K121150 · Alma Lasers, Inc. · GEI · Sep 21, 2012 · General, Plastic Surgery
Device Facts
Record ID
K121150
Device Name
ALMA LASERS FAMILY OF PIXEL RF TIPS
Applicant
Alma Lasers, Inc.
Product Code
GEI · General, Plastic Surgery
Decision Date
Sep 21, 2012
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 878.4400
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The Alma Lasers Family of Accent RF Systems [Accent XL, Accent Elite] is intended for use in dermatologic and general surgical procedures. The Unipolar and Bipolar handpieces, when used as a combined treatment, are indicated for the non-invasive treatment of wrinkles and rhytids. The Pixel RF Tips (stationary and rolling), when used with the unipolar handpiece, are indicated for dermatological procedures requiring ablation and resurfacing of the skin.
Device Story
Accent Pixel RF Tips are radiofrequency (RF) energy delivery accessories for the Alma Lasers Accent RF system. Tips are available in stationary and roller configurations; constructed from aluminum and sapphire. Device functions by delivering unipolar RF energy to skin tissue to induce ablation and resurfacing. Used in clinical settings by healthcare professionals. Output is thermal energy applied to the skin surface; clinical effect is tissue ablation and resurfacing for wrinkle reduction. Benefits include non-invasive skin rejuvenation. System operates via connection to the Accent RF console; energy parameters are controlled by the clinician.
Clinical Evidence
Performance substantiated by animal histology data and human clinical data. No specific quantitative metrics (e.g., p-values, sensitivity) provided in the summary.
Technological Characteristics
RF energy delivery accessory; stationary and roller tip configurations. Materials: aluminum and sapphire. Stationary tip: ~110 points (1.0 pixels/mm²). Roller tip: ~132 points/cm (1.3 pixels/mm²). Energy source: Unipolar RF from Accent system console. Sterilization: cleanable/sterilizable (reusable) or disposable options.
Indications for Use
Indicated for patients requiring dermatological procedures for skin ablation and resurfacing, and for the non-invasive treatment of wrinkles and rhytids when used with the unipolar handpiece.
Regulatory Classification
Identification
An electrosurgical cutting and coagulation device and accessories is a device intended to remove tissue and control bleeding by use of high-frequency electrical current.
Predicate Devices
Alma Lasers Family of Accent RF Systems [Accent, Accent Elite] (K072699, K070004, K101147)
{0}------------------------------------------------
Section 5-510(k) Summary or 510(k) Statement
K121150
Page 1 of 8
SEP 21 2012
| I. General Information | |
|---------------------------|-----------------------------|
| Submitter: | Alma Lasers, Inc. |
| | 485 Half Day Road Suite 100 |
| | Buffalo Grove IL 60089 |
| Contact Person: | Kathy Maynor - Regulatory |
| | 352-586-3113 (cell) |
| Summary Preparation Date: | June 28, 2012 |
| II. Names | |
|---------------------------------|----------------------------------------------------------------|
| Device Name(s): | Accent Pixel RF Tips |
| Primary Classification Name(s): | Electrosurgical cutting and coagulation device and accessories |
III. Predicate Devices#### Predicate Devices III.
・
- Alma Lasers Family of Accent RF Systems [Accent, Accent Elite] (K072699, K070004, . K101147)
- Syneron Medical Matrix RF Applicator (K073572, K090025) .
- EndyMed RF Applicator (K083461, K101510, K120513) .
{1}------------------------------------------------
Page 2 of (8)
#### Product Description IV.
The Accent Pixel RF Tips include cleanable, sterilizable, multiple use radiofrequency (RF) energy delivery devices (accessory) intended for use with the Alma Lasers Family of Accent™ RF Systems [Accent, Accent XL, Accent Elite]. These Pixel RF Tips are also available as single use, disposable products.
The Accent Pixel RF Tips are comprised of the following main components:
- Pixel Stationary Tip .
- Pixel Roller Tip .
- V. Intended Use & Indications for Use
# Intended Use
The Alma Lasers family of Accent RF Systems (Accent XL, Accent Elite) with Unipolar and Bipolar Handpieces are intended for use in dermatologic and general surgical procedures.
## Indications for Use
The Unipolar and Bipolar handpieces, when used as a combined treatment, are indicated for the noninvasive treatment of wrinkles and rhytids.
The Pixel RF Tips (stationary and rolling), when used with the unipolar handpiece, are indicated for dermatological procedures requiring ablation and resurfacing of the skin.
#### VI. Rationale for Substantial Equivalence
The Accent Pixel RF Tips shares the same or similar indications for use, device operation, overall technical and functional capabilities, and therefore is substantially equivalent to the predicate devices. Additionally, animal and human clinical data were submitted to substantiate product performance.
{2}------------------------------------------------
| | K0XXXX | K072699, K070004,<br>K101147 | K073572, K090025 | K083461, K101510, K120513 |
|----------------|------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------|------------------------------------------------------------------------|
| | Alma Lasers, Ltd. | | Syneron Medical | EndyMed |
| | Family of Accent RF Pixel Tips with<br>PixelRF Module/ Handpiece | Alma Lasers Family of<br>Accent RF Systems<br>[Accent, Accent XL,<br>Accent Elite] (w/ UniPolar<br>& BiPolar Handpieces] | Matrix RF Applicator | RF applicator |
| Characteristic | | | | |
| Product Code | | General & Plastic Surgery | General & Plastic Surgery | General & Plastic Surgery |
| Regulation | | • NUV,GEI, ISA 21 CFR<br>878.4810 | • GEI, OUH - 21 CFR 878.4400 | • GEI, OUH - 21 CFR 878.4400 |
| Intended Use | | Intended for use in<br>dermatologic and general<br>surgical procedures | Intended for use in<br>dermatologic and general<br>surgical procedures | Intended for use in<br>dermatologic and general<br>surgical procedures |
:
Section 5: Page 3
.
Premarket Notification, Special 510(k) Submission for
Alma Lasers Accent Pixel® Tips
.
K 121150
:
.• •
39 (દ
12115
{3}------------------------------------------------
| K0XXXX | K072699, K070004,<br>K101147 | K073572, K090025 | K083461, K101510, K120513 | |
|---------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------|
| Alma Lasers, Ltd. | | Syneron Medical | EndyMed | |
| Family of Accent RF Pixel Tips with PixelRF Module/ Handpiece | Alma Lasers Family of Accent RF Systems<br>[Accent, Accent XL,<br>Accent Elite] (w/ UniPolar<br>& BiPolar Handpieces] | Matrix RF Applicator | RF applicator | K121150<br>Page |
| Characteris<br>tics | The Alma Lasers family of Accent RF<br>Systems (Accent, Accent XL, Accent<br>Elite) with Unipolar and Bipolar<br>Handpieces are intended for use in<br>dermatologic and general surgical<br>procedures: | The Matrix RF Applicator<br>is intended for<br>dermatological procedures<br>requiring ablation<br>and resurfacing of the skin,<br>and for the treatment of<br>facial wrinkles. | The Glow by EndyMed is a<br>noninvasive device intended<br>for use in Dermatologic and<br>General Surgical procedures.-<br><br>The TC applicator is indicated<br>for mild to moderate facial<br>wrinkles and rhytides. | |
| Indications<br>for Use | Indicated for: The non-<br>invasive treatment of<br>wrinkles and rhytids using<br>a combined treatment with<br>Unipolar and Bipolar<br>handpieces | | The FSR applicator is<br>indicated for Dermatological<br>procedures requiring ablation<br>and resurfacing of the skin. | |
| | The Unipolar and Bipolar handpieces,<br>when used as a combined treatment,<br>are indicated for the non-invasive<br>treatment of wrinkles and rhytids. | | | |
| | The Pixel RF Tips (stationary and<br>rolling), when used with the unipolar<br>handpiece, are indicated for<br>dermatological procedures requiring<br>ablation and resurfacing of the skin. | | | |
| | Supported by animal histology data<br>- section 19 - and human clinical<br>data - section 20. | | | |
:
:
.
Premarket Notification, Special 510(k) Submission for
Alma Lasers Accent Pixel" Tips
Section 5: Page 4
al (જે) 4 e
{4}------------------------------------------------
| | K0XXXX | K072699, K070004,<br>K101147 | K073572, K090025 | K083461, K101510, K120513 |
|-------------------------|------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------|
| | Alma Lasers, Ltd. | | Syneron Medical | EndyMed |
| | Family of Accent RF Pixel Tips with<br>PixelRF Module/ Handpiece | Alma Lasers Family of<br>Accent RF Systems<br>[Accent, Accent XL,<br>Accent Elite] (w/ UniPolar<br>& BiPolar Handpieces] | Matrix RF Applicator | RF applicator |
| Characteris<br>tic | | | | |
| RF Power<br>(or Energy) | • UniPolar<br>- Recommended Range -<br>Stationary Tips<br>45-60 W | | • Bipolar - Up to 25 Joules<br>per cm² | • Bipolar up to 65 watts |
| | - Recommended Range - Roller<br>Tips<br>35-55 W | • UniPolar & UniLarge<br>Up to 200 W (1.51 W/mm²)<br>(Nominal 120-140 W) | (Tunable SelectPulse™<br>fractional technology – 3<br>programs which emulate the<br>tissue effects of common<br>skin resurfacing fractional<br>laser technologies) | Up to 62mj/pin |
| | - Maximum for Accent System<br>Up to 200 W (2.08 W/mm²)<br>(Nominal 35-80 W - PixelRF Tips –<br>range of 0.15 to 2.08 W/mm²) | • BiPolar & BiFolarS<br>Up to 420 W (1.51 W/mm²)<br>(Nominal 250-290 W) | | |
..
.. •
'
Premarket Notification, Special 510(k) Submission for
Alma Lasers Accent Pixel® Tips
:
Section 5: Page 5
.
p.
a
e
5
K 121150
ర్ P 9
્રિ
{5}------------------------------------------------
| | 0XXXX | K072699, K07000 K101147 | 073572, K09002 | 083461, K101510, K12051 |
|------------|--------------------------------------------------------------------------------------|-------------------------------------------------------------------|------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| | Alma Lasers, Ltd | | yneron Medic | indyMed |
| | amily of Accent RF Pixel Tips with<br>PixelRF Module/ Handpiece | lma Lasers Family of ccent RF Systems | latrix RF Applicator | . ****************************************************************************************************************************************************************************<br>RF applicator |
| | | Accent, Accent XL, Accent Elite] (w/ UniPol & BiPolar Handpieces] | | |
| Characteri | | | | |
| tic | | | | |
| Tip Matrix | Stationary PixelRF Tips | ot applicab | | 2 matrix spo |
| | · ~ 110 Pixel points (1.0 pixels/mm²) | . . | 64 Matrix Points – per pulse | (1.3 matrix spots/mm |
| | | K072699 & K070004 | | |
| | oller PixelRF Tips | | 0.4 points/mr | |
| | ~132 Pixel points per cm<br>(1.3 pixels/mm² | | | |
| | Treatment Stationary. PixelRF Tips (Unipolar) . | UniPolar & UniLarg | | 10.x 15.mm |
| Area | 12 mm dia | 13 to 19 mm dia | x 12 mm — disposable | |
| | • Roller PixelRF Tips (Unipolar) | BiPolarS & BiPola | spot' size (unipola | |
| | 10 x 22.7 mm circumference 'roller' | 95 to 13 mm dia | | |
| landpiece | Pixel - Handpiece - 160 x 155 mm | UniPolar - 169 x 205 mm | 5.9 x 6.3 inches (15 | Inknowi |
| Dimensions | | BiPolar - 167 x 203 mm | cm) | |
| | | | | |
| | Premarket Notification, Special 510(k) Submission for Alma Lasers Accent Pixel® Tips | | ection 5: Page | |
・・・・・・・・ . .
KI 21150
Page 6 of 8
{6}------------------------------------------------
| | 0XXX | K072699, K07000 K101147 | 073572, K09002 | 083461, K101510, K1205 |
|---------------------------|--------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------|----------------------------------|---------------------------------|
| | lma Lasers, Ltd | | neron Medic | EndyMed |
| | amily of Accent RF Pixel Tips wit ixel8f Module/ Handpiece | ma Lasers Family of cent RF Systems cent RF Systems cent RF Systems cent Elited (w/1L) (Lift (Lift) BiPolar Handy (w/10ces) | atrix RF Applicator | RF applicato: |
| | | | | |
| Character<br>tice | | | | |
| Patient | tationary Pixel Tips – Aluminum | andpiece | nknow | nknow |
| Materials<br>Contac | Roller Pixel®F Tips – Aluminum,<br>Sapphire | nodized aluminum ar<br>elrin plastic | | :<br>: |
| provideo<br>How | sposable and Reusable Stationary Roller Pixel® Tips: | ot applicab | sposable tip – up to<br>pulses | isposable tip - up to<br>oulses |
| | ble Tips<br>lable<br>Reusable, cleanable, steriliza<br>nd disposable tips also avail | | | |
| Electrical<br>Reqs | . …,<br>10-120 V; 50-60 Hz; 5 | 0-120 V, 50-60 Hz, 5 | 0 - 230 VAC, 50-60 Hz,<br>7.5A | 0-230 VAC, 1-3 A, 5<br>Hz |
| System Dimensions<br>(;;) | 6 x 17 x 16 AccentXL; 21 x 17 x 38 ccent; 26 x 18 x 16 Accent Beauty | 6 x 17 x 16 Accent)<br>l x 17 x 38 Acce | .87 x 15.35 x 11 abletop system) | 15 x 30 x 19 cm; 45 x<br>in. |
| System Weight | 10(XL) | ર Pas<br>S | 4 lbs (7 k | 3 kg; 72.5 |
.
Section 5: Page 7
Premarket Notification, Special 510(k) Submission for:
Alma Lasers Accent Pixel® Tips
2 || K 1 50
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ge 7 of 8
{7}------------------------------------------------
#### Safety and Effectiveness Information VII.
The review of the indications for use and technical characteristics provided demonstrates that the Accent Pixel RF Tips are substantially equivalent to the predicate devices. Additionally, animal and human clinical data were submitted to substantiate performance.
0
VIII. Conclusion
The Accent Pixel RF Tips were found to be substantially equivalent to the predicate devices.
The Accent Pixel RF Tips share the identical indications for use, similar design features, and functional features with, and thus are substantially equivalent to, the predicate devices.
{8}------------------------------------------------
# DEPARTMENT OF HEALTH & HUMAN SERVICES
Image /page/8/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo features a stylized depiction of an eagle or bird-like figure with three curved lines forming its body and wings. The logo is surrounded by text that reads "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" in a circular arrangement.
#### Public Health Service
Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring, MD 20993-0002
Alma Lasers Incorporated % Ms. Kathy Maynor Regulatory Consultant 485 Half Day Road, Suite W No. 100 Buffalo Grove, Illinois 60089
Re: K121150
Trade/Device Name: Pixel RF Tips Regulation Number: 21 CFR 878.4400 Regulation Name: Electrosurgical cutting and coagulation device and accesories Regulatory Class: Class II Product Code: GEI Dated: August 31, 2012 Received: September 11, 2012
Dear Ms. Maynor:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug. and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration. Iisting of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set
SEP 21 2012
{9}------------------------------------------------
## Page 2 - Ms. Kathy Maynor
forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm11.5809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm.
Sincerely yours,
Mark N. Melkerson
Director Division of Surgical, Orthopedic and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{10}------------------------------------------------
Page 1 of 2
## Indications for Use Statement
510(k) Number (if known): KAB
K 121150
Device Name: Pixel RF Tips
Indications for Use:
### Intended Use
The Alma Lasers Family of Accent RF Systems [Accent XL, Accent Elite] is intended for use in dermatologic and general surgical procedures.
Indications for Use
The Unipolar and Bipolar handpieces, when used as a combined treatment, are indicated for the non-invasive treatment of wrinkles and rhytids.
The Pixel RF Tips (stationary and rolling), when used with the unipolar handpiece, are indicated for dermatological procedures requiring ablation and resurfacing of the skin.
Nilke. Sgle. for nxm
(Division Sign-Off) Division of Surgical, Orthopedic, and Restorative Devices
510(k) Number
Prescription Use . V
AND/OR
Over-The-Counter Use
(Part 21 CFR 801 Subpart D)
(21 CFR 801 Subpart C)
# (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Premarket Notification, Special 510(k) Submission for: Alma Lasers Accent Pixel® Tips
{11}------------------------------------------------
# K121150
.
.
:
:
.
. ' .
・
+ -:
:
· .
.
"
Concurrence of CDRH, Office of Device Evaluation (ODE)
・
.
.
Page . . :
. " .
.
Premarket Notification, Special 510(k) Submission for:
Alma Lasers Accent Pixel® Tips
l in of th י
್ನಿ
e
·
('ম
---
i
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.