K131097 · Implant Direct Sybron Manufacturing, LLC · DZE · Aug 22, 2013 · Dental
Device Facts
Record ID
K131097
Device Name
LEGACY3 6MM LENGTH IMPLANTS
Applicant
Implant Direct Sybron Manufacturing, LLC
Product Code
DZE · Dental
Decision Date
Aug 22, 2013
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 872.3640
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
Legacy3 6mm Length implants consist of two-piece implants for one-stage or two-stage surgical procedures. These implants are intended for use in partially and fully edentulous upper and lower jaws in support of single or multiple-unit restorations and terminal or intermediate abutment support for fixed bridgework. Implants can be indicated for immediate loading when good primary stability has been achieved and with appropriate occlusal loading.
Device Story
Legacy3 6mm implants are two-piece, root-form dental implants; designed for one-stage or two-stage surgical procedures in edentulous jaws. Features tapered body with double-lead buttress threads and quadruple-lead coronal threads; facilitates insertion in undersized sockets to enhance initial stability. Available in multiple diameters (3.7–7.0 mm) with Soluble Blasted Media (SBM) or HA-coated surfaces. Internal connection utilizes leading bevel, hex, and 1-72UNF thread. Used by dental surgeons in clinical settings to support single/multiple-unit restorations or fixed bridgework. Output is a stable foundation for prosthetic components; aids in restoring masticatory function for patients where longer implants are anatomically unsuitable. Device is a line extension of previously cleared Legacy implants; maintains prosthetic compatibility with existing surgical armamentaria.
Clinical Evidence
No clinical testing was performed. Substantial equivalence is supported by bench testing, including static compression, fatigue, implant driving torque, and abutment/screw torque-to-failure tests per ISO 14801 and FDA guidance. Comparative 3D CAD modeling and pull-out testing in simulated bone were used to demonstrate equivalent osseointegration surface area and retention.
Indicated for partially and fully edentulous upper and lower jaws in adults requiring single or multiple-unit restorations or terminal/intermediate abutment support for fixed bridgework; suitable for immediate loading given sufficient primary stability and appropriate occlusal loading.
Regulatory Classification
Identification
An endosseous dental implant is a prescription device made of a material such as titanium or titanium alloy that is intended to be surgically placed in the bone of the upper or lower jaw arches to provide support for prosthetic devices, such as artificial teeth, in order to restore a patient's chewing function.
Special Controls
*Classification.* (1) Class II (special controls). The device is classified as class II if it is a root-form endosseous dental implant. The root-form endosseous dental implant is characterized by four geometrically distinct types: Basket, screw, solid cylinder, and hollow cylinder. The guidance document entitled “Class II Special Controls Guidance Document: Root-Form Endosseous Dental Implants and Endosseous Dental Implant Abutments” will serve as the special control. (See § 872.1(e) for the availability of this guidance document.)(2)
*Classification.* Class II (special controls). The device is classified as class II if it is a blade-form endosseous dental implant. The special controls for this device are:(i) The design characteristics of the device must ensure that the geometry and material composition are consistent with the intended use;
(ii) Mechanical performance (fatigue) testing under simulated physiological conditions to demonstrate maximum load (endurance limit) when the device is subjected to compressive and shear loads;
(iii) Corrosion testing under simulated physiological conditions to demonstrate corrosion potential of each metal or alloy, couple potential for an assembled dissimilar metal implant system, and corrosion rate for an assembled dissimilar metal implant system;
(iv) The device must be demonstrated to be biocompatible;
(v) Sterility testing must demonstrate the sterility of the device;
(vi) Performance testing to evaluate the compatibility of the device in a magnetic resonance (MR) environment;
(vii) Labeling must include a clear description of the technological features, how the device should be used in patients, detailed surgical protocol and restoration procedures, relevant precautions and warnings based on the clinical use of the device, and qualifications and training requirements for device users including technicians and clinicians;
(viii) Patient labeling must contain a description of how the device works, how the device is placed, how the patient needs to care for the implant, possible adverse events and how to report any complications; and
(ix) Documented clinical experience must demonstrate safe and effective use and capture any adverse events observed during clinical use.
{0}------------------------------------------------
Image /page/0/Picture/1 description: The image shows two logos side by side. The first logo is for Implant Direct, with the words "Implant Direct" in bold black letters. The second logo contains the text "Legacy3 6mmL Implants" in black letters.
# 510(K) Summary (21CFR 807.92(c))
- 1. Submitter's Information: Company Name: Implant Direct Sybron Manufacturing LLC 27030 Malibu Hills Rd., Calabasas Hills, CA USA 91301 Address: Telephone: 818-444-3300 818-444-3406 Fax: 3001617766 Registration No .: Ines Aravena Contact: May 15, 2013 Date Prepared:
- 2. Device Name and Classification: Device Trade Name: Legacy3 6mm Length Implants Classification Names: Implant, Endosseous, Root-Form Endosseous Dental Implant Common Names: Requlation Number: 872.3640 Product Codes: DZE Regulatory Class: Il
AUG 2 2 2013
### 3. Predicate Device(s):
Spectra Dental Implant System (K061319) Implant Direct Legacy Dental Implants with HA Coating (K073033) Implant Direct Spectra-System Implants 2008 (K090234) Implant Direct SwissPlant Implants (K081396) Bicon Implants with a 2.5mm Internal Connection (K092035) The Bicon 5.0 X 5.0mm and 6.0 X 5.0mm Dental Implant (K073368) ITI Dental Implant System (K030007)
### 4. Device Description:
The Legacy3 6mm length implants consists of two-piece implants for one-stage or two-stage surgical procedures. These implants are intended for use in partially and fully edentulous upper and lower jaws in support of single or multiple-unit restorations and terminal or intermediate abutment support for fixed bridgework. Implants can be indicated for immediate loading when good primary stability has been achieved and with appropriate occlusal loading.
The Legacy3 6mm length implants have a taper body to facilitate insertion in an undersized socket and gradual expansion of bone to increase initial stability. The body has double-lead buttress threads and quadruple-lead threads in the coronal
{1}------------------------------------------------
# K131097
Image /page/1/Picture/1 description: The image shows the logo for Implant Direct. The logo is black and white and features the company name in a bold, sans-serif font. To the right of the logo, the text "Legacy3 6mmL Implants" is visible. The text is smaller than the logo and is also in black and white.
510(K) Submission
region. The body offers two surface options: Soluble Blasted Media (SBM) texture throughout the entire length or SBM at the coronal section plus HAcoated the rest of the body length. The internal connection consists of leading bevel, a hex and a 1-72UNF thread to engage the mating components.
The Legacy3, 6mm length implants are a line extension to the previously cleared Legacy implants (K090234) having identical prosthetic interface compatibility. The addition is not due to recall, customer complaint, corrective action, or labeling and it does not affect its intended use. The addition provides a shorter version of the predicate implant in order to allow for a restoration option in areas of the mouth where an 8mm implant will not work.
The shorter version required minor changes to the outer body design taper and threads depth to allow for adequate thread engagement when using existing surgical protocol and have a surface area that is equal or greater than the predicate devices. The shorter 6mm length implants are equivalent to the existing SwishPlant 6mm implants (K081396) with clinically proven safety and efficacy.
The Legacy3 6mmL implants offer six body diameters (3.7, 4.2, and 4.7, 5.2, 5.7 and 7.0 mm) in 6mm length with the platform diameter of 3.5, 4.5 and 5.7mm. The Legacy3 6mmL implants are available with two surface coatings: SBM Blast and HA Coating. The Legacy3 6mm implants are surgically and functionally compatible with the previously cleared prosthetic components (K060063, K081101, K090234 and K061319), and currently marketed laboratory components and surgical armamentaria.
### 5. Intended Use:
Legacy3 6mm Length implants consist of two-piece implants for one-stage or two-stage surgical procedures. These implants are intended for use in partially and fully edentulous upper and lower jaws in support of single or multiple-unit restorations and terminal or intermediate abutment support for fixed bridgework. Implants can be indicated for immediate loading when good primary stability has been achieved and with appropriate occlusal loading.
### Device Comparison (Technological Characteristics): 6.
This submission is comprised of devices whose physical dimensions, material composition, indications for use and methods of manufacture were previously cleared and have the same principles of operation as the cited predicate devices. The following Tables summarize the predicate device comparison analyses with the devices within the Legacy3 6mmL Implants. The subject device and the predicate devices have the same intended, the same technological characteristics, implant/abutment interface, similar material and surface treatment.
{2}------------------------------------------------
Image /page/2/Picture/1 description: The image contains two distinct text blocks. The first block features the logo of "Implant Direct," accompanied by smaller text underneath. The second block reads "Legacy3 6mmL Implants", indicating a specific product or model. The text is clear and legible, suggesting a label or product description.
The table below compares the Legacy3 6mm Length Implants with currently marketed products. The comparison analysis consisted of the products' technological characteristics and intended use to support the substantial equivalency to their corresponding predicate devices.
### Device Comparison Table: Legacy3 6mmL Dental Implants
| Characteristics | Proposed:<br>Legacy3 6mm | Own Predicate<br>Device: Legacy<br>8mm<br>(K073033,<br>K090234) | Own Reference<br>Device:<br>SwissPlant 6mm<br>(K081396) | Predicate<br>Device:<br>Bicon<br>Implants<br>(K073368<br>and<br>K092035) | Predicate<br>Device:<br>Straumann<br>(K030007) | Substantial<br>Equivalence |
|----------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------|
| Part<br>Numbers | 853706, 854206,<br>854706, 855206,<br>855706, 857008,<br>863706, 864206,<br>864706, 865206,<br>865706, 867008 | 853208, 853708,<br>854208, 854708,<br>855208, 855708,<br>857008 | 904106, 904806,<br>904806W,<br>905706 | 260-340-255 | 043.051S | √ |
| Intended<br>Use | The Legacy<br>Dental Implant is<br>a dental implant<br>fixture that is a<br>part of a two-<br>piece implant<br>system. The<br>Legacy implants<br>are intended for<br>use in the<br>mandible and<br>maxilla, in<br>support of single<br>or multiple-unit<br>cement or screw<br>receiving fixed<br>restorations and<br>for retention and<br>support of<br>overdentures.<br>The implants are<br>intended for<br>immediate<br>placement and | The Legacy<br>Dental Implant is<br>a dental implant<br>fixture that is a<br>part of a two-<br>piece implant<br>system. The<br>Legacy implants<br>are intended for<br>use in the<br>mandible and<br>maxilla, in<br>support of single<br>or multiple-unit<br>cement or screw<br>receiving fixed<br>restorations and<br>for retention and<br>support of<br>overdentures.<br>The implants are<br>intended for<br>immediate<br>placement and | The SwissPlant<br>Dental Implant<br>system consists<br>of two-piece<br>implants for one<br>or two-stage<br>surgical<br>procedures that<br>are intended for<br>use in partially or<br>fully edentulous<br>mandibles and<br>maxillae, in<br>support of single<br>or multiple-unit<br>restorations<br>including: cement<br>retained, screw<br>retained or<br>overdenture<br>restorations and<br>in terminal or<br>immediate<br>abutment support | Intended for<br>surgical<br>implantation<br>in edentulous<br>mandibles or<br>maxillae for<br>attachment of<br>complete<br>denture<br>prostheses,<br>or as a<br>terminal or<br>intermediary<br>attachment<br>for fixed or<br>removable<br>bridgework,<br>or as a<br>freestanding<br>single tooth<br>replacement | Intended for<br>immediate<br>placement<br>and function<br>on single-<br>tooth and/or<br>multiple tooth<br>applications<br>when good<br>primary<br>stability is<br>achieved and<br>with<br>appropriate<br>occlusal<br>loading, to<br>restore<br>chewing<br>function.<br>Multiple tooth<br>applications<br>may be<br>rigidly<br>splinted. In | √ |
| | | | | | 510(K) Submission | |
| | function for<br>support of single<br>tooth and/or<br>multiple tooth<br>restorations,<br>recognizing bone<br>stability and<br>appropriate<br>occlusal load<br>requirements. | function for<br>support of single<br>tooth and/or<br>multiple tooth<br>restorations,<br>recognizing bone<br>stability and<br>appropriate<br>occlusal load<br>requirements. | for fixed<br>bridgework. The<br>SwissPlant dental<br>implants are<br>intended for<br>immediate<br>placement and<br>function on single<br>tooth and/or<br>multiple tooth<br>applications<br>recognizing initial<br>implant stability<br>and appropriate<br>occlusal loading,<br>to restore normal<br>masticatory<br>function. | | case of<br>edentulous<br>patients 4 or<br>more<br>implants<br>must be used | |
| Indication | Immediate Load | Immediate Load | Immediate Load | Unknown | Unknown | √ |
| General<br>Design | Threaded, root<br>form implant | Threaded, root<br>form implant | Threaded, root<br>form implant | Groove type<br>implant | Threaded,<br>root form<br>implant | √ |
| Placement<br>Method | Dual or single-<br>stage surgery | Dual or single-<br>stage surgery | Dual or single-<br>stage surgery | Two or single<br>stage surgery | Single stage<br>surgery | √ |
| Material | Titanium Alloy (Ti<br>6AL-4V ELI) | Titanium Alloy (Ti<br>6AL-4V ELI) | Titanium Alloy (Ti<br>6AL-4V ELI) | Commercially<br>pure Titanium | Commercially<br>pure Titanium | √ |
| Implant<br>Body | Threaded body<br>without gingival<br>collar | Threaded body<br>without gingival<br>collar | Threaded body<br>with gingival<br>collar | Grooved<br>body without<br>gingival collar | Threaded<br>body with<br>gingival collar | √ |
| Body<br>Diameter | 3.7, 4.2, 4.7, 5.2,<br>5.7, 7.0mm | 3.2, 3.7, 4.2, 4.7,<br>5.2, 5.7, 7.0mm | 4.1, 4.8, 5.7mm | 4.0, 5.0,<br>6.0mm | 4.1, 4.8mm | √ |
| Length | 6mm | 8mm | 6mm | 5mm | 6mm | √ |
| Platform<br>Diameter | 3.5, 4.5, 5.7mmD<br>853706, 863706,<br>854206 & 864206<br>- Ø3.5 platform<br>854706, 864706,<br>855206 & 865206<br>- Ø4.5 platform<br>855706, 865706,<br>857006 & 867006<br>- Ø5.7 platform | 3.0,3.5, 4.5,<br>5.7mmD<br>853208 =<br>Ø3.0 platform<br>853708 & 854208<br>- Ø3.5 platform<br>854708 & 855208<br>- Ø4.5 platform<br>855708 & 857008<br>- Ø5.7 platform | 4.8, 6.5mmD<br>904106 & 904806<br>-Ø4.8mm platform<br>904806W &<br>905706<br>-Ø6.5mm platform | 2.5 - 3.0mm | 4.8 and<br>6.5mm | √ |
| Implant<br>Surface | SBM | SBM | SBM | Integra-Ti<br>and Integra-CP | SLA and<br>SLActive | √ |
| level | Roughened | Roughened | Roughened or<br>Dual Roughened | Unknown | Unknown | |
| Surface<br>Roughness | SBM =1.5-2.3μm | SBM =1.5-2.3μm | SBM =1.5-2.3μm | Unknown | Unknown | √ |
| Packaging | Inner sleeve to<br>suspend the<br>implant/fixture-<br>mount assembly<br>inside an outer<br>vial sealed with a<br>cap. Packaging<br>also includes<br>surgical cover<br>screw, extender<br>and temporary<br>coping | Inner sleeve to<br>suspend the<br>implant/fixture-<br>mount assembly<br>inside an outer<br>vial sealed with a<br>cap. Packaging<br>also includes<br>surgical cover<br>screw, extender<br>and temporary<br>coping | Inner sleeve to<br>suspend the<br>implant/fixture-<br>mount assembly<br>inside an outer<br>vial sealed with a<br>cap. Packaging<br>also includes<br>surgical cover<br>screw, extender<br>and temporary<br>coping | Implants are<br>packaged in<br>a sealed<br>plastic<br>container<br>with a Tyvek<br>type sealed<br>barrier and<br>with a plastic<br>carrier. | Double vial<br>system.<br>Inner sleeve<br>to suspend<br>the implant<br>inside an<br>outer vial<br>sealed with a<br>cap.<br>Packaging<br>also includes<br>surgical<br>cover screw | √ |
| Sterilizatio<br>n | Gamma<br>Irradiation | Gamma<br>Irradiation | Gamma<br>Irradiation | Unknown | Unknown | √ |
| 510(k)<br>Number | | K073033<br>K090234 | K081396 | K073368<br>K092035 | K030007 | √ |
{3}------------------------------------------------
K131097
Image /page/3/Picture/1 description: The image contains two distinct sections. The left side features the logo for "Implant Direct", with the text arranged in a specific font and layout. The right side of the image contains the text "Legacy3 6mmL Implants", which appears to be a product description or label.
{4}------------------------------------------------
The Legacy3 6mmL implants were shown to be substantially equivalent to the predicate devices: Legacy 8mmL (K073033 and K090234), SwissPlant 6mmL Implants (K081396), Bicon Implants (K073368 and K092035), and Straumann Implants (K030007).
### Non-clinical Performance Testing: 7.
The devices in this submission have mechanical safety (strength) equivalent to the predicate devices. Laboratory testing was conducted for the worst-case devices following FDA "Class II Special Control Guidance Document: Root-form Endosseous Dental Implants and Endosseous Dental Abutments" and ISO 14801 in static compression bending and fatigue, as well as implant driving torque and abutment/screw torque to failure tests. The components have shown to exhibit equivalent mechanical strength as the predicate devices and the implant/abutment combinations were able to withstand loads that were higher than the functional masticatory loads.
In addition, comparative surface area analysis was performed to demonstrate substantial equivalence by creating 3D models of the implants and obtaining the total external osseointegration surface area using three dimensional CAD measurement function. Furthermore, comparative pull-out testing was conducted
{5}------------------------------------------------
| | Concession Company of Children |
|-------|--------------------------------|
| : Com | Legacy3 6mmL Implants |
to demonstrate substantial equivalence by inserting the implants into simulated bone taking into account 3mm of potential bone loss.
Lastly, sterilization Validation was carried out in accordance with ISO 11137-2 and AAMI TIR-33 for gamma radiation.
#### 8. Clinical Performance Testing
No clinical testing was performed. The clinical evaluation was used to support the decision of safety and effectiveness.
#### 9. Conclusion:
The information submitted in this 510(k) for the Legacy3 6mmL Implants have shown that the devices are substantial equivalent to the device systems identified as predicates and it is considered that the new devices are as safe and effective for its indication for use, compatible and performs as well the predicate device.
{6}------------------------------------------------
DEPARTMENT OF HEALTH & HUMAN SERVICES
Image /page/6/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized depiction of an eagle or bird with outstretched wings, rendered in black lines. The bird is enclosed within a circle, and the text "DEPARTMENT OF HEALTH & HUMAN SERVICES. USA" is arranged around the upper portion of the circle. The text is also in black and appears to be in all capital letters.
August 22, 2013
Implant Direct Sybron Manufacturing LLC Ms. Ines Aravena Senior Director of Product Design and Regulatory Affairs 27030 Malibu Hills Road CALABASAS HILLS CA 91301
K131097 Re:
Trade/Device Name: Legacy3 6mm Length Implants Regulation Number: 21 CFR 872.3640 Regulation Name: Endosseous Dental Implant Regulatory Class: II Product Code: DZE Dated: July 23, 2013 Received: July 24, 2013
Dear Ms. Aravena:
We have reviewed your Section 510(k) premarket notification of intent to referenced above and have determined the device is substantially equivale for use stated in the enclosure) to legally marketed predicate devices mark commerce prior to May 28, 1976, the enactment date of the Medical Device devices that have been reclassified in accordance with the provisions of the and Cosmetic Act (Act) that do not require approval of a premarket appro You may, therefore, market the device, subject to the general controls pro general controls provisions of the Act include requirements for annual reg devices, good manufacturing practice, labeling, and prohibitions against n International Places not ... CDD11 dage not sucluate information ralatad to
{7}------------------------------------------------
Please be advised that FDA's issuance of a substantial equivalence determ that FDA has made a determination that your device complies with other r or any Federal statutes and regulations administered by other Federal agen comply with all the Act's requirements, including, but not limited to: regis CFR Part 807); labeling (21 CFR Part 801); medical device reporting (rep device-related adverse events) (21 CFR 803); good manufacturing practice forth in the quality systems (QS) regulation (21 CFR Part 820); and if app product radiation control provisions (Sections 531-542 of the Act); 21 CFI
If you desire specific advice for your device on our labeling regulation (21 contact the Division of Small Manufacturers, International and Consumer free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.ht the regulation entitled. "Misbranding by reference to premarket notificatio 807.97). For questions regarding the reporting of adverse events under the CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm f of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under t Division of Small Manufacturers, International and Consumer Assistance (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.ht
Sincerely yours,
Image /page/7/Picture/5 description: The image shows the name "Mary S. Ru". The text is in a bold, sans-serif font. The letters are black, and the background is white. The letters are slightly distorted, especially the "S" and "Ru".
Y II VIA
{8}------------------------------------------------
Image /page/8/Picture/0 description: The image contains two logos. The first logo is for "Implant Direct Sybron Dental Specialties". The second logo is for "Legacy3 6mmL Implants".
## Indications for Use
510(k) Number (if known): K131097
Device Name: Legacy3 6mm Length_Implants
Indications for Use:
Legacy3 6mm Length consists of two-picce implants for one-stage on two-stage surgical Legacy3 bmm Lengin consists of Norpheee napitally and fully edentulous upper
procedures. These implants are intended for use in partially and fully as any procedures. These miffams are miended this are restorations and serminal or intermediate abutment support for fixed bridgework. Implants can be indicated for intermediate abutifiem support for fixed bridgeworks aspirities and with appropriate occlusal loading.
Prescription Use _ メ (Part 21 CFR 801 Subpart D) AND/OR
Over-The-Counter Use (21 CFR 801 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE OF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Andrew I. Steen -S-2013.08.21 08:05:01 -04'00'
Division Sign-Off) ·ivision of Anesthesiology, General Hospital rection Control, Dental Devices
Page | of |
510(k) Number: 长13(0分7
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.