GAMMA PHAGE LYSIS ASSAY FOR THE IDENTIFICATION OF BACILLUS ANTHRAC
K143592 · The Surgeon General, Department of the Army · NVQ · Apr 16, 2015 · Microbiology
Device Facts
Record ID
K143592
Device Name
GAMMA PHAGE LYSIS ASSAY FOR THE IDENTIFICATION OF BACILLUS ANTHRAC
Applicant
The Surgeon General, Department of the Army
Product Code
NVQ · Microbiology
Decision Date
Apr 16, 2015
Decision
SESE
Submission Type
Special
Regulation
21 CFR 866.3045
Device Class
Class 2
Indications for Use
The Gamma Phage assay is a lytic phage assay specific for Bacillus anthracis. The Gamma Phage assay (common name) can be used on suspect non-hemolytic, aerobic, gram-positive, "ground-glass"- appearing colonies from sheep blood agar in conjunction with other markers and testing for the identification of Bacillus anthracis. The assay is not intended for screening of blood or plasma donors. Use of this assay is limited to designated laboratory Response Network (LRN) and Department of Defense (D0D).
Device Story
Lytic bacteriophage assay for identification of Bacillus anthracis; utilizes gamma phage that binds to specific cell-surface components of susceptible bacteria; phage DNA injection leads to replication and production of PlyG lysine; results in cell lysis and release of progeny phage; performed in LRN and DoD laboratories by trained personnel; input is suspect bacterial colonies from sheep blood agar; output is visual observation of lysis; used in conjunction with other markers (e.g., capsule demonstration) to confirm B. anthracis identification; aids clinical/public health decision-making regarding potential anthrax exposure.
Clinical Evidence
No clinical data provided. Bench testing only.
Technological Characteristics
Lytic bacteriophage suspension; positive control (B. anthracis Sterne strain); negative control (B. cereus). Requires 5% sheep blood agar, inoculating loops, and incubator (35+/- 2 °C). Biological safety cabinet required for handling. No software or electronic components.
Indications for Use
Indicated for the identification of Bacillus anthracis in suspect non-hemolytic, aerobic, gram-positive, "ground-glass"-appearing colonies from sheep blood agar. Restricted to designated Laboratory Response Network (LRN) and Department of Defense (DoD) laboratories. Not for blood or plasma donor screening.
Regulatory Classification
Identification
An in vitro diagnostic device for Bacillus species (spp.) detection is a prescription device used to detect and differentiate among Bacillus spp. and presumptively identify B. anthracis and other Bacillus spp. from cultured isolates or clinical specimens as an aid in the diagnosis of anthrax and other diseases caused by Bacillus spp. This device may consist of Bacillus spp. antisera conjugated with a fluorescent dye (immunofluorescent reagents) used to presumptively identify bacillus-like organisms in clinical specimens; bacteriophage used for differentiating B. anthracis from other Bacillus spp. based on susceptibility to lysis by the phage; or antigens used to identify antibodies to B. anthracis (anti-toxin and anti-capsular) in serum. Bacillus infections include anthrax (cutaneous, inhalational, or gastrointestinal) caused by B. anthracis, and gastrointestinal disease and non-gastrointestinal infections caused by B. cereus.
Special Controls
*Classification.* Class II (special controls). The special controls are set forth in FDA's special controls guideline document entitled “In Vitro Diagnostic Devices for*Bacillus* spp. Detection; Class II Special Controls Guideline for Industry and Food and Drug Administration Staff.” For availability of the guideline document, see § 866.1(e).(c)
*Restriction on Distribution.* The distribution of these devices is limited to laboratories that follow public health guidelines that address appropriate biosafety conditions, interpretation of test results, and coordination of findings with public health authorities.(d)
*Restriction on Use.* The use of this device is restricted to prescription use and must comply with the following:(1) The device must be in the possession of:
(i)(A) A person, or his agents or employees, regularly and lawfully engaged in the manufacture, transportation, storage, or wholesale or retail distribution of such device; or
(B) A practitioner, such as a physician, licensed by law to use or order the use of such device; and
(ii) The device must be sold only to or on the prescription or other order of such practitioner for use in the course of his professional practice.
(2) The label of the device shall bear the statement “Caution: Federal law restricts this device to sale by or on the order of a ____”, the blank to be filled with the word “physician” or with the descriptive designation of any other practitioner licensed by the law of the State in which he practices to use or order the use of the device.
(3) Any labeling, as defined in section 201(m) of the Federal Food, Drug, and Cosmetic Act, whether or not it is on or within a package from which the device is to be dispensed, distributed by, or on behalf of the manufacturer, packer, or distributor of the device, that furnishes or purports to furnish information for use of the device contains adequate information for such use, including indications, effects, routes, methods, and frequency and duration of administration and any relevant hazards, contraindications, side effects, and precautions, under which practitioners licensed by law to employ the device can use the device safely and for the purposes for which it is intended, including all purposes for which it is advertised or represented. This information will not be required on so-called reminder-piece labeling which calls attention to the name of the device but does not include indications or other use information.
(4) All labeling, except labels and cartons, bearing information for use of the device also bears the date of the issuance or the date of the latest revision of such labeling.
Predicate Devices
Gamma Phage Lysis for the Identification of Bacillus anthracis (K051794)
Submission Summary (Full Text)
{0}
SPECIAL 510(k): Device Modification Decision Summary
To: THE FILE
RE: DOCUMENT NUMBER K143592
This 510(k) submission contains information/data on modifications made to the SUBMITTER'S own Class II, Class III or Class I devices requiring 510(k). The following items are present and acceptable:
1. The name and 510(k) number of the SUBMITTER'S previously cleared device.
GAMMA PHAGE LYSIS ASSAY FOR THE IDENTIFICATION OF BACILLUS ANTHRACIS 510(k) Number: K051794
2. Submitter's statement that the INDICATION/INTENDED USE of the modified device as described in its labeling HAS NOT CHANGED along with the proposed labeling which includes instructions for use, package labeling, and, if available, advertisements or promotional materials (labeling changes are permitted as long as they do not affect the intended use).
3. A description of the device MODIFICATION(S):
The modification presented in this special 510(k) consisted of changing the Bacillus anthracis positive control from the specified Pasteur strain, to the Sterne strain. The reason for the change was to allow laboratories to maintain a non-listed agent (Sterne strain), versus the Pasteur strain that is a biological select agent, and reduce logistics burdens imposed by the use of a select agent strain without compromising the assay performance. In addition, supporting data in the form of potency testing was provided demonstrating that while the Bacillus anthracis Sterne strain is less sensitive to gamma phage lysis than the Pasteur strain, it is more representative of the gamma phage reaction when compared with wild-type Bacillus anthracis (e.g., Ames strain) and is therefore a more appropriate positive control.
In addition to changing the Bacillus anthracis positive control strain from Pasteur to Sterne, the instructions for use has been updated to include some additional sources and forms (viable lyophilized cells and/or spore suspension) of both the positive (Bacillus anthracis) and negative control (Bacillus cereus) materials. As with the original 510k submission, the control materials are listed as "available controls". Prior to use these materials are used to prepare fresh cultures of both the positive or negative controls that are then used as quality control materials for the gamma phage lysis assay. Testing and validation information was provided for the control materials BC3366, BC3133 and BC3367 and Certificate of Analysis (COAs) were provided for the control materials ATCC14579 (from ATCC) and 19102 (from Colorado Serum Company).
The FUNDAMENTAL SCIENTIFIC TECHNOLOGY of the modified device has not changed.
4. Comparison Information:
Similarities to applicant's legally marketed predicate device include:
The procedure for running the Gamma Phage Lysis Assay for testing isolated colonies of gram positive bacilli with colony morphology typical of Bacillus anthracis outlined in the Gamma Phage Lysis Assay for the Identification of Bacillus anthracis Instructions for Use remains unchanged. In addition the procedure for running the positive and negative controls as part of the Quality Control testing remains unchanged and involves preparation of fresh cultures of the control strains by inoculation of a Sheep Blood Agar (SBA) plate – streak for isolation and incubate overnight.
{1}
Page 2 of 3
Table 1: Similarities between the predicate device (K051794) and the proposed device (K143592)
| Feature | K051794
Predicate Device | K143592
Proposed Device |
| --- | --- | --- |
| Bacillus anthracis
Gamma Phage
Suspension | Bacillus anthracis Gamma Phage Suspension 0.5 ml (BP3123) | Same |
| Specimen | Gamma Phage Assay should be performed on isolated colonies of gram positive bacilli with colony morphology typical of B. anthracis | Same |
| Materials required but not supplied | • 5% Sheep Blood Agar plate
• Inoculating loops, 1μl and 10 μl
• Aerosol resistant pipette tips
• Disinfectant | Same |
| Equipment required | • Pipettor, 5-50 μl
• Incubator, 35+/- 2 °C
• Biological Safety Cabinet, Class II
• Refrigerator, 2-8 °C | Same |
Differences to applicant's legally marketed predicate device include:
The Gamma Phage Lysis Assay for the Identification of Bacillus anthracis Instructions for Use has been updated to include Bacillus anthracis Sterne strain as the positive control. In addition the "materials" section has been updated to include some additional sources and forms (viable lyophilized cells and/or spore suspension) of both the positive and negative control materials (see Table 2).
Table 2: Differences between the predicate device (K051794) and the proposed device (K143592)
| Feature | K051794
Predicate Device | K143592
Proposed Device |
| --- | --- | --- |
| Positive Control | Bacillus anthracis Pasteur strain spore suspension 1.0 ml (BC3132) | Bacillus anthracis Sterne strain viable lyophilized cells (BC3366)
Colorado Serum Company (19102) Anthrax Spore Vaccine – 1.0 ml suspension of viable Bacillus anthracis Sterne strain 34F2 spores |
| Negative Control | Bacillus cereus spore suspension 1.0 ml (BC3133) | Bacillus cereus spore suspension 1.0 ml (BC3133) - same
Bacillus cereus lyophilized cells (BC3367)
ATCC 14579 – Bacillus cereus freeze-dried (lyophilized) |
| Reporting – Capsule Staining Techniques | A positive gamma phage result, in conjunction with a positive result for capsule, is considered confirmatory identification of B. anthracis. Capsule may be demonstrated by colony morphology on bicarbonate agar after incubation in enhanced CO2 or by staining techniques (India ink, M'Fadyean, or capsule DFA). | A positive gamma phage result, in conjunction with a positive result for capsule, is considered confirmatory identification of B. anthracis. Capsule may be demonstrated by colony morphology on bicarbonate agar after incubation in enhanced CO2 or by staining techniques (India ink or M'Fadyean).
Difference - Capsule DFA removed. |
Contact information for the additional sources (Colorado Serum Company and ATTC) was provided with the following disclaimer "Names of vendors or manufacturers are provided as examples of suitable product sources. Inclusion does not imply endorsement by the Centers for Disease Control and Prevention, the Department of Health and Human Services or the Federal Bureau of Investigation". The "interpretation of results" section has also been updated with a description and
{2}
Page 3 of 3
images of what to expect when using the *Bacillus anthracis* Sterne strain as the positive control. However, it does not change the interpretation of the quality controls or the wild type strains. The "reporting" section has been updated to (1) remove capsule DFA as it is no longer used as a staining technique for this assay and (2) to include the requirement that all test results (positive, negative, inconclusive) should be submitted to CDC as outlined in the Data Messaging Policy on the secure LRN website. The Gamma Phage Lysis Assay for the Identification of *Bacillus anthracis* Instructions for Use has also been updated to include a "procedure notes" section and "credit" section – which outlines the agencies involved in the development of the assay.
The package inserts for the positive and negative control materials distributed by CDC for the LRN - BC3366, BC3367 have been updated/ included to reflect the modifications outlined in the table above. Minor modifications to update contact emails were also included.
5. Design Control Activities Summary:
A "Declaration of Conformity with Design Controls" statement was submitted for the manufacturing facility and verification activities. The statements indicate that:
1. The manufacturing facility is in conformance with design control procedure requirements as specified in 21 CFR 820.30 and the records are available for review – signed by the Chief of the Scientific Products and Support Branch.
2. The validation activities, as required by the risk analysis, for the modification were performed by the designated individuals and the results demonstrated that the predetermined acceptance criteria were met - signed by a supervisory research microbiologist.
6. Truthful and Accuracy Statement, a 510(k) Summary or Statement, Package Inserts, Labels Instructions for Use and the Indications for Use Enclosure:
The labeling for this modified subject device has been reviewed to verify that the indication/intended use for the device is unaffected by the modification. In addition, the submitter's description of the particular modification(s) and the comparative information between the modified and unmodified devices demonstrate that the fundamental scientific technology has not changed. The submitter has provided the design control information as specified in The New 510(k) Paradigm and on this basis, I recommend the device be determined substantially equivalent to the previously cleared (or their preamendment) device.
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.