ZOLL SUREPOWER SINGLE BAY CHARGER

K122839 · ZOLL Medical Corporation · MKJ · Dec 13, 2012 · Cardiovascular

Device Facts

Record IDK122839
Device NameZOLL SUREPOWER SINGLE BAY CHARGER
ApplicantZOLL Medical Corporation
Product CodeMKJ · Cardiovascular
Decision DateDec 13, 2012
DecisionSESE
Submission TypeSpecial
Regulation21 CFR 870.5310
Device ClassClass 3

Indications for Use

The ZOLL SurePower Single Bay Charger is a single-bay unit that can test, recalibrate, and charge a single ZOLL rechargeable defibrillator battery. The charging bay in the SurePower Single Bay Charger is designed to accommodate the following ZOLL rechargeable lithium ion batteries: · SurePower Battery Pack · SurePower II Battery Pack

Device Story

Single-bay charging station for ZOLL rechargeable lithium ion defibrillator batteries; performs testing, recalibration, and charging. Device monitors battery current, temperature, and voltage via serial communication interface using SMBus protocol. Used in clinical settings to maintain battery readiness for defibrillators. Provides status/readiness output to healthcare providers; ensures battery performance for life-saving equipment.

Clinical Evidence

Bench testing only. No clinical data provided. Performance and safety testing demonstrated that the device meets all functional requirements and complies with applicable industry safety standards.

Technological Characteristics

Single-bay charging station; utilizes SMBus serial communication protocol for battery monitoring (current, temperature, voltage). Designed for ZOLL lithium-ion battery packs. Substantially equivalent to K060559.

Indications for Use

Indicated for testing, recalibrating, and charging ZOLL rechargeable lithium ion defibrillator battery packs (SurePower and SurePower II).

Regulatory Classification

Identification

An automated external defibrillator (AED) system consists of an AED and those accessories necessary for the AED to detect and interpret an electrocardiogram and deliver an electrical shock (e.g., battery, pad electrode, adapter, and hardware key for pediatric use). An AED system analyzes the patient's electrocardiogram, interprets the cardiac rhythm, and automatically delivers an electrical shock (fully automated AED), or advises the user to deliver the shock (semi-automated or shock advisory AED) to treat ventricular fibrillation or pulseless ventricular tachycardia.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ ## 510(k) Summary: Submitter's Name and Address: ZOLL Medical Corporation 269 Mill Road Chelmsford, MA 01824-4105 (978) 421-9655 Contact Person: Tanmay B. Shukla (978) 421-9171 Date Summary Prepared: September, 2012 Device: ZOLL SurePower Single Bay Charger Classification: Automatic External Defibrillators: Class III (21 CFR 870,5310) #### Description: The ZOLL SurePower Charger System was cleared by the agency under 510(k) application K060559. This device is a four bay charger system that contains circuitry to monitor the battery's current, temperature, and voltage to ensure safe and effective battery charging and testing. The charging bays in the SurePower Charger Station are designed to accommodate the following ZOLL rechargable lithium ion battery: · SurePower Battery Pack - · SurePower II Battery Pack and the following ZOLL rechargable lead acid batteries: - · Battery Pack PD4410 - · Smart Ready Battery - · Smart Battery - · XL Smart Ready Battery - · XL Smart Battery DEC 1 3 2012 {1}------------------------------------------------ The batteries communicate with the ZOLL SurePower Charger Station over a serial communication interface utilizing the SMBus communications protocol. The SurePower Single Bay Charger is a product line extension of the SurePower (four bay) Charger Station currently in production. The following is a comparison summary of the proposed ZOLL SurePower Single Bay Battery Charger when compared to the ZOLL SurePower Charger: - The SurePower Single Bay Charger is a one bay version of the existing SurePower . Charger. - The SurePower Single Bay Charger charges ZOLL Lithium Ion battery packs only . which includes the SurePower and SurePower II battery packs #### Intended Use: The ZOLL SurePower Single Bay Charger is a single-bay unit that can test, recalibrate, and charge a single ZOLL rechargeable defibrillator battery. The charging bay in the SurePower Single Bay Charger is designed to accommodate the following ZOLL rechargeable lithium ion batteries: - · SurePower Battery Pack - · SurePower II Battery Pack #### Substantial Equivalence: The features and functions of the ZOLL SurePower Single Bay Charger are substantially equivalent to the currently marketed ZOLL SurePower Charger (K060559, cleared for use on 8/17/2006). ### Comparison of Technological Characteristics The technological characteristics of the ZOLL SurePower Single Bay Charger are substantially equivalent to the currently marketed ZOLL SurePower Charger (K060559, cleared for use on 8/17/2006). #### Performance Testing: Extensive performance testing ensures that the ZOLL SurePower Single Bay Charger performs as well as the indicated predicate device and meets all of its functional requirements and performance specifications. Safety testing assures that the device complies with applicable sections of recognized industry and safety standards. #### Conclusion Performance and safety testing of the ZOLL SurePower Single Bay Charger demonstrates that its features and functions are substantially equivalent to those of the indicated commercially distributed predicate device with regard to performance, safety and effectiveness. {2}------------------------------------------------ Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002 DEC 1 3 2012 Zoll Medical Corporation c/o Mr. Tanmay B Shukla 269 Mill Road Chelmsford, MA 01824 # Re: K122839 Trade Device Name: Zoll SurePower Single Bay Charger Regulation Number: 21 CFR 870.5310 Regulation Name: Automated external defibrillator Regulatory Class: Class III (three) Product Code: MKJ Dated: November 13, 2012 Received: November 18, 2012 ### Dear Mr. Shukla: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. {3}------------------------------------------------ # Page 2 – Tanmay B. Shukla Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm. Sincerely yours, ? Bram D. Z Bram D. Zuckerman, M.D. Director Division of Cardiovascular Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {4}------------------------------------------------ # Section 4 - Indications for Use 510(k) Number (if known): K122839 #### ZOLL SurePower Single Bay Charger Device Name: The ZOLL SurePower Single Bay Charger is a single-bay unit that can test, recalibrate, and charge a single ZOLL rechargeable defibrillator battery. The charging bay in the SurePower Single Bay Charger is designed to accommodate the following ZOLL rechargeable lithium ion batteries: · SurePower Battery Pack · SurePower II Battery Pack X Prescription Use (Part 21 CFR 801 Subpart D) AND/OR · Over-The-Counter Use (21 CFR 807 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE OF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Owen P. Faris -S 2012.12.13 16:21:15 -05'00' 16:21:15 -05'00'
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...