MOTEX POLYISOPRENE POWDER-FREE SURGICAL GLOVES MODEL # 6412(6432) AND # 6512(6532)
K123126 · Shanghai Motex Healthcare Co., Ltd. · KGO · Jun 4, 2014 · General, Plastic Surgery
Device Facts
Record ID
K123126
Device Name
MOTEX POLYISOPRENE POWDER-FREE SURGICAL GLOVES MODEL # 6412(6432) AND # 6512(6532)
Applicant
Shanghai Motex Healthcare Co., Ltd.
Product Code
KGO · General, Plastic Surgery
Decision Date
Jun 4, 2014
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 878.4460
Device Class
Class 1
Indications for Use
MOTEX Polyisoprene Powder-Free Sterile Surgical Gloves are powder-free surgeon's glove made of synthetic rubber intended to be worn by operating room personnel to protect a surgical wound from contamination. The lubricating or dusting powder used in the glove is excluded.
Device Story
Sterile, single-use surgical gloves made of synthetic polyisoprene rubber; intended for use by operating room personnel to protect surgical wounds from contamination. Available in two thicknesses (Model 6412 thin, 6512 thick) and two colors (Nature, Blue). Features include curved fingers, textured surface, and beaded cuff. Sterilized via radiation. Protects patient and user from cross-contamination; non-latex material prevents latex-related allergic reactions.
Clinical Evidence
Bench testing only. Compliance with ASTM D3577-09 (dimensions, physical properties, freedom from holes), ASTM D6124-06 (residual powder), ASTM D5151-06 (water leak), and ASTM D5712-10 (protein content). Biocompatibility testing per ISO 10993-10 and ISO 10993-12 confirmed non-irritant and non-sensitizing properties. Sterilization validated per ISO 11137-1 and ISO 11137-2.
Technological Characteristics
Material: Synthetic polyisoprene. Form factor: Curved finger, textured surface, beaded cuff. Sterilization: Radiation (ISO 11137). Standards: ASTM D3577-09, ASTM D6124-06, ASTM D5151-06, ASTM D5712-10. Biocompatibility: ISO 10993. Single-use, non-latex.
Indications for Use
Indicated for operating room personnel to protect surgical wounds from contamination. For use as a sterile, powder-free, synthetic rubber surgeon's glove.
Regulatory Classification
Identification
A non-powdered surgeon's glove is a device intended to be worn on the hands of operating room personnel to protect a surgical wound from contamination. A non-powdered surgeon's glove does not incorporate powder for purposes other than manufacturing. The final finished glove includes only residual powder from manufacturing.
{0}------------------------------------------------
## SHANGHAI MOTEX HEATHCARE CO., LTD.
No.369, Jiasong Zhong Road, Huaxin, Qingpu, Shanghai, 201708, China Telephone: 86-21-5979 9888 Fax: 86-21-23010718
## II. 510(K) Summary of Safety and Effectiveness (Per 21 CFR 807.92)
## JUN 0 4 2014
### 2.1. General Information Establishment
- Manufacturer: Shanghai Motex Healthcare Co., Ltd.
- 특 Address: No.369, Jiasong Zhong Road, Huaxin, Qingpu, Shanghai, 201708, China
K123126
- 그 Owner Number: 9041164 Registration Number: 9615978
- 를 Contact Person: Dr. Jen, Ke-Min E-mail: ceirs.jen@msa.hinet.net Tel: +886-3-5208829 : Fax: +886-3-5209783
- 그 May 23, 2014 . Date Prepared:
Proprietary Name:
### Subject Device:
- MOTEX Polyisoprene Powder-free Sterile Surgical Gloves, Model 6412 Nature MOTEX Polyisoprene Powder-free Sterile Surgical Gloves, Model 6412 Blue MOTEX Polyisoprene Powder-free Sterile Surgical Gloves, Model 6512 Nature MOTEX Polyisoprene Powder-free Sterile Surgical Gloves, Model 6512 Blue
| • Common Name: | Surgeon's glove |
|----------------|-----------------|
|----------------|-----------------|
- . Classification Name: Surgeon's Gloves
- Product Code: KGO, Class I
- Regulation Number: 878.4460
- Predicate device:
- . Esteem SMT Polyisoprene Powder-Free Surgical Sterile Gloves (K093300)
### 2.2. Safety and Effectiveness Information
- Predicate Device:
Claim of Substantial Equivalence (SE) is made to Esteem SMT Polyisoprene Powder-Free Surgical Sterile Gloves (K093300)
- Device Description:
Motex Powder-free Polyisoprene Surgical Sterile Gloves, Model # 6412 Nature, 6412_Blue; 6512_Nature, 6512_Blue are made of synthetic rubber. The sterile gloves are sterilized by the radiation method. 6412 Nature, 6412 Blue are of thin gloves. 6512 Nature, 6512 Blue are of thick gloves. They are processed by special treatment with no protein, and intended to be used in surgery to prevent the cross contamination between patients and users.
{1}------------------------------------------------
No.369, Jiasong Zhong Road, Huaxin, Qingpu, Shanghai, 201708, China Telephone: +86-21-5979 9888 Fax: +86-21-23010718
### Motex Polyisoprene Powder-free Surgical Gloves variant models
| Model | Size | Product Description | | | | | Size | |
|-------|-------------------------------------|---------------------|----------|-------------|---------|-------------|--------------|------------------|
| | | Hand shape | Surface | Beaded cuff | Sterile | Color | Length (min) | Thickness (min) |
| 6412 | 6, 6.5, 7, 7.5, 8, 8.5<br>(Sterile) | Curved Finger | Textured | • | • | Nature Blue | $280\pm6$ mm | $0.13\pm0.03$ mm |
| 6512 | 6, 6.5, 7, 7.5, 8, 8.5<br>(Sterile) | Curved Finger | Textured | • | • | Nature Blue | $280\pm6$ mm | $0.15\pm0.03$ mm |
#### ● Indications for Use:
MOTEX Polyisoprene Powder-Free Sterile Surgical Gloves are powder-free surgeon's glove made of synthetic rubber intended to be worn by operating room personnel to protect a surgical wound from contamination. The lubricating or dusting powder used in the glove is excluded.
#### . Device Characteristics:
a. Single use only.
b. Not made with natural rubber latex.
#### ● Powder Residual:
Surgeon's gloves meet powder level requirements for Powder-free" designation per ASTM D6124-06 (Reaffirmation 2011), Standard test method for residual powder on medical gloves.
The results generated values will be below 2mg of residual powder per glove.
#### ● Biocompatibility Test Reports:
There are complied with the biological evaluation and the results of these studies show that the MOTEX Polyisoprene Powder-free Sterile Surgical Glove safety for its intended use, including:
- � Systemic Intravenous Injection
- Systemic Intraperitoneal Injection
- Skin Sensitization Test (Maximization test), Sesame oil extract;
- . Sensitization Test (Maximization test), Sodium Chloride extract;
- Skin Irritation Test, Sesame oil extract;
- Skin Irritation Test, Sodium Chloride extract;
{2}------------------------------------------------
No.369, Jiasong Zhong Road, Huaxin, Qingpu, Shanghai, 201708, China Telephone: +86-21-5979 9888 Fax: +86-21-23010718
- Clinical Data:
Not applicable.
#### Comparison between the subject devices and the predicate device ●
| Feature | Predicate device | Subject device |
|-------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Proprietary name | Esteem SMT Polyisoprene<br>Powder-Free Surgical Sterile<br>Gloves | Motex Powder-free Polyisoprene<br>Surgical Gloves |
| 510(k) number | K093300 | K123126 |
| Model | SMT | 6412 (nature, blue)<br>6512 (nature, blue) |
| Indications For Use | Powder-Free Polyisoprene Surgical<br>Gloves are sterile disposable<br>devices made of imported synthetic<br>rubber intended to be worn by<br>operating room personnel to<br>protect a surgical wound from<br>contamination in the environments<br>within hospitals and other<br>healthcare facilities. | MOTEX Polyisoprene Powder-Free<br>Sterile Surgical Gloves are<br>powder-free surgeon's glove made of<br>synthetic rubber intended to be worn<br>by operating room personnel to<br>protect a surgical wound from<br>contamination. The lubricating or<br>dusting powder used in the glove is<br>excluded. |
| Prescription/OTC<br>Device | Over-the-Counter Use | Over-the-Counter Use |
| Product code | KGO | KGO |
| Classification | Class I | Class I |
| Regulation number | 878.4460 | 878.4460 |
| Manufacturing<br>material | Synthetic Polyisoprene | Synthetic Polyisoprene |
| Specifications | | |
| Size | N/A | Size: 6, 6.5, 7, 7.5, 8, 8.5 |
| Length (mm) | N/A | $280\pm6$ |
| Width (mm) | N/A | size 6--77, size 6.5--84,<br>size 7--91, size 7.5--98,<br>size 8--102, size 8.5-108 |
| Thickness (finger,<br>palm, cuff) (mm) | N/A | (6412)—<br>$0.13\pm0.03$ ,<br>$0.13\pm0.03$<br>(6512)—<br>$0.15\pm0.03$ ,<br>$0.15\pm0.03$ |
| Tensile strength<br>(before and after<br>aging), | N/A | Before aging: 24 Mpa<br>After aging: 23 Mpa |
| ultimate elongation<br>(%) (before and after<br>aging) | N/A | Before aging : 929%<br>After aging : 879% |
| Test for Pinhole,<br>Dimensions, and<br>Physical properties | Meets ASTM D3577-09 | Meets ASTM D3577-09 |
| Residual powder<br>testing | Meets ASTM D 6124-06<br>Residual powder < 2mg | Meets ASTM D6124-06<br>(Reaffirmation 2011)<br>Residual powder < 2mg |
| Water leak<br>testing(AQL) | Meets ASTM D 5151-06<br>(AQL=1.5) | Meets ASTM D 5151-06<br>(Reapproved 2011)<br>(AQL=1.5) |
| Water extractable<br>protein testing | Meets ASTM D 5712-10<br>No protein content | Meets ASTM D 5712-10<br>No protein content |
| Biocompatibility | non irritant<br>non sensitizing | non irritant<br>non sensitizing |
| Sterilization Validation | Pass ISO11137-1<br>ISO11137-2<br>Sterilization Assurance Number:<br>1 x 10-6 | Pass ISO11137-1:2006<br>(Amendment 1:2013)<br>ISO11137-2:2013<br>Sterilization Assurance Number:<br>1 x 10-6 |
## Comparison Table
K 123 126
{3}------------------------------------------------
## SHANGHAI MOTEX HEALTHCARE CO., LTD.
No.369, Jiasong Zhong Road, Huaxin, Qingpu, Shanghai, 201708, China Telephone: +86-21-5979 9888 Fax: +86-21-23010718
#### ● Discussion of the similarities
The same performance data of the Motex Powder-free Polyisoprene Sterile Surgical Gloves compared to the predicate device are summarized below.
| Characteristics | Standard |
|-----------------------------------|-------------------------------------------------------------------------|
| Dimensions | meets ASTM D 3577-09, |
| Physical Properties | meets ASTM D 3577-09, |
| Freedom from Holes | meets ASTM D 3577-09, |
| Residual powder testing | meets ASTM D 6124-06 (Reaffirmation 2011) |
| Water leak testing | meets ASTM D 5151-06 (Reapproved 2011) |
| Water extractable protein testing | meets ASTM D 5712-10 |
| Biocompatibility | non irritant & non- sensitizing<br>ISO10993-10:2010<br>ISO10993-12:2012 |
| Sterilization Validation | Pass ISO11137-1:2006 (Amendment 1:2013)<br>ISO11137-2:2013 |
K 123 126
4
{4}------------------------------------------------
The subject device and the predicate device have the similar indications for use, the same material composition with Polyisoprene, the same technological characteristics, and the same biocompatibility and sterilization validation testing. There are no safety or effectiveness aspects raising.
#### ● Discussion of the differences
The minor differences between them are thickness and size. Both of them meet ASTM D 3577-09, ASTM D 6124-06 (Reaffirmation 2011), ASTM D 5151-06 (Reapproved 2011), ASTM D 5712-10, and biocompatibility testing. The safety or effectiveness aspects are not raised.
#### ● Conclusion
The conclusions drawn from the non-clinical tests demonstrate that the device is as safe, as effective, and performs as well as or better than the legally marketed device identified in the submission.
> Dr. Jen, Ke-Min 510(k) correspondent person for Shanghai Motex Healthcare Co., Ltd.
{5}------------------------------------------------
Image /page/5/Picture/1 description: The image is a black and white logo for the U.S. Department of Health & Human Services. The logo features the department's name in a circular arrangement around a stylized symbol. The symbol is a representation of a human figure, with three overlapping profiles suggesting community and connection. The overall design is simple and conveys a sense of unity and service.
Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002
## JUL 18 2014
Shanghai Motex Healthcare Co., Ltd Dr. Jen, Ke-Min No. 369 Jiasong Zhong Road, Huaxin, Qingpu Shanghai 201708 CHINA
Re: K123126
Trade/Device Names: MOTEX Polyisoprene Powder-free Sterile Surgical Gloves, Model 6412 Nature: MOTEX Polyisoprene Powder-free Sterile Surgical Gloves, Model 6412 Blue; MOTEX Polyisoprene Powder-free Sterile Surgical Gloves, Model 6512 Nature: MOTEX Polyisoprene Powder-free Sterile Surgical Gloves, Model 6512 Blue
Regulation Number: 21 CFR 878.4460 Regulation Name: Surgeon's Glove Regulatory Class: I Product Code: KGO Dated: April 26, 2014 Received: May 5, 2014
Dear Dr. Jen, Ke-Min:
This letter corrects our substantially equivalent letter of June 4, 2014.
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
{6}------------------------------------------------
Page 2 - Dr. Jen, Ke-Min
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.
Sincerely yours,
# Mary S. Runner -S
Erin I. Keith, M.S. Director Division of Anesthesiology, General Hospital, Respiratory, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{7}------------------------------------------------
| DEPARTMENT OF HEALTH AND HUMAN SERVICES | Form Approved: OMB No. 0910-0120 |
|-----------------------------------------|-----------------------------------|
| Food and Drug Administration | Expiration Date: January 31, 2017 |
| Indications for Use | See PRA Statement below |
| 510(k) Number (if known) | K123126 |
|--------------------------|---------------------------------------------------------------------------|
| Device Name | MOTEX Polyisoprene Powder-free Sterile Surgical Gloves, Model 6412 Nature |
| | MOTEX Polyisoprene Powder-free Sterile Surgical Gloves, Model 6412 Blue |
| | MOTEX Polyisoprene Powder-free Sterile Surgical Gloves, Model 6512 Nature |
| | MOTEX Polyisoprene Powder-free Sterile Surgical Gloves, Model 6512 Blue |
| Indications for Use (Describe) | MOTEX Polyisoprene Powder-Free Sterile Surgical Gloves are powder-free surgeon's glove made of synthetic rubber intended to be worn by operating room personnel to protect a surgical wound from contamination. The lubricating or dusting powder used in the glove is excluded. |
|--------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
|--------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Type of Use (Select one or both, as applicable) | <label><input type="checkbox"/> Prescription Use (Part 21 CFR 801 Subpart D)</label> <label><input checked="" type="checkbox"/> Over-The-Counter Use (21 CFR 801 Subpart C)</label> |
|-------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
|-------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON A SEPARATE PAGE IF NEEDED.
FOR FDA USE ONLY
| Concurrence of Center for Devices and Radiological Health | Elizabeth F. Claverie |
|-----------------------------------------------------------|-----------------------|
|-----------------------------------------------------------|-----------------------|
This section applies only to requirements of the Paperwork Reduction Act of 1995.
*DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response,
including the time to review instructions, search existing data sources, gather and maintain the data
needed and complete and review the collection of information. Send comments regarding this burden
estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
Department of Health and Human Services
Food and Drug Administration
Office of Chief Information Officer
Paperwork Reduction Act (PRA) Staff
*PRAStaff@fda.hhs.gov*
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of
information unless it displays a currently valid OMB number."
| FORM FDA 3881 (1/14) | Page 1 of 1 | PSC Publishing Services (301) 443-6740 EP. |
|----------------------|-------------|--------------------------------------------|
|----------------------|-------------|--------------------------------------------|
:
.
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.