SYNTHES 2.7MM AND 3.5MM VARIABLE ANGLE LCP MIDFOOT/HINDFOOT SYSTEM

K131186 · Synthes (USA) Products, LLC · HRS · Oct 8, 2013 · Orthopedic

Device Facts

Record IDK131186
Device NameSYNTHES 2.7MM AND 3.5MM VARIABLE ANGLE LCP MIDFOOT/HINDFOOT SYSTEM
ApplicantSynthes (USA) Products, LLC
Product CodeHRS · Orthopedic
Decision DateOct 8, 2013
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 888.3030
Device ClassClass 2
AttributesTherapeutic, Pediatric

Indications for Use

The Synthes 2.7 and 3.5 mm Variable Angle LCP Midfoot System is indicated for fixation of osteotomies, fusions, fractures, nonunions and replantations of small bones and small bone fragments in adult and adolescent (12 -21 years) patients, including the foot and ankle, and particularly in osteopenic bone. The Synthes 3.5mm Low Profile Cortical Screws are intended to be used as stand-alone bone screws, or in a plate-screw system for internal bone fixation for bone fractures, fusions, osteotomies, and non-unions of the clavicle, scapula, olecranon, humerus, hand, radius, ulna, pelvis, tibia, femur, fibula, and foot in adults, and in both children (2-12 years) and adolescents (12-21 years) in which growth plates have fused or in which growth plates will not be crossed by the screw fixation. The Synthes 3.5mm Cortex Screws are intended to be used as stand-alone bone screws, or in a platescrew system for internal bone fixation for bone fractures, osteotomies, and non-unions of the clavicle, scapula, olecranon, humerus, hand, radius, ulna, pelvis, tibia, and foot in adults, and in both children (2-12 years) and adolescents (12-21 years) in which growth plates have fused or in which growth plates will not be crossed by the screw fixation.

Device Story

System comprises metallic bone plates and various screw types (cortical, locking, variable angle, cannulated, etc.) for internal fixation of fractures, fusions, and osteotomies. Used by orthopedic surgeons in clinical settings. Plates provide structural stabilization to bone fragments; variable angle locking technology allows surgeon-defined screw trajectory relative to plate. Benefits include stabilization of small bone fractures and support for osteopenic bone. System is a passive mechanical implant; no electronic or software components.

Clinical Evidence

Bench testing only; fatigue strength testing and engineering analyses performed to verify mechanical performance.

Technological Characteristics

Metallic bone fixation system; materials include Stainless Steel, Commercially Pure Titanium-Grade 4, and Titanium Alloy (TAN). Low-profile plate design; variable angle locking mechanism. Passive mechanical device; no energy source or software.

Indications for Use

Indicated for fixation of osteotomies, fusions, fractures, nonunions, and replantations of small bones/fragments in adults and adolescents (12-21 years), including foot and ankle, particularly in osteopenic bone. Specific screws indicated for additional skeletal sites (clavicle, scapula, olecranon, humerus, hand, radius, ulna, pelvis, tibia, femur, fibula) in adults, children (2-12 years), and adolescents where growth plates are fused or not crossed.

Regulatory Classification

Identification

Single/multiple component metallic bone fixation appliances and accessories are devices intended to be implanted consisting of one or more metallic components and their metallic fasteners. The devices contain a plate, a nail/plate combination, or a blade/plate combination that are made of alloys, such as cobalt-chromium-molybdenum, stainless steel, and titanium, that are intended to be held in position with fasteners, such as screws and nails, or bolts, nuts, and washers. These devices are used for fixation of fractures of the proximal or distal end of long bones, such as intracapsular, intertrochanteric, intercervical, supracondylar, or condylar fractures of the femur; for fusion of a joint; or for surgical procedures that involve cutting a bone. The devices may be implanted or attached through the skin so that a pulling force (traction) may be applied to the skeletal system.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ ## K131186 page 1 of 2 ## Attachment 3: Revised 510(k) Summary The following is a summary of 510(k) safety and effectiveness information in accordance with 21 CFR 807.92. | Sponsor Information | | |-------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Date Prepared | August 29, 2013 | | Company Name | Synthes | | Address | 1301 Goshen Parkway<br>West Chester, PA 19380 | | Contact Person | Rebecca G. Reiter | | Title | Regulatory Affairs Specialist | | Phone | (610) 719-1268 | | Fax | 484-356-9682 | | Device Information | | | Proprietary Name | Synthes 2.7mm and 3.5mm Variable Angle LCP Midfoot/Hindfoot System | | Device | Plate, fixation, bone | | Regulation | Single/multiple component metallic bone fixation appliances and accessories | | Description | Screw, fixation, bone | | Product Code | HRS. HWC | | Submission Type | Traditional 510(k) | | Regulation | 888.3030, 888.3040 | | Device Class | Class II | | Predicate<br>Device(s): | Synthes Cortical Screws (K112583)<br>Synthes 3.5mm Low Profile Cortical Screws (K111230)<br>Arthrex Low Profile Screws (K103705)<br>Synthes Locking Calcaneal Plates (K991407)<br>Synthes 2.4/2.7 VA LCP Forefoot/Midfoot System (K100776)<br>Synthes 2.4mm/2.7mm Locking Talus Plate (K071264)<br>Stryker Foot Plating System (K063875) | . ﺰ ﻟﻠﻌﺐ 47 {1}------------------------------------------------ | | The system is a collection of plates used for fixation of fractures of the foot and<br>ankle in adults and adolescents (12-21) in which the growth plates have fused or<br>in which the growth plates will not be crossed by the plate system. The complete<br>system includes the following plate types: | |------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Device<br>Description: | • 2.4mm/2.7mm Variable Angle Locking Talus Plate<br>• 2.7mm Variable Angle Locking Calcaneal Plate<br>• 2.7mm Variable Angle Locking Anterolateral Calcaneal Plate<br>• 3.5mm Variable Angle Locking Compression Medial Column Fusion<br>Plate | | | The system accepts various screw fixation options such as existing cortical,<br>locking, variable angle locking, low profile, cannulated locking, cannulated<br>conical and metaphyseal screws. The plates are low profile in design and offered<br>in variations of Stainless Steel, Commercially Pure Titanium-Grade 4, and<br>Titanium Alloy (TAN). When used in conjunction with a plate system, the system<br>indications apply to the entire construct, including the screws. | | Intended Use | | The Synthes 2.7mm and 3.5mm Variable Angle LCP Midfoot/Hindfoot System is indicated for fixation i of osteotomies, fusions, fractures, nonunions and replantations of small bones and small bone fragments in adult and adolescent (12 -21 years) patients, including the foot and ankle, and particularly in osteopenic bone. The Synthes 3.5mm Low Profile Cortical Screws and the Synthes 3.5mm Cortex Screws are intended to be used as stand-alone bone screws, or in a plate-screw system for internal bone fixation for bone fractures, fusions, osteotomies, and non-unions of the clavicle, scapula, olecranon. humerus, hand, radius, ulna, pelvis, tibia, femur, fibula, and foot in adults, and in both children (2-12 years) and adolescents (12-21 years) in which growth plates have fused or in which growth plates will not be crossed by the screw fixation. ### Substantial Equivalence Both the Synthes 2.7mm and 3.5mm Variable Angle LCP MidfootHindfoot System and predicate systems have similar indications, design characteristics, and performance characteristics. Fatigue strength testing, as well as engineering analyses were completed for the plates included in the Synthes 2.7mm and 3.5mm Variable Angle LCP Midfoot/Hindfoot System, demonstrating equal to or greater strength in comparison to the predicate devices and constructs. The subject Synthes 3.5mm Low Profile Cortex and Synthes 3.5mm Cortex Screws share the same indications for use, product technology. and design characteristics. No design changes have been made to the Synthes 3.5mm Cortex and 3.5mm Low Profile cortex screws. No new questions of safety and efficacy are raised as a result of the expanded indications statements. {2}------------------------------------------------ Image /page/2/Picture/0 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES USA" arranged around the perimeter. Inside the circle is an abstract symbol resembling a stylized caduceus or a bird-like figure, rendered in a bold, black line. #### DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002 October 8, 2013 Synthes (USA) Products, LLC Ms. Rebecca Reiter Regulatory Affairs Specialist 1301 Goshen Parkway West Chester, Pennsylvania 19380 Re: K131186 Trade/Device Name: Synthes 2.7mm and 3.5mm Variable Angle LCP Midfoot/Hindfoot System Regulation Number: 21 CFR 888.3030 Regulation Name: Single/multiple component metallic bone fixation appliances and accessories Regulatory Class: Class II Product Code: HRS, HWC Dated: August 29, 2013 Received: September 3, 2013 Dear Ms. Reiter: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you; however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 {3}------------------------------------------------ #### Page 2 - Ms. Rebecca Reiter CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act): 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Small Manufacturers, International and Consumer Assistance at its tollfree number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled. "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportalProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Sincerely yours. Image /page/3/Picture/7 description: The image shows the text "Erin | Keith" in a simple, bold font. The name "Erin" is on the left, followed by a vertical bar, and then the name "Keith" on the right. The text is black against a white background. for Mark N. Melkerson Director Division of Orthopedic Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {4}------------------------------------------------ #### Indications for Use Statement 510(k): K131186 Device Name: Synthes 2.7mm and 3.5mm Variable Angle LCP MidfootHindfoot System Indications for Use: The Synthes 2.7 and 3.5 mm Variable Angle LCP Midfoot System is indicated for fixation of osteotomies, fusions, fractures, nonunions and replantations of small bones and small bone fragments in adult and adolescent (12 -21 years) patients, including the foot and ankle, and particularly in osteopenic bone. The Synthes 3.5mm Low Profile Cortical Screws are intended to be used as stand-alone bone screws, or in a plate-screw system for internal bone fixation for bone fractures, fusions, osteotomies, and non-unions of the clavicle, scapula, olecranon, humerus, hand, radius, ulna, pelvis, tibia, femur, fibula, and foot in adults, and in both children (2-12 years) and adolescents (12-21 years) in which growth plates have fused or in which growth plates will not be crossed by the screw fixation. The Synthes 3.5mm Cortex Screws are intended to be used as stand-alone bone screws, or in a platescrew system for internal bone fixation for bone fractures, osteotomies, and non-unions of the clavicle, scapula, olecranon, humerus, hand, radius, ulna, pelvis, tibia, and foot in adults, and in both children (2-12 years) and adolescents (12-21 years) in which growth plates have fused or in which growth plates will not be crossed by the screw fixation. Prescription Use X (Per 21 CFR 801.109) AND/OR Over-The-Counter Use (21 CFR 807 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) # Elizabeth L. Frank -S Division of Orthopedic Devices
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...