UPCERA DENTAL ZIRCONIA BLANK & DENTAL ZIRCONIA PRE-SHADED BLANK

K141724 · Liaoning Upcera Co., Ltd. · EIH · Oct 22, 2014 · Dental

Device Facts

Record IDK141724
Device NameUPCERA DENTAL ZIRCONIA BLANK & DENTAL ZIRCONIA PRE-SHADED BLANK
ApplicantLiaoning Upcera Co., Ltd.
Product CodeEIH · Dental
Decision DateOct 22, 2014
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 872.6660
Device ClassClass 2

Indications for Use

Upcera Dental Zirconia Blanks & Dental Zirconia Pre-Shaded Blanks are used for dental restorations using different CAD/CAM or manual milling machines. All blanks are processed thought dental laboratories or by dental professionals.

Device Story

Device consists of zirconia powder blanks (regular and pre-shaded) used for fabricating all-ceramic dental restorations; crowns, bridges, veneers, inlays, onlays. Blanks are milled by dental professionals or laboratories using CAD/CAM or manual milling machines. Pre-shaded blanks incorporate inorganic pigments (Fe2O3, Pr2O3, Er2O3) to match natural tooth color. After milling, restorations are sintered at temperatures > 1500 °C. Device provides a durable, biocompatible ceramic material for dental prosthetics, benefiting patients by restoring tooth function and aesthetics.

Clinical Evidence

Bench testing only. Performance verified per ISO 6872:2008 (flexural strength, density). Biocompatibility testing performed per ISO 10993 series (cytotoxicity, irritation, sensitization, subchronic toxicity, genotoxicity) confirms safety comparable to predicate.

Technological Characteristics

Materials: Yttria-stabilized zirconia (ZrO2 + Y2O3 + HfO2 + Al2O3) conforming to ISO 13356. Pre-shaded version includes <2.0% inorganic pigments (Fe2O3, Pr2O3, Er2O3). Form factors: blocks, discs, rods. Processing: CAD/CAM or manual milling followed by sintering > 1500 °C. Non-sterile. Performance conforms to ISO 6872.

Indications for Use

Indicated for dental restorations (crowns, bridges, veneers, inlays, onlays) processed by dental laboratories or professionals using CAD/CAM or manual milling machines.

Regulatory Classification

Identification

Porcelain powder for clinical use is a device consisting of a mixture of kaolin, felspar, quartz, or other substances intended for use in the production of artificial teeth in fixed or removable dentures, of jacket crowns, facings, and veneers. The device is used in prosthetic dentistry by heating the powder mixture to a high temperature in an oven to produce a hard prosthesis with a glass-like finish.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo is a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is an abstract image of an eagle or other bird-like figure, with its wings outstretched. The image is black and white. Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002 October, 22, 2014 Liaoning Upcera Company Limited C/O Mr. Charles Shen Manton Business and Technology Services 853 Dorchester LN, Unit-B New Milford, NJ 07646 Re: K141724 Trade/Device Name: Upcera Dental Zirconia Blank & Dental Zirconia Pre-Shaded Blank Regulation Number: 21 CFR 872.6660 Regulation Name: Porcelain Powder for Clinical Use Regulatory Class: II Product Code: EIH Dated: July 24, 2014 Received: July 24, 2014 Dear Mr. Shen: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug. and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. {1}------------------------------------------------ Page 2 - Mr. Shen Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Small Manufacturers, International and Consumer Assistance at its tollfree number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm. Also, please note the regulation entitled. "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Sincerely yours, Susan Runno DDS, MA Erin I. Keith, M.S. Director Division of Anesthesiology, General Hospital, Respiratory, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health {2}------------------------------------------------ Section 4: Indication for Use ## Section 4: Indications for Use 510(k) Number (if known): N/A K141724 Device Name: Upcera Dental Zirconia Blank & Dental Zirconia Pre-Shaded Blank Indications for Use: Upcera Dental Zirconia Blank & Dental Zirconia Pre-Shaded Blank are used for dental restorations using different CAD/CAM or manual milling machines. All blanks are processed thought dental laboratories or by dental professionals. Prescription Use X (Part 21 CFR 801 Subpart D) AND/OR Over-The-Counter Use (21 CFR 801 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE OF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) 、MACANNEW OF CREATH CHANNER 2007年 アイズル アイデリア アイデリア コミュニア ( PERMIC 2007) Section 4: Indication for Use Sec. 4 Page 1 of 1 {3}------------------------------------------------ # Section 5: 510(k) Summary: This summary of 510k safety and effectiveness information is being submitted In accordance with the requirements of 21CFR 807.92 #### Submitter & Foreign Manufacture Identification 5.1 Liaoning Upcera Co., Ltd No.122 Xianghuai Road, Economic Development Zone, Benxi, Liaoning, China Tel: (086)-24-45565006 Submitter's FDA Registration Number: 3010582952 www.upcera-dental.com #### 5.2 Contact Person Charles Shen Manton Business and Technology Services 853 Dorchester LN, Unit-B New Milford, NJ 08534 Tel: 608-217-9358 Email: cyshen@aol.com #### Date of Summary: June 19, 2014 5.3 5.4 Device Name: Upcera Dental Zirconia Blank & Dental Zirconia Pre-Proprietary Name: Shaded Blank Dental Zirconia Ceramics Common Name: Classification Name: Powder, Porcelain Device Classification: II 21 CFR 872.6660 Regulation Number: Dental Panel: General EIH Product Code: #### Predicate Device Information: ર્ડ - K093560, "Upcera Zirconia Blanks", manufactured by "Shenyang Upcera Co., (1) Ltd.'' #### Device Description: ર્સ્વર્સ Upcera Dental Zirconia Blanks are derived from Zirconia powder that has been processed into their final net shapes. These blanks are then being further fabricated into all-ceramic restorations such as crowns, bridges, veneers, inlay/ onlay. The zirconia powder is composed of ZrO2 + Y2O3 + HfO2 + Al2O3 with its composition conforms to ISO 13356, {4}------------------------------------------------ Section 5: 510(k) Summary Implants for Surgery -- Ceramic Materials Based on Yttria-Stabilized Tetragonal Zirconia (Y-TZP). The performance of the dental blanks conforms to ISO 6872, Dentistry: Ceramic Materials Upcera Dental Zirconia Pre-Shaded Blanks are derived from the same Zirconia powder as the regular Upcera Dental Zirconia Blanks, with the addition of very small amount of inorganic pigments, before the composite material is processed into their final net shapes. These blanks are then being further fabricated into all-ceramic restorations such as crowns, bridges, veneers, inlay/ onlay. The purpose of the inorganic pigments is to generate the color on the prosthetic dental devices, after sintering at dental labs, that matches natural color of patient's teeth. The performance of the pre-shaded dental zirconia blanks conforms to ISO 6872: 2008, Dentistry: Ceramic Materials ### 5.7 Intended Use: Upcera Dental Zirconia Blanks & Dental Zirconia Pre-Shaded Blanks are used for dental restorations using different CAD/CAM or manual milling machines. All blanks are processed thought dental laboratories or by dental professionals. ### 5.8 Summary of Device Testing: Bench testing was performed per ISO 6872:2008 and internal procedures to ensure that the Upcera Dental Zirconia Blanks & Dental Zirconia Pre-Shaded Blanks met its specifications. All tests were verified to meet acceptance criteria. Biocompatibility testing was performed to verify the equivalent safety of the materials that are used. #### ર.9 Technological Comparison with Predicate Device The following table shows similarities and differences of use, design, and material between our device and the predicate devices. | Description | Our Device | Predicate Device (K093560) | |-----------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Indication for<br>Use | Upcera Dental Zirconia Blanks & Dental<br>Zirconia Pre-Shaded Blanks are used for<br>dental restorations using different<br>CAD/CAM or manual milling machines.<br>All blanks are processed thought dental<br>laboratories or by dental professionals. | Upcera Zirconia Blanks are indicated<br>for dental restorations using different<br>CAD/CAM or manual milling<br>machines. All blanks are processed<br>thought dental laboratories or by<br>dental professionals. | | Basic Design | Blocks, disc, and rod | Blocks, disc, and rod | | Materials | Regular:<br>Zirconia (ZrO2 + Y2O3 + HfO2 + Al2O3 $\ge$<br>99.0%) | Zirconia (ZrO2 + Y2O3 + HfO2 +<br>Al2O3 $\ge$ 99.0%) | # Table 5.1: Comparison of Intended Use. Design. Material, and Processing {5}------------------------------------------------ | | Pre-Shaded:<br>Zirconia (ZrO2 + Y2O3 + HfO2 + Al2O3 ≥<br>98.0%)<br>Inorganic pigments (Fe2O3, Pr2O3, and<br>Er2O3, <2.0%) | | |------------|---------------------------------------------------------------------------------------------------------------------------|------------------------------------| | Processing | Sintering at temperature > 1500 °C | Sintering at temperature > 1500 °C | | Dimension | Various | Various | | Single Use | Yes | Yes | | Color | None, and Pre-shaded ( for pre-shaded<br>series) | None | | Sterile | Non-sterile | Non-sterile | Our device is essentially identical to the predicate device in terms of indications for use, design, material, and processing between our device and the predicate devices. The only minor difference is that the predicate device has no color, while our devices in submission have both the non-color regular series and pre-shaded series of twenty one different colors. The colors are originated from inorganic pigments of Fe2O3, Pr2O3, and Er203, that are of very small amount (< 2.0%), and does not raise any safety issues, demonstrated by biocompatibity study. ### 5.10 Comparison of Performance with Predicate Device Performance testing was performed on the subject device and results were compared with predicate device. Tests were conducted following applicable procedures outlined in the FDA recognized consensus standard of ISO 6872, and results met all relevant requirements in the test standard. Test results on radioactivity, pre-sintered density, sintered density, and flexural strength of the subject device are very similar to the predicate device. The following table shows similarities and differences of the biocompatibility between our device and the predicate devices. Tests were conducted following the recommended procedures outlined in the FDA recognized consensus standard of ISO 10993, and results met all relevant requirements in the test standards, and are comparable to the predicate device. # Table 5.2: Comparison of Biocompatibility Testing | Description | Our Devicea | Predicate Device (K093560) | |------------------------------------|---------------------------|------------------------------| | Cytotoxicity<br>(ISO 10993-5:2009) | No cytotoxicity effect | No cytotoxicity effect | | Irritation Oral Mucosa | Not a primary oral mucosa | No intracutaneous reactivity | {6}------------------------------------------------ # Section 5: 510(k) Summary | Irritation<br>(ISO 10993-10: 2010) | irritant under the conditions of<br>the study | | |-------------------------------------------------------------|-------------------------------------------------------|-------------------------------------------------------| | Sensitization (ISO<br>10993-10: 2010) | Not a sensitizer under the<br>conditions of the study | Not a sensitizer under the<br>conditions of the study | | Subacute and<br>Subchronic Toxicity<br>(ISO 10993-11: 2006) | No subacute and subchronic<br>toxic effects observed | No acute toxicity | | Genotoxicity (ISO<br>10993-3: 2003) | No genotoxic effects observed | N/A | 4: Performed on pre-shaded zirconia blanks to cover both the regular and pre-shaded zirconia blanks. Therefore, Upcera Dental Zirconia Blanks & Dental Zirconia Pre-Shaded Blanks manufactured by "Liaoning Upcera Co., Ltd." meet requirements per ISO 6872 and ISO 10993-1. It is safe and effective, and its performance meets the requirements of its predefined acceptance criteria and intended uses. The test results are also comparable to the predicate device. ### 5.11 Substantial Equivalence Conclusion It has been shown in this 510(k) submission that Upcera Dental Zirconia Blank & Dental Zirconia Pre-Shaded Blank and its predicate devices have the identical indications for use, similar composition and biocompatibility, similar manufacturing process, and similar performance. The difference between the Upcera Dental Zirconia Blanks & Dental Zirconia Pre-Shaded Blanks and their predicate device do not raise any question regarding its safety and effectiveness. Upcera Dental Zirconia Blanks & Dental Zirconia Pre-Shaded Blanks, as designed and manufactured, are as safe and effective as its predicate device, and therefore is substantially equivalent as its predicate device.
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...