← Product Code [LYY](/productcode/LYY) · K121844

# POWDER FREE NATURAL RUBBER LATEX EXAMINATION GLOVES (K121844)

_Worldmed Manufacturing Sdn. Bhd. · LYY · Sep 6, 2013 · General Hospital · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K121844

## Device Facts

- **Applicant:** Worldmed Manufacturing Sdn. Bhd.
- **Product Code:** [LYY](/productcode/LYY.md)
- **Decision Date:** Sep 6, 2013
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 880.6250
- **Device Class:** Class 1
- **Review Panel:** General Hospital

## Indications for Use

The Powder Free Natural Rubber Latex Examination Gloves is a single use disposable device intended for medical purposes that is worn on the hands of healthcare and similar personnel to prevent contamination between the healthcare personnel and the patient.

## Device Story

Device is a single-use, disposable natural rubber latex examination glove. Worn by healthcare and similar personnel to provide a barrier against infectious materials and contamination. Used in clinical settings to prevent cross-contamination between personnel and patients. Device is non-sterile. Performance relies on physical barrier properties, including watertight integrity and tensile strength, meeting ASTM D3578-05(2010) standards.

## Clinical Evidence

No clinical data. Substantial equivalence supported by bench testing including dimensions, physical properties, thickness, biocompatibility (ISO 10993-10), and watertight testing (21 CFR 800.20).

## Technological Characteristics

Material: Natural rubber latex. Standards: ASTM D3578-05(2010), ISO 10993-10:2002/Amd 1:2006(E), 21 CFR 800.20. Dimensions: Length ≥ 240mm, palm/finger thickness 0.08mm. Biocompatibility: Non-irritant, non-sensitizer. Protein content: ≤ 50 µg/dm². Watertight: AQL 1.5.

## Regulatory Identification

A non-powdered patient examination glove is a disposable device intended for medical purposes that is worn on the examiner's hand or finger to prevent contamination between patient and examiner. A non-powdered patient examination glove does not incorporate powder for purposes other than manufacturing. The final finished glove includes only residual powder from manufacturing.

## Predicate Devices

- MPXX™ Powder Free Natural Rubber Latex Examination Gloves ([K110250](/device/K110250.md))
- Powder Free Natural Rubber Latex Examination Gloves, Blue Color, Non-Sterile ([K101799](/device/K101799.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

Powder Free Natural Rubber Latex Examination Gloves

Attachment 17

# 510(k) SUMMARY

#### 1.0 Submitter :

| Name           | Worldmed Manufacturing Sdn. Bhd.                                             |
|----------------|------------------------------------------------------------------------------|
| Address        | Lot 18873, Kamunting Industrial Estate<br>34600 Taiping, Perak,<br>Malaysia. |
| Phone No.      | 605-892 5555                                                                 |
| Fax No.        | 605-829 5590                                                                 |
| Contact Person | Chandrasegaran (Mr)                                                          |

Date of Preparation : May 14, 2012

SEP 06 2013

#### 2.0 Name of the Device

Powder Free Natural Rubber Latex Examination Gloves

| Common Name :         | Patient Examination Gloves |
|-----------------------|----------------------------|
| Classification Name : | Patient Examination Gloves |
| 510(K) Number :       | K121844                    |

### Identification of The Legally Marketed Devices That equivalency is claimed: 3.0

Primary Predicate:

MPXX™ Powder Free Natural Rubber Latex Examination Gloves Company : Total Glove Company Sdn Bhd. 510(K) : K110250

Additional Predicate:

Powder Free Natural Rubber Latex Examination Gloves, Blue Color, Non-Sterile Company : Wear Safe (Malaysia) Sdn. Bhd. 510(K) : K101799

#### 4.0 Description of the Device:

The Powder Free Natural Rubber Latex Examination Gloves meets all the requirements of ASTM Specification D3578-05(2010) Standard Specification for Rubber Examination Gloves standard.

#### 5.0 Intended Use of the Device

The Powder Free Natural Rubber Latex Examination Gloves is a single use disposable device intended for medical purposes that is worn on the hands of healthcare and similar personnel to prevent contamination between the healthcare personnel and the patient.

{1}------------------------------------------------

## Summary of the Technological Characteristics of the Device: 6.0

The Powder Free Natural Rubber Latex Examination are summarized with the following technological characteristics compared to ASTM Specification D3578-05(2010) Standard Specification for Rubber Examination Gloves or equivalent standards.

| CHARACTERISTICS     | STANDARDS                                                                                                                                                                                                                                                                                                                                                                  | DEVICE PERFORMANCE                                                       |
|---------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------|
| Dimensions          | ASTM D3578-05(2010)                                                                                                                                                                                                                                                                                                                                                        | Meets standard requirements                                              |
| Physical Properties | ASTM D3578-05(2010)                                                                                                                                                                                                                                                                                                                                                        | Meets standard requirements                                              |
| Thickness           | ASTM D3578-05(2010)                                                                                                                                                                                                                                                                                                                                                        | Meets standard requirements                                              |
| Biocompatibility    | ISO 10993-10:2002/Amd<br>1:2006(E) Biological<br>evaluation of medical<br>devices - Part 10: Tests for<br>irritation and delayed-type<br>hypersensitivity<br>Amendment 1:2006-07-15<br>ISO 10993-10:2002/Amd<br>1:2006(E) Biological<br>evaluation of medical<br>devices - Part 10: Tests for<br>irritation and delayed-type<br>hypersensitivity<br>Amendment 1:2006-07-15 | Pass (Not a primary skin<br>irritant)<br>Pass (Not a contact sensitizer) |
| Watertight (1000ml) | 21 CFR 800.20                                                                                                                                                                                                                                                                                                                                                              | Pass                                                                     |

## Substantial Equivalent Based on Assessment of Non-Clinical Performance Data 7.0

The performance test data of non-clinical tests that support a determination of substantial equivalence is the same as mentioned immediately above.

### Substantial Equivalent Based on Assessment of Clinical Performance Data 8.0

Clinical data is not needed for gloves or most devices cleared by the 510(k) process.

{2}------------------------------------------------

## Substantial Equivalence Comparison 9.0

| Characteristic<br>and<br>parameters     | Medtexx<br>Manufacturing Sdn.<br>Bhd.                                                                                                                                                                                                                                                                | Total Glove<br>Company Sdn.<br>Bhd.<br>K110250                                                                                                                                                                                                                                                  | Wear Safe<br>(Malaysia) Sdn.<br>Bhd.<br>K101799                                                                                                                                                                                                                                                                                   | Substantial<br>Equivalence<br>(SE) |
|-----------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------|
| Product Code                            | 80LYY                                                                                                                                                                                                                                                                                                | 80LYY                                                                                                                                                                                                                                                                                           | 80LYY                                                                                                                                                                                                                                                                                                                             |                                    |
| Intended use                            | The Powder Free<br>Natural Rubber Latex<br>Examination Gloves is<br>a single use disposable<br>device intended for<br>medical purposes that<br>is worn on the hands of<br>healthcare and similar<br>personnel to prevent<br>contamination between<br>the healthcare<br>personnel and the<br>patient. | MPXX™ Powder<br>Free Natural<br>Rubber<br>Examination<br>Gloves is a single<br>use device<br>intended for<br>medical purposes<br>that is worn on the<br>hand of healthcare<br>and similar<br>personnel to<br>prevent<br>contamination<br>between<br>healthcare<br>personnel and the<br>patient. | Powder Free<br>Natural Rubber<br>Latex Examination<br>Gloves, Blue Color,<br>Non-Sterile is a<br>disposable device<br>intended for<br>medical purpose<br>that is intended to<br>be worn on the<br>hand for medical<br>purposes to provide<br>barrier against<br>potentially<br>infectious materials<br>and other<br>contamination | SE                                 |
| Width (Size<br>Medium)                  | Meets ASTM D 3578-<br>05(2010):<br>XS - 70 ± 10<br>S - 80 ± 10<br>M - 95 ± 10<br>L - 111 ± 10                                                                                                                                                                                                        | Meets ASTM D<br>3578-05                                                                                                                                                                                                                                                                         | Meets ASTM D<br>3578-05                                                                                                                                                                                                                                                                                                           | SE                                 |
| Overall length                          | -Length ≥ 240mm                                                                                                                                                                                                                                                                                      | -Length ≥ 240mm                                                                                                                                                                                                                                                                                 | Meets ASTM D<br>3578-05                                                                                                                                                                                                                                                                                                           | SE                                 |
| Palm thickness                          | 0.08mm                                                                                                                                                                                                                                                                                               | 0.08mm                                                                                                                                                                                                                                                                                          | Meet ASTM D<br>3578-05                                                                                                                                                                                                                                                                                                            | SE                                 |
| Finger thickness                        | 0.08mm                                                                                                                                                                                                                                                                                               | 0.08mm                                                                                                                                                                                                                                                                                          | Meet ASTM D<br>3578-05                                                                                                                                                                                                                                                                                                            |                                    |
| Tensile Strength<br>per aging min.      | 18.0 MPa                                                                                                                                                                                                                                                                                             | Meets ASTM D<br>3578-05:                                                                                                                                                                                                                                                                        | Meet ASTM D 412                                                                                                                                                                                                                                                                                                                   |                                    |
| Tensile Strength<br>after aging min     | 14.0 MPa                                                                                                                                                                                                                                                                                             | - Tensile Strength<br>≥ 18MPa (≥<br>18MPa per<br>Standard )                                                                                                                                                                                                                                     | Meet ASTM D 412                                                                                                                                                                                                                                                                                                                   |                                    |
| Ultimate<br>elongation pre<br>aging min | 650%                                                                                                                                                                                                                                                                                                 | Meets ASTM D<br>3578-05:                                                                                                                                                                                                                                                                        | Meet ASTM D 412                                                                                                                                                                                                                                                                                                                   |                                    |
| Ultimate<br>elongation after<br>aging   | 500%                                                                                                                                                                                                                                                                                                 | - Elongation ≥<br>650%                                                                                                                                                                                                                                                                          | Meet ASTM D 412                                                                                                                                                                                                                                                                                                                   |                                    |
| Meets<br>Biocompatibility               | Yes                                                                                                                                                                                                                                                                                                  | Yes                                                                                                                                                                                                                                                                                             | Yes                                                                                                                                                                                                                                                                                                                               | SE                                 |
| Duration of bio-<br>compatibility       | Limited                                                                                                                                                                                                                                                                                              | Limited                                                                                                                                                                                                                                                                                         | Limited                                                                                                                                                                                                                                                                                                                           |                                    |
| Skin irritation                         | Passes                                                                                                                                                                                                                                                                                               | Passes                                                                                                                                                                                                                                                                                          | Not a primary skin irritant                                                                                                                                                                                                                                                                                                       |                                    |
| Dermal sensitization                    | Passes                                                                                                                                                                                                                                                                                               | Passes                                                                                                                                                                                                                                                                                          | Not a contact skin sensitizer                                                                                                                                                                                                                                                                                                     |                                    |
| Residual powder test                    | Passes                                                                                                                                                                                                                                                                                               | Meets Applicable Definition for Powder<br>Free; $\le$ 2 mg per glove                                                                                                                                                                                                                            | Meets ASTM D 6124-06                                                                                                                                                                                                                                                                                                              |                                    |
| Freedom from Holes                      | Meets Requirements per 21CFR800.20:<br>Gloves Free of Holes at quality level of AQL 1.5<br>(AQL 2.5 required per standard)                                                                                                                                                                           | Meets Requirements per 21CFR800.20:<br>Gloves Free of Holes at quality level of AQL 1.5<br>(AQL 2.5 required per standard)                                                                                                                                                                      | Meets ASTM D 5151-06                                                                                                                                                                                                                                                                                                              | Yes, SE                            |
| Materials                               | Natural Rubber Latex                                                                                                                                                                                                                                                                                 | Natural Rubber Latex                                                                                                                                                                                                                                                                            | Natural Rubber Latex                                                                                                                                                                                                                                                                                                              | Yes, Substantial Equivalence       |
| Protein Content                         | Meets Applicable Definition for Protein Content; $\le$ max 50 (ug/dm²)                                                                                                                                                                                                                               | Meets Applicable Definition for Protein Content; $\le$ max 50 (ug/dm²)                                                                                                                                                                                                                          | Meets ASTM D 5712-05                                                                                                                                                                                                                                                                                                              | Yes, Identical                     |

{3}------------------------------------------------

## Powder Free Natural Rubber Latex Examination Gloves

## Attachment 17

#### 10.0 Conclusion

.

ﮯ

Powder Free Natural Rubber Latex Examination Gloves will perform according to the gloves performance standards referenced in section 6.0 above and meets ASTM standards and FDA requirements for water leak test on pinhole AQL. Consequently, the device is substantially equivalent to currently marketed devices.

{4}------------------------------------------------

Image /page/4/Picture/0 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo is a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES USA" arranged around the perimeter. Inside the circle is a stylized image of an eagle with its wings spread, symbolizing the department's mission to protect the health of all Americans.

## DEPARTMENT OF HEALTH & HUMAN SERVICES

Public Health Service

Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G60 Silver Spring, MD 20993-0002

September 6, 2013

WorldMed Manufacturing Sdn. Bhd. Mr. Chandrasegaran Unite Head, Quality Assurance & Regulatory Affairs Lot 18873. Jalan Perusahaan 3. Kamunting Industrial Estate Kamunting Perak MALAYSIA 34600

Re: K121844

Trade/Device Name: Powder Free Natural Rubber Latex Examination Gloves Regulation Number: 21 CFR 880.6250 Regulation Name: Patient Examination Glove Regulatory Class: I Product Code: LYY Dated: August 6, 2013 Received: August 12, 2013

Dear Mr. Chandrascgaran:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments. or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug. and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations. Title 21. Parts 800 to 898. In addition. FDA may publish further announcements concerning your device in the Federal Register.

{5}------------------------------------------------

Page 2 - Mr. Chandrasegaran

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Small Manufacturers, International and Consumer Assistance at its tollfree number (800) 638-2041 or (301) 796-7100 or at its Internet address

http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to

http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.

You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address

http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm.

Image /page/5/Picture/7 description: The image shows a signature and contact information. The text "Sincerely yours" is at the top left of the image. Below the signature, the text "Tejashri Purohit-Sheth, M.D. Clinical Deputy Director DAGRID" is present.

Kwame Ulmer M.S. Acting Division Director Division of Anesthesiology, General Hospital, Respiratory, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{6}------------------------------------------------

Powder Free Natural Rubber Latex Examination Gloves

Attachment 2

ﮯ

-

| INDICATIONS FOR USE |
|---------------------|
|---------------------|

Applicant : WORLDMED MANUFACTURING SDN. BHD. LOT 18873, Kamunting Industrial Estate, 34600 Talping, Perak, Malaysia. 510(k) Number : K121844 (if known) POWDER FREE NATURAL RUBBER Device Name : LATEX EXAMINATION GLOVES Indications For Use :

The Powder Free Natural Rubber Latex Examination Gloves is a single use disposable device intended for medical purposes that is worn on the hands of healthcare and similar personnel to prevent contamination between the healthcare personnel and the patient

| Prescription Use   | OR Over-The-Counter                                                                                                                                                                                                                                                                                             | X |
|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---|
| Per 21 CFR 801.109 |                                                                                                                                                                                                                                                                                                                 |   |
|                    | Steven T. Elliott             S             Division Sign-Off)             Division of Anesthesiology, General Hospital             fection Control, Dental Devices                                                                                                                                             |   |
|                    | Oignally signed by Steven T. Elliott -S             DN: cn=Steven T. Elliott -S, o=U.S. Government, ou=HHS, ou=FDA, ou=People,             email=steven.elliott@fda.hhs.gov             0.9.2342.19200300.100.1.1=2000375530.             cn=Steven T. Elliott -S             Date: 2013.09.05 11:17:13 -04'00' |   |
|                    | 510(k) Number: K121844                                                                                                                                                                                                                                                                                          |   |

---

**Source:** [https://fda-staging.innolitics.com/device/K121844](https://fda-staging.innolitics.com/device/K121844)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).