COATED VICRYL PLUS ANTIMICROBIAL (POLYGLACTIN 910) SYNTHETIC ABSORBABLE SUTURE
K132580 · ETHICON, Inc. · GAM · Feb 28, 2014 · General, Plastic Surgery
Device Facts
Record ID
K132580
Device Name
COATED VICRYL PLUS ANTIMICROBIAL (POLYGLACTIN 910) SYNTHETIC ABSORBABLE SUTURE
Applicant
ETHICON, Inc.
Product Code
GAM · General, Plastic Surgery
Decision Date
Feb 28, 2014
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 878.4493
Device Class
Class 2
Attributes
Therapeutic, Real-World Evidence
Real-World Evidence
Submission
Device
Sponsor
RWD Sources
RWE Use Summary
Key Tags
K132580 · Feb 28, 2014
COATED VICRYL PLUS ANTIMICROBIAL (POLYGLACTIN 910) SYNTHETIC ABSORBABLE SUTURE
ETHICON, Inc.
Published meta-analyses of randomized clinical trials
The sponsor cites two peer-reviewed meta-analyses to support the clinical benefit of the triclosan-coated suture in reducing surgical site infection rates in clinical practice.
Meta-analysis; Surgical site infection; Triclosan-coated suture; Clinical effectiveness
Clinical Evidence
Study Design
Population
Comparator
Key Endpoints
Systematic review and meta-analysis of triclosan-coated sutures for prevention of surgical site infections (Wang et al., 2013); Meta-analysis
Patients undergoing surgery
Not applicable for this study
Surgical site infection rates
Is there an evidence based argument for embracing an antimicrobial (triclosan) - coated suture technology to reduce the risk for surgical site infections? : A meta-analysis (Edminston et al., 2013); Meta-analysis
Patients undergoing surgery
Not applicable for this study
Surgical site infection rates
Indications for Use
Coated VICRYL Plus Antibacterial Suture is indicated for use in general soft tissue approximation and/or ligation, except for ophthalmic, cardiovascular and neurological tissues.
Device Story
Coated VICRYL Plus Antibacterial Suture is a sterile, synthetic, absorbable, multifilament (braided) surgical suture; composed of 90% glycolide and 10% L-lactide copolymer; coated with Polyglactin 370 and calcium stearate; contains antibacterial agent Irgacare MP (triclosan). Used by surgeons in clinical settings for soft tissue approximation and ligation. Suture provides mechanical support during healing; triclosan coating inhibits bacterial colonization of the suture by Staphylococcus aureus, Staphylococcus epidermidis, Methicillin-resistant S. aureus, Methicillin-resistant S. epidermidis, and Escherichia coli. Device is absorbed by the body over time; essentially complete absorption between 56 and 70 days.
Clinical Evidence
No new clinical data generated for this submission. Evidence consists of literature meta-analyses of randomized clinical trials regarding the use of triclosan-coated sutures to lower surgical site infection rates, and previously established in vivo challenge studies demonstrating inhibition of bacterial colonization.
Technological Characteristics
Synthetic absorbable multifilament (braided) suture; copolymer of 90% glycolide/10% L-lactide; coated with Polyglactin 370 and calcium stearate; contains triclosan (max 472ug/m). Available in USP sizes 5-0 through 2. Sterilized by Ethylene Oxide. Meets USP Monograph requirements (except diameter).
Indications for Use
Indicated for general soft tissue approximation and/or ligation in patients requiring surgical sutures. Contraindicated for ophthalmic, cardiovascular, and neurological tissues, and in patients with known allergic reactions to Irgacare MP (triclosan).
Regulatory Classification
Identification
An absorbable poly(glycolide/l-lactide) surgical suture (PGL suture) is an absorbable sterile, flexible strand as prepared and synthesized from homopolymers of glycolide and copolymers made from 90 percent glycolide and 10 percent l-lactide, and is indicated for use in soft tissue approximation. A PGL suture meets United States Pharmacopeia (U.S.P.) requirements as described in the U.S.P. “Monograph for Absorbable Surgical Sutures;” it may be monofilament or multifilament (braided) in form; it may be uncoated or coated; and it may be undyed or dyed with an FDA-approved color additive. Also, the suture may be provided with or without a standard needle attached.
Special Controls
*Classification.* Class II (special controls). The special control for this device is FDA's “Class II Special Controls Guidance Document: Surgical Sutures; Guidance for Industry and FDA.” See § 878.1(e) for the availability of this guidance document.
Predicate Devices
Coated VICRYL Plus Antibacterial (Polyglactin 910) Synthetic Absorbable Suture (K032420)
Reference Devices
Wang, Z.X., Jiang, C.P., Cao, Y., Ding, Y.T., Systematic review and meta-analysis of triclosan-coated sutures for prevention of surgical site infections., Br. J. Surgery, 2013.
Edminston, C.E., Doud, F.C., Leaper, D. Is there an evidence based argument for embracing an antimicrobial (triclosan) - coated suture technology to reduce the risk for surgical site infections? : A meta-analysis. Surgery; 2013; 154; 89-100.
Submission Summary (Full Text)
{0}------------------------------------------------
### 510(K) SUMMARY
In accordance with 21 CFR 807.87(h) and 21 CFR 807.92, the 510(k) Summary is provided below.
| Device Common Name: | Absorbable Poly (glycolide/L-lactide) Surgical Suture | |
|----------------------------|----------------------------------------------------------------------------------------------|--|
| Device Proprietary Name: | Coated VICRYL* Plus Antibacterial (Polyglactin 910)<br>Synthetic Absorbable Suture | |
| Submitter: | Ethicon, Inc.<br>Route 22 West<br>P.O. Box 151<br>Somerville, NJ 08876 | |
| Contact: | Peter Cecchini<br>Fellow, Regulatory Affairs<br>908-218-2457<br>pcecchin@its.jnj.com | |
| Date Prepared: | February 27, 2014 | |
| Classification Regulation: | Suture, Surgical, Absorbable Poly (glycolide/L-lactide)<br>Surgical Suture; 21 CFR §878.4493 | |
| Panel: | General and Plastic Surgery Devices | |
| Product Code: | GAM | |
| Predicate Device: | Coated VICRYL* Plus Antibacterial (Polyglactin 910)<br>Synthetic Absorbable Suture (K032420) | |
#### Indications for Use:
Coated VICRYL Plus Antibacterial Suture is indicated for use in general soft tissue approximation and/or ligation, except for ophthalmic, cardiovascular and neurological tissues.
#### Device Description:
The Coated VICRYL* Plus Antibacterial (Polyglactin 910) Synthetic Absorbable Suture is a sterile, synthetic absorbable surgical suture (dyed and undyed) and is composed of a copolymer made from 90% glycolide and 10% L-lactide. It is coated with a mixture composed of equal parts of Polyglactin 370 (65%PLA/35%PGA, a copolymer of glycolide and L-lactide) and calcium stearate. A small amount of an antibacterial agent, Irgacare MP** (triclosan), has been added to the suture coating. Irgacare** MP is the tradename given by CIBA Specialty Chemicals Corp. for their high purity material that meets U.S.P. specifications for triclosan. Coated VICR YL*
{1}------------------------------------------------
Plus Antibacterial (Polyglactin 910) Synthetic Absorbable Suture is a multifilament suture and is available dyed and undyed. It meets U.S.P. requirements, except for diameter, as described in the U.S.P. Monograph for synthetic absorbable surgical suture. The dyed version of the device is available with an approved color additive (D&C Violet No.2). The product is available in U.S.P. sizes 5-0 through 2 in a variety of lengths, with or without needles, and on LIGAPAK* dispensing reels.
The subject device is identical to the predicate device (K032420) in all aspects, including design, materials, sterilization and packaging. The only difference between the proposed and the predicate devices lies in the some labeling statements.
#### Performance Data:
The technological characteristics of the proposed device are identical to the predicate device, therefore, performance data are not necessary to establish substantial equivalence.
#### Substantial Equivalence:
The purpose of this 510(k) submission is to obtain a modified indication for use and modified labeling for the Coated VICRYL Plus Antibacterial (Polyglactin 910) Synthetic Absorbable Suture. A comparison of the proposed and predicate device is provided below.
| | Proposed Device | Predicate Device |
|---------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| 510(k) Number | K132580 | K032420 |
| Product Code | GAM | GAM |
| Regulation | 21 CFR § 878.4493 | 21 CFR § 878.4493 |
| Absorbable | Yes | Yes |
| Characteristics | Same | Coated VICRYL* Plus Antibacterial (Polyglactin<br>910) Synthetic Absorbable Suture |
| Intended use | Same | Indicated for use in general soft tissue<br>approximation and/or ligation, except for<br>ophthalmic, cardiovascular, and neurological<br>tissues. Should not be used where extended<br>approximation of tissue under stress is<br>required. Should not be used in patients with<br>known allergic reactions to Irgacare MP**. |
| How supplied | Same | Sterile, Multifilament strand (braided)<br>Available in a variety of lengths, with or without<br>needles, and on LIGAPAK* dispensing reels.<br>The devices are available in one, two or<br>three dozen boxes. |
| Color | Same | Undyed or Dyed Suture Strands |
| | Proposed Device | Predicate Device |
| Material | Same | Composed of a copolymer made from 90% |
| Composition | | glycolide and 10% L-lactide. Coated with a mixture |
| | | composed of equal parts of a copolymer of glycolide |
| | | and lactide (Polyglactin 370) and Calcium Stearate. |
| Breaking Strength | Same | Approximate percent breaking strength remaining |
| Retention profile | | (%BSR) 14 Days -75% 21 Days sizes -50% 28 Days<br>sizes -25% |
| Absorption profile | Same | Absorption is essentially complete between 56 and<br>70 days. |
| USP requirements | Same | Meets USP Monograph -except for diameter |
| Sterilization | Same | Sterilized by Ethylene Oxide |
| Packaging | Same | Foil packaging |
| Antibacterial agent | Same | The suture contains Irgacare MP |
| | | ** (triclosan), a broad-spectrum |
| | | antibacterial agent, at no more |
| :: | | than 472ug/m. |
| Labeling | In ACTIONS section: | In ACTIONS section: |
| | Using zone of inhibition studies, Coated VICR YL | Using zone of inhibition studies, Coated VICRYL |
| | Plus Antibacterial Suture has been shown to inhibit | Plus Antibacterial Suture has been shown to inhibit |
| | colonization of the has been shown to inhibit<br>colonization of the suture by Staphylococcus aurens | colonization of the has been shown to inhibit<br>colonization of the suture by Staphylococcus |
| | Staphylococcus epidermidis, Methicillin Resistant S. | aureus , Staphylococcus epidermidis, Methicillin |
| | aureus . Methicillin Resistant S. epidermidis and | Resistant S. aureus . Methicillin Resistant S. |
| | Escherichia coli which are microorganisms known to | epidermidis and Escherichia coli which are |
| | contribute to surgical site infections. Animal studies | microorganisms known to contribute to surgical site |
| | have demonstrated that VICRYL Plus Antibacterial | infections. Animal studies have demonstrated that |
| | suture inhibits bacterial colonization of suture after | VICR YL Plus Antibacterial suture inhibits bacterial |
| | direct in vivo challenge with bacteria. Prospectively | colonization of suture after direct in vivo challenge |
| | planned meta-analyses of randomized clinical trials | with bacteria. |
| | were performed on the use of suture containing | |
| | triclosan to lower surgical site infection rates. | |
| | Examples of such meta-analyses are referenced | |
| | below 1. 2. | |
| | Wang, Z.X., Jiang, C.P., Cao, Y., Ding, | |
| | Y.T., Systematic review and meta-analysis of<br>triclosan-coated sutures for prevention of<br>surgical site infections., Br. J. Surgery, 2013. | |
| | 2Edminston, C.E., Doud, F.C., Leaper, D. Is there<br>an evidence based argument for embracing an<br>antimierobial (triclosan) - coated suture technology<br>to reduce the risk for surgical site infections? : A<br>meta-analysis. Surgery; 2013; 154; 89-100. | |
#### Substantial Equivalence Comparison Table
{2}------------------------------------------------
{3}------------------------------------------------
DEPARTMENT OF HEALTH & HUMAN SERVICES
Image /page/3/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo is a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is a stylized image of an eagle with its wings spread, clutching a caduceus in its talons.
Public Health Service
Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002
February 28, 2014
Ethicon Incorporated Mr. Peter Cecchini Fellow, Regulatory Affairs Route 22 West, P.O. Box 151 Somerville, New Jersey 08876
Re: K132580
Trade/Device Name: Coated VICRYL* Plus Antibacterial (Polyglactin 910) Synthetic Absorbable Suture Regulation Number: 21 CFR 878.4493 Regulation Name: Absorbable poly(glycolide/1-lactide) surgical suture Regulatory Class: Class II Product Code: GAM Dated: February 10, 2014 Received: February 11, 2014
Dear Mr. Cecchini:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you; however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical
{4}------------------------------------------------
Page 2 - Mr. Peter Cecchini
device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Small Manufacturers, International and Consumer Assistance at its tollfree number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYowIndustry/default.htm. Also, please note the regulation entitled. "Misbranding by reference to premarket notification" (2) CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.
Sincerely yours,
## David Krause -S
for
Binita S. Ashar, M.D., M.B.A., F.A.C.S. Acting Director Division of Surgical Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{5}------------------------------------------------
DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration
#### . Indications for Use
510(k) Number (if known) K132580
Device Name
i
Coated VICR YL * Plus Antibacterial (Polyglactin 910) Synthetic Absorbable Suture
#### Indications for Use (Describe)
Coated VICRYL Plus Antibacterial Suture is indicated for use in general soft tissue approximation and/or ligation, except for ophthalmic, cardiovascular and neurological tissues.
Type of Use (Select one or both, as applicable)
2 Prescription Use (Part 21 CFR 801 Subpart D)
Over-The-Counter Use (21 CFR 801 Subpart C)
#### PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON A SEPARATE PAGE IF NEEDED.
#### FOR FDA USE ONLY
Concurrence of Center for Devices and Radiological Health (CDRH) (Signature)
# avid Krause
This section applies only to requirements of the Paperwork Reduction Act of 1995.
#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.