K152757 · Sign Fracture Care International · HSB · Nov 13, 2015 · Orthopedic
Device Facts
Record ID
K152757
Device Name
SIGN Hip Construct (SHC)
Applicant
Sign Fracture Care International
Product Code
HSB · Orthopedic
Decision Date
Nov 13, 2015
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 888.3020
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
Indications for the SIGN Hip Construct (SHC) include all peritrochanteric, reverse oblique, subtrochanteric fractures and osteotomies in the proximal femur, with proper soft tissue management.
Device Story
Internal fixation system for proximal femur fractures; components include intramedullary nails (Standard and Fin), bone plates, interlocking screws, compression screws, and bone screws. Used in surgical settings by orthopedic surgeons to stabilize fractures and osteotomies. Device provides mechanical support to bone segments during healing process. Implants are stainless steel, single-use, and provided non-sterile. Surgeon selects appropriate nail length and plate configuration based on fracture type and patient anatomy. Output is physical stabilization of bone; facilitates fracture consolidation. Benefits include restoration of structural integrity to proximal femur.
Clinical Evidence
Bench testing only. Cyclic fatigue testing performed to simulate walking gait and validate device durability until fracture consolidation. Results demonstrated safety and effectiveness comparable to predicate devices.
Technological Characteristics
Materials: Stainless steel (ASTM F138 or F139). Components: Intramedullary nails, bone plates, interlocking/compression/bone screws. Design: Mechanical fixation system. Connectivity: None. Sterilization: Provided non-sterile (requires user sterilization).
Indications for Use
Indicated for patients with peritrochanteric, reverse oblique, subtrochanteric fractures, and osteotomies in the proximal femur requiring internal fixation.
Regulatory Classification
Identification
An intramedullary fixation rod is a device intended to be implanted that consists of a rod made of alloys such as cobalt-chromium-molybdenum and stainless steel. It is inserted into the medullary (bone marrow) canal of long bones for the fixation of fractures.
{0}------------------------------------------------
Image /page/0/Picture/1 description: The image shows the seal of the Department of Health & Human Services (HHS). The seal features the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged in a circular pattern around a central emblem. The emblem consists of a stylized design of three human profiles facing right, with flowing lines beneath them, resembling a bird or abstract form.
Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002
November 13, 2015
SIGN Fracture Care International Mr. Rob Teeter Regulatory Affairs/Quality Assurance Manager 451 Hills Street, Suite B Richland, Washington 99354
Re: K152757
Trade/Device Name: Sign Hip Construct (SHC) Regulation Number: 21 CFR 888.3020 Regulation Name: Intramedullary fixation rod Regulatory Class: Class II Product Code: HSB, KTT, HRS Dated: September 24, 2015 Received: September 24, 2015
Dear Mr. Teeter:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Parts 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set
{1}------------------------------------------------
forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled. "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.
Sincerely yours,
# Mark N. Melkerson -S
Mark N. Melkerson Director Division of Orthopedic Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
#### Indications for Use
510(k) Number (if known) K 152757
Device Name SIGN Hip Construct (SHC)
Indications for Use (Describe)
Indications for the SIGN Hip Construct (SHC) include all peritrochanteric, reverse oblique, subtrochanteric fractures and osteotomies in the proximal femur, with proper soft tissue management.
Type of Use (Select one or both, as applicable)
> Prescription Use (Part 21 CFR 801 Subpart D)
_ Over-The-Counter Use (21 CFR 801 Subpart C)
#### CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
{3}------------------------------------------------
Image /page/3/Picture/0 description: The image contains the logo for SIGN Fracture Care International. The logo features a stylized green figure running or leaping, positioned to the left of the word "SIGN" in bold, black letters. Below "SIGN" are the words "FRACTURE CARE" in a smaller font, followed by "INTERNATIONAL" in an even smaller font. The overall design is clean and professional, conveying a sense of movement and global reach.
## 510(k) Summary
| 510(k) Submitter: | SIGN Fracture Care International<br>451 Hills Street, Suite B<br>Richland, WA 99354 |
|----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------|
| Establishment #: | 3034525 |
| Contact Person: | Rob Teeter, Regulatory Affairs / Quality Assurance Manager<br>Phone: 509-371-1107<br>Fax: 509-371-1316<br>E-Mail: Rob.Teeter@signfracturecare.org |
| Date Prepared: | September 8, 2015 |
| Regulatory Class: | Class II |
| Panel: | Orthopedic |
| Trade Name: | SIGN Hip Construct (SHC) |
| Common Name: | Hip Fixation System |
| Classification Name: | 21CFR 888.3020: Intramedullary fixation rod |
| Device Product Code: | HSB, KTT, HRS |
Predicate Device: The SIGN Hip Construct (SHC) is similar in design, function, and use to the following fixation devices.
SIGN Hip Construct (SHC) (K083582) - Primary Predicate SIGN IM Nail (K022632) Synthes 6.5mm Cannulated Screw (K021932)
### Device Description
The SHC is an internal fixation device consisting of multiple components; Standard Hip Nail, Fin Hip Nail (Intramedullary Nails), Bone Plates, Interlocking Screws, Compression Screws, Bone Screws, and a set of Surgical Instruments. Each implant component is made from Stainless Steel, per requirements in ASTM F138 or F139. All implants are single use and provided nonsterile.
### Intended Use
Indications for the SIGN Hip Construct (SHC) include all peritrochanteric, reverse oblique, subtrochanteric fractures and osteotomies in the proximal femur, with proper soft tissue management.
{4}------------------------------------------------
Image /page/4/Picture/0 description: The image shows the logo for SIGN Fracture Care International. On the left side of the logo is a green graphic of a person running. To the right of the graphic is the word "SIGN" in bold, black letters. Below the word "SIGN" are the words "FRACTURE CARE INTERNATIONAL" in a smaller, gray font.
The Indications for Use statement is not identical to the predicate device: however, the differences do not alter the intended use of the device nor do they affect the safety and effectiveness of the device relative to the predicate. Both the subject and predicate devices share the intended use of treating proximal femur fractures.
## Substantial Equivalence Comparison
The SIGN Hip Construct (SHC) is substantially equivalent to the predicate SHC in design, performance, functions, and intended use. The safety and effectiveness of the SHC is also based on a history of use of this device in SIGN Humanitarian Programs.
The proposed device is very similar to the predicate Hip Construct. The difference in indications is that they have expanded to include reverse oblique fractures, and osteotomies. Osteotomies can be described as a deliberate fracture of the subtrochanteric region, which was already included as an indication of the predicate device. Reverse oblique fractures are commonly treated with intramedullary nails and systems such as the predicate SHC. These differences in indication are not critical to the surgical use of the device.
The modified device adds the option of a hip IM nail with standard interlocking and an updated plate design which allows for less prominence from the bone. The SIGN IM Nail was included as a predicate because it uses the same interlocking features and encompasses the size range of the proposed device.
## Comparison of Technological Characteristics
The predicate and proposed devices have a similar intended use and basic fundamental scientific technology and share the following similarities.
- Similar indications for use
- Similar design features
- Incorporate the same or similar materials
- . Equivalent mechanical performance, based on intended use
Though the proposed modified SHC device has features largely similar to the predicate SHC, the additional lengths and expanded indications prompted non-clinical performance testing. The predicate SHC device only includes an IM Nail length of 240mm but the SIGN IM Nail design incorporates nails up to 420mm in length, therefore it was included as a predicate and non-clinical testing was performed to ensure safety and effectiveness.
### Performance Data (non-clinical)
Fatigue tests simulating walking gait were performed to validate that the device can withstand patient use until fracture consolidation occurs. The primary predicate device was cleared in part based on the results of bench testing. These bench tests were duplicated using the modified
{5}------------------------------------------------
Image /page/5/Picture/0 description: The image contains the logo for SIGN Fracture Care International. On the left is a green rectangle with a white silhouette of a person running. To the right of the rectangle is the word "SIGN" in large, bold, black letters. Below the word "SIGN" are the words "FRACTURE CARE" in smaller, gray letters, and below that is the word "INTERNATIONAL" in the same font and color.
device. Specific tests performed include cyclic fatigue testing. The results did not raise any issues on the safety or effectiveness of the device.
### Conclusion
The testing data and design information provided in this submission indicate that the proposed device is safe and effective, and performs as well or better than the predicates. This supports the conclusion that the SIGN Hip Construct (SHC) is substantially equivalent to its predicate device.
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.