K121560 · Thyssenkrupp Accessibility B.V. · ILK · Nov 1, 2012 · Physical Medicine
Device Facts
Record ID
K121560
Device Name
LEVANT, HOMEGLIDE
Applicant
Thyssenkrupp Accessibility B.V.
Product Code
ILK · Physical Medicine
Decision Date
Nov 1, 2012
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 890.5150
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
ThyssenKrupp Accessibility's Battery Operated Stair Lift Levant is intended to mechanically transport one mobility impaired person in a fold-down seat, up and down straight stairs, indoors and outdoors.
Device Story
Battery-operated stair lift for transport of one mobility-impaired person on straight stairs; indoor and outdoor use. System comprises drive unit, foldable footrest, and anodized aluminum rail fixed to stairs. Operation via 3-position momentary rocker switch; IR call/send functionality. Outdoor option includes waterproof controls, cover, coated electronics/switches, and waterproof charging contacts. Powered swivel and intermediate park position available as options. Device provides mechanical assistance to users with mobility impairments, facilitating navigation of stairs. Healthcare provider/user interaction limited to operation of controls for transit.
Clinical Evidence
No clinical data. Substantial equivalence is based on bench testing, adherence to safety standards (ASME 18.1, EN 81-40), and comparison of mechanical/electrical specifications against predicate devices.
Technological Characteristics
Anodized aluminum rail; ABS synthetic chair (outdoor); direct drive worm gear motor; 8dp gear rack with spur gear; dynamic/electromechanical braking; 24VDC power (2x 7AH batteries); IPx5 electrical enclosure; IR remote control; manual or powered swivel; foldable seat/footrest.
Indications for Use
Indicated for one mobility impaired person requiring mechanical transport up and down straight stairs, for indoor or outdoor use.
Regulatory Classification
Identification
Powered patient stairway chair lifts: A powered patient stairway chair lift is a motorized lift equipped with a seat and permanently mounted in one location that is intended for use in mitigating mobility impairment caused by injury or other disease by moving a person up and down a stairway. All other powered patient transport: A powered patient transport is a motorized device intended for use in mitigating mobility impairment caused by injury or other disease by moving a person from one location or level to another, such as up and down flights of stairs (e.g., attendant-operated portable stair-climbing chairs). This generic type of device does not include motorized three-wheeled vehicles or wheelchairs.
Special Controls
(i) Appropriate analysis and nonclinical testing (such as that outlined in the currently FDA-recognized edition of American Society of Mechanical Engineers (ASME) A18.1 “Safety Standard for Platform Lifts and Stairway Chair Lifts”) must demonstrate that the safety controls are adequate to prevent a free fall of the chair in the event of a device failure;
(ii) Appropriate analysis and nonclinical testing must demonstrate the ability of the device, including armrests, to withstand the rated load with an appropriate factor of safety;
(iii) Appropriate restraints must be provided to prevent the user from falling from the device (such as that outlined in the currently FDA-recognized edition of ASME A18.1 “Safety Standard for Platform Lifts and Stairway Chair Lifts”);
(iv) Appropriate analysis and nonclinical testing (such as that outlined in the currently FDA-recognized editions of AAMI/ANSI/IEC 60601-1-2, “Medical Electrical Equipment—Part 1-2: General Requirements for Safety—Collateral Standard: Electromagnetic Compatibility—Requirements and Tests,” and ASME A18.1 “Safety Standard for Platform Lifts and Stairway Chair Lifts”) must validate electromagnetic compatibility and electrical safety; and
(v) Appropriate analysis and nonclinical testing must demonstrate the resistance of the device upholstery to ignition.
Predicate Devices
Stair Lift BRUNO Independent Living Aids INC (K113308, K033438)
Submission Summary (Full Text)
{0}------------------------------------------------
NOV. 1
#### 510(k) SUMMARY as required by section 807.92(c)
| Submitted by: | ThyssenKrupp Accessibility BV<br>Van Utrechtweg 99<br>2921 LN Krimpen aan den Ijssel<br>The Netherlands |
|---------------------|---------------------------------------------------------------------------------------------------------|
| Contact: | Arnold van der Heiden<br>Mail: avanderheiden@tkacc.nl<br>Tel: +31 180 530900<br>Fax: +31 180 530901 |
| Date prepared: | 10/05/2012 |
| Trade Names: | LEVANT/HOMEGLIDE |
| Common Device Name: | Battery Operated Stair Lift for Straight Stairs |
| Regulation Number | 890.5150 |
| Class | II |
| Product Code: | ILK |
| Submission | K121560 |
| Predicate Devices: | Stair Lift BRUNO Independent Living Aids INC<br>K113308, K033438<br>CER 890.5150 |
#### Promotional Product Description
Levant/ HomeGlide is a stair lift for transport of one person up and down straight stairs. The system consist of a drive unit, a foldable footrest and an aluminum rail that is fixed on the stairs. The system can be fixed on either sides of the stairs.
It is available standard with a manual swivel for easy getting on and off the seat. It comes with a padded seat. A hinged rail, a heavy duty drive and a intermediate park position are available as options.
The Comfort Option provides a premium positioned chair lift with extra options: straight or curved armrests, luxurious seat, fabric- vinyl- or leather upholstery, adjustable seat height, and a powered swivel.
The Outdoor Option provides a stair lift for outdoor use in both cold and warm climates. The Outdoor option is created by adding a waterproof control, a waterproof cover, coated electronics, coated switches, waterproof charging contacts and a step up transformer.
1 2017
{1}------------------------------------------------
# Intended Use
ThyssenKrupp Accessibilty's Battery Operated Stair Lift Levant is intended to mechanically transport one mobility impaired person in a fold-down seat, up and down straight stairs, indoors and outdoors.
## Product Comparison Tables
Equivalent Technological Characteristics
| | Bruno SRE-3000/ SRE-2000 | ThyssenKrupp Accessibility Levant |
|----------------|-------------------------------------|------------------------------------|
| Standards | ASME 18.1 | ASME 18.1 |
| Application | Straight stairs | Straight stairs |
| Rated Load | 181 kg | 146 kg |
| Passengers | 1 | 1 |
| Power | 2 pieces 7AH 12 Battery | 2 pieces 7AH 12 Battery |
| Charger | 24VDC/ 2A | Ind:24VDC/ 1700 mA Outd: 6 VAC |
| Drive | Direct drive worm gear motor | Direct drive worm gear motor |
| Final Drive | 8dp gear rack with spur gear | 8dp gear rack with spur gear |
| Braking | Dynamic, worm gear, el/mech brake | Dynamic, worm gear, el/mech brake |
| Call & Send | IR | IR |
| Control | 3-position momentary rocker switch | 3-position momentary rocker switch |
| Supports | Anchored to stair thread | Anchored to stair thread |
| Angle | 22 to 45 degrees, specials up to 52 | 28 to 53 degrees, heavy duty to 45 |
| Speed | 0.08 m/s | 0.12 m/s |
| Track length | 6.1 meters max | 7.5 meters max |
| Construction | Aluminum extrude rail | Anodized aluminum extrude rail |
| Rail Indoors | | |
| Safety devices | Multiple | Multiple |
| Footrest | Folding type | Folding type |
| Seat | Folding type | Folding type |
| Indoor use | Yes | Yes |
| Outdoor use | Yes | Yes |
## Non Equivalent Technological Characteristics
| | Bruno SRE-3000/ SRE-2000 | ThyssenKrupp Accessibility Levant |
|--------------------------------|------------------------------------------------------------------|--------------------------------------------------------------------|
| Temperature<br>range Indoors | SRE-3000 (Bruno ref ILS-01024):<br>not specified | Levant Standard + Comfort option:<br>+5°C to +40°C (41°F to 104°F) |
| Temperature<br>range Outdoors | SRE-2000 (Bruno ref ISO-404.88)<br>-5°C to +50°C (25°F to 125°F) | Levant Outdoor option:<br>-15°C to +60°C (5°F to 140°F) |
| Construction<br>Rail Outdoors | Exterior grade powder coated steel<br>rail | Anodized aluminum extrude rail |
| Construction<br>Chair Outdoors | Stainless steel | ABS Synthetic material |
| Electrical<br>enclosure | IPx3 | IPx5 |
{2}------------------------------------------------
#### Product Comparison Discussion
Bruno's SRE-3000/ SRE-2000 and ThyssenKrupp Accessibility's Levant show substantial equivalence on most features and characteristics.
- Both products offer a higher rated load then the minimum requested by standards (EN . Doth products offer a mights offers a maximum of 181 kg, where ThyssenKrupp Accessibility offers a maximum of 146 kg.
- Both product offer the possibility to install the rail at the maximum angle of . inclination (EN 75°, ASME 45°). There is a small difference in the angle range, caused by differences in the design.
- Both products a travelling speed that is below the maximum allowed by standards (EN . 0,15 m/s, ASME 0,4 m/s). Bruno specifies a speed of 0,08 m/s where ThyssenKrupp Accessibility offers a speed that is 50% higher.
- Standards do not specify a maximum track length. Bruno offers a maximum track . length of 6,1 meters, where ThyssenKrupp Accessibility offers a maximum track length of 7,5 meters.
- Regarding the temperature range of the outdoor chair versions (Bruno SRE-2000 . stainless steel, Levant Outdoor ABS Synthetic material) there is a difference. Where Bruno offers a minus temperature of 25°F, ThyssenKrupp Accessibility offers a Diano Chero a lemperature of 59F. Where Bruno offers a maximum temperature of 1259F, ThyssenKrupp Accessibility offers a maximum temperature of 140°F.
Small differences as listed above are subject to analysis of specific customer demands by the sales person.
Bruno's SRE-3000/ SRE-2000 and ThyssenKrupp Accessibility's Levant show less substantial equivalence on the features and characteristics listed below.
- ThyssenKrupp Accessibility offers anodized aluminium as rail material, where Bruno t offers exterior grade coated steel. Although substantially different, both materials fulfil the requirements regarding the requested safety factors by the standards. The choice of material is subject to the taste of the end user.
- Bruno offers as protection against spraying water class IPx3, where IPx5 is offered by . ThyssenKrupp Accessibility. IP55 is required by EN 81-40 referenced according IEC Friyssellicrapp Feesssive a required IP level. The substantial difference can be explained by the fact that Levant is a European design, that has to meet EN 81-40. The explained by the fact than be subject of analysis of specific customer demands by the sales person.
Bruno's SRE-3000/ SRE-2000 and ThyssenKrupp Accessibility's Levant show minor Differences in features and characteristics. From the point of view from ThyssenKrupp Technical Advisor, both products can be considered as substantially equal where the I venined frames, or adaption to specific customer demands, creating a bigger chance for mobility impaired persons to find suitable solution.
{3}------------------------------------------------
Image /page/3/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo features a stylized depiction of an eagle or bird-like figure, with its wings spread and body formed by curved lines. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA" is arranged in a circular pattern around the bird symbol.
Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring, MD 20993-0002
NOV
Thyssenkrupp Accessibility B.V. % Mr. Arnold Heiden Technical Advisor Van Utrechtweg 99 Krimpen aan den Ijssel Zuid-Holland, Netherlands 2921 LN
Re: K121560
Trade/Device Name: LEVANT Regulation Number: 21 CFR 890.5150 Regulation Name: Powered patient transport Regulatory Class: Class II Product Code: ILK Dated: October 24, 2012 Received: October 25, 2012
Dear Mr. Heiden:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
1 2012
{4}------------------------------------------------
## Page 2 - Mr. Arnold Heiden
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm.
#### Sincerely yours,
Peter D. Rumm -5 2012.11.01 14:50:25 -04'00'
> Victor Krauthamer, Ph.D. Acting Director Division of Neurological and Physical Medicine Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{5}------------------------------------------------
# Indications for Use
510(k) Number (if known): _K121560
Device Name: LEVANT
Indications for Use:
ThyssenKrupp Accessibility's Battery Operated Stair Lift LEVANT is intended to ThyssellRrupp Accessibility S Buttery Opered or son in a fold-down seat, up and down straight stairs, indoors and outdoors.
Prescription Use NO (Part 21 CFR 801 Subpart D)
Over-The-Counter Use YES AND/OR (21 CFR 801 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE OF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
(Division Sign-Off) Division of Surgical, Orthopedic, and Restorative Devices
Page 1 of 1
510(k) Number K121560
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.