Balanced Knee System TriMax CR Femoral Component and E-Vitalize CR and UC Tibial Inserts
K152169 · Ortho Development Corporation · JWH · Oct 27, 2015 · Orthopedic
Device Facts
Record ID
K152169
Device Name
Balanced Knee System TriMax CR Femoral Component and E-Vitalize CR and UC Tibial Inserts
Applicant
Ortho Development Corporation
Product Code
JWH · Orthopedic
Decision Date
Oct 27, 2015
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 888.3560
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The Balanced Knee® System TriMax™ CR Femoral Component and E-Vitalize® CR and UC Tibial Inserts are intended for single use cemented total knee arthroplasty procedures with the following indications: 1. Loss of knee joint configuration and joint function. 2. Osteoarthritis of the knee joint. 3. Rheumatoid arthritis of the knee joint. 4. Post-traumatic arthritis of the knee joint. 5. Valgus, varus, or flexion deformities of the knee joint. 6. Revision procedures where other treatments or devices have failed.
Device Story
Balanced Knee® System TriMax™ CR Femoral Component and E-Vitalize® CR/UC Tibial Inserts are orthopedic implants for total knee arthroplasty. The femoral component is a polished Co-Cr-Mo cruciate-retaining implant designed for up to 150° flexion. Tibial inserts are machined from Vitamin E-stabilized, crosslinked UHMWPE. The system is intended for single-use, cemented fixation. Surgeons implant these components to restore knee joint configuration and function in patients with degenerative or post-traumatic joint disease. The device provides a mechanical bearing surface to replace damaged cartilage and bone, facilitating improved range of motion and joint stability. It is used in clinical settings by orthopedic surgeons.
Clinical Evidence
Bench testing only. Evaluations included range of motion, femorotibial and patellofemoral constraint and contact area, femoral component fatigue strength, insert assembly/disassembly, and knee wear testing.
Technological Characteristics
Femoral component: Co-Cr-Mo (ASTM F75-12). Tibial inserts: Extensively crosslinked Vitamin E UHMWPE (ASTM F2695-12). Design: Cruciate-retaining (CR) and ultracongruent (UC) bearing surfaces. Fixation: Cemented femoral component; locking mechanism for tibial insert to tray. Range of motion: Up to 150° flexion.
Indications for Use
Indicated for patients requiring cemented total knee arthroplasty due to loss of joint function, osteoarthritis, rheumatoid arthritis, post-traumatic arthritis, valgus/varus/flexion deformities, or failed previous treatments.
Regulatory Classification
Identification
A knee joint patellofemorotibial polymer/metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a knee joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. This generic type of device includes prostheses that have a femoral component made of alloys, such as cobalt-chromium-molybdenum, and a tibial component or components and a retropatellar resurfacing component made of ultra-high molecular weight polyethylene. This generic type of device is limited to those prostheses intended for use with bone cement (§ 888.3027).
Balanced Knee® System High Flex Vitamin E PS Tibial Insert and Patella (K131337)
Submission Summary (Full Text)
{0}------------------------------------------------
Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo is a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is an image of three stylized human profiles facing to the right, stacked on top of each other. The profiles are black and the background is white.
Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002
October 27, 2015
Ortho Development Corporation Mr. Drew Weaver Director of Regulatory Affairs and Ouality Assurance 12187 South Business Park Drive Draper, Utah 84020
Re: K152169
Trade/Device Name: Balanced Knee® System Trimax™ CR Femoral Component and E-Vitalize® CR and UC Tibial Inserts Regulation Number: 21 CFR 888.3560 Regulation Name: Knee joint patellofemorotibial polymer semi-constrained cemented prosthesis Regulatory Class: Class II Product Code: JWH, OIY Dated: July 31, 2015 Received: August 4, 2015
Dear Mr. Weaver:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug. and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration. Iisting of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Parts 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set
{1}------------------------------------------------
forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.
Sincerely yours,
# Mark N. Melkerson -S
Mark N. Melkerson Director Division of Orthopedic Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
## Indications for Use
510(k) Number (if known) K152169
Device Name
Balanced Knee® System TriMax™ CR Femoral Component and E-Vitalize® CR and UC Tibial Inserts
Indications for Use (Describe)
The Balanced Knee® System TriMax™ CR Femoral Component and E-Vitalize® CR and UC Tibial Inserts are intended for single use cemented total knee arthroplasty procedures with the following indications:
- 1. Loss of knee joint configuration and joint function.
- 2. Osteoarthritis of the knee joint.
- 3. Rheumatoid arthritis of the knee joint.
- 4. Post-traumatic arthritis of the knee joint.
- 5. Valgus, varus, or flexion deformities of the knee joint.
- 6. Revision procedures where other treatments or devices have failed.
| Type of Use (Select one or both, as applicable) |
|-------------------------------------------------|
|-------------------------------------------------|
| <label><input type="checkbox"/> Residential Use (Dwelling, STR, MH, Cabin, etc.)</label> | <label><input type="checkbox"/> Other: Commercial/Health STR, MH, Cabin, etc.</label> |
|------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------|
|------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------|
|× | Prescription Use (Part 21 CFR 801 Subpart D)
| | Over-The-Counter Use (21 CFR 801 Subpart C)
#### CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
{3}------------------------------------------------
12187 So. Business Park Drive Draper, Utah 84020 801-553-9991/fax 553-9993
orthodevelopment.com
Image /page/3/Picture/2 description: The image shows the logo for "Ortho Development". The logo consists of a purple circle with three gray arcs above it, followed by the word "ORTHO" in purple, and the word "DEVELOPMENT" in gray below the word "ORTHO". The logo is simple and modern.
# Section 5
# 510(k) Summary
| NAME OF<br>SPONSOR: | Ortho Development Corporation<br>12187 South Business Park Drive<br>Draper, Utah 84020 |
|---------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| 510(k) CONTACT: | Drew Weaver<br>Director of Quality Assurance and Regulatory Affairs<br>Telephone: (801) 553-9991<br>Facsimile: (801) 553-9993<br>Email: DWeaver@orthodevelopment.com |
| DATE PREPARED: | July 31, 2015 |
| PROPRIETARY<br>NAME: | Balanced Knee® System TriMax™ CR Femoral Component<br>and E-Vitalize® CR and UC Tibial Inserts |
| COMMON NAME: | Total Knee Replacement Prosthesis |
| CLASSIFICATION: | Class II Device |
| PRODUCT<br>CODES/<br>REGULATION<br>DESCRIPTION<br>AND NUMBER: | JWH - Knee joint patellofemorotibial polymer/metal/polymer semi-constrained<br>cemented prosthesis (21 CFR 888.3560)<br>OIY - Knee joint patellofemorotibial polymer/metal/polymer semi-constrained<br>cemented prosthesis (21 CFR 888.3560) |
| PREDICATE<br>DEVICES: | Balanced Knee® System (K994370),<br>Ortho Development Corporation<br>Balanced Knee® System Ultracongruent Tibial Insert (K090705),<br>Ortho Development Corporation<br>Balanced Knee® System High Flex PS (K123457),<br>Ortho Development Corporation<br>Balanced Knee® System High Flex Vitamin E PS Tibial Insert and Patella (K131337)<br>Ortho Development Corporation |
{4}------------------------------------------------
### Device Description
The Balanced Knee® System TriMax™ CR femoral component is a highly polished Co-Cr-Mo cruciate retaining femoral component that is designed to accommodate increased range of motion up to 150° of flexion. E-Vitalize® CR and UC tibial inserts are machined from extensively crosslinked, compression molded, Vitamin E UHMWPE (same material as K131337). All components are single use only and the TriMax™ CR femoral component is intended for cemented use only.
The E-Vitalize® CR and UC tibial inserts may be used with TriMax™ CR or BKS CR femoral components. E-Vitalize® CR and UC tibial inserts may also be used with all Ortho Development's tibial tray component offerings. The TriMax™ CR femoral component may be used with all Ortho Development patella component offerings.
#### Intended Use
The Balanced Knee® System TriMax™ CR Femoral Component and E-Vitalize® CR and UC Tibial Inserts are intended for single use cemented total knee arthroplasty procedures with the following indications:
- 1. Loss of knee joint configuration and joint function.
- 2. Osteoarthritis of the knee joint.
- 3. Rheumatoid arthritis of the knee joint.
- 4. Post-traumatic arthritis of the knee joint.
- 5. Valgus, varus, or flexion deformities of the knee joint.
- 6. Revision procedures where other treatments or devices have failed.
#### Technological Characteristics
The predicate devices and TriMax™ CR femoral component and E-Vitalize® CR and UC tibial inserts are based on the following same technological elements:
TriMax™ CR Femoral Component
- Cruciate retaining femoral component design
- Increased range of motion up to 150° flexion
- Cemented fixation of femoral component onto prepared distal femur 0
- Available in a range of sizes to accommodate patient anatomy
- Material: Co-Cr-Mo ASTM F75-12
#### E-Vitalize® CR Tibial Insert
- Cruciate retaining bearing surface design
- Available in a range of sizes and thicknesses to accommodate patient anatomy
- Use of a locking mechanism to secure tibial insert to tibial tray ●
- Material: Extensively Crosslinked Vitamin E Polyethylene UHMWPE (α-tocopherol) ASTM F2695-12
{5}------------------------------------------------
#### E-Vitalize® UC Tibial Insert
- Ultracongruent bearing surface design
- Available in a range of sizes and thicknesses to accommodate patient anatomy
- Use of a locking mechanism to secure tibial insert to tibial tray
- Material: Extensively Crosslinked Vitamin E Polyethylene UHMWPE (α-tocopherol) ASTM F2695-12 (same material as K131337)
### Performance Data
The following non-clinical evaluations were performed and demonstrated substantial equivalence to the predicate devices: Range of Motion, Femorotibial Constraint, Femorotibial Contact Area, Patellofemoral Constraint, Patellofemoral Contact Area, Femoral Component Fatigue Strength, Insert Assembly/Disassembly, and Knee Wear.
### Basis for Substantial Equivalence
The TriMax™ CR femoral component and E-Vitalize® CR and UC tibial inserts are substantially equivalent to the previously cleared predicate devices based on similarities in intended use, design, materials, manufacturing methods, packaging, and mechanical performance.
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.