K122333 · Aframe Digital, Inc. · DRG · Nov 19, 2012 · Cardiovascular
Device Facts
Record ID
K122333
Device Name
MOBILECARE MONITOR
Applicant
Aframe Digital, Inc.
Product Code
DRG · Cardiovascular
Decision Date
Nov 19, 2012
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 870.2910
Device Class
Class 2
Attributes
Real-World Evidence
Real-World Evidence
Submission
Device
Sponsor
RWD Sources
RWE Use Summary
Key Tags
K122333 · Nov 19, 2012
MOBILECARE MONITOR
Aframe Digital, Inc.
NIH-funded clinical research study (Grant 1R43AG029196-01A1); Participant-reported daily surveys; Device-generated physiological data from COTS wireless measurement devices
The study evaluated the usability, reliability, and participant compliance of the MobileCare Monitor system when integrated with COTS wireless physiological measurement devices in an elderly population.
NIH Phase I Grant Study (1R43AG029196-01A1); Observational/Usability study; Study Period: 2009
Elderly participants
Not applicable for this study
Usability (proximal/distal readings gathered vs. expected), system reliability, data concurrence, and participant compliance.
Indications for Use
The MobileCare Monitor™ remote monitoring system is intended as a support in the care of patients and the elderly in institutional, home, and community care settings. Intended users include the monitored individuals and their caregivers. MobileCare Monitor includes a MyPHD™ personal help device that is intended to monitor patients and the elderly as they go about their daily activities. MyPHD can be affixed to the wrist, clipped to the waist or used in a bandage for attachment at other locations on the monitored individual, as determined by the patient or caregiver. MobileCare monitor provides the MyPHD location information, battery life and indication that it is being worn. MyPHD also includes a help button and a tri-axial accelerometer used to convey the degree of motion created by a wearer's movements to support an assessment of impacts. MobileCare Monitor may also relay physiological data from legally marketed Class I and Class II wireless medical devices (e.g. blood pressure cuff, weight scale, blood glucometer, etc.) to AFrame Digital secure remote servers by means of industry standard networks and public carriers. Physiological data transmitted from these devices are stored and may be retrieved with a secure web browser after the user presents satisfactory security credentials. Users may also request the data to be presented in graphical format. Alerts can be sent when a patient presses a help button on the myPHD or when any data value from MyPHD or relayed device exceeds an upper or lower limit threshold established by a user. These data include impact sensitivity settings and/or physiological measurements from relayed Class I and Class II devices. Rules may be created for reminders to be scheduled for periodic physiological measurements. Alerts are sent to the browser or to a computer or mobile device address that the user designates. MobileCare Monitor is not interpretive or predictive, nor is it intended to provide an automated treatment decision or act as a substitute for professional healthcare judgment. All patient medical diagnosis and treatment are to be performed under the direct supervision and oversight of an appropriate healthcare professional.
Device Story
System comprises local wireless gateways (PANDA), remote server, and MyPHD wearable monitor; PANDAs form wireless mesh network in facility; MyPHD wearable includes panic button, impact sensor (tri-axial accelerometer), and skin temperature sensor; system relays data from COTS wireless medical devices (e.g., BP cuffs, glucometers) via Bluetooth/standard protocols; server stores data, compares against user-defined thresholds, and manages alerts; caregivers access data/alerts via secure web browser on PCs or mobile devices; system provides location tracking, battery status, and wear-detection; supports caregiver productivity by enabling remote monitoring and threshold-based alerting; not interpretive or predictive; requires professional healthcare oversight.
Clinical Evidence
No clinical performance data provided. Evidence consists of bench testing, system reliability/data concurrence testing, and a usability study conducted by independent researchers (NIH Grant 1R43AG029196-01A1) involving elderly participants to evaluate system feasibility, data transmission reliability, and user compliance with COTS wireless measurement devices.
Technological Characteristics
System uses PANDA wireless gateways (mesh network), remote server, and MyPHD wearable (plastic housing, wrist strap). Sensing: tri-axial accelerometer, skin temperature sensor. Connectivity: Bluetooth, internet/cellular networks. Security: 256-bit AES encryption. Software: web-based browser interface for data management and threshold configuration. Power: low-power wireless transceiver.
Indications for Use
Indicated for patients and elderly individuals in institutional, home, and community care settings requiring remote monitoring of daily activities, physiological data, and help-request capabilities.
Regulatory Classification
Identification
A radiofrequency physiological signal transmitter and receiver is a device used to condition a physiological signal so that it can be transmitted via radiofrequency from one location to another, e.g., a central monitoring station. The received signal is reconditioned by the device into its original format so that it can be displayed.
AFrame Digital Inc. MyPHD™ MobileCare Monitor (K090138)
Submission Summary (Full Text)
{0}------------------------------------------------
#### 510(k) Premarket Notification Submission AFrame Digital MobileCare Monitor
NOV 1 9 2002
### 510(k) Summary As required by 21 CFR §807.92(c)
### Submitter:
| 510(k) Owner: | AFrame Digital, Inc. |
|---------------------|---------------------------------------------------------------|
| Address: | 1889 Preston White Drive, Suite 101<br>Reston, Virginia 20191 |
| Contact Person: | Cindy Crump, CEO & President |
| Telephone: | 571.308.0147 |
| Date Prepared: | August 1, 2012 |
| Device Information: | |
## Trade Name:
MobileCare™ Monitor Common Name: MobileCare Monitor remote patient monitoring system Classification Name: Transmitters and Receivers, Physiological Signal, Radiofrequency, 21 CFR 870.2910 Product Code: DRG Panel: Cardiovascular
#### Substantial Equivalence:
Substantial Equivalence is claimed with respect to the following predicate device:
K103796 TeleMedCare Health Monitor
In addition, since the Class II functionality described in this PMN is being added to our previously cleared device, the AFrame Digital Inc. MyPHD™ MobileCare MonitorsM (K090138) is referenced herein as supplemental information.
#### Device Description:
AFrame Digital's MobileCare Monitor is a communications platform consisting of a local wireless gateway, a remote computer server and software.
Local Wireless Gateway. A Powered Automated Network Data Aggregator 1. (PANDA) is the wireless gateway to the remote server, similar to wireless routers used in homes and offices to provide wireless internet access. Three or more PANDAs are placed in a residential or patient environment to support internet- or
cellular-based communications between the AFrame Digital MyPHD (personal health device) and a remote computer server. In some configurations the server will be in
{1}------------------------------------------------
the same facility. All wireless messages are securely encrypted with 256-bit AES. The PANDA access points form a reliable, low-power wireless network 'mesh' in the facility for complete wireless coverage of all residents with MyPHD watches. This functionality was cleared in the AFrame Digital MyPHD MobileCare Monitor submission (K090138) in April 2009.
2. Remote Computer and Software. The remote computer server communicates with the PANDA devices. It analyzes the messages received against alert thresholds established by designated staff or caregivers. Staff may make inquiries of the status of wearable monitors. The location of a wearable monitor may be determined from its position relative to nearby fixed-position PANDAs. The server will store messages and status information concerning the residents. Staff will be able to annotate records with support information related to individual residents and patients. To enhance caregiver productivity and mobility, alerts, resident location and other important person-specific information is available using a secure web browser application from a portable electronic device (PED), laptop or fixedstation PC. This functionality was also cleared in the AFrame Digital MyPHD MobileCare Monitor submission (K090138) in April 2009.
The remote computer server also communicates with COTS local wireless gateways that incorporate standardized wireless communications protocols such as Bluetooth to receive health-related data from commercially available, wireless measurement devices (e.q. blood pressure cuffs, pulse-oximeters, weight scales, blood alucose meters, etc.). AFrame Digital's configuration protocols and web-based software tools specify whether a measurement device may be used by a single user or multiple users. They also integrate data from these devices with other personspecific information without the transmission of personal health information. The server's software displays the data remotely to access-enabled users or caregivers over a secure browser, and provides tools for them to select patient-specific alert thresholds.
3. MyPHD™ Wearable Monitor. This is a small plastic housing and wrist strap with an external "panic" button. Some variations will have additional buttons that may be assigned a messaging or privacy function by the product software (softsettable). Internally, there is an impact sensor that may indicate a fall and a skin temperature sensor to indicate if the monitor has been removed from the wrist. A microprocessor with an industry standard very low power wireless transceiver sends messages to a nearby PANDA. This functionality was cleared as a Class I Bed-Patient Monitor in the AFrame Digital MyPHD MobileCare Monitor submission (K090138) in April 2009. .
{2}------------------------------------------------
#### Indications for Use:
The MobileCare Monitor remote monitoring system is intended as a support in the care of patients and the elderly in institutional, home, and community care settings. Intended users include the monitored individuals and their caregivers.
MobileCare Monitor includes a MyPHD™ personal help device that is intended to monitor patients and the elderly as they qo about their daily activities. MyPHD can be affixed to the wrist, clipped to the waist or used in a bandage for attachment at other locations on the monitored individual, as determined by the patient or caregiver. MobileCare monitor provides the MyPHD location information, battery life and indication that it is being worn. MyPHD also includes a help button and a tri-axial accelerometer used to convey the degree of motion created by a wearer's movements to support an assessment of impacts.
MobileCare Monitor may also relay data from legally marketed Class I and Class II wireless medical devices to AFrame Digital secure remote server by means of industry standard networks and public carriers. These data are stored and may be retrieved with a secure web browser after the user presents satisfactory security credentials. Users may also request the data to be presented in graphical format.
Alerts can be sent when a patient presses a help button on the MyPHD or when any data value from MyPHD or relayed device exceeds an upper or lower limit threshold established by a user. These data include impact sensitivity settings and/or physiological measurements from relayed Class I and Class II devices. Rules may be created for reminders to take physiological measurements. Alerts are sent to the browser or to a computer or mobile device address that the user designates.
MobileCare Monitor is not interpretive or predictive, nor is it intended to provide an automated treatment decision or act as a substitute for professional healthcare judgment. All patient medical diagnosis and treatment are to be performed under the direct supervision and oversight of an appropriate healthcare professional.
#### Technological Characteristics:
The MobileCare Monitor is substantially equivalent to the predicate device in terms of the remote collection of health-related data, the wireless transmission of data from legally marketed, COTS medical devices (intended for home use), the transmission of data over wireless and internet networks to a remote server, the aggregation of data on a remote server, the display of data over security-enabled web browsers, the availability of software tools that allow designated caregivers to view and manage data and define alert thresholds based on available health-related parameters, and the ability to transmit alerts remotely to the portable electronic devices of designated caregivers.
{3}------------------------------------------------
### Safety and Efficacy
A comparative analysis has established that MobileCare Monitor is substantially equivalent to the predicate device TeleMedCare Health Monitor. MobileCare Monitor -- alone or authenticated to relay data from leqally marketed wireless measurement devices - cannot itself cause injury to a user, does not control the delivery of treatment or therapy and is not marketed as a device used to render a diagnosis. In delivering services, MobileCare Monitor does not rely upon an assessment of clinical performance data. For these reasons, MobileCare Monitor raises no new questions concerning the safety and efficacy of the device.
Safety and efficacy are established through internal quality assurance testing to determine system reliability and data concurrence when integrated with third party measuring devices. In addition, MobileCare Monitor's configuration to accept data from legally marketed COTS wireless measuring devices was first evaluated in 2009 by independent clinical researchers in a Phase I grant awarded by the HHS National Institutes of Health (Grant number 1R43AG029196-01A1), who conducted a study made up of elderly participants on the usability of COTS wireless physiological measurement devices connected to MobileCare Monitor and degree of participant compliance with study protocols. The study protocol included completion by each study participant of a daily survey on a touchscreen device regarding their reactions to the telehealth devices. Data from these devices were automatically transmitted to the MobileCare Monitor, and evaluated by the researchers for usability and reliability. Usability was ascertained by examining the number of proximal and distal readings gathered by the measuring devices divided by the total number of expected readings and the number of readings received by MobileCare Monitor divided by the number of expected readings. Reliability was ascertained by examining system reliability and data concurrence. The researchers determined that an end-to-end configuration is a feasible solution to the problem of acquiring and recording both physiological and survey data from the elderly population.
#### Performance Testing
Also, MobileCare Monitor undergoes extensive component, end-to-end, integration and quality assurance testing as part of a comprehensive approach to the ongoing development and testing of the MobileCare Monitor system, as required by the Quality Standards Regulation. These include software requirements and specifications, potential hazard identification and remediation (Failure Modes and Effects Analysis - FMEA), a requirements traceability matrix, unit testing, release notes, QA/System testing, release management, a version management system, code and documentation control and a bug tracking system.
{4}------------------------------------------------
#### DEPARTMENT OF HEALTH & HUMAN SERVICES
Image /page/4/Picture/1 description: The image shows the seal of the U.S. Department of Health and Human Services. The seal features the department's name encircling a symbol. The symbol is a stylized representation of a human figure. The text reads "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA".
#### Public Health Service
Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-002
AFrame Digital, Inc. C/O Cindy A. Crump 1889 Preston White Drive, Suite 101 Reston, Virginia 20191
Re: K122333
Trade/Device Name: MobileCare Monitor Regulation Number: 21 CFR 870.2910 Regulation Name: Transmitters and Receivers, Physiological Signal, Radiofrequency Regulatory Class: Class II Product Code: DRG Dated: October 31, 2012 Received: November 6, 2012
Dear Ms. Crump:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug. and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA), You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration. Iisting of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical
{5}------------------------------------------------
Page 2 - Cindy A. Crump
device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm.
Sincerely yours
Bram Zuckerman, M.D.
Director Division of Cardiovascular Devices Office of Device Evaluation Center for Devices and Radiological Health
{6}------------------------------------------------
Attachment A
# Indications for Use
510(k) Number (if known): K122333
Device Name: MobileCare Monitor
Indications for Use:
The MobileCare Monitor™ remote monitoring system is intended as a support in the care of patients and the elderly in institutional, home, and community care settings. Intended users include the monitored individuals and their caregivers.
MobileCare Monitor includes a MyPHD™ personal help device that is intended to monitor patients and the elderly as they go about their daily activities. MyPHD can be affixed to the wrist, clipped to the waist or used in a bandage for attachment at other locations on the monitored individual, as determined by the patient or caregiver. MobileCare monitor provides the MyPHD location information, battery life and indication that it is being worn. MyPHD also includes a help button and a tri-axial accelerometer used to convey the degree of motion created by a wearer's movements to support an assessment of impacts.
MobileCare Monitor may also relay physiological data from legally marketed Class I and Class II wireless medical devices (e.g. blood pressure cuff, weight scale, blood glucometer, etc.) to AFrame Digital secure remote servers by means of industry standard networks and public carriers. Physiological data transmitted from these devices are stored and may be retrieved with a secure web browser after the user presents satisfactory security credentials. Users may also request the data to be presented in graphical format.
Alerts can be sent when a patient presses a help button on the myPHD or when any data value from MyPHD or relayed device exceeds an upper or lower limit threshold established by a user. These data include impact sensitivity settings and/or physiological measurements from relayed Class I and Class II devices. Rules may be created for reminders to be scheduled for periodic physiological measurements. Alerts are sent to the browser or to a computer or mobile device address that the user designates.
MobileCare Monitor is not interpretive or predictive, nor is it intended to provide an automated treatment decision or act as a substitute for professional healthcare judgment. All patient medical diagnosis and treatment are to be performed under the direct supervision and oversight of an appropriate healthcare professional.
AND/OR
| Prescription Use | |
|------------------|--|
|------------------|--|
Over-The-Counter Use _X_
(Part 21 CFR 801 Subpart D)
(21 CFR 801 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Deyice Ev
(Division Sign-Off)
Division of Cardiovascular Devices
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.