← Product Code [GEX](/productcode/GEX) · K121471

# LIGHTSCALPEL FAMILY OF HANDPIECE TIPS FOR CO2 SURGICAL LASERS (K121471)

_Lightscalpel, LLC · GEX · Jul 10, 2012 · General, Plastic Surgery · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K121471

## Device Facts

- **Applicant:** Lightscalpel, LLC
- **Product Code:** [GEX](/productcode/GEX.md)
- **Decision Date:** Jul 10, 2012
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 878.4810
- **Device Class:** Class 2
- **Review Panel:** General, Plastic Surgery
- **Attributes:** Therapeutic

## Indications for Use

Intended use is to communicate the laser beam of a CO2 surgical laser to the target site for the incision, excision, ablation, or photocoagulation of soft tissue. Representative examples of indications for use: Gynecology-excision and vaporization of cervical, vulvar, and perineal condyloma; ablation of vaginal and vulvar intraepithelial neoplasia; herpes vaporization; vaporization of urethral caruncle; I&D Bartholin's and nubothian cysts. Dermatology - port wine hemangioma removal; rhinophyma reduction; telangiectasia removal; wart removal; basal squamous cell carcinoma removal; blepharoplasty; xanthalasma removal; removal of neurofibromas hemangiomas, nevi, and tircoeptiheliomas; dermabrasion for lentigos, keratosis, actinic keratosis and actinic cheilitis. Dentistry/Oral Surgery - gingivectomy; frenum release; gingivoplasty; removal of soft tissue, cysts, and tumors General Surgery – hemorrhoid removal; skin tag vaporization; pilodidal cyst removal and repair; debridement of deciditus ulcers and stasis ulcers; mastectomy; breast biopsy, reduction mammoplasty; cyto-reduction for metastatic disease; many dermatological procedures. Laparoscopic surgery - vaporization, incision, excision, ablation, or photo-coagulation of soft tissue such as endometriosis ablation, excision of adhesions, salpingotomy. Otorhinolaryngology - lymphangioma removal; turbinectomy, subglottic stenosis vaporization, tonsillectomy, removal of vocal cord papillomas, nodules, and polyps. Podiatry - plantar wart vaporization; fungal nail treatment; partial and complete matrixectomy; porokeratoma ablation; Morton's neuroma removal; ingrown toenail treatment Orthopedic - menisectomy, chondromalacia ablation, partial synovectomy, lateral release, PMMA removal

## Device Story

Device consists of short, hollow lightpipe tips made of alumina ceramic or stainless steel; attaches to mating CO2 surgical laser handpieces. Tips function as beam delivery accessories to direct laser energy to target soft tissue for incision, excision, ablation, or photocoagulation. Used by clinicians in various surgical settings (OR, clinic). Benefits include precise tissue interaction for diverse surgical applications. Device is identical to predicate in construction and performance; primary difference is transition from user-performed steam sterilization to pre-sterilized radiation sterilization.

## Clinical Evidence

No clinical data provided. Bench testing only; validation of sterilization parameters for radiation sterilization to 10^-6 SAL.

## Technological Characteristics

Materials: alumina ceramic or stainless steel. Form factor: short, hollow lightpipe tips. Energy source: CO2 surgical laser (external). Sterilization: pre-sterilized radiation (10^-6 SAL).

## Regulatory Identification

(1) A carbon dioxide laser for use in general surgery and in dermatology is a laser device intended to cut, destroy, or remove tissue by light energy emitted by carbon dioxide.(2) An argon laser for use in dermatology is a laser device intended to destroy or coagulate tissue by light energy emitted by argon.

## Predicate Devices

- Aesculight family of fibers, handpieces, and tips for CO2 surgical lasers ([K081612](/device/K081612.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

# Section 5: 510(k) summary

# K121471

Date Prepared: 28 June 2012

JUL 1 0 2012

Submitters name, address, telephone, fax, and contact person:

LightScalpel LLC 16932 Woodinville-Redmond Rd NE Suite 201 Woodinville, WA 98072 425-408-9477 425-487-1157 fax Gerald S. Palecki, General Manager

Product Trade Name: LightScalpel family of handpiece tips for CO2 surgical lasers

Product common names: Accessory laser tips

Classification names: Laser surgical instrument for use in general and plastic surgery and in dermatology, 21CFR 878.4810, product code GEX . Panel: General and plastic surgery devices,

Legally marketed predicate device: Aesculight family of fibers, handpieces, and tips for CO2 surgical lasers. (K081612)

Device description: These tips are short, hollow lightpipes of alumina ceramic or stainless steel that provide a variety of spot sizes to target tissue when utilized in a mating laser handpiece.

Intended use: The intended use is to communicate the laser beam of a CO₂ surgical laser to the target site for the incision, excision, ablation, or photocoagulation of soft tissue. Representative examples of indications for use:

Gynecology-excision and vaporization of cervical, vulvar, and perineal condyloma; ablation of vaginal and vulvar intraepithelial neoplasia; herpes vaporization; vaporization of urethral caruncle; I&D Bartholin's and nubothian cysts.

Dermatology - port wine hemangioma removal; rhinophyma reduction; telangiectasia removal; wart removal; basal squamous cell carcinoma removal; blepharoplasty; xanthalasma removal; removal of neurofibromas hemangiomas, nevi, and tircoeptiheliomas; dermabrasion for lentigos, keratosis, actinic keratosis and actinic cheilitis.

Dentistry/Oral Surgery - gingivectomy; frenum release; gingivoplasty; removal of soft tissue, cysts, and tumors

General Surgery – hemorrhoid removal; skin tag vaporization; pilodidal cyst removal and repair; debridement of deciditus ulcers and stasis ulcers; mastectomy; breast

{1}------------------------------------------------

biopsy, reduction mammoplasty; cyto-reduction for metastatic disease; many dermatological procedures.

Laparoscopic surgery - vaporization, incision, excision, ablation, or photo-coagulation of soft tissue such as endometriosis ablation, excision of adhesions, salpingotomy.

Otorhinolaryngology - lymphangioma removal; turbinectomy, subglottic stenosis vaporization, tonsillectomy, removal of vocal cord papillomas, nodules, and polyps.

Podiatry - plantar wart vaporization; fungal nail treatment; partial and complete matrixectomy; porokeratoma ablation; Morton's neuroma removal; ingrown toenail treatment

Orthopedic - menisectomy, chondromalacia ablation, partial synovectomy, lateral release, PMMA removal

No new indications for use are sought beyond those associated with the predicate device.

Summary technological characteristics and comparison to Predicates: These products are identical to the predicate products, utilizing the same specifications, materials and methods. The only difference between these products and the predicates is the final sterilization method and the attendant packaging and labeling. The sterilization method changes from user steam sterilization with the predicate to pre-sterilized radiation sterilization with the submitted devices. Both sterilization methods demonstrate the ability to sterilize to 10 € SAL.

Nonclinical Performance Data: Data were provided relative to the validation of sterilization parameters required for obtaining 105 SAL utilizing radiation sterilization.

Clinical Performance Data: None

Conclusion: The submitted devices are substantially equivalent to the predicate devices with identical construction and performance with validated sterilization to 100 SAL.

{2}------------------------------------------------

Image /page/2/Picture/1 description: The image is a black and white seal for the Department of Health & Human Services - USA. The seal is circular with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter of the circle. In the center of the seal is a stylized image of an eagle.

JUL 10 2012

Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring, MD 20993-0002

LightScapel, LLC % Mr. Gerald S. Palecki General Manager 16932 Wood-Red Road Northeast Suite 201 Woodinville, Washington 98072

### Re: K121471

Trade/Device Name: LightScalpel family of handpiece tips for CO2 surgical lasers Regulation Number: 21 CFR 878.4810

Regulation Name: Laser surgical instrument for use in general and plastic surgery and in dermatology

Regulatory Class: II Product Code: GEX Dated: May 14, 2012 Received: May 18, 2012

#### Dear Mr. Palecki:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act 

{3}------------------------------------------------

Page 2 - Mr. Gerald S. Palecki

or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to

http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.

You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm.

Sincerely vours.

signature

2 Mark N. Melkerson Director Division of Surgical, Orthopedic and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{4}------------------------------------------------

## Section 4: Indications for Use Statement

510(k) Number (if known):

Device Name: LightScalpel family of handpiece tips for CO2 surgical lasers

Indications for Use:

Intended use is to communicate the laser beam of a CO2 surgical laser to the target site for the incision, excision, ablation, or photocoagulation of soft tissue. Representative examples of indications for use:

Gynecology-excision and vaporization of cervical, vulvar, and perineal condyloma; ablation of vaginal and vulvar intraepithelial neoplasia; herpes vaporization; vaporization of urethral caruncle; I&D Bartholin's and nubothian cysts.

Dermatology – port wine hemangioma removal; rhinophyma reduction; telangiectasia removal; wart removal; basal squamous cell carcinoma removal; blepharoplasty; xanthalasma removal; removal of neurofibromas hemangiomas, nevi, and tircoeptiheliomas; dermabrasion for lentigos, keratosis, actinic keratosis and actinic cheilitis.

Dentistry/Oral Surgery – gingivectomy; frenum release; gingivoplasty; removal of soft tissue, cysts, and tumors

General Surgery - hemorrhoid removal; skin tag vaporization; pilodidal cyst removal and repair; debridement of deciditus ulcers and stasis ulcers; mastectomy; breast biopsy, reduction mammoplasty; cyto-reduction for metastatic disease; many dermatological procedures.

Laparoscopic surgery – vaporization, incision, excision, ablation, or photo-coagulation of soft tissue such as endometriosis ablation, excision of adhesions, salpingotomy.

Otorhinolaryngology - lymphangioma removal; turbinectomy, subglottic stenosis vaporization, tonsillectomy, removal of vocal cord papillomas, nodules, and polyps.

Podiatry – plantar wart vaporization; fungal nail treatment; partial and complete matrixectomy; porokeratoma ablation; Morton's neuroma removal; ingrown toenail treatment

Orthopedic - menisectomy, chondromalacia ablation, partial synovectomy, lateral release, PMMA removal

| Prescription use           | Yes |
|----------------------------|-----|
| (Part 21CFR 801 Subpart D) |     |

ANDND/OR

Over-The-Counter Use (21 CFR 801 Subpart C)

Nelkegl Concurrence of CDRH, Office of device Evaluation (ODE)

Division of Surgical, Orthopedic, and Restorative Devices

510(k) Number K121471

LightScalpel LLC 510(k) Submission page 4-1

---

**Source:** [https://fda-staging.innolitics.com/device/K121471](https://fda-staging.innolitics.com/device/K121471)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
