IQQA-Liver Multimodality is a PC-based, self-contained, non-invasive image analysis software application for reviewing multiphase images derived from various sources (e.g. CT scanners, MR scanners). Combining image viewing, processing and reporting tools, the software is designed to support the visualization, evaluation and reporting of liver and physician-identified lesions. The software supports a workflow based on automated image registration for viewing and analyzing multiphase volume datasets. It includes tools for interactive segmentation and labeling of liver segments and vascular structures. The software provides for manual or interactive segmentation of physician-identified lesions. interactive definition of virtual resection plane, and allows for regional volumetric analysis of such lesions in terms of size, position, margin and enhancement pattern, providing information for physician`s evaluation and treatment planning. The software is designed for use by trained professionals, including physicians and technicians. Image source: DICOM.
Device Story
PC-based software processes DICOM-formatted CT/MR images; performs automated image registration for multi-phase volume datasets; provides visualization tools (MPR, MIP, MinIP, volume rendering) and interactive segmentation/labeling of liver segments, vascular structures, and lesions. User inputs include seed points and boundary editing. Output includes quantitative measurements (size, position, margin, enhancement pattern), virtual resection plane definition, and automated reports. Used by physicians/technicians in clinical settings to support assessment and treatment planning. Final patient management decisions remain with the physician.
Clinical Evidence
Bench testing performed per FDA software guidance. Supplemental validation conducted at two clinical sites where physicians used v2.0 software to review multiphase CT/MR liver images to validate major functionalities and provide feedback.
Indicated for trained professionals (physicians/technicians) to review multiphase CT/MR images for visualization, evaluation, and reporting of liver and physician-identified lesions, including volumetric analysis and virtual resection planning.
Regulatory Classification
Identification
A medical image management and processing system is a device that provides one or more capabilities relating to the review and digital processing of medical images for the purposes of interpretation by a trained practitioner of disease detection, diagnosis, or patient management. The software components may provide advanced or complex image processing functions for image manipulation, enhancement, or quantification that are intended for use in the interpretation and analysis of medical images. Advanced image manipulation functions may include image segmentation, multimodality image registration, or 3D visualization. Complex quantitative functions may include semi-automated measurements or time-series measurements.
Special Controls
*Classification.* Class II (special controls; voluntary standards—Digital Imaging and Communications in Medicine (DICOM) Std., Joint Photographic Experts Group (JPEG) Std., Society of Motion Picture and Television Engineers (SMPTE) Test Pattern).
{0}------------------------------------------------
K131498
Page 1 of 2
## EDDA Technology 510(k) Summary 5 Independence Way Princeton, N.J 08540 Tel: 609-919-9889 Fax: 609-919-9779 Contact: Xiaolan Zeng, Executive Vice President Date prepared: May 21, 2013
JUL 2 5 2013
- 1. Identification of the Device: Proprietary - Trade Name: IQQA-Liver Multimodality Software Classification Name: System. Image Processing, Radiological, Product Code LLZ Common/Usual Name: Radiological Image Processing System
- Equivalent legally marketed devices: 2.
| Manufacturer | Name of the Predicate Device | FDA 510(k)<br>Number | FDA Clearance<br>Date |
|----------------------------------|-----------------------------------------------|----------------------|-----------------------|
| GE Medical Systems | Volume Viewer Plus | K041521 | 06/22/2004 |
| Mevis Technology<br>GMBH & CO.KG | Mevis LiverAnalyser / LiverViewer<br>Software | K051528 | 07/20/2005 |
| EDDA Technology | IQQA-Liver Software (v1.0) | K061696 | 11/13/2006 |
| Pathfinder Therapeutics | PlaniSight Linasys | K082228 | 09/22/2008 |
- 3. Indications for Use (intended use):
100A-Liver Multimodality is a PC-based, self-contained, non-invasive image analysis software application for reviewing multiphase images derived from various sources (e.g. CT scanners, MR scanners). Combining image viewing, processing and reporting tools, the software is designed to support the visualization, evaluation and reporting of liver and physician-identified lesions.
The software supports a workflow based on automated image registration for viewing and analyzing multiphase volume datasets. It includes tools for interactive segmentation and labeling of liver segments and vascular structures. The software provides for manual or interactive segmentation of physician-identified lesions. interactive definition of virtual resection plane, and allows for regional volumetric analysis of such lesions in terms of size, position, margin and enhancement pattern, providing information for physician`s evaluation and treatment planning.
The software is designed for use by trained professionals, including physicians and technicians. Image source: DICOM.
- 4. Description of the device: The IQQA-Liver Multimodality Software is a self-contained, noninvasive radiographic image analysis application that is designed to run on standard PC hardware. The image data utilized is derived from sources including CT and MR scanners, and of DICOM format. Combining image processing, viewing and reporting tools, the software supports the visualization, evaluation and reporting of liver and physician identified liver lesions. Viewing tools include various standard visualization modes (e.g. original DICOM 2D image viewing, window level adjustment, svnchronized viewing of multi-phase sets, Multi-Planar Reformation (MPR) in any plane (orthogonal, oblique, curved), 3D views in rendering
{1}------------------------------------------------
Image /page/1/Picture/0 description: The image shows the text "K13/498 Page 2 of 2" in a handwritten style. The text is written in black ink on a white background. The numbers and letters are clearly legible, and the overall impression is that of a document page number.
mode (MIP. MinIP, volume rendering), and their relationship to originally acquired images from modality). Analysis and evaluation tools include segmentation of structures utilizing user input of seeding points, user tracing and interactive editing, interactive labeling of segmented areas. quantitative measurement derived from segmentation and labeling results, and the measurement of distance between physician specified structures and landmarks. Reporting tools in the software automatically assemble information (including physician identified lesion focations, measurement information. physician-input lesion characterization. Iesion ROI images across multi-phases, information of liver lobes and vessels, and illustrative snapshots of the GUI taken by user) for physician's confirmation and for further diagnosis note input.
The IQQA-Liver Multimodality software supports a workflow based on automated registration for viewing and analyzing multi-phase volume datasets. The software automatically matches the spatial location of original DICOM images across multi-phases, and provides synchronized viewing of multi-phase dataset to aid visualization. The software further includes tools for interactive segmentation and interactive labeling of liver segments and vascular structures (such as liver lobes. vessels and ducts and major branches), thus facilitation of spatial relationship between suspicious liver lesions and specified anatomical structures/landmarks. The tools also allow for interactive segmentation of physician-identified lesions using user input of seed points and boundary editing, interactive definition of virtual resection plane, interactive ' adjustment of user specified margin size around the lesion, and regional analysis of such lesions with respect to size, shape, position, margin, enhancement pattern etc, thus providing information to support physician's assessment of lesion and treatment plans.
The software is designed for use by trained professionals, including physicians and technicians. Physicians make all final patient management decisions.
- 5. Safety and Effectiveness. comparison to predicate devices:
The IQQA-Liver Multimodality software package has the same intended use as the predicate devices, and is substantially equivalent in performance. Any technological differences in the IOOA-Liver Multimodality software package and the predicate devices do not raise any new potential safety risks. In conclusion. the IQQA-Liver Multimodality software tool is substantially equivalent to the predicate devices.
- 6. Testing Information and Conclusion
In all material respects, the IQQA-Liver Multimodality Software is substantially equivalent to the predicate systems. Testing was performed according to internal company procedures in recognition of the FDA guidance document for 510(k) software. Software testing and validation were done according to written test protocols established before testing was conducted. Test results were reviewed by designated technical professionals before software proceeded to release. Test results support the conclusion that actual device performance satisfies the design intent. Additionally, to supplement the software validation for IQQA-Liver Multimodality Software, EDDA Technology has conducted software testing at two clinical sites. The purpose of the testing is to have physicians use the v2.0 software application to review multiphase CT and MR images of the liver, validate major functionalities provided by the system, and provide feedback along the line of the intended use of the system.
{2}------------------------------------------------
Image /page/2/Picture/0 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES USA" arranged around the perimeter. Inside the circle is a stylized emblem featuring a symbol that resembles an abstract caduceus or a stylized representation of human figures. The emblem is composed of three curved lines that converge and then split into two wavy lines at the bottom.
Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002
July 25, 2013
EDDA Technology, Inc. % Daniel Kamm. PE Regulatory Engineer, Submission Correspondent 5 Independence Way PRINCETON NJ 08540
Re: KI31498
Trade/Device Name: IOOA-Liver Multimodality Software Regulation Number: 21 CFR 892.2050 Regulation Name: Picture archiving and communications system Regulatory Class: II Product Code: LLZ Dated: May 21, 2013 Received: May 30, 2013
Dear Mr. Kamm:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
{3}------------------------------------------------
Page 2 - Mr. Kamm
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Small Manufacturers, International and Consumer Assistance at its tollfree number (800) 638 2041 or (301) 796-7100 or at its Internet address
hup://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportalProblem/delault.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.
Sincerely yours,
Sm. 7)
for
Janine M. Morris Director, Division of Radiological Health Office of In Vitro Diagnostics and Radiological Health Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
## Indications for Use
510(k) Number (if known): K131498
Device Name: 1QQA-Liver Multimodality Software
Indications for Use:
IQQA-Liver Multimodality is a PC-based, self-contained, non-invasive image analysis software application for reviewing multiphase images derived from CT scanners and MR scanners. Combining image viewing, processing and reporting tools, the software is designed to support the visualization, evaluation and reporting of liver and physician-identified lesions.
The software supports a workflow based on automated image registration for viewing and analyzing multiphase volume datasets. It includes tools for interactive segmentation and labeling of liver segments and vascular structures. The software provides functionalities for manual or interactive segmentation of physician-identified lesions, interactive definition of virtual resection plane, and allows for regional volumetric analysis of such lesions in terms of size, position, margin and enhancement pattern, providing information for physician's evaluation and treatment planning.
The software is designed for use by trained professionals, including physicians and technicians. Image source: DICOM.
Prescription Use __X __ . (Part 21 CFR 801 Subpart D) AND/OR
Over-The-Counter Use (21 CFR 801 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of In Vitro Diagnostics and Radiological Health (OIR)
Smh.7)
(Division Sign-Off) Division of Radiological Health Office of In Vitro Diagnostics and Radiological Health
> K131498 510(k) ==
Page 1 of 1
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.