Centricity Universal Viewer Zero Footprint client is a device that displays medical images, data from various imaging sources, and other healthcare information sources. Medical images and data can be viewed, communicated, processed and displayed within a computer network or on a workstation. The device may be used to provide images for diagnostic purposes by trained professionals. Typical users of this system are authorized individuals and trained healthcare professionals who view medical images and data. Mammographic images may only be interpreted using a monitor compliant with requirements of local regulations and must meet other technical specifications reviewed and accepted by the local regulatory agencies. Contraindications: Centricity Universal Viewer Zero Footprint client is contraindicated for the use of lossy compressed mammographic images. Lossy compressed mammographic images and digitized film screen images must not be reviewed for primary image interpretations.
Device Story
Centricity Universal Viewer Zero Footprint (ZFP) client is a web-based medical software system for remote access and review of medical images and reports. ZFP functions as an HTML5-based viewer running in standard web browsers on off-the-shelf hardware. It does not create or alter medical images; it retrieves data from Centricity Clinical Archive, Centricity PACS, or DICOM-compliant archives. Used by physicians, radiologists, nurses, and technicians in clinical settings for diagnostic interpretation and post-diagnostic review. Features include side-by-side comparison, URL-based patient access, and multi-frame cine playback. When accessed via iPad, it is restricted to review-only mode and not for primary diagnosis. Output is displayed on compliant monitors, enabling clinicians to make diagnostic decisions based on retrieved images. Benefits include remote access to diagnostic-quality images across network-connected workstations.
Clinical Evidence
No clinical studies were required to support substantial equivalence. Evidence consists of non-clinical verification and validation, including risk analysis, requirements/design reviews, usability analysis, and unit/integration/regression/system testing.
Technological Characteristics
Software-only device running on off-the-shelf hardware. HTML5-based viewer architecture. Supports DICOM-compliant archives. Connectivity via network/web browser. Features include UTF-16 encoding, multi-frame cine playback, and secure token authentication. No specific hardware materials or energy sources defined as it is a software-only system.
Indications for Use
Indicated for trained healthcare professionals and authorized individuals to view, communicate, process, and display medical images and data from various sources for diagnostic purposes. Contraindicated for primary interpretation of lossy compressed mammographic images and digitized film screen images.
Regulatory Classification
Identification
A medical image management and processing system is a device that provides one or more capabilities relating to the review and digital processing of medical images for the purposes of interpretation by a trained practitioner of disease detection, diagnosis, or patient management. The software components may provide advanced or complex image processing functions for image manipulation, enhancement, or quantification that are intended for use in the interpretation and analysis of medical images. Advanced image manipulation functions may include image segmentation, multimodality image registration, or 3D visualization. Complex quantitative functions may include semi-automated measurements or time-series measurements.
Special Controls
*Classification.* Class II (special controls; voluntary standards—Digital Imaging and Communications in Medicine (DICOM) Std., Joint Photographic Experts Group (JPEG) Std., Society of Motion Picture and Television Engineers (SMPTE) Test Pattern).
Predicate Devices
GE Healthcare Centricity PACS-IW with Universal Viewer (K123174)
Submission Summary (Full Text)
{0}------------------------------------------------
GE Health 510(k) Premarket Notification Submission Centricity Universal Viewer Zero Footprint client Section 5: 510(k) Summary
2013
## 510k Summary
In accordance with 21 CFR 807.92 the following summary of information is provided:
> Original filing on June 24th, 2013 Date: Supplemental Information on September 3rd, 2013
Submitter: GE Healthcare 540 West Northwest Highway Barrington, IL 60010
Primary Contact Person:
Nicole Landreville Regulatory Affairs Manager GE Healthcare Phone: 289-208-2365 Fax: 847-277-4506
Secondary Contact Person:
Cheryl Bork Regulatory Affairs Manager GE Healthcare Phone: 847-277-6038 Fax: 847-277-5240
Device Trade Name: Centricity Universal Viewer Zero Footprint client
Picture Archiving and Communication System Common/Usual Name:
Classification Names: 21 CFR 892.2050, System, Image Processing, Radiological
Product Code: LLZ
Predicate Device: K123174 - GE Healthcare Centricity PACS-IW with Universal Viewer
{1}------------------------------------------------
Image /page/1/Picture/0 description: The image shows the General Electric (GE) logo. The logo consists of the letters "GE" intertwined within a circle. The letters are stylized and appear to be hand-drawn or calligraphic. The logo is black and white.
· Device Description: Centricity Universal Viewer Zero Footprint client (ZFP) is a medical software system that is intended for multiple users to remotely access the images stored in a compatible Picture Archiving and Communication System, from compatible computers or workstations on a network, for the purpose of review, diagnostic interpretation and post-diagnostic review of medical images and reports.
> ZFP is a viewer that does not produce any original medical images nor does it alter any images or medical data. Specifically, ZFP is an HTML 5 based viewer which runs within a compatible web browser and supports secure transmission of data.
> ZFP operates within an operating environment that meets defined minimum specifications (see Section 11.1 for Hardware Description). Both the client and server software of ZFP are only for use with off the shelf hardware technology that meets defined minimum specifications.
ZFP can access data created in multiple systems when stored in Centricity™ Clinical Archive solution and Centricity PACS. Additionally, ZFP can access data from any DICOM compliant archive using Enterprise Archive for query retrieve and data moves.
Authorized users can use the diagnostic quality images for diagnostic purposes. These Authorized users include but are not limited to physicians, radiologists, nurses, medical technicians, and assistants.
{2}------------------------------------------------
Image /page/2/Picture/0 description: The image shows the General Electric (GE) logo. The logo consists of the letters 'G' and 'E' intertwined within a circular border. The letters and the border are black, while the background is white.
Intended Use: Centricity Universal Viewer Zero Footprint client is a device that displays medical images, data from various imaging sources, and other healthcare information sources. Medical images and data can be viewed, communicated, processed and displayed within a computer network or on a workstation. The device may be used to provide images for diagnostic purposes by trained professionals.
> Typical users of this system are authorized individuals and trained healthcare professionals who view medical images and data.
Mammographic images may only be interpreted using a monitor compliant with requirements of local regulations and must meet other technical specifications reviewed and accepted by the local regulatory agencies.
#### Contraindications:
Centricity Universal Viewer Zero Footprint client is contraindicated for the use of lossy compressed mammographic images. Lossy compressed mammographic images and digitized film screen images must not be reviewed for primary image interpretations.
Discussion regarding the modifications to the Intended Use / Indications ・
for Use
The Intended Use / Indications for Use statement was modified from the Predicate device to clarify the following:
The Subject Device, ZFP, is designed to display medical images, data from various imaging sources and other healthcare information sources while Centricity PACS-IW with Universal Viewer Web Client v.5.0 is designed for a broader set of functions, which include the storage of images and data, the communication of images and data as well as the processing of images and data.
To clarify the conditions regarding appropriate diagnostic usage. The verbiage was clarified to explicitly describe that for mammographic images the user needs to use monitors compliant with requirements of local regulations as regulated by the local regulatory agencies (such as FDA). The use of lossy compressed images is now stated in a separate contraindications statement to raise the importance of using the appropriate type of mammographic images to support primary image interpretations.
{3}------------------------------------------------
Image /page/3/Picture/0 description: The image shows the General Electric (GE) logo. The logo consists of the letters 'G' and 'E' intertwined within a circular border. The logo is black and white.
Discussion regarding the modifications to the Intended Use / Indications for Use (con't) The ZFP's Intended Use / Indications for Use statement contains a subset of the predicate device's Intended Use / Indications for Use. These modifications do not impact the equivalence to the predicate in terms of intended use. Specific differences between the Predicate and the Subject device are included in the Section 12: Substantial Equivalence.
Technology: Centricity Universal Viewer Zero Footprint client displays medical images and other information from various data sources. The information can be processed and displayed across computer networks at dispersed locations.
> ZFP is a software-only device that runs on commercially available off-the-shelf computer hardware platforms.
The ZFP device employs the same fundamental scientific technology as its predicate device, Centricity PACS-IW with Universal Viewer with Zero Footprint as an option cleared under K123174, with the following modifications:
- 1. ZFP now provides compatibility with Centricity PACS.
- 2. New ZFP enhancements provide support for the following:
- Side-by-side Comparison .
- Patient level inbound URL launch .
- Secure Inbound URL token authentication .
- Internet Explorer 7 & 8 support via Google . Chrome Frame
- Internet Explorer 9 & 10 support t
- Safari, Firefox support ●
- Localizable multiple date format ●
- UTF-16 Character Encoding Scheme �
- Up to 4 multi-frame cine running in parallel .
- Zoom and pan during cine .
- ZFP may now be accessed from an iPad with internet 3. access. When accessed from the Apple® iPad®, ZFP can only be used in review only mode and is not meant for primary diagnosis. Other mobile devices. smartphones and tablets have not been validated.
{4}------------------------------------------------
Image /page/4/Picture/0 description: The image shows the General Electric (GE) logo. The logo consists of the letters "GE" intertwined and enclosed within a circle. The letters and the circle are in black, creating a strong contrast against the white background. The logo is a well-known symbol associated with the General Electric company.
GE Healtha 510(k) Premarket Notification Submission Centricity Universal Viewer Zero Footprint client Section 5: 510(k) Summary
## Determination of Substantial Equivalence:
# Summary of Non-Clinical Tests
The software documentation was provided at a moderate level of concern following the FDA's "Guidance for the Content of Premarket Submissions for Software Contained in Medical Devices". Universal Viewer ZFP client complies with voluntary standards as detailed in this premarket notification submission (Refer to Section 9 - Declaration of Conformity and Summary Reports).
The following quality assurance measures were applied to the development of the system:
- Risk Analysis .
- Requirements Reviews .
- Design Reviews .
- Usability Analysis .
- Testing on unit level (Verification) .
- Integration testing (Verification) .
- Regression testing (Verification) .
- System testing (Verification) .
- Simulated use testing (Validation)
### Summary of Clinical Tests:
The subject of this premarket notification submission, Centricity Universal Viewer Zero Footprint client, did not require clinical studies to support substantial equivalence.
Conclusion:
Comparison of the Intended Uses / Indications for Use, the technological characteristics, and performance specifications demonstrate the functional equivalence of the subject device to the predicate device.
Verification and Validation testing results demonstrate that no adverse effects have been introduced by these differences.
The Centricity Universal Viewer Zero Footprint client device will continue to have an intended use and functionality fitting within the definition of 21 CFR 892.2050, Picture Archiving and Communication Systems, Product Code LLZ.
Information provided in this premarket notification submission supports the Centricity Universal Viewer Zero Footprint client medical device to be as safe, as effective and substantially equivalent to its predicate device.
{5}------------------------------------------------
DEPARTMENT OF HEALTH & HUMAN SERVICES
Image /page/5/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized caduceus symbol, which features three parallel lines that curve and resemble a stylized human form. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular fashion around the symbol. The text is in all capital letters and is oriented to follow the curve of the circle.
Public Health Service
Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002
September 17, 2013
GE Healthcare % Ms Nicole Landreville Regulatory Intelligence Manager 540 West Northwest Highway BARRINGTON IL 60010
Re: K131977
Trade/Device Name: Centricity Universal Viewer Zero Footprint client Regulation Number: 21 CFR 892.2050 Regulation Name: Picture archiving and communications system Regulatory Class: II Product Code: LLZ Dated: September 4, 2013 Received: September 6, 2013
Dear Ms. Landreville:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug. and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complics with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
{6}------------------------------------------------
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Small Manufacturers, International and Consumer Assistance at its tollfree number (800) 638 2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industrv/default.htm.
Sincerely yours.
Smh)
for
Janine M. Morris Director, Division of Radiological Health Office of In Vitro Diagnostics and Radiological Health Center for Devices and Radiological Health
Enclosure
{7}------------------------------------------------
# Indications for Use
510(k) Number (if known): K131977
Device Name: Centricity Universal Viewer Zero Footprint client
Indications for Use:
Centricity Universal Viewer Zero Footprint client is a device that displays medical images, data from various imaging sources, and other healthcare information sources. Medical images and data can be viewed, communicated, processed and displayed within a computer network or on a workstation. The device may be used to provide images for diagnostic purposes by trained professionals.
Typical users of this system are authorized individuals and trained healthcare professionals who view medical images and data.
Mammographic images may only be interpreted using a monitor compliant with requirements of local regulations and must meet other technical specifications reviewed and accepted by the local regulatory agencies.
Contraindications:
Centricity Universal Viewer Zero Footprint client is contraindicated for the use of lossy compressed mammographic images. Lossy compressed mammographic images and digitized film screen images must not be reviewed for primary image interpretations.
Prescription Use X (Part 21 CFR 801 Subpart D) AND/OR
Over-The-Counter Use (21 CFR 801 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of In Vitro Diagnostics and Radiological Health (OIR)
\$m_{h}p).
(Division Sign-Off) Division of Radiological Health Office of In Vitro Diagnostics and Radiological Health
510(k)
Page 1 of 1
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.