K132478 · E.M.S Electro Medical Systems S.A · EFB · Apr 11, 2014 · Dental
Device Facts
Record ID
K132478
Device Name
AIR-FLOW HANDY 3.0
Applicant
E.M.S Electro Medical Systems S.A
Product Code
EFB · Dental
Decision Date
Apr 11, 2014
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 872.4200
Device Class
Class 1
Indications for Use
The AIR-FLOW handy 3.0 Dental Handpiece is a dental handpiece intended for use in the cleaning and polishing of teeth by the projection of a mixture of water, air, and EMS prophylaxis powder onto the tooth surface. The device removes soft deposits and areas of discoloration and can be used to prepare teeth for dental procedures such as the placement of composite fillings, porcelain inlays, and laminate veneers. The device can be used to clean implant abutments and to clean teeth prior to treatments such as shade matching, fluoridation, and bleaching. The device can also be used to degrease crowns and bridges prior to placement and clean fixed bands and brackets on orthodontic appliances.
Device Story
Hand-held dental device; connects to standard dental unit turbine; delivers air, water, and prophylaxis powder mixture to tooth surfaces. Used by dental practitioners in clinical settings for cleaning, polishing, and surface preparation. Modifications from predicate include ergonomic design changes: relocated/slimmer powder chamber, reduced chamber capacity (21g), and two-part molded body. Uses AIR-FLOW CLASSIC COMFORT powder with reduced grain size (<40um) for patient comfort. Output is a controlled spray for removal of soft deposits and stains; aids in clinical procedures like restorative placement and orthodontic maintenance.
Clinical Evidence
No clinical data; bench testing only.
Technological Characteristics
Hand-held dental handpiece; connects to standard dental unit turbine; air/water/powder delivery system. Materials: molded plastic body. Dimensions: shorter/slimmer than predicate. Powder chamber capacity: 21g. Prophylaxis powder: AIR-FLOW CLASSIC COMFORT (median grain size <40um).
Indications for Use
Indicated for dental patients requiring cleaning and polishing of teeth, removal of soft deposits/discoloration, preparation for restorative procedures (fillings, inlays, veneers), cleaning of implant abutments, pre-treatment cleaning (shade matching, fluoridation, bleaching), degreasing of crowns/bridges, and cleaning of orthodontic appliances.
Regulatory Classification
Identification
A dental handpiece and accessories is an AC-powered, water-powered, air-powered, or belt-driven, hand-held device that may include a foot controller for regulation of speed and direction of rotation or a contra-angle attachment for difficult to reach areas intended to prepare dental cavities for restorations, such as fillings, and for cleaning teeth.
{0}------------------------------------------------
K132478
# APR 1 | 2014
# APPENDIX F
# 510(k) Summary for AIR-FLOW handy 3.0
{1}------------------------------------------------
# AIR-FLOW handy 3.0 Special 510(k) Premarket Notification 510(k) Summary (per 21 CFR 807.92(c))
#### 1. SPONSOR/MANUFACTURER
E.M.S. ELECTRO MEDICAL SYSTEMS S.A. Ch. de la Vuarpillière 31 CH - 1260 Nyon Switzerland
| Contact Person: | Suzanne Fassio-Hardy |
|-----------------|----------------------|
| Telephone: | +41 (0)22 994 47 00 |
Date Prepared: August 7, 2013
#### 2. DEVICE NAME:
| Proprietary Name: | AIR-FLOW handy 3.0 |
|----------------------|----------------------------------|
| Common/Usual Name: | Dental handpiece |
| Classification Name: | Dental handpiece and accessories |
# 3. PREDICATE DEVICES
- E.M.S. ELECTRO MEDICAL SYSTEMS S.A.,AIR-FLOW handy 2 (K022119) .
- E.M.S. ELECTRO MEDICAL SYSTEMS S.A., AIR-FLOW MASTER (K073284) ●
- E.M.S. ELECTRO MEDICAL SYSTEMS S.A., AIR-FLOW MASTER PIEZON . (K110173)
# 4. DEVICE DESCRIPTION
The proposed AIR-FLOW handy 3.0 is a modification of the AIR-FLOW handy 2 Dental Handpiece previously cleared under K022119. This device modification has been submitted as a Special 510(k) Premarket Notification because the indications for use for the proposed AIR-FLOW handy 3.0 are identical to the parent AIR-FLOW handy 2. The fundamental technology and design of the proposed AIR-FLOW handy 3.0 are essentially identical to the AIR-FLOW handy 2 dental handpiece.
Both the proposed AIR-FLOW handy 3.0 and the predicate AIR-FLOW handy 2 connect to a standard turbine connection on a dental operative unit and deliver a mixture of water, air, and dental powder to a treatment site.
{2}------------------------------------------------
Modifications made to the AIR-FLOW handy 2 Dental Handpiece to produce the AIR-FLOW handy 3.0 were limited to minor design changes to enhance the ergonomics of the design, including:
- . Location of the powder chamber is modified to improve the visibility of the mouth of patient by the practitioner during the treatment.
- Slimmer shape of the powder chamber to be in-line with the body of the device to . improve the visibility of the mouth of patient by the practitioner during the treatment.
- . Diameter of the powder chamber cap is reduced to be in-line with new design of the powder chamber.
- . The powder chamber capacity has been slightly decreased to 21g from 23g to fit new ergonomic design.
- The body of the handy 3.0 is made of 2 glued molded part instead of 1 molded part .
- . The handpiece is shorter and slimmer to improve ergonomics.
Accessories were included to aid in filling the powder chamber and removing residual powder from the handpiece channels.
In addition, the AIR-FLOW CLASSIC COMFORT prophylaxis powder has been added to the panel of available prophylaxis powders. The chemical composition of the AIR-FLOW CLASSIC COMFORT Powder is identical to the AIR-FLOW CLASSIC that was described in the 510(k) Premarket Notification for the AIR-FLOW MASTER (K073284). The grain size was slightly reduced from a median particle size of < 65um for the AIR-FLOW CLASSIC to <40 um for the AIR-FLOW CLASSIC COMFORT prophylaxis powder to improve patient comfort during the prophylaxis treatment.
# 5. INTENDED USE
The AIR-FLOW handy 3.0 is a dental handpiece intended for use in the cleaning and polishing of teeth by the projection of a mixture of water, air, and prophylaxis powder onto the tooth surface. The device removes soft deposits and areas of discoloration and can be used to prepare teeth for dental procedures such as the placement of composite fillings, porcelain inlays, and laminate veneers. The device can be used to clean implant abutments and to clean teeth prior to treatments such as shade matching, fluoridation, and bleaching. The device can also be used to degrease crowns and bridges prior to placement and clean fixed bands and brackets on orthodontic appliances.
{3}------------------------------------------------
#### SUMMARY OF TECHNOLOGICAL CHARACTERISTICS COMPARED TO THE PREDICATE 6. DEVICE
The proposed AIR-FLOW handy 3.0 is similar in design and materials to the AIR-FLOW handy 2 Dental Handpiece. Both the proposed AIR-FLOW handy 3.0 and the predicate AIR-FLOW handy 2 connect to a standard turbine connection on a dental operative unit and consist of a hand-held device containing air and water lines, powder chamber with cap and an AIR-FLOW nozzle. The proposed and predicate handpieces deliver a mixture of water, air, and dental powder to a treatment site. Differences between the proposed and predicate handpieces were limited to design changes to improve the ergonomics of the handpiece design and ease of use. The proposed AIR-FLOW CLASSIC COMFORT prophylaxis powder was produced with a smaller grain size to improve patient comfort.
# 7. SUMMARY OF NON-CLINICAL PERFORMANCE TESTING AS BASIS FOR SUBSTANTIAL EQUIVALENCE
Non-clinical performance testing demonstrates that the AIR-FLOW handy 3.0 fulfills the prospectively defined performance specifications. The similarities in intended use, operational characteristics, and functional technological characteristics between the AIR-FLOW handy 3.0 and the AIR-FLOW handy 2 lead to a conclusion of substantial equivalence between the proposed and predicate devices.
# 8. SUMMARY OF CLINICAL TESTING AS BASIS FOR SUBSTANTIAL EQUIVALENCE
Clinical testing was not conducted.
# 9. CONCLUSIONS DRAWN FROM NON-CLINICAL AND CLINICAL TESTING
The similarities in intended use, operational characteristics, and functional technological characteristics between the AIR-FLOW handy 3.0 and the AIR-FLOW handy 2 lead to a conclusion of substantial equivalence between the proposed and predicate devices.
{4}------------------------------------------------
Image /page/4/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter. Inside the circle is a stylized image of an eagle with its wings outstretched.
Public Health Service
Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002
#### April 11, 2014
E.M.S. Electro Medical Systems S.A. % Cynthia Nolte Dir., Med. Dev. Reg. Svces. AptivSolutions 62 Forest St., Ste 300 Marlborough, MA 01752 US
Re: K132478
> Trade/Device Name: Air-flow handy 3.0 Regulation Number: 21 CFR 872.4200 Regulation Name: Dental Handpiece Regulatory Class: Class I Product Code: EFB Dated: February 11, 2014 Received: February 12, 2014
Dear Dr. Cynthia Nolte:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{5}------------------------------------------------
#### Page 2 - Cynthia Nolte
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Small Manufacturers, International and Consumer Assistance at its tollfree number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled. "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638 2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDeyices/ResourcesforYou/Industry/default.htm.
Sincerely yours,
Image /page/5/Picture/8 description: The image contains the words "Mary S. Runner" in a bold, sans-serif font. Below the name is the acronym "FDA", which is likely an abbreviation for a government agency. The text is black and the background is white.
Erin I. Keith, M.S. Acting Director Division of Anesthesiology, General Hospital. Respiratory, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{6}------------------------------------------------
### Indications for Use Statement
510(k) Number (if known): K132478
Device Name: AIR-FLOW handy 3.0
Indications for Use:
The AIR-FLOW handy 3.0 Dental Handpiece is a dental handpiece intended for use in the cleaning and polishing of teeth by the projection of a mixture of water, air, and EMS prophylaxis powder onto the tooth surface. The device removes soft deposits and areas of discoloration and can be used to prepare teeth for dental procedures such as the placement of composite fillings, porcelain inlays, and laminate veneers. The device can be used to clean implant abutments and to clean teeth prior to treatments such as shade matching, fluoridation, and bleaching. The device can also be used to degrease crowns and bridges prior to placement and clean fixed bands and brackets on orthodontic appliances.
Prescription Use X (Part 21 CFR 801 Subpart D) AND/OR
Over-The-Counter Use (21 CFR 807 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE OF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Sheena A. Green-S
2014.04.12 20:06:36 -04'00'
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.