K123261 · Euroimmun US · LKO · Jun 12, 2013 · Immunology
Device Facts
Record ID
K123261
Device Name
EUROIMMUN ANTI-NRNP/SM ELISA (IGG)
Applicant
Euroimmun US
Product Code
LKO · Immunology
Decision Date
Jun 12, 2013
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 866.5100
Device Class
Class 2
Attributes
Real-World Evidence
Real-World Evidence
Submission
Device
Sponsor
RWD Sources
RWE Use Summary
Key Tags
K123261 · Jun 12, 2013
EUROIMMUN ANTI-NRNP/SM ELISA (IGG)
Euroimmun US
Clinically characterized patient samples from clinical cohorts
Retrospective clinical samples were used to determine the clinical sensitivity and specificity of the EUROIMMUN ELISA test kits across various autoimmune disease groups.
Retrospective analysis of clinically characterized samples
Patients with autoimmune diseases (e.g., MCTD, SLE, Sjögren's, Myositis, Systemic Sclerosis) and control groups; Sample Size: 1046 (Anti-nRNP/Sm), 1036 (Anti-Sm), 1026 (Anti-SS-A), 1026 (Anti-SS-B), 909 (Anti-Scl-70), 877 (Anti-Centromeres), 876 (Anti-Jo-1), 876 (Anti-ribosomal P); Number of Sites: Multiple sites
Not applicable for this study
Clinical sensitivity and specificity
Indications for Use
The EUROIMMUN Anti-nRNP/Sm ELISA (IgG) test kit is intended for the qualitative determination of IgG class autoantibodies against nRNP/Sm in human serum and plasma (EDTA, Li-heparin, Citrate). It is used as an aid in the diagnosis of mixed connective tissue diseases and systemic lupus erythematosus, in conjunction with other laboratory and clinical findings. The EUROIMMUN Anti-Sm ELISA (IgG) test kit is intended for the qualitative determination of IgG class autoantibodies against Sm in human serum and plasma (EDTA, Li-heparin, Citrate). It is used as an aid in the diagnosis of systemic lupus erythematosus, in conjunction with other laboratory and clinical findings. The EUROIMMUN Anti-SS-A ELISA (IgG) test kit is intended for the qualitative determination of IgG class autoantibodies against SS-A in human serum and plasma (EDTA, Li-heparin, Citrate). It is used as an aid in the diagnosis of Sjögren’s syndrome and systemic lupus erythematosus, in conjunction with other laboratory and clinical findings. The EUROIMMUN Anti-SS-B ELISA (IgG) test kit is intended for the qualitative determination of IgG class autoantibodies against SS-B in human serum and plasma (EDTA, Li-heparin, Citrate). It is used as an aid in the diagnosis of Sjögren’s syndrome and systemic lupus erythematosus, in conjunction with other laboratory and clinical findings. The EUROIMMUN Anti-Scl-70 ELISA (IgG) test kit is intended for the qualitative determination of IgG class autoantibodies against Scl-70 in human serum and plasma (EDTA, Li-heparin, Citrate). It is used as an aid in the diagnosis of progressive systemic sclerosis, in conjunction with other laboratory and clinical findings. The EUROIMMUN Anti-Centromeres ELISA (IgG) test kit is intended for the qualitative determination of IgG class autoantibodies against Centromeres in human serum and plasma (EDTA, Li-heparin, Citrate). It is used as an aid in the diagnosis of limited form of progressive systemic sclerosis (CREST syndrome), in conjunction with other laboratory and clinical findings. The EUROIMMUN Anti-Jo-1 ELISA (IgG) test kit is intended for the qualitative determination of IgG class autoantibodies against Jo-1 in human serum and plasma (EDTA, Li-heparin, Citrate). It is used as an aid in the diagnosis of polymyositis and dermatomyositis, in conjunction with other laboratory and clinical findings. The EUROIMMUN Anti-ribosomal P-proteins ELISA (IgG) test kit is intended for the qualitative determination of IgG class autoantibodies against ribosomal P-proteins in human serum and plasma (EDTA, Li-heparin, Citrate). It is used as an aid in the diagnosis of systemic lupus erythematosus, in conjunction with other laboratory and clinical findings.
Device Story
The EUROIMMUN ELISA test kits are qualitative enzyme immunoassays for detecting specific IgG autoantibodies in human serum or plasma. The device consists of a microwell plate coated with specific antigens (nRNP/Sm, Sm, SS-A, SS-B, Scl-70, Centromeres, Jo-1, or Ribosomal P-proteins). Patient samples are diluted and incubated in the wells; unbound antibodies are washed away. Peroxidase-labeled anti-human IgG conjugate is added, followed by a second incubation and wash. TMB substrate is added, producing a color change proportional to the antibody concentration, which is stopped with sulfuric acid. The plate is read at 450nm using a microwell plate reader. Results are calculated as a ratio against a calibrator. The device is used in clinical laboratories by trained personnel to aid in the diagnosis of various autoimmune conditions. The two-step assay design minimizes matrix effects and interference from binding proteins. Healthcare providers use the qualitative results in conjunction with clinical findings to support diagnostic decisions, potentially improving patient management for connective tissue diseases.
Clinical Evidence
Clinical performance was evaluated using large cohorts of clinically characterized samples (e.g., 1046 for nRNP/Sm, 1036 for Sm, 1026 for SS-A/SS-B, 909 for Scl-70, 877 for Centromeres, 876 for Jo-1, 876 for Ribosomal P). Sensitivity and specificity were calculated against clinical diagnoses. Specificity ranged from 94.8% to 99.8% across the panels. Method comparison studies against predicate devices showed high overall agreement (95.9% to 100.0%).
Technological Characteristics
ELISA platform using 96-well microtiter plates. Antigen-coated wells; peroxidase-labeled anti-human IgG conjugate; TMB substrate; 0.5 M sulfuric acid stop solution. Manual or automated processing; requires 450nm plate reader. Qualitative result reporting via ratio. Sample dilution 1:201. Compatible with serum, EDTA, Li-heparin, and Citrate plasma.
Indications for Use
Indicated for qualitative detection of IgG autoantibodies in human serum/plasma to aid diagnosis of mixed connective tissue disease, systemic lupus erythematosus, Sjögren’s syndrome, progressive systemic sclerosis, CREST syndrome, polymyositis, and dermatomyositis.
Regulatory Classification
Identification
An antinuclear antibody immunological test system is a device that consists of the reagents used to measure by immunochemical techniques the autoimmune antibodies in serum, other body fluids, and tissues that react with cellular nuclear constituents (molecules present in the nucleus of a cell, such as ribonucleic acid, deoxyribonucleic acid, or nuclear proteins). The measurements aid in the diagnosis of systemic lupus erythematosus (a multisystem autoimmune disease in which antibodies attack the victim's own tissues), hepatitis (a liver disease), rheumatoid arthritis, Sjögren's syndrome (arthritis with inflammation of the eye, eyelid, and salivary glands), and systemic sclerosis (chronic hardening and shrinking of many body tissues).
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.