K151764 · Yamahachi Dental Products USA, Inc. · EBG · Nov 23, 2015 · Dental
Device Facts
Record ID
K151764
Device Name
YAMAHACHI PMMA DISKS
Applicant
Yamahachi Dental Products USA, Inc.
Product Code
EBG · Dental
Decision Date
Nov 23, 2015
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 872.3770
Device Class
Class 2
Indications for Use
YAMAHACHI PMMA DISKS are polymethyl methacrylate blanks used to mill dental long-term temporary crowns and bridges in various CAD/CAM systems until permanent restorations can be delivered.
Device Story
Yamahachi PMMA Disks are hot-cured polymethyl methacrylate (PMMA) acrylic blanks; used by dental technicians in CAD/CAM milling systems to fabricate temporary crowns and bridges. Process: intraoral scan of patient tooth; proprietary software creates virtual restoration; milling machine carves restoration from PMMA disk. Finished prosthesis polished, adjusted in patient mouth, and cemented/bonded. Device remains in place until permanent restoration available. Available in various shapes/shades for open and closed milling systems (Amann Girrbach, Zirkonzahn, block, pin, 2-pin). Benefits: provides durable, aesthetic temporary restoration during interim period.
Clinical Evidence
Bench testing only. Device performance evaluated against ISO 10477:2004 standards for physical properties. Results demonstrate compliance with acceptance criteria and equivalence to predicate device.
Technological Characteristics
Material: Hot-cured cross-linked polymethyl methacrylate (PMMA) with pigments. Form factor: Disks, blocks, pins. Compatibility: Open and closed CAD/CAM milling systems. Standard: ISO 10477:2004 (Type 2, Class 1).
Indications for Use
Indicated for patients requiring long-term temporary crowns and bridges until permanent restorations can be delivered.
Regulatory Classification
Identification
A temporary crown and bridge resin is a device composed of a material, such as polymethylmethacrylate, intended to make a temporary prosthesis, such as a crown or bridge, for use until a permanent restoration is fabricated.
{0}------------------------------------------------
Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular emblem with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter. Inside the circle is a stylized image of three human profiles facing to the right, layered on top of each other, creating a sense of depth and unity.
Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002
November 23, 2015
Yamahachi Dental Products USA, Inc. c/o Mr. Claude Berthoin Denterprise International, Inc. 100 East Granada Blvd., Suite 219 Ormand Beach, FL 32176
Re: K151764
Trade/Device Name: Yamahachi PMMA Disks Regulation Number: 21 CFR 872.3770 Regulation Name: Temporary Crown and Bridge Resin Regulatory Class: II Product Code: EBG Dated: October 14, 2015 Received: October 16, 2015
Dear Mr. Berthoin:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{1}------------------------------------------------
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm. Also, please note the regulation entitled. "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.
Sincerely yours,
Tina Kiang -
for Erin I. Keith, M.S. Director Division of Anesthesiology, General Hospital, Respiratory, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
#### DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration
## Indications for Use
Form Approved: OMB No. 0910-0120 Expiration Date: December 31, 2013 See PRA Statement on last page.
510(k) Number (if known) K151764
Device Name Yamahachi PMMA DISKS
Indications for Use (Describe)
Y AMAHACHI PMMA DISKS are polymethyl methacrylate blanks used to mill dental long-term temporary crowns and bridges in various CAD/CAM systems until permanent restorations can be delivered.
Type of Use (Select one or both, as applicable)
x Prescription Use (Part 21 CFR 801 Subpart D)
] Over-The-Counter Use (21 CFR 807 Subpart C)
#### PLEASE DO NOT WRITE BELOW THIS LINE – CONTINUE ON A SEPARATE PAGE IF NEEDED.
#### FOR FDA USE ONLY
Concurrence of Center for Devices and Radiological Health (CDRH) (Signature)
{3}------------------------------------------------
This section applies only to requirements of the Paperwork Reduction Act of 1995.
#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
{4}------------------------------------------------
# 510(k) Summary
#### Submitter/Applicant
Yamahachi Dental Products USA, Inc. 160 Park Avenue Nutley, NJ 07110
Phone: 973-320-2909 Fax: 973-320-2995 Contact: Lawrence G. Greenwald (Yamahachi1 @yahoo.com) Date Prepared: June 23, 2015
#### Preparer/Consultant
Denterprise International, Inc. 100 East Granada Blvd., Suite 219 Ormond Beach, FL 32176
Phone: 386-672-0450 eFax: 855-235-7902 Contact Person: Joyce St. Germain, Regulatory Executive
#### Device Classification
| Trade Name: | Yamahachi PMMA Disks |
|----------------------|----------------------------------|
| Common Name: | PMMA Disks |
| Classification Name: | Temporary Crown and Bridge Resin |
| Regulation Number: | 21 CFR 872.3770 Class II |
| Product Code: | EBG |
### Predicate Device
The subject device claims equivalence to the following legally marketed predicate:
| 510(k) Number: | K093708 |
|--------------------|-------------------------------------------|
| Trade Name: | Telio CAD |
| Manufacturer: | Ivoclar Vivadent, Inc. (Amherst, NY, USA) |
| Regulation Number: | 21 CFR 872.3770 |
| Product Code: | EBG |
#### Indictions for Use
YAMAHACHI PMMA DISKS are polymethyl methacrylate blanks used to mill dental longterm temporary crowns and bridges in various CAD/CAM systems until permanent restorations can be delivered.
{5}------------------------------------------------
## Device Description
Yamahachi PMMA Disks are acrylic blanks used in dental CAD/CAM milling systems by professional dental technicians to fabricate temporary crowns and bridges. After polishing, the prosthesis is adjusted in the patient's mouth and cemented or bonded in place, where it remains until removal when the permanent restoration is available.
The restoration process begins in the dental office with an intraoral scan of the affected tooth and the surrounding teeth. Proprietary software takes this digital image and creates a replacement part for the missing areas of the tooth, creating a virtual restoration. The software sends this virtual data to a milling machine where the replacement part is carved out of a Yamahachi PMMA Disk. The optical impression system, software, and milling machine are not part of the device.
The device is composed of hot-cured polymethyl methacrylate (PMMA) and pigments.
Yamahachi PMMA Disks are available in different shapes and shades, with disks of all shades available in different dimensions (diameter, thickness and profile margin). It is intended for use in both open and closed CAD/CAM systems. The circular disk model fits open milling systems, while the configurations for closed systems include Amann Girrbach, Zirkonzahn, block, pin and 2-pin.
### Comparison of Technological Characteristics with Predicate
The following table compares technological and other characteristics of the subject and predicate device.
| | Subject Device | Predicate Device | Comparison |
|----------------------------------|---------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------|------------|
| Device | PMMA Disk | Telio CAD | NA |
| 510(k) Owner | Yamahachi Dental<br>Products (USA) | Ivoclar Vivadent<br>(Germany) | NA |
| Classification &<br>Product Code | 872.3770; EBG | 872.3770; EBG | Same |
| Device Description | Temporary Crown And<br>Bridge Resin | Temporary Crown And<br>Bridge Resin | Same |
| Common Name | PMMA Disk | PMMA Disk | Same |
| Intended Use | Milling blanks for<br>fabrication of long-<br>term temporary<br>crowns & bridges in<br>CAD/CAM systems. | Milling blanks for<br>fabrication of long-<br>term temporary<br>crowns & bridges in<br>CAD/CAM systems. | Same |
## Table 5 -- Technological Comparison
{6}------------------------------------------------
| Indication For Use | YAMAHACHI PMMA<br>DISKS are polymethyl<br>methacrylate blanks<br>used to mill dental long-<br>term temporary crowns<br>and bridges in various<br>CAD/CAM systems<br>until permanent<br>restorations can be<br>delivered. | For the fabrication of<br>temporary crowns and<br>bridges using<br>CAD/CAM technology<br>until permanent<br>restoration can be<br>delivered. | Same |
|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------|------|
|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------|------|
## Technological
| Characteristics | | | |
|---------------------|----------------------------------------------------------------------------------|----------------------------------------------------------------------------------|---------------------------------------------------------------------------------------|
| Product State | Solid | Solid | Same |
| How Device Is Made | Powder + Liquid<br>methacrylate-based<br>resins mixed together<br>and heat cured | Powder + Liquid<br>methacrylate-based<br>resins mixed together<br>and heat cured | Same |
| General Description | Cross-linked PMMA-<br>based resins with<br>pigments for tinting | Cross-linked PMMA-<br>based resins with<br>pigments for tinting | Same |
| Configurations | Open--Disc; Closed--<br>Amann Girrbach,<br>Zirkonzahn, Block, Pin<br>& 2 Pin | Closed--Block, Disc | Subject used in open as<br>well as closed systems;<br>not a meaningful<br>difference. |
| Components | PMMA with cross-<br>linker and pigments | PMMA with cross-<br>linker and pigments | Same |
### Non-clinical Performance testing
| Physical Properties | ISO 10477:2004<br>Met acceptance<br>criteria of this<br>standard. | ISO 10477:2004 | Same |
|-------------------------------|----------------------------------------------------------------------|----------------------------------------------------------------------|-----------------------------------------|
| Classification<br>(ISO 10477) | Type 2, Class 1 (Heat<br>Cure Without Photo-<br>Sensitive Initiator) | Type 2, Class 1 (Heat<br>Cure Without Photo-<br>Sensitive Initiator) | Same |
| Shelf Life | 10 Years | Not determined | Subject exceeds<br>practical shelf life |
The above comparison shows the subject and predicate devices have substantially similar technology characteristics.
{7}------------------------------------------------
#### Conclusion
The nonclinical tests demonstrate that the device is substantially equivalent to predicate device since they have the same intended use, material composition, and performed as well in physical properties testing; therefore, Yamahachi PMMA Disks warrants a finding of substantial equivalence to the legally marketed predicate device.
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.