CGBA-032A, Aquilion PRIME Self-Propelled Scan Base Kit for IVR-CT
K143223 · Toshibamedical Systems Corporation · JAK · Jan 12, 2015 · Radiology
Device Facts
Record ID
K143223
Device Name
CGBA-032A, Aquilion PRIME Self-Propelled Scan Base Kit for IVR-CT
Applicant
Toshibamedical Systems Corporation
Product Code
JAK · Radiology
Decision Date
Jan 12, 2015
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 892.1750
Device Class
Class 2
Indications for Use
Optional movable gantry base unit for use with an Aquilion PRIME system to support longitudinal movement and allow acquisition of images in the z-direction (z-axis). Note: When installed with the movable gantry base unit, Aquilion PRIME can be used with the INFX-8000C system in the same room.
Device Story
The CGBA-032A is an optional movable gantry base kit for the Aquilion PRIME CT system, designed for integration with the Toshiba INFX-8000C interventional X-ray system. It replaces the standard CT patient couch with the interventional system's fixed catheterization table. The device enables longitudinal gantry movement along floor-mounted rails, allowing the CT system to acquire images in the z-direction (axial and helical) while the patient remains on the interventional table. Used in clinical interventional suites, it is operated by physicians and technicians. System interlocks are incorporated to prevent interference between the CT and interventional systems when both are in the same room. The device facilitates efficient workflow for interventional procedures by allowing patient access and imaging without transferring the patient between tables.
Clinical Evidence
Bench testing only. Verification and validation testing confirmed that base movement speed, scanogram acquisition, axial/helical scan functions, and safety interlocks (including contact detection) performed according to specifications. No clinical data was required or provided.
Technological Characteristics
Movable gantry base unit for longitudinal movement along floor rails. Integrates with Aquilion PRIME CT and INFX-8000C interventional systems. Conforms to IEC 60601-1, 60601-1-2, 60601-2-44, and NEMA XR-25/26 standards. Includes system interlocks for collision avoidance. Software is classified as Moderate Level of Concern.
Indications for Use
Indicated for use as an optional movable gantry base unit for the Aquilion PRIME CT system to support longitudinal movement and allow z-axis image acquisition (axial and helical) when using a fixed catheterization table.
Regulatory Classification
Identification
A computed tomography x-ray system is a diagnostic x-ray system intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data from the same axial plane taken at different angles. This generic type of device may include signal analysis and display equipment, patient and equipment supports, component parts, and accessories.
Predicate Devices
Aquilion™ ONE Vision Self-Propelled Scan Base for IVR CT (K134025)
{0}------------------------------------------------
Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized caduceus symbol, which is a staff with two snakes coiled around it, and the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged in a circular pattern around the symbol. The caduceus is rendered in black and white, and the text is in a simple, sans-serif font.
Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002
January 12, 2015
Toshiba Medical Systems Corporation % Mr. Paul Biggins Director, Regulatory Affairs Toshiba America Medical Systems, Inc. 2441 Michelle Drive TUSTIN CA 92780
Re: K143223
Trade/Device Name: CGBA-032A, Aquilion™ PRIME Self-Propelled Scan Base Kit for IVR-CT Regulation Number: 21 CFR 892.1750 Regulation Name: Computed tomography x-ray system Regulatory Class: II Product Code: JAK Dated: November 12, 2014 Received: November 13, 2014
Dear Mr. Biggins:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set
{1}------------------------------------------------
forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638 2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.
Sincerely yours,
Robert A Ochs
Robert Ochs, Ph.D. Acting Director Division of Radiological Health Office of In Vitro Diagnostics and Radiological Health Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
510(k) Number (if known)
K143223
Device Name
CGBA-032A, Aquilion PRIME Self-Propelled Scan Base Kit for IVR-CT
#### Indications for Use (Describe)
Optional movable gantry base unit for use with an Aquilion PRIME system to support longitudinal movement and allow acquisition of images in the z-direction (z-axis).
Note: When installed with the movable gantry base unit, Aquilion PRIME can be used with the INFX-8000C system in the same room.
#### Type of Use (Select one or both, as applicable)
Y Prescription Use (Part 21 CFR 801 Subpart D)
Over-The-Counter Use (21 CFR 801 Subpart C)
## PLEASE DO NOT WRITE BELOW THIS LINE – CONTINUE ON A SEPARATE PAGE IF NEEDED.
#### FOR FDA USE ONLY
Concurrence of Center for Devices and Radiological Health (CDRH) (Signature)
This section applies only to requirements of the Paperwork Reduction Act of 1995.
#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
{3}------------------------------------------------
Image /page/3/Picture/0 description: The image shows the logo for Toshiba. The word "TOSHIBA" is written in large, bold, red letters. Below the company name is the slogan "Leading Innovation" in black font, followed by three right-pointing arrows.
#### TOSHIBA AMERICA MEDICAL SYS
2441 Michelle Drive, Tustin, CA 92780 Phone: (714) 730-5000
### 510(k) SUMMARY
## SUBMITTER'S NAME:
Toshiba America Medical Systems, Inc.
- 1. ADDRESS: 2441 Michelle Drive Tustin, CA 92780-2068
- 2. ESTABLISHMENT REGISTRATION: 2020563
# 3. CONTACT PERSON:
Paul Biggins Director, Regulatory Affairs (714) 730-5000
- 4. Date Prepared: November 7th, 2014
- 5. TRADE NAME(S): CGBA-032A, Aquilion™ PRIME Self-Propelled Scan Base Kit for IVR-CT
## 6. COMMON NAME: Computed Tomography X-Ray System
- 7. DEVICE CLASSIFICATION: Class II 21 CFR 892.1750 - Computed Tomography X-Ray System
- 8. PRODUCT CODE / DESCRIPTION: JAK - System, X-Ray, Tomography, Computed
-
- 9. PERFORMANCE STANDARD: This device conforms to applicable Performance Standards for Ionizing Radiation Emitting Products [21 CFR, Subchapter J, Part 1020]
## 10. PREDICATE DEVICES:
| Product | Marketed by | 510(k) Number | Clearance Date | RTA Acceptance<br>Date |
|--------------------------------------------------------------|------------------------------------|---------------|-------------------|------------------------|
| Aquilion™ ONE Vision Self-<br>Propelled Scan Base for IVR CT | Toshiba America<br>Medical Systems | K134025 | September 5, 2014 | N/A |
| Aquilion™ PRIME | Toshiba America<br>Medical Systems | K141741 | N/A | July 11, 2014 |
| Infinix™ INFX-8000C | Toshiba America<br>Medical Systems | K113052 | November 22, 2011 | N/A |
{4}------------------------------------------------
# 11. REASON FOR SUBMISSION:
Modification of a cleared device.
The purpose of this submission is to seek market clearance for CGBA-032A, Aquillion PRIME Self-Propelled Scan Base Kit for IVR-CT. This device is an optional kit intended to be used on an Aquilion PRIME / INFX-8000C based IVR-CT system. It is attached to the CT gantry to support longitudinal movement and allow image acquisition in the zdirection (Z-axis), both axial and helical. When this option is selected, the standard CT patient couch is replaced with the patient handling system utilized by the interventional x-ray system, Toshiba INFX-8000C. The Aquilion PRIME Self-Propelled Scan Base Kit for IVR-CT will be used as part of an Aquilion PRIME / INFX-8000C based IVR-CT system. Please note, the intended uses and technological characteristics of the Aquilion PRIME CT System and the INFX-8000C Interventional X-Ray System remains the same. There have been no modifications made to the imaging chains in these FDA cleared devices and the base system software remains the same. Since both systems will be installed in the same room and to prevent interference during use, system interlocks have been incorporated into the systems.
Please note: The terms "Self-Propelled Scan Base", "Moving Base" and "Movement Base" are used interchangeably throughout this submission. They all refer to the same unit.
# 12. DEVICE DESCRIPTION:
The Infinix 4DCT is composed of the INFX-8000C interventional angiography system and the dynamic volume CT system. Aquilion PRIME. This combination enables patient access and efficient workflow for interventional procedures. CGBA-032A, Aquilion PRIME Self-Propelled Scan Base Kit for IVR-CT is an optional kit intended to be used in conjunction with an Aquilion PRIME / INFX-8000C based IVR-CT system. The subject device is attached to the CT gantry to support longitudinal movement and allow image acquisition in the z-direction (Z-axis), both axial and helical. When this option is selected, the standard CT patient couch is replaced with the patient handling system utilized by the interventional x-ray system, Toshiba INFX-8000C. The intended uses and technological characteristics of the Aquilion PRIME CT System and INFX-8000C Interventional X-Ray System with which this device is used, remain the same.
## 13. INDICATIONS FOR USE:
Optional movable gantry base unit for use with an Aquilion PRIME system to support longitudinal movement and allow acquisition of images in the z-direction (Z-axis).
## 14. SUBSTANTIAL EQUIVALENCE:
This device is substantially equivalent to CGBA-033A, Aquilion ONE Movement Base Kit, which received premarket clearance under K134025, marketed by Toshiba America Medical Systems.
CGBA-032A, Aquilion PRIME Self-Propelled Scan Base Kit for IVR-CT, incorporates modifications to the cleared device in order for the self-propelled scan base unit to be connected to an Aquilion PRIME gantry. This allows the CT system to acquire images in the z-direction (Z-axis) when a fixed catheterization table is used for patient support instead of a dedicated CT patient couch. The indications for use, method of operation
{5}------------------------------------------------
including the imaging chain, base software and manufacturing process of the CT and Interventional XR systems remain unchanged from the cleared devices.
A complete comparison table is included in this submission. See below for a brief summary of changes from CGBA-033A, Aquilion ONE Vision Self-Propelled Base Kit:
| Item | CGBA-032A, Aquilion™<br>PRIME Self-Propelled Scan<br>Base Kit for IVR-CT | CGBA-033A, Aquilion™<br>ONE Vision Self-Propelled<br>Scan Base Kit for IVR-CT | Comments |
|------------------------------------------|--------------------------------------------------------------------------|-------------------------------------------------------------------------------|----------|
| CT System | Aquilion™ PRIME | Aquilion™ ONE Vision | Changed |
| Gantry drive | Movement along rails laid on<br>the floor | Movement along rails laid on<br>the floor | Same |
| Cabling | Floor cabling | Roof cabling | Same |
| Couch | Fixed catheterization table<br>(INFX-8000C System) | Fixed catheterization table<br>(INFX-8000C System) | Same |
| Scan direction | IN/OUT directions | IN/OUT direction | Same |
| Direction of<br>Scanogram<br>acquisition | IN/OUT directions | IN/OUT directions | Same |
The Aquilion PRIME (TSX-303A/A, 303A/B and 303A/F) received RTA Acceptance (K141741) as of July 11th, 2014. The changes made to the predicate device (K141741) include implementation of a new detector and optional software features which have been separately cleared under the 510(k) premarket notification process. CGBA-032A, Aquilion PRIME Self-Propelled Scan Base Kit for IVR-CT, is an optional kit intended to be used on an Aquilion PRIME / INFX-8000C based IVR-CT system.
# 15. SAFETY:
The device is designed and manufactured under the Quality System Requlations as outlined in 21 CFR § 820 and ISO 13485 Standards. This device is in conformance with the applicable parts of the IEC60601-1, IEC60601-1-1, IEC60601-1-2, IEC60601-1-3, IEC60601-1-4, IEC60601-1-6, IEC60601-1-9, IEC60601-2-28, IEC60601-2-32, IEC60601-2-44. IEC60825-1. IEC62304. IEC62366. IEC 60825. NEMA PS 3.1-3.18. NEMA XR-25 and NEMA XR-26. Additionally, this device complies with all applicable requirements of the radiation safety performance standards, as outlined in 21 CFR §1010 and §1020.
# 16. NON-CLINICAL TESTS
This submission includes summary tables detailing the risk analysis and verification/validation testing conducted through bench testing which demonstrates that the requirements for the modifications made to the system have been met. Evaluation of the modified device included, but was not limited to, confirmation that base movement speed, scanogram and axial/helical scan functions, and interlocks including contact detection, performed according to specifications.
Software Documentation for a Moderate Level of Concern, per the FDA quidance document. "Guidance for the Content of Premarket Submissions for Software Contained in Medical Devices Document" issued on May 11, 2005, is also included as part of this submission.
Additionally, testing of the modified system was conducted in accordance with the
{6}------------------------------------------------
applicable standards published by the International Electrotechnical Commission (IEC) for Medical Devices and CT Systems.
# 17. CONCLUSION
The modifications incorporated into CGBA-032A, Aquilion™ PRIME Self-Propelled Scan Base Kit for IVR-CT, do not change the indications for use or the intended use of the previously cleared devices. Based upon bench testing, successful completion of software validation, and application of risk management and design controls, it is concluded that the subject device is safe and effective for its intended use and is substantially equivalent to the predicate device.
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.