (iv) The device must be demonstrated to be biocompatible; (v) Sterility testing must demonstrate the sterility of the device; (vi) Performance testing to evaluate the compatibility of the device in a magnetic resonance (MR) environment; (vii) Labeling must include a clear description of the technological features, how the device should be used in patients, detailed surgical protocol and restoration procedures, relevant precautions and warnings based on the clinical use of the device, and qualifications and training requirements for device users including technicians and clinicians; (viii) Patient labeling must contain a description of how the device works, how the device is placed, how the patient needs to care for the implant, possible adverse events and how to report any complications; and (ix) Documented clinical experience must demonstrate safe and effective use and capture any adverse events observed during clinical use.