← Product Code [HRS](/productcode/HRS) · K153034

# aap LOQTEQ VA Radius Set 2.5 (K153034)

_Aap Implantate AG · HRS · Jan 21, 2016 · Orthopedic · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K153034

## Device Facts

- **Applicant:** Aap Implantate AG
- **Product Code:** [HRS](/productcode/HRS.md)
- **Decision Date:** Jan 21, 2016
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 888.3030
- **Device Class:** Class 2
- **Review Panel:** Orthopedic
- **Attributes:** Therapeutic

## Indications for Use

LOQTEQ® VA Volar Distal Radius Plate 2.5, LOQTEQ® VA Distal Radius Straight Plate 2.5, LOQTEQ® VA Distal Radius L-Plate 2.5 · Fixation of complex intra-articular and extra-articular fractures and osteotomies of the distal radius LOQTEQ® VA Distal Ulna Plate 2.5, LOQTEQ® VA Distal Ulna Hook Plate 2.5 · Fractures and osteotomies of the distal ulna

## Device Story

aap LOQTEQ® VA Radius Set 2.5 comprises metallic bone plates and screws for internal fixation of distal radius and ulna fractures/osteotomies. Surgeon implants device to stabilize bone fragments; locking screws create internal fixator construct. Used in clinical/surgical settings. Output is mechanical stabilization of bone; aids healing by maintaining alignment. Benefits patient through restoration of skeletal integrity.

## Clinical Evidence

Bench testing only. Static and dynamic system tests performed representing worst-case clinical scenarios. Screw testing conducted per ASTM F543-13. Results demonstrate mechanical performance meets pre-defined acceptance criteria.

## Technological Characteristics

Metallic bone fixation system. Materials: Ti6Al4V (ASTM F136/ISO 5832-3) and unalloyed Titanium (ASTM F67/ISO 5832-2). Includes various plates (Volar, Straight, L-Plate, Ulna, Hook) and 2.5mm cortical screws. Mechanical performance validated via ASTM F543-13.

## Regulatory Identification

Single/multiple component metallic bone fixation appliances and accessories are devices intended to be implanted consisting of one or more metallic components and their metallic fasteners. The devices contain a plate, a nail/plate combination, or a blade/plate combination that are made of alloys, such as cobalt-chromium-molybdenum, stainless steel, and titanium, that are intended to be held in position with fasteners, such as screws and nails, or bolts, nuts, and washers. These devices are used for fixation of fractures of the proximal or distal end of long bones, such as intracapsular, intertrochanteric, intercervical, supracondylar, or condylar fractures of the femur; for fusion of a joint; or for surgical procedures that involve cutting a bone. The devices may be implanted or attached through the skin so that a pulling force (traction) may be applied to the skeletal system.

## Predicate Devices

- Synthes (USA) Variable Angle LCP Dorsal Distal Radius System ([K102694](/device/K102694.md))
- Synthes (USA) LCP Diaphyeal-Metaphyseal (Dia-Meta) Volar Distal Radius Plate ([K070946](/device/K070946.md))
- Synthes (USA) VA LCP Two-Column Volar Distal Radius Plates ([K083694](/device/K083694.md))
- Medartis AG APTUS Ulna Plates ([K103332](/device/K103332.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular border with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" written around it. Inside the circle is a stylized image of three human profiles facing right, stacked on top of each other, with flowing lines connecting them.

Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002

January 21, 2016

aap Implantate Ag Dr. Christian Zietsch Director Quality Assurance and Regulatory Affairs Lorenzweg 5 Berlin, D-12099 GERMANY

Re: K153034 Trade/Device Name: aap LOQTEQ® VA Radius Set 2.5 Regulation Number: 21 CFR 888.3030 Regulation Name: Single/multiple component metallic bone fixation appliances and accessories Regulatory Class: Class II Product Code: HRS, HWC Dated: October 20, 2015 Received: October 23, 2015

Dear Dr. Zietsch:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug. and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Parts 801); medical device reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set

{1}------------------------------------------------

forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address

http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to

http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.

You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address

http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.

Sincerely yours,

# Lori A. Wiggins -S

for

Mark N. Melkerson Director Division of Orthopedic Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{2}------------------------------------------------

DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration

### Indications for Use

510(k) Number (if known) K153034

Device Name aap LOOTEO® VA Radius Set 2.5

Indications for Use (Describe)

LOQTEQ® VA Volar Distal Radius Plate 2.5, LOQTEQ® VA Distal Radius Straight Plate 2.5,

LOQTEQ® VA Distal Radius L-Plate 2.5

· Fixation of complex intra-articular and extra-articular fractures and osteotomies of the distal radius

LOQTEQ® VA Distal Ulna Plate 2.5,

LOQTEQ® VA Distal Ulna Hook Plate 2.5

• Fractures and osteotomies of the distal ulna

Type of Use (Select one or both, as applicable)

> Prescription Use (Part 21 CFR 801 Subpart D)

| Over-The-Counter Use (21 CFR 801 Subpart C)

#### CONTINUE ON A SEPARATE PAGE IF NEEDED.

This section applies only to requirements of the Paperwork Reduction Act of 1995.

#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*

The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:

> Department of Health and Human Services Food and Druq Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov

"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."

{3}------------------------------------------------

## 5. Summary of Safety and Effectiveness

| Sponsor:                                  | aap Implantate AG<br>Lorenzweg 5<br>D-12099 Berlin, Germany                                                                                                                                                                                                                                                                                                                                                                                                                                         |
|-------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Company Contact:                          | Dr. Christian Zietsch<br>Phone:+49-30-750-19 - 193<br>Fax: +49-30-750-19 – 111                                                                                                                                                                                                                                                                                                                                                                                                                      |
| Date                                      | Jan/21/2016                                                                                                                                                                                                                                                                                                                                                                                                                                                                                         |
| Trade Name:                               | aap LOQTEQ® VA Radius Set 2.5                                                                                                                                                                                                                                                                                                                                                                                                                                                                       |
| Common Name:                              | Variable Angle Distal Radius/Ulna Plates and Screws 2.5                                                                                                                                                                                                                                                                                                                                                                                                                                             |
| Classification Name and<br>Reference:     | 21 CFR 888.3030 Single/multiple component metallic bone<br>fixation appliances and accessories - Class II<br>21 CFR 888.3040 Smooth or threaded metallic bone fixa-<br>tion fastener - Class II                                                                                                                                                                                                                                                                                                     |
| Device Product<br>Code<br>and Panel Code: | Orthopedics/87/HRS<br>Orthopedics/87/HWC                                                                                                                                                                                                                                                                                                                                                                                                                                                            |
| Predicate devices                         | Synthes (USA) Variable Angle LCP Dorsal Distal Radius<br>System under the premarket notification K102694 (Dec 09,<br>2010)<br>Synthes (USA) LCP Diaphyeal-Metaphyseal (Dia-Meta)<br>Volar Distal Radius Plate under the premarket notification<br>K070946 (Jun 06, 2007)<br>Synthes (USA) VA LCP Two-Column Volar Distal Radius<br>Plates under the premarket notification K083694 (MAR 06,<br>2009)<br>Medartis AG APTUS Ulna Plates under the premarket noti-<br>fication K103332 (Jan 24, 2011). |
| Device Description:                       | The aap LOQTEQ® VA Radius Set 2.5 consists of bone<br>plates and bone screws, to be implanted by a surgeon in<br>order to achieve an internal fixation of bone fragments typi-<br>cally after fractures, osteotomies. If the plates are used in<br>conjunction with locking screws, a so called internal fixator<br>will be realized (internal fixation).                                                                                                                                           |

{4}------------------------------------------------

The aap LOQTEQ® VA Radius Set 2.5 incorporates:

|                                                  | <ul><li>LOQTEQ® VA Volar Distal Radius Plate 2.5, narrow/broad, right/left</li><li>LOQTEQ® VA Volar Distal Radius Plate 2.5, narrow, XL, right/left</li><li>LOQTEQ® VA Distal Radius Straight Plate 2.5</li><li>LOQTEQ® VA Distal Radius L-Plate 2.5, right/left</li><li>LOQTEQ® VA Distal Ulna Plate 2.5</li><li>LOQTEQ® VA Distal Ulna Hook Plate 2.5</li><li>LOQTEQ® VA Cortical Screw 2.5, T8</li><li>Cortical Screw 2.5, small head, T8, self-tapping</li><li>Set of Instruments LOQTEQ® VA Distal Radius Set 2.5</li></ul>                                                                                                                                                                                                                                                                                                                       |
|--------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Material:                                        | Ti6Al4V (ASTM F136 or ISO 5832-3) unalloyed Titanium (ASTM F67 or ISO 5832-2)                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                          |
| Indications:                                     | The aap LOQTEQ® VA Volar Distal Radius Plate 2.5, LO- QTEQ® VA Distal Radius Straight Plate 2.5, LOQTEQ® VA Distal Radius L-Plate 2.5 are intended for <b>fixation of complex intra-articular and extra-articular fractures and osteotomies of the distal radius</b> . The aap LOQTEQ® VA Distal Ulna Plate 2.5, LOQTEQ® VA Distal Ulna Hook Plate 2.5 are intended for <b>fractures and osteotomies of the distal ulna</b> .                                                                                                                                                                                                                                                                                                                                                                                                                          |
| Substantial Equivalence                          | The Substantial Equivalence of the new device and the predicate device is based on similar intended use, design, functionality, components and materials in use. Documentation including mechanical testing to show the substantial equivalence has been provided with this submission.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                |
| Performance Data (Non-Clinical and/or Clinical): | Non-clinical tests have been performed and show the substantial equivalence of the device. <u>Summary of Non-clinical tests</u> : <u>Type of test</u> : Static and dynamic system tests, representing worst case scenario with respect to clinical use.             Screw tests according to ASTM F543 – 13. <u>Assessment of test results</u> : Substantial equivalence with respect to the mechanical performance of the aap system could be stated due to the test results gained. The screws fulfil the relevant demands of ASTM F543-13. The subject device is safe and effective, and whose performance meets the requirements of its pre-defined acceptance criteria and intended uses. Documentation regarding the mechanical testing to show the substantial equivalence and safety and effectiveness has been provided with this submission. |

---

**Source:** [https://fda-staging.innolitics.com/device/K153034](https://fda-staging.innolitics.com/device/K153034)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).